- K-9326 BABCOCK WIDE TENTER FRAME 144" (3657mm)REFERENCE NUMBER: K-9326 BABCOCK WIDE TENTER FRAME 144" (3657mm) QUANTITY AVAILABLE: 1 Learn More
- G-8230 HIGH-TEMPERATURE AND HIGH-PRESSURE YARN DYEING MACHINE 40KG
REFERENCE NUMBER: G-8230
HIGH-TEMPERETURE AND HIGH-PRESSURE YARN DYEING MACHINE 40KG
DESIGNED FOR DYEING, BOILING OFF, BLEACHING, AND WATER WASHING, ETC. SUITABLE FOR HANK YARN, BOBBIN OR RAW STOCK FIBER
MACHINE TYPE: VERTICAL CYLINDER
VAT DIAMETER: Ф600mm
CONE QUANTITY: 7 X 7 = 49 CONES
WORKING TEMPERATURE: 130C
MAX WORKING PRESSURE: 0.4MPA
BOTH RATIO: 1:7 TO 9
WITH COMPUTERIZED CONTROL SYSTEM
HEAT EXCHANGING: COIL TYPE HEAT EXCHANGER, WHICH CAN BE USED FOR EITHER HEATING OR COOLING.
HEAT EXCHANGING SPEED: WHEN THE HEATED STEAM PRESSURE IS 0.4MPA, 40MINUTES WILL BE REQUIRED FOR THE LIQUID INSIDE THE DYEING BARREL RAISING FROM 20OC TO 130OC. WHEN THE COOLING WATER PRESSURE IS 0. 3MPA AND THE WATER TEMPERATURE IS 20 OC, 40 MINUTES WILL BE REQUIRED FOR THE LIQUID INSIDE THE DYEING BECK TO LOWER FROM 130OC TO 80OC.
RECYCLING OF DYEING LIQUID: THE POSITIVE AND NEGATIVE RECYCLING OF DYEING LIQUID WILL BE ADJUSTED BY THE CYLINDER THROUGH THE SWITCHING DEVICE INSIDE THE CENTRIFUGAL PUMP.
SEALING OF BOILER: RUBBER ADHESIVE
THE WORKING PRESSURE INSIDE THE TANK WILL MAKE THE RUBBER SEAL CLOSELY TO ATTACH THE FLANGE. THE CONICAL SURFACE OF THE TANK MOUTH IS TO ENHANCE THE SEALING.
OPENING OF TANK COVER: FIRST OPEN THE AIR VALVE TO RELEASE THE PRESSURE INSIDE THE BOILER. WAIT UNTIL NO EXHAUSTED AIR GOING THRU THE EXHAUST VALVE AND THE READING OF PRESSURE GAUGE IS ZERO, WITHDRAW THE WRENCH HANDLE, OPEN THE CLAMPING HOOP TO REMOVE THE FLANGE; AND THEN OPEN THE COVER WITH DRAG WEIGHT. THE COVER WILL BE CLOSED.
CONFIGURATION:
