Description Design And Construction Designed per Hei twelfth edition Constructed and stamped per Asme sect. Viii, div.1 Exterior carbon steel grit blasted per Sspc-sp-1063t Horizontal steam inlet to accept axial turbine exhaust Steam inlet impingement protection included Operating Parameters Absolute pressure at steam inlet: Hga, 21.79 Steam condenser: lb per hour 22856 Circulating water fresh water: gpm: 2171 Water specific gravity, specific heat btu: lb f1,1 Water inlet and outlet: ℉ 87 to 107 Water pressure loss: ft h20, psi 7.85,3.4 Tube velocity: ft per second 10.01 Heat rejected: btu per hour 21713200 Overall service heat transfer rate: btu per ft2 per hour f 633.83 Log mean temperature difference: ^f 98.94 Percent clean: 85 Surface And Tube Specifications Surface area total of effective ft2 352.25, 346.23 Number of water passes: 1 Number of tubes: 184 Outside diameter: (in) bwg 0.75 to 22 aw Total tube length: ft 9.75 Hotwell Cylindrical supply min 1