Search results for: '1"'`--".(((.(,'('[0]''
-
T-6552 MASK AIR TIGHTNESS TESTERREFERENCE NUMBER: T-6552
MASK AIR TIGHTNESS TESTER
MASK AIR TIGHTNESS TESTER
HOW TO CHOOSE A HIGH-QUALITY MASK NOT ONLY DEPENDS ON THE FILTERING EFFICIENCY OF THEMASK, BUT ALSO TO CONFIRM WHETHER THE MASK IS COMPLETELY IN CONTACT WITH THE FACE, OTHERWISE AEROSOL PARTICLES SUCH AS GERMS THAT HAVE NOT BEEN FILTERED BY THE MASK WILL BE INHALED FROM THE INADEQUATE ADHESION. THEREFORE, IT IS VERY IMPORTANT TO CHECK THE WEARING STATUS OF THE MASK. THE EUROPEAN AND AMERICAN COUNTRIES HAVE LISTED THE APPLICATION TEST OF THE MASK AS A STRONG INSPECTION ITEM.
FOR EXAMPLE, THE N95 MASK IS ONE OF 9 TYPES OF PARTICULATE PROTECTIVE MASKS CERTIFIED BY NIOSH (NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH). "N" INDICATES OIL RESISTANCE."95" INDICATES THAT THE PARTICLE CONCENTRATION IN THE MASK IS MORE THAN 95% LOWER THAN THAT OF THE PARTICLES OUTSIDE THE MASK WHEN EXPOSED TO THE SPECIFIED NUMBER OF SPECIAL TEST PARTICLES. N95 IS NOT A SPECIFIC PRODUCT NAME, AS LONG AS IT MEETS THE N95 STANDARD AND PASSES THE NIOSH REVIEW, IT CAN BE CALLED "N95 MASK".
N95 TYPE MASKS, IN ADDITION TO THE FILTERING EFFICIENCY OF THE MASKS, THE CLOSENESS OF THE MASKS TO THE FACE IS ONE OF THE IMPORTANT FACTORS THAT DETERMINE THE EFFECTIVENESS OF THE USE OF THE MASKS. THE SUITABILITY OF DIFFERENT TYPES OF MASKS FOR THE HUMAN FACE VARIES GREATLY.
THEREFORE, BEFORE USING A MASK, THE SUITABILITY OF THE MASK SHOULD BE CHECKED FIRST. DURING THETIGHTNESS TEST OF THE WEARER'S FACE, ENSURE THAT AIR CAN PASS IN AND OUT THROUGH THE MASK WHEN IT IS CLOSE TO THE EDGE OF THE FACE. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTION PERFORMANCE. IT CONFORMS TO THE CHINESE RESPIRATOR STANDARD GB2626-2019 STANDARD, OSHA / CSA STANDARD AND CHINA GENERAL ADMINISTRATION OF QUALITY SUPERVISION, INSPECTION AND QUARANTINE "GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS" JOINTLY ISSUED BY THE CHINA NATIONAL STANDARDIZATION ADMINISTRATION COMMITTEE.
ADHESION (SUITABILITY TEST): THE MASK DESIGN SHOULD PROVIDE GOOD ADHESION. THE OVERALL FIT FACTOR OF THE MASK SHOULD NOT BE LESS THAN 100. THIS TEST THE REQUIREMENTS WERE FORMALLY IMPLEMENTED ON AUGUST 1, 2011.
