Search results for: 'SIEMENS'
- Related search terms
- Siemens ge
- Siemens gen
- siemens gas turbine
- SIEMENS GAS TURBINE
- SIEMENS T
- G-4425 CHICKEN SLAUGHTER LINE 1500 PER HOURREFERENCE NUMBER: G-4425 CHICKEN SLAUGHTER LINE 1500 PER HOUR QUANTITY AVAILABLE: 1 Learn More
- R-9600 PROBAT GG120 BATCH ROASTER
REFERENCE NUMBER: R-9600
PROBAT GG120 BATCH ROASTER
BATCH ROASTER
MAKE: PROBAT
MODEL: GG120
OUTPUT CAPACITY: 500 KG PER HOUR
MACHINE IN FULLY REBUILT CONDITION, WARRANTY 6 MONTHS
QUANTITY: 1
Learn More - L-4532 DATGEN ROASTERS
L-4532 DATGEN ROASTERS
MODELS AVAILABLE: DR 1, 3, 5, 12, 25, & 35
MODEL DR-1
CAPACITY: 0.5 TO 1.25 KGSMODEL DR-3
CAPACITY: 0.1 KGS TO 2.5 KGS
HOURLY ROAST OUTPUT: 10 KGS
VOLTAGE: 230 VOLTS @ 60 Hz OR 400 VOLTS @ 50 Hz
40,000 BTU, 26.2 KW
FUEL: PROPANE OR NATURAL GAS
ROASTER WEIGHT: 100 KGS
ROASTER DIMENSIONS: 1400mm TALL X 1200mm LONG X 1100mm WIDE
EXHAUST PIPE DIAMETER: 130mm
COMPUTER CONNECTION: RS 485
DRIVE: 4 MOTORS
MOTOR POWER: 1 KW PER HOURMODEL DR-5
CAPACITY: 0.5 KGS TO 5 KGS
HOURLY ROAST OUTPUT: 15 KGS
VOLTAGE: 230 VOLTS @ 60 Hz OR 400 VOLTS @ 50 Hz
90,000 BTU, 26.2 KW
FUEL: PROPANE OR NATURAL GAS
ROASTER WEIGHT: 300 KGS
DIMENSIONS: 1470mm TALL x 1750mm LONG X 1140mm WIDE
EXHAUST PIPE DIAMETER: 150mm
DRIVE: 4 MOTORS
MOTOR POWER: 2 KW PER HOURMODEL: DR-12
CAPACITY: 0.5 TO 12 KGS PER BATCH (MAX 15 KGS OF GREEN BEANS)
OPERATING TIME: 5 TO 18 MINUTES PER BATCH, DEPENDING ON ROASTING PROFILES
ROASTER DIMENSIONS: 1160mm WIDE X 1430mm LONG X 1800mm TALL
WEIGHT: 410 KGS
POWER: 230 VOLTS @ 60 Hz OR 400 VOLTS @ 50 Hz
FUEL: PROPANE OR NATURAL GAS
GAS PRESSURE: NATURAL GAS ABOVE 2 KPA / PROPANE ABOVE 2.9 KPA
90,000 BTU PER HOUR
EXHAUST PIPE DIAMETER: 150mm
ROAST AIR SCFM/SCMH: 380 SCFM / 650 SCMHMODEL: DR-30
CAPACITY: 2.5 TO 37.5 KGSMODEL: DR-60
CAPACITY: 2.5 TO 75 KGS - L-4513 DATGEN COFFEE ROASTERS, 25KGS TO 60 KGS
L-4513 DATGEN COFFEE ROASTERS, 25KGS TO 60 KGS
MODELS AVAILABLE: 25 KGS, 35 KGS, AND 60 KGS
Learn More
WITH DRUM SPEED CONTROL
COOLING FAN SPEED CONTROL
FLAME INTENSITY CONTROL
ALL ARTISAN SOFTWARE READY
WITH 2 YEAR WARRANTY AND TECH SUPPORT
RUN WITH DUNGS COMBUSTION SYSTEM AND SIEMENS MOTORS
CAN ALSO HAVE AUTO FILLING/UNLOADING - R-3250 GIESEN COFFEE ROASTER AND SELKIRK OXIDIZER - 15 KILOS
R-3250 GIESEN COFFEE ROASTER AND SELKIRK OXIDIZER - 15 KILOS
AN EXCEPTIONAL OPPORTUNITY FOR READY TO BE DELIVERED/INSTALLED EQUIPMENT CREATED BY A CHANGED BUSINESS MODEL.
GIESEN W15A
DOUBLE EXHAUST/ROAST PROFILE SYSTEM
NATURAL GAS
240V/60 HZ
COLOR: RED
AVAILABLE WITH SELKIRK TO-2CS321 THERMAL OXIDIZER (USED)GIESEN BROCHURE
SPECIFICATIONS:
GIESEN W15A
CAPACITY: 500 GRAM - 15 KG GREEN BEANS / PER BATCH / M. 60 KG/H
DRIVES: DIRECT FREQUENCY DRIVE MOTOR. ADJUSTABLE DRUM SPEED CONTROL AND ADJUSTABLE ROAST FAN SPEED CONTROL.
