Search results for: 'GAS IN'
-
T-6552 MASK AIR TIGHTNESS TESTERREFERENCE NUMBER: T-6552
MASK AIR TIGHTNESS TESTER
MASK AIR TIGHTNESS TESTER
HOW TO CHOOSE A HIGH-QUALITY MASK NOT ONLY DEPENDS ON THE FILTERING EFFICIENCY OF THEMASK, BUT ALSO TO CONFIRM WHETHER THE MASK IS COMPLETELY IN CONTACT WITH THE FACE, OTHERWISE AEROSOL PARTICLES SUCH AS GERMS THAT HAVE NOT BEEN FILTERED BY THE MASK WILL BE INHALED FROM THE INADEQUATE ADHESION. THEREFORE, IT IS VERY IMPORTANT TO CHECK THE WEARING STATUS OF THE MASK. THE EUROPEAN AND AMERICAN COUNTRIES HAVE LISTED THE APPLICATION TEST OF THE MASK AS A STRONG INSPECTION ITEM.
FOR EXAMPLE, THE N95 MASK IS ONE OF 9 TYPES OF PARTICULATE PROTECTIVE MASKS CERTIFIED BY NIOSH (NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH). "N" INDICATES OIL RESISTANCE."95" INDICATES THAT THE PARTICLE CONCENTRATION IN THE MASK IS MORE THAN 95% LOWER THAN THAT OF THE PARTICLES OUTSIDE THE MASK WHEN EXPOSED TO THE SPECIFIED NUMBER OF SPECIAL TEST PARTICLES. N95 IS NOT A SPECIFIC PRODUCT NAME, AS LONG AS IT MEETS THE N95 STANDARD AND PASSES THE NIOSH REVIEW, IT CAN BE CALLED "N95 MASK".
N95 TYPE MASKS, IN ADDITION TO THE FILTERING EFFICIENCY OF THE MASKS, THE CLOSENESS OF THE MASKS TO THE FACE IS ONE OF THE IMPORTANT FACTORS THAT DETERMINE THE EFFECTIVENESS OF THE USE OF THE MASKS. THE SUITABILITY OF DIFFERENT TYPES OF MASKS FOR THE HUMAN FACE VARIES GREATLY.
THEREFORE, BEFORE USING A MASK, THE SUITABILITY OF THE MASK SHOULD BE CHECKED FIRST. DURING THETIGHTNESS TEST OF THE WEARER'S FACE, ENSURE THAT AIR CAN PASS IN AND OUT THROUGH THE MASK WHEN IT IS CLOSE TO THE EDGE OF THE FACE. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTION PERFORMANCE. IT CONFORMS TO THE CHINESE RESPIRATOR STANDARD GB2626-2019 STANDARD, OSHA / CSA STANDARD AND CHINA GENERAL ADMINISTRATION OF QUALITY SUPERVISION, INSPECTION AND QUARANTINE "GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS" JOINTLY ISSUED BY THE CHINA NATIONAL STANDARDIZATION ADMINISTRATION COMMITTEE.
ADHESION (SUITABILITY TEST): THE MASK DESIGN SHOULD PROVIDE GOOD ADHESION. THE OVERALL FIT FACTOR OF THE MASK SHOULD NOT BE LESS THAN 100. THIS TEST THE REQUIREMENTS WERE FORMALLY IMPLEMENTED ON AUGUST 1, 2011.
