Search results for: 'Machine manual'
- Related search terms
- machine'
- Machine+c
- machine''
- Machine+c'
- machine+de''
- C-1925 SCHLAFHORST AUTOCONER 238 WITH 40 HEADS, YEAR 1995, THERMO SPLICER, USTER QUANTUM 2
C-1925 SCHLAFHORST AUTOCONER 238 WITH 40 HEADS, YEAR 1995, THERMO SPLICER, USTER QUANTUM 2
DETAILS:
HEADS: 40
SPLICER: THERMO SPLICER
CLEARER: USTER QUANTUM 2
YEAR: 1995
FEEDER: MAGAZINE (MANUAL)
OHC ROBOT:YESMACHINES PACKED IN THE FACTORY
NOT RUNNING DUE TO PLANT GETTING NEW MACHINESQUANTITY: 12
Learn More - C-1920 SCHLAFHORST AUTOCONER 238 WITH 60 HEADS, YEAR 1990, THERMOSPLICER- USTER QUANTUM 2
C-1920 SCHLAFHORST AUTOCONER 238 WITH 60 HEADS, YEAR 1990, THERMOSPLICER- USTER QUANTUM 2
DETAILS:
HEADS: 60
SPLICER: THERMO SPLICER
CLEARER: USTER QUANTUM 2
YEAR: 1990
FEEDING: MAGAZINE (MANUAL)
OHC ROBOT: YESMACHINES PACKED IN THE FACTORY
NOT RUNNING DUE TO PLANT GETTING NEW MACHINESQUANTITY: 3
Learn More - C-1919 SCHLAFHORST AUTOCONER 238 WITH 60 HEADS, YEAR 1990, THERMO SPLICER, USTER QUANTUM 2
C-1919 SCHLAFHORST AUTOCONER 238 WITH 60 HEADS, YEAR 1990, THERMO SPLICER, USTER QUANTUM 2
DETAILS:
HEADS: 60
SPLICER: THERMO SPLICER
CLEARER: USTER QUANTUM 2
YEAR: 1990
OHC ROBOT: YES
FEEDING: MAGAZINE (MANUAL)MACHINES PACKED IN THE FACTORY
NOT RUNNING DUE TO PLANT GETTING NEW MACHINESQUANTITY: 1
Learn More - C-1918 SCHLAFHORST AUTOCONER 238 WITH 60 HEADS, YEAR 1990, THERMO SPLICER, USTER QUANTUM 2
C-1918 SCHLAFHORST AUTOCONER 238 WITH 60 HEADS, YEAR 1990, THERMO SPLICER, USTER QUANTUM 2
DETAILS:
HEADS: 60
SPLICER: THERMO SPLICER
CLEARER: USTER QUANTUM 2
YEAR: 1990
FEEDING: MAGAZINE (MANUAL)
OHC ROBOT:YESMACHINES PACKED IN THE FACTORY
NOT RUNNING DUE TO PLANT GETTING NEW MACHINESQUANTITY: 1
Learn More - C-4005 PACTEC NAGEMA EW10 CUT & VIENNA FOLD TYPE BONBON WRAPPER, WIDTH 16 TO 18mm, YEAR 1990
C-4005 PACTEC NAGEMA EW10 CUT & VIENNA FOLD TYPE BONBON WRAPPER, WIDTH 16 TO 18mm, YEAR 1990
YEAR: 1990
300/MIN
WITH BATCH ROLLER & ROPE SIZER
REFURBISHED
PRODUCT DIMENSIONS
LENGTH: 25 TO 35mm
WIDTH: 16 TO 18mmQUANTITY: 1
Learn More - M-5274 RIETER BT-903E OPEN END MACHINES YEAR 2000REFERENCE NUMBER: M-5274 (131342GHB12UE) L RIETER BT-903E OPEN END MACHINES YEAR 2000 OPEN END MACHINES MODEL BT-903E MAKE RIETER YEAR 2000 QUANTITY AVAILABLE: 2 Learn More
- T-6543 MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
REFERENCE NUMBER: T-6543
MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
SHANDONG INDEPENDENTLY RESEARCH AND DEVELOPMENT THIS COMPREHENSIVE TESTING MACHINE FOR SURGICAL MASK & PROTECTIVE CLOTHING, IT IS WIDELY USED IN A VARIETY OF MASK STRENGTH DETECTION PROJECTS.FEATURES:COMPLY WITH NATIONAL STANDARDS, MEDICAL STANDARDS TESTING REQUIREMENTS, AUTOMATIC SOFTWARE CONTROL SYSTEM, MEET THE REQUIREMENTS OF DATA STORAGE, PRINTING, COMPARISON. THE IMPORTED SERVO MOTOR IS EQUIPPED WITH PRECISION SCREW DRIVE SYSTEM TO ENSURE THE STABILITY OF TEST DATA.