ROAST DRUM: DIGITAL PRESSION CONTROL. CAST IRON DRUM WITH HIGH PERFORMANCE BEARINGS.
HEATING SYSTEM: GAS BURNER BY PROPANE GAS (LPG, BOTTLE GAS) OR CITY GAS.
VOLTAGE: 1 PHASE 230V / 50-60 HZ
PAINTING: FREE CHOICE AND CUSTOMIZED / RAL CODES
ROAST ROOF: FREE CHOICE AND CUSTOMIZED
DIMENSIONS: LENGTH 1900mm X WIDTH 962mm X HEIGHT 2000mm
EXHAUST PIPE: EXHAUST PIPE DIAMETER FOR ROAST AIR: ∅ 200mmTHERMAL OXIDIZER FOR GIESEN W15 ROASTER
SELKIRK SPECIALIZES IN THERMAL AFTERBURNERS FOR COFFEE ROASTING MACHINES FROM 10 TO 120 KGS PER BATCH. AFTERBURNERS ARE DESIGNED OF QUALITY MATERIALS FOR LONG SERVICE LIFE. INTEGRATED EFFICIENT GAS BURNERS WHICH REDUCE OPERATING COSTS. BURNER CONFORMS TO UL 295 STANDARD FOR COMMERCIAL/INDUSTRIAL GAS BURNERS. AFTERBURNER DESIGN PROVIDES LONG RETENTION TIMES TO ELIMINATE SMOKE AND ODORS FROM THE ROASTING PROCESS. STANDARD AFTERBURNER OPERATING TEMPERATURE IS 1250 F, BUT CAN EASILY BE ADJUSTED TO MEET LOCAL AIR QUALITY REQUIREMENTS. GAS BURNER IS COMPLETELY SELF MODULATING, AND OPERATOR CONTROLS ARE DESIGNED FOR EASE OF USE.OXIDIZER SPECIFICATIONS:
TO-2CS321 THERMAL OXIDIZER WITH THE FOLLOWING DESIGN FEATURES:
WAYNE COMBUSTION LC 1500 BURNER WITH 1.5 MILLION BTU PER HOUR MAXIMUM INPUT.
DUNGS MULTIBLOC SAFETY VALVE MBC VEF 2500.
DUNGS LOW AND HIGH GAS PRESSURE SWITCHES.
SIEMENS LME SERIES FLAME SAFETY CONTROLLER.
FLAME SENSING ROD FOR FLAME VERIFICATION.
FULLY MODULATING TO MODULATE AT PRE-SET OPERATING TEMPERATURE;
BURNER AND CONTROLS CONFORM TO UL 295 STANDARD FOR COMMERCIAL INDUSTRIAL GAS HEATING EQUIPMENT.
OPERATOR FRIENDLY CONTROL SYSTEM.
TO-2CS321 DIMENSIONS:
OUTSIDE DIAMETER: 36"
OVERALL HEIGHT FROM FLOOR: 82"
INLET DIAMETER: 6"
OUTLET DIAMETER: 10"
EXTERIOR TO BE POWDERCOATED CARBON STEEL MATTE BLACK (OPTIONAL COLORS AVAILABLE).
4" OF HIGH DENSITY CERAMIC INSULATION BETWEEN INTERIOR AND EXTERIOR SURFACES.QUANTITY: 1
Learn More - R-3249 GIESEN COFFEE ROASTER W15A SELKIRK OXIDIZER - 15 KILOS
R-3249 GIESEN COFFEE ROASTER W15A SELKIRK OXIDIZER - 15 KILOS
AN EXCEPTIONAL OPPORTUNITY FOR READY TO BE DELIVERED/INSTALLED EQUIPMENT CREATED BY A CHANGED BUSINESS MODEL.
NATURAL GAS
240V/60 HZ
BLACK/SILVERSELKIRK SPECIALIZES IN THERMAL AFTERBURNERS FOR COFFEE ROASTING MACHINES FROM 10 TO 120 KGS PER BATCH. AFTERBURNERS ARE DESIGNED OF QUALITY MATERIALS FOR LONG SERVICE LIFE. INTEGRATED EFFICIENT GAS BURNERS WHICH REDUCE OPERATING COSTS. BURNER CONFORMS TO UL 295 STANDARD FOR COMMERCIAL/INDUSTRIAL GAS BURNERS. AFTERBURNER DESIGN PROVIDES LONG RETENTION TIMES TO ELIMINATE SMOKE AND ODORS FROM THE ROASTING PROCESS. STANDARD AFTERBURNER OPERATING TEMPERATURE IS 1250 F, BUT CAN EASILY BE ADJUSTED TO MEET LOCAL AIR QUALITY REQUIREMENTS. GAS BURNER IS COMPLETELY SELF MODULATING, AND OPERATOR CONTROLS ARE DESIGNED FOR EASE OF USE.