Learn MoreMASK TIGHTNESS TESTER USES CNC TECHNOLOGY, SUITABLE FOR 100 / 99 / P3 / HEPASERIES MASKS DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING DISPOSABLE DUST MASKS SUCH ASN95 / N90 / KN95), GAS MASKS / BREATHING MASKS, ADHESIVENESS TEST OF HALF-MASK AND FULL FACE MASK, INDEPENDENT OR COMPUTER CONTROL, FIVE LANGUAGES SWITCH DISPLAY, EQUIPPED WITH MULTIPLE COMMUNICATION INTERFACES (USB, ETHERNET), WIFI CAN ALSO BE ENABLED, ONE COMPUTERCAN CONTROL FOUR INSTRUMENTS AT THE SAME TIME.PARAMETER:CONCENTRATION RANGE: 0 ~ 100,000 / CM3GRAIN DIAMETER: 0.02 ~ 1.0^MFLOW: SAMPLING FLOW: 100CM3 / MINTOTAL FLOW: 700CM3 / MINCLOSENESS COEFFICIENT TEST: DIRECT TEST (COUT/ CIN)LIQUOR: 99.5% + ISOPROPANOL (ANALYTICAL GRADE)DISPLAY: 7INCH TRUE COLOR TOUCH SCREENCOMMUNICATION INTERFACE: USB X 3 (HOST X 2,DEVICE X 1) ETHERNET INTERFACE X1CONNECTION PORT: ENVIRONMENT PORT, SAMPLING PORTWIFI: EQUIPPEDLANGUAGES: ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESEFLOW CONTROL: SENSOR CONTROLPC CONTROLLABLE OPERATION: ONE COMPUTER CAN CONTROL 4 INSTRUMENTS AT THE SAME TIMEDATA OUTPUT FORMAT: MICROSOFT EXCELWORKING TEMPERATURE: 15 ~ 35 °CPOWER SOURCE: AC 110 —240V 50 / 60HZAPPEARANCE SIZE: 208 X 117 X 262MMWEIGHT: 2.1KGACCESSORIES: ALCOHOL REAGENT BOTTLE, PROTECTIVE CAP, REAGENT STICK, ZERO-COUNT FILTER, STRAINER, SAMPLING TUBE, INSTRUCTION MANUAL, AC ADAPTER, TOUCH SCREEN PEN, OPTIONAL COMPUTER.OPTIONAL: TEST KIT FOR TIGHTNESS COEFFICIENTIN ORDER TO PREVENT INFECTION AT THE MEDICAL SITE AND DURING LABOR WORK, WORKERS MUST BE PROTECTED FROM INHALABLE HAZARDOUS SUBSTANCES IN THE WORKPLACE, AND RESPIRATORS SUCH AS MASKS MUST BE WORN DURING WORK.SELECT A RESPIRATOR, SUCH AS A MASK, BASED ON YOUR FACIAL FEATURES, AND EVALUATE THE TIGHTNESS BETWEEN THE RESPIRATOR, SUCH AS A MASK AND THE FACE, TO CHECK WHETHER THERE ARE GAPS OR LEAKS THAT PUT WORKERS AT RISK. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTIVE PERFORMANCE. SECURITY EXPERTS WILL ALSO DEVELOP PROTECTION SCHEMES AND STANDARD REGULATIONS BASED ON THE RESULTS OF THE TIGHTNESS TEST. WIDELY USED IN HOSPITALS, MANUFACTURING PLANTS, PRODUCTION SITES, FIREFIGHTING WORKPLACES AND OTHER OFFICIAL TESTING AGENCIES.MASK TIGHTNESS TESTER FEATURES:• QUANTITATIVE TIGHTNESS TEST FOR RESPIRATORS SUCH AS MASKS (QNFT)• APPLICABLE TO 100/99 / P3 / HEPA SERIES MASK DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING N95 / N90 / KN95 AND OTHER DISPOSABLE DUST MASKS)• ADHESION