1. ELECTRICAL CABINET: STAINLESS STEEL CABINET, PLASTIC COATING
2. ELECTRICAL COMPONENTS: SIEMENS, OMRON
3. COMPUTER: HG COMPUTER (MADE IN CHINA)
4. ELECTROMAGNETIC VALVE: TAIWAN YADEKE
5. PUMP: CENTRIFUGAL PUMP
6. MOTOR: WANNAN MOTOR
7. TEMPERATURE CONTROL: COMPUTER CONTROL, WITH HEATING, COOLING, KEEPING WARM, ETC. FUNCTION.
8. HEAT EXCHANGER: INTERNAL COIL HEATING
9. VALVE: STAINLESS ANGLE VALVES, PNEUMATIC BUTTERFLY VALVES
10. ONE CARRIER BASKET
11. MACHINE BODY MATERIAL: STAINLESS STEEL, 316 LITERS
12. ACCESSORIES: SEAL RING FOR DYE VAT, SEAL FOR MAIN PUMP, SEAL FOR REVERSING SHAFT
QUANTITY: 1
Learn More - TT-2812 MATHERM CERATHERM SP INFRA-RED DRYING UNIT, WORKING WIDTH 2400mm, YEAR 2010TT-2812 MATHERM CERATHERM SP INFRA-RED DRYING UNIT, WORKING WIDTH 2400mm, YEAR 2010 QUANTITY: 1 Learn More
- TT-6339 COMPLETE PLANT FOR MODERN DENIM DYEING & FINISHING, YEAR 2004TT-6339 COMPLETE PLANT FOR MODERN DENIM DYEING & FINISHING, YEAR 2004 Learn More
- P-2067 SCLAVOS HT DYE MACHINE YEAR 1994 3 PORTSREFERENCE NUMBER: P-2067 SCLAVOS HT DYE MACHINE YEAR 1994 3 PORTS SCLAVOS HT DYE MACHINE YEAR: 1994 3 PORTS 140 DEGREE C CAPACITY: 500 KILOGRAMS EQUIPPED WITH: HEAT EXCHANGER ADD TANKS DOSING PUMPS OPERATOR PLAT FORM & COMPLETE WITH ELECTRICAL PANEL MACHINE IS STILL IN PRODUCTION 15 HP MAIN PUMP 50HZ 1HP 3HP LOWER N UNLOADING QUANTITY AVAILABLE: 1 Learn More
- P-1813 BRAZZOLI H.T. SATURNO LUFT HTF DYEING MACHINE YEAR 2002 400KGREFERENCE NUMBER: P-1813 BRAZZOLI H.T. SATURNO LUFT HTF DYEING MACHINE YEAR 2002 400KG BRAZZOLI MODEL: H.T. DYEING MACHINE TYPE: SATURNO LUFT HTF FOR TERRY TOWEL FABRICS YEAR: 2002 CAPACITY: 400 KILOGRAMS EACH MACHINE TEHSE MACHINES CAN ALSO BE OPERATED COUPLED TO DYE ONE LOT OF 800 KILOGRAMS SUPPLIED WITH MAIN MOTOR AND PUMP AUTOMATIC VALVES FOR STEAM AND WATER FUNCTIONS ADD TANK + DOSING PUMP ELECTRICAL PANEL WITH MICROPROCESSOR CONTROLS TEST RUN POSSIBLE, SINCE THE UNITS ARE STILL FULLY CONNECTED TO THE ELECTRICITY, STEAM, WATER, ETC QUANTITY AVAILABLE: 2 Learn More
- J-0031 BRUCKNER DOUBLE LAYER STENTER YEAR 1998 WIDTH 2200mm – 8 CHAMBERSREFERENCE NUMBER: J-0031 (131314MJKL12R) BRUCKNER DOUBLE LAYER STENTER YEAR 1998 WIDTH 2200mm – 8 CHAMBERS QUANTITY AVAILABLE: 1 Learn More
- R-7198 SALVADE RELAX DRYER MACHINE, WORKING WIDTH 2400mm, YEAR 1995 – FOR KNITS
R-7198 SALVADE RELAX DRYER MACHINE, WORKING WIDTH 2400mm, YEAR 1995 – FOR KNITS
BRAND: SALVADE S.P.A. ITALY
MODEL: AVA
YEAR: 1995
WORKING WIDTH: 2400mm
TYPE: TWO PASSAGES OF KNITS, KNITS INPUT AND OUTPUT ON ONE SIDE (OPEN DRYER MACHINE)
GAS HEATING, TWO GAS BURNERS ITAS, MODEL: 84 A TBH
GAS BURNERS CAPACITY MAX.: 522 KW, 440,000 KCAL/H
SWITCHBOARD AND ELECTRICAL MOTORS: 380V, 50 HZQUANTITY: 1