TEST STANDARDS:
GB 19082-2009 TECHNICAL REQUIREMENTS FOR DISPOSABLE PROTECTIVE CLOTHING FOR MEDICAL USE (4.5 BREAKING STRENGTH -THE BREAKING STRENGTH OF MATERIALS IN KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 45N)
(4.6 ELONGATION AT BREAK -THE ELONGATION AT BREAK OF KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 15%)
SELF-PRIMING FILTER RESPIRATOR FOR RESPIRATORY PROTECTION ARTICLES5.6.2 BREATHING BONNET -BREATHING BONNET SHALL BE SUBJECT TO AXIAL TENSION"DISPOSABLE MASK: 10N FOR 10S" "REPLACEABLE MASK: 50N FOR 10S"
(5.9 HEADBAND -HEADBAND SHOULD BEAR THE TENSION "DISPOSABLE MASK: 10N, 10S" "REPLACEABLE HALF MASK: 50N FOR 10S" "FULL MASK: 150N FOR 10S")
5.10 JOINTS AND CONNECTING PARTS -JOINTS AND CONNECTING PARTS SHALL BE SUBJECT TO AXIAL TENSION
"REPLACEABLE HALF MASK: 50N FOR 10S" "FULL COVER 250N FOR 10S"
GB/T 32610-2016 TECHNICAL SPECIFICATION FOR DAILY PROTECTIVE MASKS
(6.9 BREAKING STRENGTH OF THE MASK BELT AND THE CONNECTION BETWEEN THE MASK BELT ANDTHE MASK BODY ≥ 20N)
(6.10 FASTNESS TO BREATHING BONNET: NO SLIPPAGE, BREAKAGE OR DEFORMATION SHALL OCCUR)
YY/T 0699-2013 DISPOSABLE SURGICAL MASK
(4.4 MASK BELT -THE BREAKING FORCE AT THE CONNECTION POINT BETWEEN EACH MASK BELT AND THE MASK BODY IS NOT LESS THAN 10N)
YY 0469-2011 SURGICAL MASK FOR MEDICAL USE (5.4.2 MASK BELT)
GB/T 3923.1-1997 DETERMINATION OF BREAKING STRENGTH AND ELONGATION AT BREAK OF FABRICS (STRIP METHOD)
DISPOSABLE RUBBER INSPECTION GLOVES (6.3 TENSILE PROPERTIES)
INSTRUMENT TECHNICAL PARAMETERS:
SPECIFICATION: 200N (STANDARD) 50N, 100N, 500N, 1000N (OPTIONAL)
ACCURACY: BETTER THAN 0.5RESOLUTION OF FORCE VALUE: 0.1N
DEFORMATION RESOLUTION: 0.001mm
TEST SPEED: 0.01mm/MIN ~ 2000mm/MIN (STEPLESS SPEED REGULATION)
WIDTH OF SAMPLE: 30mm (STANDARD FIXTURE) 50mm (OPTIONAL FIXTURE)
CLAMPING OF SAMPLES: MANUAL (PNEUMATIC CLAMPING CAN BE CHANGED)
STROKE: 700mm (STANDARD) 400mm, 1000mm (OPTIONAL)
QUANTITY: 1
Learn More - T-6550 MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTER
REFERENCE NUMBER: T-6550
MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTER
TECHNICAL SPECIFICATIONS AND CONFIGURATION:
1. THE INSTRUMENT ADOPTS AN AIR SOURCE THAT CAN PROVIDE (0.5 ~ 30±0.1) KPA PRESSURE TO CONTINUOUSLY PRESSURIZED THE SAMPLE, WHICH IS NOT RESTRICTED BY THE SPACE OF THE TEST SITE;
2. THE AIR PRESSURE RANGE CAN BE ADJUSTED FREELY, AND THE ADJUSTMENT RANGE (0.5 ~ 30) KPA;
3. COLOR TOUCH SCREEN DISPLAY AND OPERATION;
4. THE SAMPLE CLAMPING PAD IS PROCESSED WITH IMPORTED SPECIAL ALUMINUM PROFILES, WHICH IS LIGHT IN MATERIAL, CLEAN IN SURFACE AND NEVER RUSTS.