TEST OF HALF MASK AND FULL FACE MASK• GAS MASK TIGHTNESS TEST• PAPR MASK TIGHTNESS TEST• SCBA RESPIRATOR MASK TIGHTNESS TEST• 7INCH TRUE COLOR TOUCH SCREEN• INDEPENDENT OR COMPUTER CONTROLLED• USING CNC TECHNOLOGY• ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESE LANGUAGE SWITCHING DISPLAY• COMPLIES WITH US OSHA STANDARDS, CANADIAN STANDARDS ASSOCIATION (CSA) GUIDELINES, INCLUDING N95• EQUIPPED WITH A VARIETY OF COMMUNICATION INTERFACES (USB, ETHERNET), AND CAN ALSO ENABLE WIFI• ONE COMPUTER CAN CONTROL FOUR INSTRUMENTS AT THE SAME TIMEQUANTITY: 1 -
J-2640 DYEING AND FINISHING PLANT FOR SALEREFERENCE NUMBER: J-2640
DYEING AND FINISHING PLANT FOR SALEITEM 001
THIES SAMPLE DYEING MACHINE
MODEL: MINISOFT SAMPLE
CAPACITY: 50 KGS
YEAR: 1999
MICROPROCESSOR CONTROLLED
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING REEL AND FABRIC EXIT PLAITOR
QUANTITY: 1ITEM 002
THIES DYEING MACHINE
MODEL ECOSOFT PLUS
3 PORT SPLIT/SPLIT
CAPACITY: 900 KGS
YEAR: 1999
MICROPROCESSOR CONTROLLED
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING REEL AND FABRIC EXIT PLAITOR
QUANTITY: 1ITEM 003
THIES DYEING MACHINE
MODEL: ECOSOFT PLUS
2 PORT SPLIT/SPLIT
CAPACITY: 600 KGS
YEAR: 1999
MICROPROCESSOR CONTROL
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING REEL AND FABRIC EXIT PLAITOR
QUANTITY: 1ITEM 004
THIES DYEING MACHINE
MODEL ECOSOFT PLUS
1 PORT SPLIT/SPLIT
CAPACITY: 300 KGS
YEAR: 1999
MICROPROCESSOR CONTROLLED
VOLTAGE: A460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING REEL AND FABRIC EXIT PLAITOR
QUANTITY: 1ITEM 005
GASTON COUNTY DYEING MACHINE
MODEL: AQUAFLOW
2 PORT
CAPACITY; 250 KGS
YEAR: 1987
MICROPROCESSOR CONTROLLED
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING AND UNLOADING REEL
QUANTITY: 1ITEM 006
THIES DYEING MACHINE
MODEL: SOFT TRD
2 TUBE
CAPACITY: 700 KGS
YEAR: 1999
MICROPROCESSOR CONTROLLED
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING REEL AND FABRIC EXIT PLAITOR
QUANTITY: 1ITEM 007 (also our J-2647)
LAFER OPEN WIDTH COMPACTOR MACHINE
MODEL: KSA 500 2400/2200
YEAR: 1998
LAFER TEXEN CONTROLS
VOLTAGE: 480 VOLTS, 3-PHASE, 60 Hz
COMPOSED OF:
• TENSION BAR ENTRY TO LATTICE ROLL GUIDER
• OPERATOR’S PLATFORM
• PUP TENTER WITH KNIT ENTRY, VERTICAL PIN CHAIN, WITH PLATE GUIDES, RAIL OPENING, PINNING BRUSHES, PINS ONLY, WITH SUPPORT SECTION FOR THE FABRIC IN THE CENTER, AT 10’ THERE IS A STEAMING SECTION, TOTAL LENGTH OF THE TENTER IS 30’, WITH AUTOMATIC LUBRICATION FOR THE CHAIN
