Search results for: 'Dryin'
- Related search terms
- Drying ca
- Drying cans
- drying
-
L-5934 MONFORTS 6-F TWIN AIR STENTER YEAR 2003 – WORKING WIDTH 2400mmREFERENCE NUMBER: L-5934
MONFORTS 6-F TWIN AIR STENTER YEAR 2003 – WORKING WIDTH 2400mm
STENTER
RAMA MONFORTS
MAKE: MONFORTS
MODEL: 6-F TWIN
YEAR: 2003
440 VAC 60HZ
NATURAL GAS
AIR COMPRESSOR 7 BAR
QUANTITY: 1
Learn More -
L-5047 STALAM RADIO FREQUENCY DRYER, 130 KW, WATER COOLED, YEAR 1994REFERENCE NUMBER: L-5047
Learn More
BRAND: STALAM
TUNNEL HEIGHT: 400mm
YEAR: 1994
QUANTITY: 1 -
P-4996 GOLLER SOAPER MACHINE SIZE 72 INCHESP-4996 GOLLER SOAPER MACHINE SIZE 72 INCHES
GOLLER
SOAPER MACHINE
SIZE: 72 INCHES
HAVING 2 S.S COMPARTMENT
COMPLETE WITH 16 CYLINDER VERTICAL S.S DRYING RANGE
COMPLETE IN ALL RESPECT WITH ELECTRICAL
IN GOOD RUNNING CONDITIONQUANTITY: 1
Learn More -
J-0103 MONFORTS SANFORIZER YEAR 1996J-0103 MONFORTS SANFORIZER YEAR 1996
YEAR 1996
74” FABRIC
77” RUBBER BELT
80” WIDE MAIN DRYING CYLINDERQUANTITY: 1
Learn More -
R-1429 MONFORTS SANFORISER, WIDTH 2400mmR-1429 MONFORTS SANFORISER, WIDTH 2400mm
MONFORTS SANFORISER
MAX FABRIC WIDTH: 2400mm
THIS SANFORISER IS EXCEPTIONALLY WELL EQUIPPED
WITH A MAHLO WEFT STRAIGHTENER
AND A 10MT LONG CLIP TENTER
THE RUBBER BELT
WHICH IS IN ALMOST AS NEW CONDITION IS 2460mm WIDE
AND THE PALMER CYLINDER IS 2400mm DIAM.
MAKING IT SUITABLE FOR PROCESSING A WIDE RANGE OF FABRICS FROM LIGHTER WEIGHT APPAREL FABRICS TO DENIM
TWILLS AND BED SHEETINGS
HIGH ENTRANCE FRAME WITH ONE PAIR KF10 GUIDERS ON A SCREWED WIDTH ADJUSTMENT SHAFT
COMPENSATOR AND TENSION CONTROL RAILS
DRIVEN DRAW ROLLER
COMPENSATOR
MAHLO BOW AND SKEW WEFT STRAIGHTENER, 4 HEADS
CLIP TENTER, 10M WITH STEAMING FIELD
RUBBER BELT SHRINKING MACHINE
RUBBER BELT WIDTH 2460mm
PALMER CALENDER WITH 240CM DIAMETER CYLINDER
ENDLESS FELT BLANKET 2470mm WIDE
BLANKET DRYING CYLINDER
COOLING CYLINDER, WATER COOLED
DRAW ROLLERS
SCRAY FOR NON-STOP BATCHING
EXIT FRAME WITH DRAW ROLLER
SURFACE DRIVEN A-FRAME BATCHER AND PLAITERQUANTITY: 1
Learn More -
P-4891 MONFORTS SANFORIZER YEAR 1990 to 1991 WIDTH 1800mmP-4891 MONFORTS SANFORIZER YEAR 1990 to 1991 WIDTH 1800mm
MONFORTS
SANFORIZER
YEAR: 1990 to 1991
WORKING WIDTH: 1800mm
ROLLER WIDTH: 2000mm
HIGH ENTRY FEEDING UNIT TYPE E+A COMBI
E/L SELVEDGE UNCURLERS KF2020
GUIDE ROLLER STAINLESS STEEL
WEKO HUMIDIFICATION DEVICE BY ROTATING SPRAY DISC
STEAMING CYLINDER, DIAMETER 800mm
TENTER
LENGTH 1500mm
CLIP CHAIN
WIDTH CONTROL
SEMIAUTOMATIC CALANDER ROLLER
RUBBER
ROLLER WIDTH 1650mm
INCLUDING NEW RUBBER BLANKET
1780mm WIDTH
FELT CALANDER WITH DRYING CYLINDER 1500/800mm
ROLLER WIDTH 1900mm (FELT BLANKET 1740mm)
COOLING CYLINDER
DELIVERY TO BIG BATCHER OR PLAITER
SHRINKAGE CONTROLQUANTITY: 1
Learn More -
M-6262 RF SYSTEMS TD-85 RADIO FREQUENCY DRYER FOR CONES YEAR 2002M-6262 RF SYSTEMS TD-85 RADIO FREQUENCY DRYER FOR CONES YEAR 2002
