Search results for: 'sens'
- Related search terms
- sensor
- SENSOR AS DRY RUN PROTECTION
- sensor tr for sale
- sens'
- sens.ge
-
M-8007 SAMPLE COFFEE ROASTER, CAPACITY 50 TO 200 GRAMSREFERENCE NUMBER: M-8007
SAMPLE COFFEE ROASTER, CAPACITY 50 TO 200 GRAMS
SPECIFICATIONS:
CAPACITY: 50 GRAMS TO 200 GRAMS
POWER: 230V – 50/60HZ
GAS: NATURAL AND PROPANE OR HEATING: ELECTRICAL HEATING
EXHAUST: Ø 80mm
WEIGHT: 85KG
Learn More -
Z-1688 SMALL CHOCOLATE MOULDING ENROBING MACHINEZ-1688 SMALL CHOCOLATE MOULDING ENROBING MACHINE CAPACITY: 8 KG PER BATCH POWER: 500 WATTS ELECTRICAL HEATER INCLUDED DIMENSIONS: 450 x 550 x 500mm QUANTITY: 1 Learn More -
R-3250 GIESEN COFFEE ROASTER AND SELKIRK OXIDIZER - 15 KILOSR-3250 GIESEN COFFEE ROASTER AND SELKIRK OXIDIZER - 15 KILOS
AN EXCEPTIONAL OPPORTUNITY FOR READY TO BE DELIVERED/INSTALLED EQUIPMENT CREATED BY A CHANGED BUSINESS MODEL.
GIESEN W15A
DOUBLE EXHAUST/ROAST PROFILE SYSTEM
NATURAL GAS
240V/60 HZ
COLOR: RED
AVAILABLE WITH SELKIRK TO-2CS321 THERMAL OXIDIZER (USED)GIESEN BROCHURE
SPECIFICATIONS:
GIESEN W15A
CAPACITY: 500 GRAM - 15 KG GREEN BEANS / PER BATCH / M. 60 KG/H
DRIVES: DIRECT FREQUENCY DRIVE MOTOR. ADJUSTABLE DRUM SPEED CONTROL AND ADJUSTABLE ROAST FAN SPEED CONTROL.
ROAST DRUM: DIGITAL PRESSION CONTROL. CAST IRON DRUM WITH HIGH PERFORMANCE BEARINGS.
HEATING SYSTEM: GAS BURNER BY PROPANE GAS (LPG, BOTTLE GAS) OR CITY GAS.
VOLTAGE: 1 PHASE 230V / 50-60 HZ
PAINTING: FREE CHOICE AND CUSTOMIZED / RAL CODES
ROAST ROOF: FREE CHOICE AND CUSTOMIZED
DIMENSIONS: LENGTH 1900mm X WIDTH 962mm X HEIGHT 2000mm
EXHAUST PIPE: EXHAUST PIPE DIAMETER FOR ROAST AIR: ∅ 200mmTHERMAL OXIDIZER FOR GIESEN W15 ROASTER
SELKIRK SPECIALIZES IN THERMAL AFTERBURNERS FOR COFFEE ROASTING MACHINES FROM 10 TO 120 KGS PER BATCH. AFTERBURNERS ARE DESIGNED OF QUALITY MATERIALS FOR LONG SERVICE LIFE. INTEGRATED EFFICIENT GAS BURNERS WHICH REDUCE OPERATING COSTS. BURNER CONFORMS TO UL 295 STANDARD FOR COMMERCIAL/INDUSTRIAL GAS BURNERS. AFTERBURNER DESIGN PROVIDES LONG RETENTION TIMES TO ELIMINATE SMOKE AND ODORS FROM THE ROASTING PROCESS. STANDARD AFTERBURNER OPERATING TEMPERATURE IS 1250 F, BUT CAN EASILY BE ADJUSTED TO MEET LOCAL AIR QUALITY REQUIREMENTS. GAS BURNER IS COMPLETELY SELF MODULATING, AND OPERATOR CONTROLS ARE DESIGNED FOR EASE OF USE.OXIDIZER SPECIFICATIONS:
TO-2CS321 THERMAL OXIDIZER WITH THE FOLLOWING DESIGN FEATURES:
WAYNE COMBUSTION LC 1500 BURNER WITH 1.5 MILLION BTU PER HOUR MAXIMUM INPUT.
DUNGS MULTIBLOC SAFETY VALVE MBC VEF 2500.
DUNGS LOW AND HIGH GAS PRESSURE SWITCHES.
SIEMENS LME SERIES FLAME SAFETY CONTROLLER.
FLAME SENSING ROD FOR FLAME VERIFICATION.