5. THE INSTRUMENT ADOPTS IMPORTED SPECIAL ALUMINUM WIRE DRAWING PANEL, EQUIPPED WITH METAL KEYS, SENSITIVE OPERATION, NOT EASY TO DAMAGE;
6. CLAMPING DEVICE FOR INSTRUMENT SAMPLES, EQUIPPED WITH LOCKING PROTECTION, TO PREVENT THE SYNTHETIC BLOOD FROM SPLASHING AROUND;
7. CLAMPING FORCE IS ACCURATE AND RELIABLE;
8. THE TEST TANK IS EQUIPPED WITH A SPECIAL PLACEMENT DEVICE, WHICH IS CONVENIENT FOR CUSTOMERS TO OPERATE;
9. THE TEST TANK IS PROCESSED WITH SPECIAL 316 STAINLESS STEEL, AND THE TOP IS EQUIPPED WITH A SPECIAL COVER FOR HIGH TRANSPARENT PROTECTION;
10. THE WASHER BELOW THE SAMPLE IS MADE OF HIGH-QUALITY PTFE MATERIAL AFTER SPECIAL PROCESSING;
11. SQUARE METAL BLOCK NET: OPEN SPACE ≥50°%; BENDING ≤5mm AT 30KPA;
12. INSTRUMENT TIME CONTROL ACCURACY ≤01 SECONDS;
13. THE SHELL OF THE INSTRUMENT IS MADE OF HIGH-QUALITY METAL BAKING PAINT, WHICH IS BEAUTIFUL AND GENEROUS.
14. EQUIPPED WITH PRINTER INTERFACE, CONNECTED TO THE PRINTER CAN DIRECTLY PRINT DATA REPORTS.
TECHNICAL PARAMETERS:
1. SAMPLE SIZE: 75mm X 75mm
2. TEST AREA: 28.26 SQUARE CENTIMETERS
3. AIR PRESSURE ADJUSTMENT RANGE (0.5 ~ 30) KPA
4. EXTERNAL SIZE: 500mm X 500mm X 500mm (L X W X H)
5. WEIGHT OF THE INSTRUMENT: 40 KG
6. POWER SUPPLY: AC220V, 50HZ,SCOPE OF SUPPLY: 1. ONE MAIN MACHINE; 2. TWO PTFE GASKETS; 3. TWO ORDINARY WASHERS; 4. ONE METAL BLOCKING NET; 5. A SET OF SPECIAL LOCKING TOOLS; 6. ONE HIGH-QUALITY SILENT AIR PUMP, [NOTE: SAFETY PRODUCTION LICENSE IS NOT INCLUDED]. 7. EQUIPPED WITH PRINTER INTERFACE; 8. ONE SAMPLE TEMPLATE; 9. ONE PRODUCT CERTIFICATE; 10. ONE COPY OF PRODUCT OPERATION MANUAL.
OPERATION INSTRUCTION:
INSERT THE AIR PUMP OUTPUT PIPE INTO THE OIL AND WATER SEPARATOR OF THE INSTRUMENT AS REQUIRED (PRESSURE 0.1-0.3MPA).
AFTER SWITCHING ON THE POWER, THE STARTUP INTERFACE (NAME OF THE DEVICE) IS DISPLAYED.
PRESS THE "ENTER" BUTTON TO ENTER THE TEST INTERFACE, AS SHOWN IN THE FOLLOWING FIGURE:
CLICK "SETTING” BUTTON, GET INTO PARAMETER SETTING SCREEN, AS BELOW THIS SCREEN CAN SET THE SYSTEM TIME, DATE AND TESTING TIME, AFTER SETTING, CLICK "SAVE” BUTTON TO KEEP THE SETTING DATA. (NOTE: IT REQUIRES 5 MINUTES IN THE STANDARD)
QUANTITY: 1
Learn More - T-6575 NON-INVASIVE VENTILATOR
NON-INVASIVE VENTILATOR
Learn More
CERTIFICATE: CE
MEDICAL VENTILATOR
TECHNICAL PARAMETERS OF DOUBLE LEVEL VENTILATOR
VENTILATOR TYPE: ELECTRIC CONTROL
SCOPE OF APPLICATION: TREATMENT AND TITRATION OF SLEEP APNEA HYPOPNEA SYNDROME, SEVERE SNORING, AND RESPIRATORY INSUFFICIENCY.