RADIO FREQUENCY DRYER FOR CONES
MAKE: RF SYSTEMS
MODEL: TD-85 (K85)
YEAR: 2002
THREE PHASES 380 – 50 HZ
FOR DIFFERENT VOLTAGE THE MACHINE IS EQUIPPED WITH AUTO TRANSFORMER
THE NOMINAL VOLTAGE SHOULD BE WITHIN 5% (TEMPORARY EXCURSIONS OF +5% AND -5% ARE PERMITTED) OTHERWISE CUSTOMER MUST INSTALL A SUITABLE STABILIZER
MAXIMUM POWER ABSORBED FROM THE MAINS: 130 KVA
MAXIMUM CURRENT ABSORBED: 210 A
GAUGE WIRE: 3x75mm2 + GROUND 50mm2 MINIMUMGENERATOR
MAXIMUM POWER RADIO FREQUENCY GENERATOR: 85 KW (1 x 85KW)
WORK FREQUENCY: 27 MHZ
COOLING SYSTEM: FORCED AIR
MAXIMUM ROOM TEMPERATURE: TA = 35°C IF HIGHER POWER MUST BE REDUCED
MAXIMUM EXHAUST AIR TEMPERATURE: TU = 85°C
OSCILLATOR: CAVITY TYPE WITH HIGH OVERALL EFFICIENCY
FREQUENCY STABILITY: WITHIN LIMITS
RADIATED FIELD: WITHIN LIMITS
GRID CURRENT WITH NO LOAD: 2.3 A TO 2.5 A
GRID CURRENT MINIMUM WITH FULL LOAD: 1.4 A
TRIODE TYPE: RS 3060 CL
FILAMENT TRIODE VOLTAGE: 10 V + 1% - 3%BELT – CONVEYOR
MATERIAL: POLYESTER FABRIC
TRACKING: AUTOMATIC
LENGTH: 21600mm
WIDTH: 1750mm
RANGE OF CONVEYOR SPEED: 0 TO 50 M/ORA
ELECTRODE: STANDARD TYPEPRODUCTIVITY
MAXIMUM EVAPORATING CAPACITY: 90 KG WATER PER HOURDIMENSIONS
LENGTH: 9600mm
WIDTH: 2124mm
MAXIMUM HEIGHT: 3400mm
GALLERY LENGTH: 4000mm
INLET LENGTH: 2800mm
OUTLET LENGTH: 2800mm
BELT WIDTH: 1750mm
LOAD HEIGHT: 900mm
MAXIMUM HEIGHT OF INLET TRAP: 300mmTHE DRYER TD85 IS COMPOSED OF ONE UNITY OF 85 KW
SPECIAL REQUIREMENTS ON USING RADIO FREQUENCY DRYER
THE DRYER CAN ACCEPT ONLY HYDROEXTRACT GOODS WITH EVEN MOISTURE CONTENT
POSSIBLE FIRE HAZARD WHEN DEALING WITH UNEXTRACTED PACKAGES
PROPEN HYDROEXTRACTION IS IMPORTANT PRIOR TO RF DRYER
LOAD PRODUCT WITH SAME DIMENSIONS AND SIMILAR MOISTURE CONTENTS
PACKAGE PLACEMENT ON THE BELT. ANY TYPE OF TUBE MAY BE USED IN A CONTINUED RF DRYER
METAL TUBES REQUIRE MOVE CARE IN PLACEMENT ON THE BELT THEN PLASTIC TUBE
METAL TUBES CAN CAUSE SHORT CIRCUITY, OR ARCING, FROM ONE ELECTRODE TO GROUND, WHICH CAN DAMAGE THE BELT OR CAUSE FIRE
PACKAGE WITH METAL TUBES MUST BE PLACED ON THE BELT SO THE METAL IS PARALLEL TO THE ELECTRODES AS SHONS IS TY
THE CONVEYOR SHOULD ALWAYS BE LOADED EVENLY, WITH NO BIG EMPTY GAPS
LOAD AS MUCH AS YOU CAN
GOOD WITH DIFFERENTS SIZE ARE NOT ALLOWED THEY CAN GET BURNS
LOAD A QUANTITY OF GOODS WITH A QUANTITY OF WATER TO REMOVE PER LINEAR METER OF BELT AROUND 5 TO 15 KG PER LINEAR METER OF BELT
THE MACHINE CANNOT ACCEPT METALLIC DYSTUFF (EX.CHROME)
DO NOT ENTER METALLIC PARTS
METALLIC IN THE GALLERY CAUSES ELECTRICAL DISCHARGES WHICH MAY THOROUGHLY RUIN BELT AND SET THE DRYING MATERIAL ON FIREQUANTITY: 1
Learn More -
M-6248 SANTEX DRYER YEAR 1997 WIDTH 2400mmM-6248 SANTEX DRYER YEAR 1997 WIDTH 2400mm
DRYING MACHINE
MAKE: SANTEX
WORKING WIDTH: 2400mm
YEAR: 1997
DOUBLE FOULARD
GAS-HEATED
NUMBER OF ROOMS: 5MACHINE IS IN VERY GOOD CONDITION
QUANTITY: 1
Learn More

