Search results for: 'Technical'
- Related search terms
- Technical da
- Technical date
- technical sales position
-
DORNIER PTS4/S RAPIER LOOM SETUP TO WEAVE, WIDTH 1900mm, YEAR 2016REFERENCE NUMBER: T-6980 DORNIER PTS4/S RAPIER LOOM SETUP TO WEAVE, WIDTH 1900mm, YEAR 2016 DORNIER PTS4/S RAPIER LOOM SETUP TO WEAVE WIDTH 1900mm FLAT CARBON FIBER YARN YEAR 2016 (INCORPORATING ISUMI WEFT FEEDER AND TEXKIMP COMPOSITE 960 END CREEL) BRIEF TECHNICAL INFORMATION: MAKE AND TYPE: DORNIER PTS 4/S WEFT INSERTION: RAPIER RAPIER: FIXED / POSITIVE WEFT COLORS: 4 (ONLY 1 BEING USED) ECS SELECTORS: 4 WEFT FEED: ISUMI NO TWIST SINGLE FLAT YARN FEEDER MODEL WF-510 WARP FEED: 960 END TEXKIMP COMPOSITE CREEL TYPE CF-F SELVEDGE TYPE: CATCH SELVEDGE CUTTER LHS AND RHS PREINSTALLED SELVEDGE WASTE BIN: 1 DOBBY MODEL & TYPE: STAUBLI S3020 E3 INSTALLED LEVERS: 12 INSTALLED UNDERMOTIONS: 12 FRAMES SUPPLIED: 12 LOOM TAKE-UP: ELECTRICAL LOOM LET-OFF: ELECTRICAL CLOTH ROLLERS: 2 X AIR BARS FOR WINDING ONTO CARDBOARD TUBE HEALD WIRES: AS ON LOOMS CONTROL PANEL: 15 INCHES TOUCHSCREEN PANEL ERGOWEAVE SPARE PARTS & MANUALS: ALL RELATED SPARE PARTS AVAILABLE IN THE FACTORY ELECTRICAL SUPPLY: 3 PHASE 380-415V, 50Hz QUANTITY: 1 Learn More -
P-8704 PROTECTIVE SUITREFERENCE NUMBER: P-8704
PROTECTIVE SUIT
MEETS THE TECHNICAL REQUIREMENTS FOR CE AND FDA
HIGH GRAM WEIGHT NONWOVENS OF 68G/M²
ENHANCED WATER RESISTANCE, SYNTHETIC BLOOD PENETRATION RESISTANCE
PREVENT PARTICLES EFFECTIVELY
TYPE 5 AND TYPE 6 PROTECTION
SPE COATING: MOISTURE PROOF, BREATHABLE, FLEXIBLE, NON COMBUSTIBLEHIGH STRENGTH AND TENSILITY
DURABLE AND TEAR RESISTANCE
ANTISTATIC TREATMENT
REDUCE THE ABSORPTION OF HARMFUL SUBSTANCE
SELASTICATED WRISTS, ANKLES AND FACES, HOODED COVERALL
SELF ADHESIVE ZIPPER
CARTON SIZE: 49X45X44mm
GW: 8.50KG
IN A CARTON: 25PCS
QUANTITY: 1
Learn More -
T-6552 MASK AIR TIGHTNESS TESTERREFERENCE NUMBER: T-6552
MASK AIR TIGHTNESS TESTER
MASK AIR TIGHTNESS TESTER
HOW TO CHOOSE A HIGH-QUALITY MASK NOT ONLY DEPENDS ON THE FILTERING EFFICIENCY OF THEMASK, BUT ALSO TO CONFIRM WHETHER THE MASK IS COMPLETELY IN CONTACT WITH THE FACE, OTHERWISE AEROSOL PARTICLES SUCH AS GERMS THAT HAVE NOT BEEN FILTERED BY THE MASK WILL BE INHALED FROM THE INADEQUATE ADHESION. THEREFORE, IT IS VERY IMPORTANT TO CHECK THE WEARING STATUS OF THE MASK. THE EUROPEAN AND AMERICAN COUNTRIES HAVE LISTED THE APPLICATION TEST OF THE MASK AS A STRONG INSPECTION ITEM.