• KSA 500 COMPACTOR BENCH WITH TEXEN CONTROLS
• TENSIONLESS FABRIC CONVEYOR
• PLAITOR AND FABRIC SCRAY WITH OPTICAL LOAD SENSOR
• INLINE INSPECTION BATCHER MACHINE, WITHH A BACK LIGHTED BOARD, MANUAL CUT
• SCALE TO WEIGHT THE FABRIC
QUANTITY: 1ITEM 008 (also our J-2648)
SANTEX TUBULAR 4-ROLL EXTRACTION PAD
MODEL: SANTASTRETCH PLUS 140
YEAR: 1998
COMPOSED OF TURNTABLE, DETWISTER, TUBULAR 4-ROLL PAD WITH WET SPREADERS, PLAITOR
WITH ADDITION TANKS FOR SOFTENER
REEL FABRIC PLAITOR EXIT
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
QUANTITY: 1ITEM 009
SANTEX CONVEYOR DRYER FOR OPEN WIDTH AND TUBULAR FABRIC
MODEL: SANTASHRINK 4/5240
YEAR: 1998
SANTEX CONTROLS
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
COMPOSED OF:
• TENSION BAR ENTRY TO LATTICE ROLL GUIDER TO
• (2) SANTEX 2-ROLL PADS, RUBBER OVER RUBBER, 102” WIDE x 12” DIAMETER, STAINLESS STEEL PAN, 10-TON PAD, SWING-AWAY PAN, TENSION BAR WITH 2 STAINLESS STEEL MIXING TANKS, 75 GALLONS EACH
• DRIVEN SCROLL ROLLS WITH EDGE GUIDE CONTROL, WIDTH 95”
• OPERATOR’S PLATFORM
• PUP TENTER WITH KNIT ENTRY 45°, YEAR 1998, VERTICAL PIN CHAIN, 30’ LONG WITH TANDEMATIC PLATE GUIDES, RAIL GUIDES, PINNING BRUSHES, GUIDE SUPPORT FOR THE FABRIC, FABRIC CONVEYOR TO ENTER BOTH TUBULAR OR OPEN WIDTH FABRIC TO
• CONVEYOR DRYER 100” WIDE, 5 ZONES, 3-PASS WITH MAXON BURNERS, 5 CIRCULATING FANS TO CONVEYOR BELT TO PLAITOR
• ALL MOTORS AND SANTEX CONTROLS AND MONITORS
QUANTITY: 1ITEM 010
SANTEX AG TUBULAR COMPACTOR MACHINE
MODEL: SANTASPREAD 140
YEAR: 1998
SANTEX CONTROLS
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
COMPOSED OF:
• TENSIONS BAR ENTRY
• OPERATOR’S PLATFORM
• TENSION DEVICE
• DRIVEN SPREADER BARS
• STEAMING DEVICE
• TUBULAR COMPACTING BENCH
• FELT BLANKET ONTO THE CONVEYOR BELT
• PRECISION PLAITOR
• TABELTOP ELECTRONIC SCALE
QUANTITY: 1ITEM 011
COMET NAPPER
MODEL: PEGSO-X4
YEAR: 1998
VOLTAGE: 480 VOLTS, 3-PHASE, 60 Hz
24 ROLLS WITH TURNING BARS FOR TUBULAR 90” WIDE
XYCOM CONTROLS
12-BAG COLLECTION SYSTEM AND PLAITOR
YEAR: 1996
QUANTITY: 1ITEM 012
STENTEX TENTER FRAME
MODEL: STENTOTHERM 3300
YEAR: 1999
STENTEX CONTROLS
VOLTAGE: 480 VOLTS, 3-PHASE, 60 Hz
COMPOSED OF:
• TENSION ENTRY TO TEXT-STAR TYPE GUIDER TO 2 ROLL PAD
• ADDITION TANK TOP SCRAY PAD TO TEXT-STAR TYPE GUIDER
• TWO ROLL PAD R/R 10 TON
• OPERATOR’S PLATFORM
• WORKING WIDTH 1800mm
• HORIZONTAL PIN CHAIN, KNIT ENTRY
• TANDEMATIC SPLITLEVEL DECURLERS
• OVERFEED
• PINNING BRUSHES
• STEAM BOX