Learn More - M-6262 RF SYSTEMS TD-85 RADIO FREQUENCY DRYER FOR CONES YEAR 2002
M-6262 RF SYSTEMS TD-85 RADIO FREQUENCY DRYER FOR CONES YEAR 2002
RADIO FREQUENCY DRYER FOR CONES
MAKE: RF SYSTEMS
MODEL: TD-85 (K85)
YEAR: 2002
THREE PHASES 380 – 50 HZ
FOR DIFFERENT VOLTAGE THE MACHINE IS EQUIPPED WITH AUTO TRANSFORMER
THE NOMINAL VOLTAGE SHOULD BE WITHIN 5% (TEMPORARY EXCURSIONS OF +5% AND -5% ARE PERMITTED) OTHERWISE CUSTOMER MUST INSTALL A SUITABLE STABILIZER
MAXIMUM POWER ABSORBED FROM THE MAINS: 130 KVA
MAXIMUM CURRENT ABSORBED: 210 A
GAUGE WIRE: 3x75mm2 + GROUND 50mm2 MINIMUMGENERATOR
MAXIMUM POWER RADIO FREQUENCY GENERATOR: 85 KW (1 x 85KW)
WORK FREQUENCY: 27 MHZ
COOLING SYSTEM: FORCED AIR
MAXIMUM ROOM TEMPERATURE: TA = 35°C IF HIGHER POWER MUST BE REDUCED
MAXIMUM EXHAUST AIR TEMPERATURE: TU = 85°C
OSCILLATOR: CAVITY TYPE WITH HIGH OVERALL EFFICIENCY
FREQUENCY STABILITY: WITHIN LIMITS
RADIATED FIELD: WITHIN LIMITS
GRID CURRENT WITH NO LOAD: 2.3 A TO 2.5 A
GRID CURRENT MINIMUM WITH FULL LOAD: 1.4 A
TRIODE TYPE: RS 3060 CL
FILAMENT TRIODE VOLTAGE: 10 V + 1% - 3%BELT – CONVEYOR
MATERIAL: POLYESTER FABRIC
TRACKING: AUTOMATIC
LENGTH: 21600mm
WIDTH: 1750mm
RANGE OF CONVEYOR SPEED: 0 TO 50 M/ORA
ELECTRODE: STANDARD TYPEPRODUCTIVITY
MAXIMUM EVAPORATING CAPACITY: 90 KG WATER PER HOURDIMENSIONS
LENGTH: 9600mm
WIDTH: 2124mm
MAXIMUM HEIGHT: 3400mm
GALLERY LENGTH: 4000mm
INLET LENGTH: 2800mm
OUTLET LENGTH: 2800mm
BELT WIDTH: 1750mm
LOAD HEIGHT: 900mm
MAXIMUM HEIGHT OF INLET TRAP: 300mmTHE DRYER TD85 IS COMPOSED OF ONE UNITY OF 85 KW
SPECIAL REQUIREMENTS ON USING RADIO FREQUENCY DRYER
THE DRYER CAN ACCEPT ONLY HYDROEXTRACT GOODS WITH EVEN MOISTURE CONTENT
POSSIBLE FIRE HAZARD WHEN DEALING WITH UNEXTRACTED PACKAGES
PROPEN HYDROEXTRACTION IS IMPORTANT PRIOR TO RF DRYER
LOAD PRODUCT WITH SAME DIMENSIONS AND SIMILAR MOISTURE CONTENTS
PACKAGE PLACEMENT ON THE BELT. ANY TYPE OF TUBE MAY BE USED IN A CONTINUED RF DRYER
METAL TUBES REQUIRE MOVE CARE IN PLACEMENT ON THE BELT THEN PLASTIC TUBE
METAL TUBES CAN CAUSE SHORT CIRCUITY, OR ARCING, FROM ONE ELECTRODE TO GROUND, WHICH CAN DAMAGE THE BELT OR CAUSE FIRE
PACKAGE WITH METAL TUBES MUST BE PLACED ON THE BELT SO THE METAL IS PARALLEL TO THE ELECTRODES AS SHONS IS TY
THE CONVEYOR SHOULD ALWAYS BE LOADED EVENLY, WITH NO BIG EMPTY GAPS
LOAD AS MUCH AS YOU CAN
GOOD WITH DIFFERENTS SIZE ARE NOT ALLOWED THEY CAN GET BURNS
LOAD A QUANTITY OF GOODS WITH A QUANTITY OF WATER TO REMOVE PER LINEAR METER OF BELT AROUND 5 TO 15 KG PER LINEAR METER OF BELT
THE MACHINE CANNOT ACCEPT METALLIC DYSTUFF (EX.CHROME)
DO NOT ENTER METALLIC PARTS
METALLIC IN THE GALLERY CAUSES ELECTRICAL DISCHARGES WHICH MAY THOROUGHLY RUIN BELT AND SET THE DRYING MATERIAL ON FIREQUANTITY: 1