L-5934 MONFORTS 6-F TWIN AIR STENTER YEAR 2003 – WORKING WIDTH 2400mmREFERENCE NUMBER: L-5934
MONFORTS 6-F TWIN AIR STENTER YEAR 2003 – WORKING WIDTH 2400mm
STENTER
RAMA MONFORTS
MAKE: MONFORTS
MODEL: 6-F TWIN
YEAR: 2003
440 VAC 60HZ
NATURAL GAS
AIR COMPRESSOR 7 BAR
QUANTITY: 1
Learn More -
R-1391 OSTHOFF SINGEING RANGE, WORKING WIDTH 1800mm, YEAR 1983 TO 1993R-1391 OSTHOFF SINGEING , WORKING WIDTH 1800mm, YEAR 1983 TO 1993
OSTHOFF SINGEING RANGE
WORKING WIDTH: 1800mm
YEAR: 1983 TO 1993
PRE TENSION DRIVEN ENTRY WITH J BOX SCRAY
WITH DOUBLE BRUSHING UNIT
E+L KF20 WITH CENTRALISING GUIDERS
OSTHOFF SINGE TYPE U80 WITH 2 GAS BURNERS
E+L DOGAL GUIDER COMPLETE
WITH CONOSCREEN ROTORY MICROFILTERING
YEAR: 2005
NUOVA - RUDECO EXTRACTION DUST SYSTEM
YEAR: 2000
SIEMENS PLC CONTORLES FITTED IN YEAR: 2000
OXIDIZATION SECTION 10 METER CLOTH CONTENT
KUSTER DESIZING WITH 2 DESIZE TANKS AND 2 PADDERS
2 CHEMICAL MIXING TANKS
TAKE OFF BY CONTACT BATCHERQUANTITY: 1
Learn More -
M-6262 RF SYSTEMS TD-85 RADIO FREQUENCY DRYER FOR CONES YEAR 2002M-6262 RF SYSTEMS TD-85 RADIO FREQUENCY DRYER FOR CONES YEAR 2002
RADIO FREQUENCY DRYER FOR CONES
MAKE: RF SYSTEMS
MODEL: TD-85 (K85)
YEAR: 2002
THREE PHASES 380 – 50 HZ
FOR DIFFERENT VOLTAGE THE MACHINE IS EQUIPPED WITH AUTO TRANSFORMER
THE NOMINAL VOLTAGE SHOULD BE WITHIN 5% (TEMPORARY EXCURSIONS OF +5% AND -5% ARE PERMITTED) OTHERWISE CUSTOMER MUST INSTALL A SUITABLE STABILIZER
MAXIMUM POWER ABSORBED FROM THE MAINS: 130 KVA
MAXIMUM CURRENT ABSORBED: 210 A
GAUGE WIRE: 3x75mm2 + GROUND 50mm2 MINIMUMGENERATOR
MAXIMUM POWER RADIO FREQUENCY GENERATOR: 85 KW (1 x 85KW)
WORK FREQUENCY: 27 MHZ
COOLING SYSTEM: FORCED AIR
MAXIMUM ROOM TEMPERATURE: TA = 35°C IF HIGHER POWER MUST BE REDUCED
MAXIMUM EXHAUST AIR TEMPERATURE: TU = 85°C
OSCILLATOR: CAVITY TYPE WITH HIGH OVERALL EFFICIENCY
FREQUENCY STABILITY: WITHIN LIMITS
RADIATED FIELD: WITHIN LIMITS
GRID CURRENT WITH NO LOAD: 2.3 A TO 2.5 A
GRID CURRENT MINIMUM WITH FULL LOAD: 1.4 A
TRIODE TYPE: RS 3060 CL
FILAMENT TRIODE VOLTAGE: 10 V + 1% - 3%BELT – CONVEYOR
MATERIAL: POLYESTER FABRIC
TRACKING: AUTOMATIC
LENGTH: 21600mm
WIDTH: 1750mm
RANGE OF CONVEYOR SPEED: 0 TO 50 M/ORA
ELECTRODE: STANDARD TYPEPRODUCTIVITY
MAXIMUM EVAPORATING CAPACITY: 90 KG WATER PER HOURDIMENSIONS
LENGTH: 9600mm
WIDTH: 2124mm
MAXIMUM HEIGHT: 3400mm
GALLERY LENGTH: 4000mm
INLET LENGTH: 2800mm
OUTLET LENGTH: 2800mm
BELT WIDTH: 1750mm
LOAD HEIGHT: 900mm
MAXIMUM HEIGHT OF INLET TRAP: 300mmTHE DRYER TD85 IS COMPOSED OF ONE UNITY OF 85 KW