• RAIL GUIDERS, 20 FEET ENTRY, 8 ZONES
• 80 FEET HOUSING
• SCREEN MONITORS
• GAS FIRED, MAXON OVEPAK 408 BURNERS
• HONEYWELL CONTROLS
• 3 FEET COOLING ZONE
• 2 COOLING CANS, SELVEDGE TRIMMERS
• PLIATOR, SCRAY
• ZONE IN LINE INSPECTION BATCHER
QUANTITY: 1ITEM 013
ZIMMER ROTARY SCREEN PRINTING MACHINE
MODEL: R92-S153
YEAR: 1993
COMPOSED OF:
• TENSION BAR SKY ENTRY
• SCRAY
• CORINO BRUSH
• CORINO PRINT GUIDER
• ZIMMER PRINTER, 8 COLOR, 86” BLANEKT
• PRINT CONVEYOR DRYER, 30’ LONG, 3-ZONE, GAS FIRED
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
QUANTITY: 1ITEM 014
Learn More
SAFETY SWITCH BULLET NOSE SLITTER
MODEL: CUTTING
WITH REEL FABRIC PLIATOR
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
QUANTITY: 1 -
L-5934 MONFORTS 6-F TWIN AIR STENTER YEAR 2003 – WORKING WIDTH 2400mmREFERENCE NUMBER: L-5934
MONFORTS 6-F TWIN AIR STENTER YEAR 2003 – WORKING WIDTH 2400mm
STENTER
RAMA MONFORTS
MAKE: MONFORTS
MODEL: 6-F TWIN
YEAR: 2003
440 VAC 60HZ
NATURAL GAS
AIR COMPRESSOR 7 BAR
QUANTITY: 1
Learn More -
L-4786 WAUKESHA VHP7044GSI GENERATORS, 1200 RPM, 50 & 60 HzL-4786 WAUKESHA VHP7044GSI GENERATORS, 1200 RPM, 50 & 60 Hz
CAN OPERATE AT 1150 KW, 1200 RPM, 60 Hz, 600/480 VAC
Learn More
OR
AT 1050 KW, 1000 RPM, 50 Hz, 400 VAC
WEATHER ENCLOSURE W/SKID
ENGINE DRIVEN RADIATOR ASSEMBLY
ENGINE CONTROLS & INTERFACE: WAUKESHA ENGINE ECU & AUXILIARY I/O BOX
KATO ALTERNATOR, 1200 KW / 1500 KVA, 6P6-3300, 6– POLES, 2 BEARING, 1200 RPM, 80 DEG C TEMP.
RISE (40 DEG. AMBIENT), IP-23 ENCLOSURE, PMG, CLASS 'H', 600/480 VOLT AC DUAL VOLTAGE, 3 PH,60HZ, 0.8 PF. FOUR (4) UNITS WITH
RENOLD COUPLING - 4 UNITS WITH MARATHON ALTERNATOR 480 VAC
ENGINE CONTROLS AND INTERFACE – ECU AND AUXILIARY I/O BOX
50 GALLON OIL MAKE-UP SYSTEM WITH LEVEL INDICATION -
R-1390 OSTHOFF SINGEING/CORINO ENTRY & EXIT/PAREX & DESIZING RANGE, WORKING WIDTH 2000mm, YEAR 1995 - RECONDITIONED 2015REFERENCE NUMBER: R-1390
OSTHOFF SINGEING/CORINO ENTRY & EXIT/PAREX & DESIZING RANGE, WORKING WIDTH 2000mm, YEAR 1995 - RECONDITIONED 2015
DETAILS:
BRAND:OSTHOFF
WORKING WIDTH: 2000mm
YEAR: 1995
FULLY RECONDITIONED IN YEAR: 2015COMPRISING OF:
ITEM 001
CORINO DE- BATCH- J BOX & BRUSH
WORKING WIDTH: 2000mm
QUANTITY: 1ITEM 002
OSTHOFF SINGEING MACHINE
TYPE: PK 90
MAXIMUM FABRIC WIDTH: 2000mm
MAXIMUM FLAME WIDTH: 2200mm
QUANTITY: 1ITEM 003
GAS BURNERS WITH AUTO IGNITION ELECTRODES
WORKING WIDTH: 2000mm
QUANTITY: 2ITEM 004
PAREX DESIZING WITH 2 BOWL PADDER
QUANTITY: 1ITEM 005