FULLY MODULATING TO MODULATE AT PRE-SET OPERATING TEMPERATURE;
BURNER AND CONTROLS CONFORM TO UL 295 STANDARD FOR COMMERCIAL INDUSTRIAL GAS HEATING EQUIPMENT.
OPERATOR FRIENDLY CONTROL SYSTEM.
TO-2CS321 DIMENSIONS:
OUTSIDE DIAMETER: 36"
OVERALL HEIGHT FROM FLOOR: 82"
INLET DIAMETER: 6"
OUTLET DIAMETER: 10"
EXTERIOR TO BE POWDERCOATED CARBON STEEL MATTE BLACK (OPTIONAL COLORS AVAILABLE).
4" OF HIGH DENSITY CERAMIC INSULATION BETWEEN INTERIOR AND EXTERIOR SURFACES.QUANTITY: 1
Learn More -
R-3249 GIESEN COFFEE ROASTER W15A SELKIRK OXIDIZER - 15 KILOSR-3249 GIESEN COFFEE ROASTER W15A SELKIRK OXIDIZER - 15 KILOS
AN EXCEPTIONAL OPPORTUNITY FOR READY TO BE DELIVERED/INSTALLED EQUIPMENT CREATED BY A CHANGED BUSINESS MODEL.
NATURAL GAS
240V/60 HZ
BLACK/SILVERSELKIRK SPECIALIZES IN THERMAL AFTERBURNERS FOR COFFEE ROASTING MACHINES FROM 10 TO 120 KGS PER BATCH. AFTERBURNERS ARE DESIGNED OF QUALITY MATERIALS FOR LONG SERVICE LIFE. INTEGRATED EFFICIENT GAS BURNERS WHICH REDUCE OPERATING COSTS. BURNER CONFORMS TO UL 295 STANDARD FOR COMMERCIAL/INDUSTRIAL GAS BURNERS. AFTERBURNER DESIGN PROVIDES LONG RETENTION TIMES TO ELIMINATE SMOKE AND ODORS FROM THE ROASTING PROCESS. STANDARD AFTERBURNER OPERATING TEMPERATURE IS 1250 F, BUT CAN EASILY BE ADJUSTED TO MEET LOCAL AIR QUALITY REQUIREMENTS. GAS BURNER IS COMPLETELY SELF MODULATING, AND OPERATOR CONTROLS ARE DESIGNED FOR EASE OF USE.
OXIDIZER SPECIFICATIONS:
TO-2CS321 THERMAL OXIDIZER WITH THE FOLLOWING DESIGN FEATURES:
WAYNE COMBUSTION LC 1500 BURNER WITH 1.5 MILLION BTU PER HOUR MAXIMUM INPUT.
DUNGS MULTIBLOC SAFETY VALVE MBC VEF 2500.
DUNGS LOW AND HIGH GAS PRESSURE SWITCHES.
SIEMENS LME SERIES FLAME SAFETY CONTROLLER.
FLAME SENSING ROD FOR FLAME VERIFICATION.
FULLY MODULATING TO MODULATE AT PRE-SET OPERATING TEMPERATURE;
BURNER AND CONTROLS CONFORM TO UL 295 STANDARD FOR COMMERCIAL INDUSTRIAL GAS HEATING EQUIPMENT.
OPERATOR FRIENDLY CONTROL SYSTEM.
TO-2CS321 DIMENSIONS:
OUTSIDE DIAMETER: 36"
OVERALL HEIGHT FROM FLOOR: 82"
INLET DIAMETER: 6"
OUTLET DIAMETER: 10"
EXTERIOR TO BE POWDERCOATED CARBON STEEL MATTE BLACK (OPTIONAL COLORS AVAILABLE).
4" OF HIGH DENSITY CERAMIC INSULATION BETWEEN INTERIOR AND EXTERIOR SURFACES.QUANTITY: 1
Learn More -
A-1775 VANA 4440 LITRE STAINLESS STEEL PRESSURIZED CHOCOLATE TANKREFERENCE NUMBER: A-1775
VANA 4440 LITRE STAINLESS STEEL PRESSURIZED CHOCOLATE TANK
YEAR: 1998
WITH RB 4500 / NDK AGITATOR (2007)
JACKETED WITH ELECTRIC HEATING
TEMPERATURE SENSOR
QUANTITY: 1
Learn More -
C-3984 CARLE MONTANARI TAN15 SCREW-TYPE TEMPERING MACHINE FOR CHOCOLATE, YEAR 1980C-3984 CARLE MONTANARI TAN15 SCREW-TYPE TEMPERING MACHINE FOR CHOCOLATE, YEAR 1980
CARLE MONTANARI SCREW-TYPE TEMPERING MACHINE
MODEL: TAN15
YEAR: 1980
FOR CHOCOLATEQUANTITY: 1
Learn More