Learn MoreMASK TIGHTNESS TESTER USES CNC TECHNOLOGY, SUITABLE FOR 100 / 99 / P3 / HEPASERIES MASKS DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING DISPOSABLE DUST MASKS SUCH ASN95 / N90 / KN95), GAS MASKS / BREATHING MASKS, ADHESIVENESS TEST OF HALF-MASK AND FULL FACE MASK, INDEPENDENT OR COMPUTER CONTROL, FIVE LANGUAGES SWITCH DISPLAY, EQUIPPED WITH MULTIPLE COMMUNICATION INTERFACES (USB, ETHERNET), WIFI CAN ALSO BE ENABLED, ONE COMPUTERCAN CONTROL FOUR INSTRUMENTS AT THE SAME TIME.PARAMETER:CONCENTRATION RANGE: 0 ~ 100,000 / CM3GRAIN DIAMETER: 0.02 ~ 1.0^MFLOW: SAMPLING FLOW: 100CM3 / MINTOTAL FLOW: 700CM3 / MINCLOSENESS COEFFICIENT TEST: DIRECT TEST (COUT/ CIN)LIQUOR: 99.5% + ISOPROPANOL (ANALYTICAL GRADE)DISPLAY: 7INCH TRUE COLOR TOUCH SCREENCOMMUNICATION INTERFACE: USB X 3 (HOST X 2,DEVICE X 1) ETHERNET INTERFACE X1CONNECTION PORT: ENVIRONMENT PORT, SAMPLING PORTWIFI: EQUIPPEDLANGUAGES: ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESEFLOW CONTROL: SENSOR CONTROLPC CONTROLLABLE OPERATION: ONE COMPUTER CAN CONTROL 4 INSTRUMENTS AT THE SAME TIMEDATA OUTPUT FORMAT: MICROSOFT EXCELWORKING TEMPERATURE: 15 ~ 35 °CPOWER SOURCE: AC 110 —240V 50 / 60HZAPPEARANCE SIZE: 208 X 117 X 262MMWEIGHT: 2.1KGACCESSORIES: ALCOHOL REAGENT BOTTLE, PROTECTIVE CAP, REAGENT STICK, ZERO-COUNT FILTER, STRAINER, SAMPLING TUBE, INSTRUCTION MANUAL, AC ADAPTER, TOUCH SCREEN PEN, OPTIONAL COMPUTER.OPTIONAL: TEST KIT FOR TIGHTNESS COEFFICIENTIN ORDER TO PREVENT INFECTION AT THE MEDICAL SITE AND DURING LABOR WORK, WORKERS MUST BE PROTECTED FROM INHALABLE HAZARDOUS SUBSTANCES IN THE WORKPLACE, AND RESPIRATORS SUCH AS MASKS MUST BE WORN DURING WORK.SELECT A RESPIRATOR, SUCH AS A MASK, BASED ON YOUR FACIAL FEATURES, AND EVALUATE THE TIGHTNESS BETWEEN THE RESPIRATOR, SUCH AS A MASK AND THE FACE, TO CHECK WHETHER THERE ARE GAPS OR LEAKS THAT PUT WORKERS AT RISK. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTIVE PERFORMANCE. SECURITY EXPERTS WILL ALSO DEVELOP PROTECTION SCHEMES AND STANDARD REGULATIONS BASED ON THE RESULTS OF THE TIGHTNESS TEST. WIDELY USED IN HOSPITALS, MANUFACTURING PLANTS, PRODUCTION SITES, FIREFIGHTING WORKPLACES AND OTHER OFFICIAL TESTING AGENCIES.MASK TIGHTNESS TESTER FEATURES:• QUANTITATIVE TIGHTNESS TEST FOR RESPIRATORS SUCH AS MASKS (QNFT)• APPLICABLE TO 100/99 / P3 / HEPA SERIES MASK DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING N95 / N90 / KN95 AND OTHER DISPOSABLE DUST MASKS)• ADHESION TEST OF HALF MASK AND FULL FACE MASK• GAS MASK TIGHTNESS TEST• PAPR MASK TIGHTNESS TEST• SCBA RESPIRATOR MASK TIGHTNESS TEST• 7INCH TRUE COLOR TOUCH SCREEN• INDEPENDENT OR COMPUTER CONTROLLED• USING CNC TECHNOLOGY• ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESE LANGUAGE SWITCHING DISPLAY• COMPLIES WITH US OSHA STANDARDS, CANADIAN STANDARDS ASSOCIATION (CSA) GUIDELINES, INCLUDING N95• EQUIPPED WITH A VARIETY OF COMMUNICATION INTERFACES (USB, ETHERNET), AND CAN ALSO ENABLE WIFI• ONE COMPUTER CAN CONTROL FOUR INSTRUMENTS AT THE SAME TIMEQUANTITY: 1 -