Learn More
ONE PAREX OPEN WIDTH DESIZING - WASHING TANK
WORKING WIDTH: 2000mm
QUANTITY: 1 -
M-6053 SPUNBOND PRODUCTION LINE, WORKING WIDTH 4040mm TO 4500mmM-6053 SPUNBOND PRODUCTION LINE, WORKING WIDTH 4040mm TO 4500mm
OFFER 001
SPUNBOND PRODUCTION LINE
WORKING WIDTH: 4040mm
WEIGHT: 130 TO 250 G/M2OFFER 002
POLYMER CLEANING GROUPOFFER 003
CRYSTALLIZING GROUPOFFER 004
DRYING GROUPOFFER 005
PNEUMATIC CONVEYING SYSTEMOFFER 006
EXTRUDER HOPPEROFFER 007
EXTRUDEROFFER 008
FILTERING UNITOFFER 009
MELT TRANSFER LINEOFFER 010
SPINNING BEAMOFFER 011
SPINNING PACKSOFFER 012
FILAMENTS QUENCHING SYSTEMOFFER 013
FILAMENTS DRAWING AND DISTRIBUTION SYSTEMOFFER 014
WEB FORMING CONVEYOR BELTOFFER 015
CREEL FOR APPLICATION OF REINFORCING FILAMENTSOFFER 016
PRE-NEEDLING MACHINEOFFER 017
NEEDLING MACHINEOFFER 018
THERMOSETTING UNITOFFER 019
OUTLET CALENDEROFFER 020
FOULARDOFFER 021
BINDER PREPARATION SYSTEMOFFER 022
DRYEROFFER 023
OUTLET CALENDEROFFER 024
AUTOMATIC WINDEROFFER 025
AIR COMPRESSORS (FOR FILAMENTS STRETCHING EJECTORS)OFFER 026
DIATHERMIC OIL HEATING SYSTEMOFFER 027
CHILLED WATER CIRCULATION AND GENERATION SYSTEMOFFER 028
EQUIPMENT FOR CLEANING CYCLE, SPECIAL TOOLSOFFER 029
FIBRE DUST RECOVERY SYSTEMOFFER 030
EDGES RECOVERY SYSTEMOFFER 031
SPINNING SECTION STEEL STRUCTUREOFFER 032
DISTRIBUTION ELECTRIC CABINETSOFFER 033
PROCESS ELECTRIC SYSTEM OF EXISTING MACHINES ACCORDING TO THE ACTUAL LAYOUTOFFER 034
CABLES AND CABLING MATERIALSQUANTITY: 1 LINE
Learn More -
T-6549 CONSTANT TEMPERATURE AND HUMIDITY CHAMBER -FABRIC WATER VAPOR TRANSMISSION RATEREFERENCE NUMBER: T-6549
CONSTANT TEMPERATURE AND HUMIDITY CHAMBER -FABRIC WATER VAPOR TRANSMISSION RATE
TESTING METER (WITH MOISTURE PERMEABLE CUP)
TECHNICAL DESCRIPTION OF THE INSTRUMENT:
IT IS MAINLY USED TO MEASURE THE MOISTURE PERMEABILITY OF ALL KINDS OF FABRICS, INCLUDING PERMEABLE COATED FABRICS. STRUCTURE PRINCIPLE: ADOPT COMPUTER CONTROL, CREATING A CONSTANT TEMPERATURE, AND HUMIDITY TEST ENVIRONMENT, TEST ENVIRONMENT IN THE CONSTANT TEMPERATURE, AND HUMIDITY, MOISTURE VAPOR TRANSMISSION CUP, PLACED 6 SAMPLE INTO THE GLASS AND THE RUBBER GASKET SEAL, THE CONTAINING HYGROSCOPIC AGENT OR WATER SEAL IS SPECIFIED BY THE WET CUP PLACED IN THE FABRIC SAMPLE TEMPERATURE AND HUMIDITY OF THE ENVIRONMENT, THE SEAL MOISTURE VAPOR TRANSMISSION CUP ACCORDING TO A CERTAIN TIME (INCLUDING SAMPLE AND HYGROSCOPIC AGENT OR WATER) TO CALCULATE THE MOISTURE TRANSMISSION QUALITY CHANGE.