DISPLAY INTERFACE: 3.5-INCH LED SCREEN, CHINESE OPERATING SYSTEM
*VENTILATION MODE: CPAP, S, S/T, T
PRESSURE RANGE:
PRESSURE RANGE: 4-30CMH2O (±0.5CMH2O)
PRESSURE ACCURACY: + 0.5CMH2O
PARAMETER SETTING:
DELAYED BOOST: 0-60MIN, SET THE DIVISION INTERVAL 5MIN
INITIAL PRESSURE: 4CMH2O TREATMENT PRESSURE / RESPIRATORY PRESSURE SETTING
THERAPEUTIC PRESSURE: 4-20CMH2O (IN CPAP MODE)
TARGET TIDAL VOLUME: 150ML - 1500ML, ON/ OFF
MAXIMUM SUCTION PRESSURE: 4-30CMH2O, (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
MINIMUM SUCTION PRESSURE: 4-30CMH2O (NOT HIGHER THAN THE SUCTION PRESSURE), (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
INSPIRATORY PHASE PRESSURE: 4-30CMH2O
EXPIRATORY PRESSURE: 4-30CMH2O
EXPIRATORY DECOMPRESSION: PATIENT, OFF, 1-3, THREE ADJUSTABLE
MANUAL VOLTAGE REGULATION: 0-2 GEAR, 0-2CMH2O (ONLY AVAILABLE IN CPAP MODE)
INSPIRATORY SENSITIVITY: 1-8 STALLS
EXPIRATORY SENSITIVITY: 1-8 STALLS
RESPIRATORY FREQUENCY: 3-40 TIMES / MIN
INSPIRATORY TIME: 0.3-3.0S
BACKUP RATE: ON / OFF, DEFAULT 10
PRESSURE RISE TIME: 1-4 STALLS
HUMIDIFIER: 1-5 ADJUSTABLE IN 5 GEARS
*TITRATION FUNCTION: SUPPORT MANUAL AND AUTOMATIC PRESSURE TITRATION, BUILT-IN REMOTE WIRELESS COMMUNICATION MODULE, COMPLETE THE RANDOM SWITCHING OF SINGLE AND DOUBLE LEVEL MODES IN THE TITRATION PROCESS, AND CONTROL MORE THAN 11 VENTILATOR PARAMETERS AT THE SAME TIME.
AUXILIARY FUNCTION: AUTOMATIC AIR LEAKAGE COMPENSATION, AUTOMATIC STARTUP, AUTOMATIC SHUTDOWN, DELAYED SHUTDOWN, SCREEN BACKLIGHT ADJUSTMENT
MONITORING PARAMETERS: PRESSURE, TIDAL VOLUME, RESPIRATORY RATE, MINUTE VENTILATION VOLUME, AIR LEAKAGE VOLUME, INSPIRATORY TIME, BLOOD OXYGEN SATURATION
WAVY CURVE: PRESSURE TIME WAVEFORM, FLOW RATE TIME WAVEFORM
ALARM PROMPT: PIPELINE AND MASK FALLING OFF, AIR LEAKAGE PROMPT, POWER INTERRUPTION, TREATMENT MACHINE FAILURE, HUMIDIFIER FAILURE, LOW VOLTAGE, HIGH RESPIRATORY RATE, LOW RESPIRATORY RATE, LOW MINUTE VENTILATION VOLUME, LOW BLOOD OXYGEN, REPLACEMENT OF FILTER COTTON, FULL SD CARD, RE INSERTION OF SD CARD
*DATA MANAGEMENT:
NETWORK DATA: BMC + RESPIRATORY HEALTH MANAGEMENT CLOUD PLATFORM
SD CARD DATA: RESART NPAP DATA ANALYSIS SOFTWARE
PARTS:
SD CARD: STANDARD
SD CARD SLOT: STANDARD
PIPING: 9 22MM, 1.8M LONG
FACE SHIELD: F2 NOSE MASK AS STANDARD
NOISE: LESS THAN 30DB
ENVIRONMENT CONDITION:
TEMPERATURE:
(WHEN USED) 5 -35 C
(DURING TRANSPORTATION AND STORAGE) -20 C -55 C
ATMOSPHERIC PRESSURE:
(WHEN USED) 760-1060HPA
(DURING TRANSPORTATION AND STORAGE) 760-1060HPA
WORKING HOURS: MORE THAN 8 HOURS
POWER SUPPLY REQUIREMENTS:
AC VOLTAGE: 100-240V
FREQUENCY: 50HZ/60HZ
INPUT POWER: LESS THAN 2A
WATERPROOF LEVEL: IP22 - DRIP PROOF EQUIPMENT