SPECIAL REQUIREMENTS ON USING RADIO FREQUENCY DRYER
THE DRYER CAN ACCEPT ONLY HYDROEXTRACT GOODS WITH EVEN MOISTURE CONTENT
POSSIBLE FIRE HAZARD WHEN DEALING WITH UNEXTRACTED PACKAGES
PROPEN HYDROEXTRACTION IS IMPORTANT PRIOR TO RF DRYER
LOAD PRODUCT WITH SAME DIMENSIONS AND SIMILAR MOISTURE CONTENTS
PACKAGE PLACEMENT ON THE BELT. ANY TYPE OF TUBE MAY BE USED IN A CONTINUED RF DRYER
METAL TUBES REQUIRE MOVE CARE IN PLACEMENT ON THE BELT THEN PLASTIC TUBE
METAL TUBES CAN CAUSE SHORT CIRCUITY, OR ARCING, FROM ONE ELECTRODE TO GROUND, WHICH CAN DAMAGE THE BELT OR CAUSE FIRE
PACKAGE WITH METAL TUBES MUST BE PLACED ON THE BELT SO THE METAL IS PARALLEL TO THE ELECTRODES AS SHONS IS TY
THE CONVEYOR SHOULD ALWAYS BE LOADED EVENLY, WITH NO BIG EMPTY GAPS
LOAD AS MUCH AS YOU CAN
GOOD WITH DIFFERENTS SIZE ARE NOT ALLOWED THEY CAN GET BURNS
LOAD A QUANTITY OF GOODS WITH A QUANTITY OF WATER TO REMOVE PER LINEAR METER OF BELT AROUND 5 TO 15 KG PER LINEAR METER OF BELT
THE MACHINE CANNOT ACCEPT METALLIC DYSTUFF (EX.CHROME)
DO NOT ENTER METALLIC PARTS
METALLIC IN THE GALLERY CAUSES ELECTRICAL DISCHARGES WHICH MAY THOROUGHLY RUIN BELT AND SET THE DRYING MATERIAL ON FIREQUANTITY: 1
Learn More -
P-4818 STORK ROTARY PRINTING YEAR 1989 WIDTH 1800mm 14 COLORS 3 CHAMBERSP-4818 STORK ROTARY PRINTING YEAR 1989 WIDTH 1800mm 14 COLORS 3 CHAMBERS
STORK
TYPE: RD IV-16/14
ROTARY PRINTING
YEAR: 1989
WORKING WIDTH: 1800mmQUANTITY: 1
Learn More -
P-2524 BRUCKNER STENTER YEAR 2000 WIDTH 3600mm 8 CHAMBERS AS HEATEDREFERENCE NUMBER: P-2524 BRUCKNER STENTER YEAR 2000 WIDTH 3600mm 8 CHAMBERS AS HEATED BRUCKNER STENTER YEAR: 2000 WIDTH: 3600mm COMPOSED OF: BIANCO ENTRY YEAR: 2000 MODEL: LINEA ENTRATA RAM FOULARD 2 ROLLERS WITH PNEUMATIC PRESSURE VDTEX WEFT STRAIGHTNER WITH 8 HEADS 6 METERS ENTRY HORIZONTAL PIN CHAIN 8 CHAMBERS GAS HEATED WITH BRUCKNER ECLIPSE BURNERS EXIT BY BIANCO YEAR: 2000 MODEL: LINEA USCTICA RAM QUANTITY AVAILABLE: 1 Learn More -
A-1275 BABCOCK ARTOS STENTER FRAME FOR KNITTED FABRICSREFERENCE NUMBER: A-1275 (010123JGHB12RC) A BABCOCK ARTOS STENTER FRAME FOR KNITTED FABRICS YEAR: 2003 TYPE: ECON-AIR ROLLER WIDTH: 2600MM FABRIC WIDTH: 2400MM 6 CHAMBERS QUANTITY AVAILABLE: 1 Learn More -
MARSHALL AND WILLIAMS TENTER, KUSTER PAD, MAHLO WEFT STRAIGHTENER -100" (2286mm)(1) MARSHALL AND WILLIAMS TENTER FRAME-100” FABRIC-4 ZONES-CLIP (1) KUSTER PAD (1) MAHLO WEFT STRAIGHTENER (1) SALVAGE EDGE TRIMMER MACHINE (HOME MADE-NO BRAND) (1) A-FRAME WINDER Learn More