TESTING STANDARD:
GB19082-2009 MEDICAL PRIMARY PROTECTIVE CLOTHING
TECHNICAL REQUIREMENTS GUIDELINES FOR THE SELECTION OF YY-T1498-2016 MEDICAL PROTECTIVE CLOTHING
GB/T12704.1 DETERMINATION OF MOISTURE PERMEABILITY OF FABRICS --HYGROSCOPIC METHOD
DETAILED TECHNICAL SPECIFICATIONS AND CONFIGURATION:
TECHNICAL INDICATORS:
1. TEMPERATURE CONTROL RANGE: -40°C ~ 150°C;RESOLUTION; 0.1 °C
2. HUMIDITY CONTROL RANGE: 50%RH ~ 95% RH±5%
3. SPEED RANGE: 2mm ~ 60mm/MIN
4. CONTROL PRECISION: TEMPERATURE <0.1°C; HUMIDITY + / -1% RH OR LESS
5. CYCLIC WIND SPEED: 0.02 ~ 0.5M/S, 0.3 ~ 0.5M/S
6. TIME CONTROL: 1 ~ 9999H
7. MOISTURE PERMEABLE AREA: 2827 mm 2 (DIAMETER IS 60 mm --NATIONAL STANDARD)
8. QUANTITY OF PERMEABLE CUPS: 6 GB;
9. DRYING BOX CONTROL TEMPERATURE: ROOM TEMPERATURE ~ 199 °C
10. TEST TIME: 1 ~ 999H
11. DRYING BOX STUDIO SIZE: 490 X 400 X 215mm
INSTRUMENT CONFIGURATION:
1. ONE MAIN MACHINE
QUANTITY: 1
Learn More -
M-3674 SANTEX TENTER YEAR 1997-PIN CHAIN -6 ZONESREFERENCE NUMBER: M-3674 (880WUREXX7) L SANTEX TENTER YEAR 1997-PIN CHAIN -6 ZONES QUANTITY AVAILABLE: 1 Learn More -
M-5350 BRUCKNER MULTILAYER STENTER FOR KNIT AND WOVEN FABRIC YEAR 1995 WIDTH 2200mmREFERENCE NUMBER: M-5350 (220LWGPXX1) L BRUCKNER MULTILAYER STENTER FOR KNIT AND WOVEN FABRIC YEAR 1995 WIDTH 2200mm MULTILAYER STENTER MACHINE FOR KNITTING FABRIC AND WOVEN FABRIC MANUFACTURE: BRUECKNER YEAR: 1995 WORKING WIDTH: 2200mm QUANTITY AVAILABLE: 1 Learn More -
KUSTERS CONTINUOUS WASHING MACHINE, WORKING WIDTH 3400mm, YEAR 1996REFERENCE NUMBER: T-6916 KUSTERS CONTINUOUS WASHING MACHINE, WORKING WIDTH 3400mm, YEAR 1996 KUSTERS CONTINUOUS WASHING MACHINE FOR TUULE CURTAIN WASHING- GUIPURE TREATMENT WORKING WIDTH 3400mm ROLLER WIDTH 3600mm YEAR 1996 2 WASHING TANKS 2 KUSTERS SQUEEZING PADDER (ONE WITH S-ROLL FEATURE) 1 CHAMBER DRYING GAS HEATED WELL MAINTAINED WITH ORIGINAL SPARE PARTS SITUATION: INSTALLED AND RUNNING QUANTITY: 1 Learn More