FOR EXAMPLE, THE N95 MASK IS ONE OF 9 TYPES OF PARTICULATE PROTECTIVE MASKS CERTIFIED BY NIOSH (NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH). "N" INDICATES OIL RESISTANCE."95" INDICATES THAT THE PARTICLE CONCENTRATION IN THE MASK IS MORE THAN 95% LOWER THAN THAT OF THE PARTICLES OUTSIDE THE MASK WHEN EXPOSED TO THE SPECIFIED NUMBER OF SPECIAL TEST PARTICLES. N95 IS NOT A SPECIFIC PRODUCT NAME, AS LONG AS IT MEETS THE N95 STANDARD AND PASSES THE NIOSH REVIEW, IT CAN BE CALLED "N95 MASK".
N95 TYPE MASKS, IN ADDITION TO THE FILTERING EFFICIENCY OF THE MASKS, THE CLOSENESS OF THE MASKS TO THE FACE IS ONE OF THE IMPORTANT FACTORS THAT DETERMINE THE EFFECTIVENESS OF THE USE OF THE MASKS. THE SUITABILITY OF DIFFERENT TYPES OF MASKS FOR THE HUMAN FACE VARIES GREATLY.
THEREFORE, BEFORE USING A MASK, THE SUITABILITY OF THE MASK SHOULD BE CHECKED FIRST. DURING THETIGHTNESS TEST OF THE WEARER'S FACE, ENSURE THAT AIR CAN PASS IN AND OUT THROUGH THE MASK WHEN IT IS CLOSE TO THE EDGE OF THE FACE. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTION PERFORMANCE. IT CONFORMS TO THE CHINESE RESPIRATOR STANDARD GB2626-2019 STANDARD, OSHA / CSA STANDARD AND CHINA GENERAL ADMINISTRATION OF QUALITY SUPERVISION, INSPECTION AND QUARANTINE "GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS" JOINTLY ISSUED BY THE CHINA NATIONAL STANDARDIZATION ADMINISTRATION COMMITTEE.
ADHESION (SUITABILITY TEST): THE MASK DESIGN SHOULD PROVIDE GOOD ADHESION. THE OVERALL FIT FACTOR OF THE MASK SHOULD NOT BE LESS THAN 100. THIS TEST THE REQUIREMENTS WERE FORMALLY IMPLEMENTED ON AUGUST 1, 2011.
Learn MoreMASK TIGHTNESS TESTER USES CNC TECHNOLOGY, SUITABLE FOR 100 / 99 / P3 / HEPASERIES MASKS DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING DISPOSABLE DUST MASKS SUCH ASN95 / N90 / KN95), GAS MASKS / BREATHING MASKS, ADHESIVENESS TEST OF HALF-MASK AND FULL FACE MASK, INDEPENDENT OR COMPUTER CONTROL, FIVE LANGUAGES SWITCH DISPLAY, EQUIPPED WITH MULTIPLE COMMUNICATION INTERFACES (USB, ETHERNET), WIFI CAN ALSO BE ENABLED, ONE COMPUTERCAN CONTROL FOUR INSTRUMENTS AT THE SAME TIME.PARAMETER:CONCENTRATION RANGE: 0 ~ 100,000 / CM3GRAIN DIAMETER: 0.02 ~ 1.0^MFLOW: SAMPLING FLOW: 100CM3 / MINTOTAL FLOW: 700CM3 / MINCLOSENESS COEFFICIENT TEST: DIRECT TEST (COUT/ CIN)LIQUOR: 99.5% + ISOPROPANOL (ANALYTICAL GRADE)DISPLAY: 7INCH TRUE COLOR TOUCH SCREENCOMMUNICATION INTERFACE: USB X 3 (HOST X 2,DEVICE X 1) ETHERNET INTERFACE X1CONNECTION PORT: ENVIRONMENT PORT, SAMPLING