INSTRUMENT SIZE: 290mm X 180mm X 134mm
WEIGHT: 1.5KG (EXCLUDING HUMIDIFIER) 2.5KG (INCLUDING HUMIDIFIER)
ITEM 001
QUANTITY: 10 SETS-999 SETS
ITEM 002
QUANTITY: 1,000 SETS-9,999SETS
ITEM 003
QUANTITY: ≥10,000 SETS - J-2640 DYEING AND FINISHING PLANT FOR SALE
REFERENCE NUMBER: J-2640
DYEING AND FINISHING PLANT FOR SALEITEM 001
THIES SAMPLE DYEING MACHINE
MODEL: MINISOFT SAMPLE
CAPACITY: 50 KGS
YEAR: 1999
MICROPROCESSOR CONTROLLED
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING REEL AND FABRIC EXIT PLAITOR
QUANTITY: 1ITEM 002
THIES DYEING MACHINE
MODEL ECOSOFT PLUS
3 PORT SPLIT/SPLIT
CAPACITY: 900 KGS
YEAR: 1999
MICROPROCESSOR CONTROLLED
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING REEL AND FABRIC EXIT PLAITOR
QUANTITY: 1ITEM 003
THIES DYEING MACHINE
MODEL: ECOSOFT PLUS
2 PORT SPLIT/SPLIT
CAPACITY: 600 KGS
YEAR: 1999
MICROPROCESSOR CONTROL
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING REEL AND FABRIC EXIT PLAITOR
QUANTITY: 1ITEM 004
THIES DYEING MACHINE
MODEL ECOSOFT PLUS
1 PORT SPLIT/SPLIT
CAPACITY: 300 KGS
YEAR: 1999
MICROPROCESSOR CONTROLLED
VOLTAGE: A460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING REEL AND FABRIC EXIT PLAITOR
QUANTITY: 1ITEM 005
GASTON COUNTY DYEING MACHINE
MODEL: AQUAFLOW
2 PORT
CAPACITY; 250 KGS
YEAR: 1987
MICROPROCESSOR CONTROLLED
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING AND UNLOADING REEL
QUANTITY: 1ITEM 006
THIES DYEING MACHINE
MODEL: SOFT TRD
2 TUBE
CAPACITY: 700 KGS
YEAR: 1999
MICROPROCESSOR CONTROLLED
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING REEL AND FABRIC EXIT PLAITOR
QUANTITY: 1ITEM 007 (also our J-2647)
LAFER OPEN WIDTH COMPACTOR MACHINE
MODEL: KSA 500 2400/2200
YEAR: 1998
LAFER TEXEN CONTROLS
VOLTAGE: 480 VOLTS, 3-PHASE, 60 Hz
COMPOSED OF:
• TENSION BAR ENTRY TO LATTICE ROLL GUIDER
• OPERATOR’S PLATFORM
• PUP TENTER WITH KNIT ENTRY, VERTICAL PIN CHAIN, WITH PLATE GUIDES, RAIL OPENING, PINNING BRUSHES, PINS ONLY, WITH SUPPORT SECTION FOR THE FABRIC IN THE CENTER, AT 10’ THERE IS A STEAMING SECTION, TOTAL LENGTH OF THE TENTER IS 30’, WITH AUTOMATIC LUBRICATION FOR THE CHAIN
• KSA 500 COMPACTOR BENCH WITH TEXEN CONTROLS
• TENSIONLESS FABRIC CONVEYOR
• PLAITOR AND FABRIC SCRAY WITH OPTICAL LOAD SENSOR
• INLINE INSPECTION BATCHER MACHINE, WITHH A BACK LIGHTED BOARD, MANUAL CUT
• SCALE TO WEIGHT THE FABRIC
QUANTITY: 1ITEM 008 (also our J-2648)
SANTEX TUBULAR 4-ROLL EXTRACTION PAD
MODEL: SANTASTRETCH PLUS 140
YEAR: 1998
COMPOSED OF TURNTABLE, DETWISTER, TUBULAR 4-ROLL PAD WITH WET SPREADERS, PLAITOR
WITH ADDITION TANKS FOR SOFTENER
REEL FABRIC PLAITOR EXIT
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