M-3747 STORK TC171 TRANSFER PRINTER 1800mm YEAR 1982REFERENCE NUMBER: M-3747 (99015HBE8RX)-D STORK TC171 TRANSFER PRINTER 1800mm YEAR 1982 MAKE: STORK MODEL: TC171 WIDTH 1800mm YEAR 1982 CYLINDER DIA 1800mm 35 M/MIN WITH THERMIC OIL BOILER (GAS-/OIL-HEATED ~200,000 KCAL) QUANTITY AVAILABLE: 1 Learn More -
TEXPA HEMMING AND LABEL SEWING MACHINES, MODEL QRSN RUNNING TERRYREFERENCE NUMBER: L-6890 TEXPA HEMMING AND LABEL SEWING MACHINES, MODEL QRSN RUNNING TERRY ITEM 001 TEXPA LONGITUDINAL HEMMING MACHINE YEAR 2005 QUANTITY: 1 ITEM 002 TEXPA CROSS HEMMING AND LABEL SEWING MACHINE YEAR: 2005 MODEL: QRSN POSSIBILE TO SEW THREE TYPES OF LABELS: U, V, FLAG PFAFF SEWING MACHINES EQUIPPED FOR TERRY TOWEL WORKING WIDTH: 300mm TO 2000mm QUANTITY: 1 STATUS: STOPPED, NOT DISMANTLED DELIVERY: DISMANTLING AND LOADING WILL NEED 3 WEEKS, REQUIRES TWO 40 FT CONTAINERS TO SHIP Learn More -
ZELLWEGER USTER DELTA 200 DRAWING MACHINE, YEAR 1992REFERENCE NUMBER: T-6974 ZELLWEGER USTER DELTA 200 DRAWING MACHINE, YEAR 1992 MANUFACTURER: ZELLWEGER USTER TYPE: DELTA 200 YEAR: 1992 WORKING WIDTH: 2 X 2000mm OR 3900mm (DOUBLE WIDTH) 3 WARP BEAMING FRAMES TYPE USTERDELTA WITH EXTRA TREE INSTALLATION CREEL APPROX. 200,000 DROPPERS & HEDDLES EXTRA BEAMING CREEL AND ACCESSORIES QUANTITY: 1 Learn More -
THIBEAU/AUTOMATEX/TECNOTEX/FOR DOFFER CARDS AND CROSS-LAPPERSREFERENCE NUMBER: T-6878 THIBEAU/AUTOMATEX/TECNOTEX/FOR DOFFER CARDS AND CROSS-LAPPERS ITEM 001 THIBEAU SINGLE DOFFER CARD YEAR: 1982 WORKING WIDTH: 2500mm AVANTRAIN + 1 SWIFT UP TO 200 KG/H QUANTITY: 1 + AUTOMATEX CROSS-LAPPER YEAR: 1982 INPUT: 2500mm OUTPUT: 5000mm QUANTITY: 1 ITEM 002 TECNOTEX DOUBLE DOFFER CARD YEAR: 2001 WORKING WIDTH: 3500mm QUANTITY: 1 + AUTOMATEX CROSS-LAPPER YEAR: 2001 INPUT: 3500mm OUTPUT: 4000mm QUANTITY: 1 ITEM 003 TECNOTEX DOUBLE DOFFER CARD YEAR: 2000 WORKING WIDTH: 3500mm AVANTRAIN + 2 SWIFTS QUANTITY: 1 + AUTOMATEX FA5000/TC CROSS-LAPPER YEAR: 2000 INPUT: 3600mm OUTPUT: 4500mm UP TO 80 M/MIN QUANTITY: 1 ITEM 004 FOR DOUBLE DOFFER CARD YEAR: 1990S WORKING WIDTH: 2500mm AVANTRAIN + 2 SWIFTS UP TO 500 KG/H + FOR CROSS-LAPPER YEAR: 1990S INPUT: 2500mm OUTPUT: 3800mm QUANTITY: 1 Learn More -
T-6582 MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)REFERENCE NUMBER: T-6582
MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)
MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)
1.NP3030: MEDICAL DISPOSABLE PROTECTIVE CLOTHING,STRONG RESISTANT
2.FABRIC: SF 66 G, COLOR: WHITE RUBBER:CAP/FOOT/CUFF/WAIST FRONT FLAP: DOUBLE-SIDED TAPE, TAPE:BLUE TAPE, ETHYLENE OXIDE DISINFECTION, STERILE
3.PACKAGED: 1PC/BAG, 32PCS/CARTON,10KG/CARTONCARTON SIZE: 470 X300 X420mm/CTN
4.NOTE: CLASS II MEDICAL TREATMENT, SCOPE OF USE: MEDICALPERSONNEL CONTACT WITH POTENTIALLY INFECTIOUS PATIENTSBLOOD, BODY FLUIDS, SECRETIONS, PARTICLES IN THE AIR TOPROVIDE BARRIER, PROTECTION. THIS PRODUCT IS USED FORISOLATION OF OBSERVATION WARD (ROOM), ISOLATION WARD(ROOM), ETC. IT IS STRICTLY PROHIBITED TO USE IN THE ISOLATIONCRITICAL CARE WARD (ROOM) AND OTHER PLACES WITH STRICTCONTROL OF MICROBIAL INDICATORS1PC/BAG, 32PCS/CARTON.