PORTWIFI: EQUIPPEDLANGUAGES: ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESEFLOW CONTROL: SENSOR CONTROLPC CONTROLLABLE OPERATION: ONE COMPUTER CAN CONTROL 4 INSTRUMENTS AT THE SAME TIMEDATA OUTPUT FORMAT: MICROSOFT EXCELWORKING TEMPERATURE: 15 ~ 35 °CPOWER SOURCE: AC 110 —240V 50 / 60HZAPPEARANCE SIZE: 208 X 117 X 262MMWEIGHT: 2.1KGACCESSORIES: ALCOHOL REAGENT BOTTLE, PROTECTIVE CAP, REAGENT STICK, ZERO-COUNT FILTER, STRAINER, SAMPLING TUBE, INSTRUCTION MANUAL, AC ADAPTER, TOUCH SCREEN PEN, OPTIONAL COMPUTER.OPTIONAL: TEST KIT FOR TIGHTNESS COEFFICIENTIN ORDER TO PREVENT INFECTION AT THE MEDICAL SITE AND DURING LABOR WORK, WORKERS MUST BE PROTECTED FROM INHALABLE HAZARDOUS SUBSTANCES IN THE WORKPLACE, AND RESPIRATORS SUCH AS MASKS MUST BE WORN DURING WORK.SELECT A RESPIRATOR, SUCH AS A MASK, BASED ON YOUR FACIAL FEATURES, AND EVALUATE THE TIGHTNESS BETWEEN THE RESPIRATOR, SUCH AS A MASK AND THE FACE, TO CHECK WHETHER THERE ARE GAPS OR LEAKS THAT PUT WORKERS AT RISK. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTIVE PERFORMANCE. SECURITY EXPERTS WILL ALSO DEVELOP PROTECTION SCHEMES AND STANDARD REGULATIONS BASED ON THE RESULTS OF THE TIGHTNESS TEST. WIDELY USED IN HOSPITALS, MANUFACTURING PLANTS, PRODUCTION SITES, FIREFIGHTING WORKPLACES AND OTHER OFFICIAL TESTING AGENCIES.MASK TIGHTNESS TESTER FEATURES:• QUANTITATIVE TIGHTNESS TEST FOR RESPIRATORS SUCH AS MASKS (QNFT)• APPLICABLE TO 100/99 / P3 / HEPA SERIES MASK DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING N95 / N90 / KN95 AND OTHER DISPOSABLE DUST MASKS)• ADHESION TEST OF HALF MASK AND FULL FACE MASK• GAS MASK TIGHTNESS TEST• PAPR MASK TIGHTNESS TEST• SCBA RESPIRATOR MASK TIGHTNESS TEST• 7INCH TRUE COLOR TOUCH SCREEN• INDEPENDENT OR COMPUTER CONTROLLED• USING CNC TECHNOLOGY• ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESE LANGUAGE SWITCHING DISPLAY• COMPLIES WITH US OSHA STANDARDS, CANADIAN STANDARDS ASSOCIATION (CSA) GUIDELINES, INCLUDING N95• EQUIPPED WITH A VARIETY OF COMMUNICATION INTERFACES (USB, ETHERNET), AND CAN ALSO ENABLE WIFI• ONE COMPUTER CAN CONTROL FOUR INSTRUMENTS AT THE SAME TIMEQUANTITY: 1 -
V-1817 SEMI-AUTOMATIC NOSE CLIP WELDING MACHINESEMI-AUTOMATIC NOSE CLIP WELDING MACHINE FOR NOSE CLIP WELDING FOR DUST MASK RESPIRATORS, IT’S EASY TO OPERATE, FIRM WELDING EFFECT. THIS MACHINE INCORPORATES CONSTANT TEMPERATURE WELDING, WHICH IS NOT HARMFUL TO THE FABRIC, IT’S THE IDEAL MACHINE FOR DUST MASK RESPIRATOR MANUFACTURING.