QUANTITY: 1ITEM 009
SANTEX CONVEYOR DRYER FOR OPEN WIDTH AND TUBULAR FABRIC
MODEL: SANTASHRINK 4/5240
YEAR: 1998
SANTEX CONTROLS
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
COMPOSED OF:
• TENSION BAR ENTRY TO LATTICE ROLL GUIDER TO
• (2) SANTEX 2-ROLL PADS, RUBBER OVER RUBBER, 102” WIDE x 12” DIAMETER, STAINLESS STEEL PAN, 10-TON PAD, SWING-AWAY PAN, TENSION BAR WITH 2 STAINLESS STEEL MIXING TANKS, 75 GALLONS EACH
• DRIVEN SCROLL ROLLS WITH EDGE GUIDE CONTROL, WIDTH 95”
• OPERATOR’S PLATFORM
• PUP TENTER WITH KNIT ENTRY 45°, YEAR 1998, VERTICAL PIN CHAIN, 30’ LONG WITH TANDEMATIC PLATE GUIDES, RAIL GUIDES, PINNING BRUSHES, GUIDE SUPPORT FOR THE FABRIC, FABRIC CONVEYOR TO ENTER BOTH TUBULAR OR OPEN WIDTH FABRIC TO
• CONVEYOR DRYER 100” WIDE, 5 ZONES, 3-PASS WITH MAXON BURNERS, 5 CIRCULATING FANS TO CONVEYOR BELT TO PLAITOR
• ALL MOTORS AND SANTEX CONTROLS AND MONITORS
QUANTITY: 1ITEM 010
SANTEX AG TUBULAR COMPACTOR MACHINE
MODEL: SANTASPREAD 140
YEAR: 1998
SANTEX CONTROLS
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
COMPOSED OF:
• TENSIONS BAR ENTRY
• OPERATOR’S PLATFORM
• TENSION DEVICE
• DRIVEN SPREADER BARS
• STEAMING DEVICE
• TUBULAR COMPACTING BENCH
• FELT BLANKET ONTO THE CONVEYOR BELT
• PRECISION PLAITOR
• TABELTOP ELECTRONIC SCALE
QUANTITY: 1ITEM 011
COMET NAPPER
MODEL: PEGSO-X4
YEAR: 1998
VOLTAGE: 480 VOLTS, 3-PHASE, 60 Hz
24 ROLLS WITH TURNING BARS FOR TUBULAR 90” WIDE
XYCOM CONTROLS
12-BAG COLLECTION SYSTEM AND PLAITOR
YEAR: 1996
QUANTITY: 1ITEM 012
STENTEX TENTER FRAME
MODEL: STENTOTHERM 3300
YEAR: 1999
STENTEX CONTROLS
VOLTAGE: 480 VOLTS, 3-PHASE, 60 Hz
COMPOSED OF:
• TENSION ENTRY TO TEXT-STAR TYPE GUIDER TO 2 ROLL PAD
• ADDITION TANK TOP SCRAY PAD TO TEXT-STAR TYPE GUIDER
• TWO ROLL PAD R/R 10 TON
• OPERATOR’S PLATFORM
• WORKING WIDTH 1800mm
• HORIZONTAL PIN CHAIN, KNIT ENTRY
• TANDEMATIC SPLITLEVEL DECURLERS
• OVERFEED
• PINNING BRUSHES
• STEAM BOX
• RAIL GUIDERS, 20 FEET ENTRY, 8 ZONES
• 80 FEET HOUSING
• SCREEN MONITORS
• GAS FIRED, MAXON OVEPAK 408 BURNERS
• HONEYWELL CONTROLS
• 3 FEET COOLING ZONE
• 2 COOLING CANS, SELVEDGE TRIMMERS
• PLIATOR, SCRAY
• ZONE IN LINE INSPECTION BATCHER
QUANTITY: 1ITEM 013
ZIMMER ROTARY SCREEN PRINTING MACHINE
MODEL: R92-S153
YEAR: 1993
COMPOSED OF:
• TENSION BAR SKY ENTRY
• SCRAY
• CORINO BRUSH
• CORINO PRINT GUIDER
• ZIMMER PRINTER, 8 COLOR, 86” BLANEKT
• PRINT CONVEYOR DRYER, 30’ LONG, 3-ZONE, GAS FIRED
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
QUANTITY: 1ITEM 014
Learn More
SAFETY SWITCH BULLET NOSE SLITTER
MODEL: CUTTING
WITH REEL FABRIC PLIATOR
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
QUANTITY: 1