WEIGHT AND DIMENSIONS OF CARTONS: 10KG/CARTON
CARTONS IN A 20 FOOT CONTAINER: 370 BOXESSTERILIZED BY ETHYLENE OXIDE GAS
EACH PIECE IS INDIVIDUALLY VACUUM PACKED
1PER PLASTIC POUCH
QUANTITY: 10,000
Learn More -
T-6560 NON-STERILIZATION AND STERILIZATION PROTECTIVE CLOTHINGAVAILABILITY: NON-STERILE 740CTNS/ 29600PCS, STERILE 720CTNS/ 14400PCS
STERILE TYPE: 1PC PER BAG, 20 BAGS PER CARTON
NON-STERILE TYPE: 1PC PER BAG, 40 BAGS PER CARTON
WEIGHT AND DIMENSIONS OF CARTONS:
STERILE TYPE: 510 X 370 X 380mm, WEIGHT IS AROUND 6.5KG
NON-STERILE TYPE: CARTON SIZE: 560 X 350 X 350mm, WEIGHT IS AROUND 10.4KG
NO PALLET
CARTONS IN A 20 FOOT CONTAINER:
STERILE TYPE: 720 CARTONS/20'GP
NON-STERILE TYPE: 740 CARTONS/20'GP
STANDARD MATERIAL OF PROTECTIVE CLOTHINGNON-STERILIZATION PROTECTIVE CLOTHING
MODEL: RS-PTCL-M175 OR RS-PTCL-L180 OR RS-PTCL-XL185
ITEM 001
QUANTITY: 1000 PCS
ITEM 002
QUANTITY: 10000 PCSSTERILIZATION PROTECTIVE CLOTHING
Learn More
MODEL: RS-PTCL-M175-S OR RS-PTCL-L180-S OR RS-PTCL-XL185-S
ITEM 003
QUANTITY: 1000 PCS
ITEM 004
QUANTITY: 10000 PCS -
L-1736 FEMCO HORIZONTAL FOAM SAW MODEL 4A6 75” WIDE BLADEREFERENCE NUMBER: L-1736
Learn More
MODEL 4A6
QUANTITY: 1 -
A-1549 SCHLAFHORST 238 AUTO CONER, TYPE 147 RMA-1549 SCHLAFHORST 238 AUTO CONER, TYPE 147 RM
AUTO CONER
BRAND: SCHLAFHORST
MODEL: 238
TYPE: 147 RM
MAGAZINE
60 DRUMS
DRUMS TYPE/TURNS: 2.5
ALUMINUM DRUMS
MC HAND: LHx1, RHx1
TYPE OF FEED: RM
QUANTUM C15 F23
SPLICER: D23
TAKE UP CONE: 5°57”
380V, 50Hz
STILL RUNNINGQUANTITY: 2 SETS
Learn More -
C-2575 WARTSILA GENERATORS, YEAR 1994 TO 2012C-2575 WARTSILA GENERATORS, YEAR 1994 TO 2012
ITEM 001
WARTSILA W 20V
MODEL: W 20V
OUTPUT (MW): 8.8
NATURAL GAS
COMPLETE POWER PLANT
11 KV
INCL. 4
STEAM BOILERS WITH 13 BAR
AND 4.7 T/H COOLERS
TRANSFORMERS
50 HZ
34 SG
YEAR: 2005
RUNNING HOURS: 50000
GOOD CONDITIONQUANTITY: 4
ITEM 002
WARTSILA W20
MODEL: W20
OUTPUT (MW): 8.7
DUAL FUEL ENGINES
50 HZ
V34 DF
YEAR: 2012
RUNNING HOURS: ZERO
NEWQUANTITY: 6
ITEM 003
WARTSILA 8L32
MODEL: 8L32
OUTPUT (MW): 3.84
HFO ENGINE
YEAR: 2009
RUNNING HOURS: ZEROQUANTITY: 6
ITEM 004
WARTSILA 33V16S6D
MODEL: 33V16S6D
OUTPUT (MW): 2
DIESEL ENGINE
50 HZ
YEAR: 1994
RUNNING HOURS: 7597QUANTITY: 1
ITEM 005
WARTSILA SACM SDRG 150 V12 S4D
MODEL: SACM SDRG 150 V12 S4D
OUTPUT (MW): 0.53
DIESEL ENGINE
50 HZ
YEAR: 1996
RUNNING HOURS: 560QUANTITY: 1
Learn More