OXIDIZER SPECIFICATIONS:
TO-2CS321 THERMAL OXIDIZER WITH THE FOLLOWING DESIGN FEATURES:
WAYNE COMBUSTION LC 1500 BURNER WITH 1.5 MILLION BTU PER HOUR MAXIMUM INPUT.
DUNGS MULTIBLOC SAFETY VALVE MBC VEF 2500.
DUNGS LOW AND HIGH GAS PRESSURE SWITCHES.
SIEMENS LME SERIES FLAME SAFETY CONTROLLER.
FLAME SENSING ROD FOR FLAME VERIFICATION.
FULLY MODULATING TO MODULATE AT PRE-SET OPERATING TEMPERATURE;
BURNER AND CONTROLS CONFORM TO UL 295 STANDARD FOR COMMERCIAL INDUSTRIAL GAS HEATING EQUIPMENT.
OPERATOR FRIENDLY CONTROL SYSTEM.
TO-2CS321 DIMENSIONS:
OUTSIDE DIAMETER: 36"
OVERALL HEIGHT FROM FLOOR: 82"
INLET DIAMETER: 6"
OUTLET DIAMETER: 10"
EXTERIOR TO BE POWDERCOATED CARBON STEEL MATTE BLACK (OPTIONAL COLORS AVAILABLE).
4" OF HIGH DENSITY CERAMIC INSULATION BETWEEN INTERIOR AND EXTERIOR SURFACES.QUANTITY: 1
Learn More - P-5093 BUHLER ROASTER 60 KILOS
P-5093 BUHLER ROASTER 60 KILOS
EVERY COFFEE MANUFACTURING APPLICATION REQUIRES INDIVIDUAL ROASTING PROCESSES FOR OPTIMIZED FLAVOR AND BEAN PROPERTIES. THIS ROASTER ADAPTS TO YOUR NEEDS AND OFFERS A MAXIMUM OF PROCESS FLEXIBILITY. IT INSPIRES YOUR PRODUCT INNOVATIONS WITH TRADITIONAL AND WITH MORE SOPHISTICATED MULTI-STEP ROASTING PROFILES. THE PROVEN DRUM ROASTING TECHNOLOGY OF THIS ROASTER ENSURES A RELIABLE, EFFICIENT AND SAFE ROASTING OPERATION.
THE OPTIMIZED DEGREE OF ROAST, THE ROASTING TIME AND THE ROASTING PROFILE MUST BE PRECISELY REPRODUCED FOR CONSISTENTLY HIGH QUALITY COFFEE PRODUCTS. THE MULTISTEP PROCESS OF THIS ROASTER ALLOWS FOR OPTIMIZED FLAVOR CREATION FOR ANY COFFEE BLEND AND VARIETIES AND ENSURES EXCELLENT CONSISTENCY. THE USER-FRIENDLY OPERATING PANEL INCLUDES A SIEMENS PLC AND A WINDOWS PANEL PC WITH 12.5 INCH TOUCH SCREEN FOR FULL PROCESS AUTOMATION AND EASY OPERATION.
FEATURES:
FULLY AUTOMATED ROASTING OPERATION
FULL RECIPE MANAGEMENT
AUTOMATED START AND STOP PROCEDURES
VARIOUS LOGIN-LEVELS FOR CUSTOMIZED ALLOCATION OF PERMISSION RIGHTS (OPERATOR, ENGINEER, ETC.)OPEN SYSTEM (NON-RECIRCULATION)
OPEN AIRFLOW SYSTEM
GAS / (DIESEL*) BURNER
DATA TRANSFER VIA ETHERNET (OPTION)
COOLING UNIT IN CONTROL CABINET (OPTION)
RECYCLE SYSTEM
RECIRCULATING AIRFLOW SYSTEM (UP TO 30% ENERGY SAVINGS COMPARED TO OPEN SYSTEMS)
GAS / (DIESEL*) BURNER
DATA TRANSFER VIA ETHERNET (OPTION)
COOLING UNIT IN CONTROL CABINET (OPTION)
HOT AIR SYSTEM: AIR RECIRCULATION OR NON-RECIRCULATING OPEN SYSTEM
HEAT GENERATION: FULLY VARIABLE LPG BURNER (WEISHAUPT) OR 2-STEP DIESEL BURNER
BATCH SIZE: 30 KG TO 60 KG (MAX. 70 KG/BATCH) HOURLY CAPACITY: UP TO 240 KG GREEN BEANS/HOUR
SERVICE CENTERS ARE IN SWITZERLAND, ITALY, USA AND INDIA
OPTIONAL FEATURES:
PNEUMATIC FEEDER
PNEUMATIC DESTONER/DISCHARGE UNIT
AFTERBURNER
NOTE: LOADER, DESTONER, AND AFTERBURNER WOULD COST EXTRA. PRICING AVAILABLE WITH QUOTE.QUANTITY: 1
Learn More