FEATURES:
1. THIS MACHINE IS EASY TO OPERATE; THE GLUED ALUMINUM NOSE CLIP IS MOVED BY PNEUMATIC THEN WELDED ONTO THE MASK.
2. IT’S HIGH PRECISION AND THE NOSE CLIP WELD IS FIRM.
3. WELDING WITH CONSTANT TEMPERATURE WHICH IS NOT HARMFUL TO THE FABRIC.
ITEM NAME
TECHNICAL PARAMTER
QTY
REMARK
SPECIFICATION
1200mm X 650mm X 1000mm
1
HONGDA
WEIGHT
50KG
EFFICIENCY
8 TO 15PCS/MIN
VOLTAGE
220V/380V
AIR PRESSURE
5KG/CM²
FREQUENCY
20KHZ
POWER
600W
MOLD SERVO MOTOR
SGM7G-09AFC61 4.4KW
1
YASKAWA
ULTRASONIC POWER SERVO MOTOR
SGM7G-13AFC61 1.3KW
2
YASKAWA
MATERIAL PULLING SERVO MOTOR
SGM7G-09AFC61 0.85KW
2
YASKAWA
MATERIAL FEEDING/CORRECTING/INDENTATION MOTOR
130BYG-350A
4
SONGYANG
POUCHING MOTOR
110BYG-350B
4
SONGYANG
110 STEPPER MOTOR
110BYG-350A
10
SONGYANG
UP AND LOWER MOTOR
90BYG-350A
2
SONGYANG
STEPPER MOTOR 56
SY57STH56-2004A
8
SONGYANG
DIRECT CURRENT MOTOR
0.4KW
2
DIRECT CURRENT MOTOR
0.6KW
1
ASYNCHRONOUS THREE-PHASE MOTOR
90S-6
1
0.75KW
FREQUENCY CONVERTER
AVF200-0152
1
1.5KW
MAIN PNEUMATIC COMPONENTS: AIRTAC(TAIWAN); MAIN ELECTRICAL COMPONENTS: PANASONIC(JAPAN), SICK(GERMANY), DONLIM(CHINA&JAPAN), ETC.
EMAIL US FOR PRICE & PICTURES
INCLUDE OUR REFERENCE NUMBER
Learn More -
V-1816 AUTOMATIC RESPIRATOR REPLACEMENT FILTER MAKING MACHINEAUTOMATIC RESPIRATOR REPLACEMENT FILTER MAKING MACHINE IS ALSO CALLED A PARTICULATE RESPIRATOR FILTER MAKING MACHINE OR HALF FACE RESPIRATOR FILTER MAKING MACHINE, IT’S MADE UNDER MATURE TECHNOLOGY THAT SUPPORTS AUTOMATICALLY MATERIAL FEEDING, WELDING, PUNCHING AND CUTTING, REPLACEMENT FILTER FORMING, THIS MACHINE IS EASY TO OPERATE, BY CHANGING THE ROLLER, IT CAN PRODUCE DIFFERENT SHAPES OF FILTER. THIS MACHINE INCORPORATES ADVANCED ULTRASONIC WELDING AND EQUIPPED WITH CONSTANT TEMPERATURE CONTROLLER WHICH ENSURES THE FILTER FIRMLY AND CLEARLY WELDED.
FEATURES:
1. ADVANCED ULTRASONIC TECHNOLOGY WITH FIRM WELDING EFFECT, IT’S EQUIPPED WITH PULL AND PUSH TYPE MATERIAL FEEDING WHICH MAKES IT EASIER OPERATING.
2. THE MOLD (PATTERN ROLLER) CAN BE CUSTOMIZED TO PRODUCE DIFFERENT FILTERS.
3. THE WELDING LINE IS CLEAR AND FIRM.
ITEM NAME
TECHNICAL PARAMETERS
QTY
REMARK
SPECIFICATION
1800mm X 1200mm X 1800mm
1
HONGDA
WEIGHT
500KG
EFFICIENCY
20 TO 30PCS/MIN
VOLTAGE
220V/380V
AIR PRESSURE
3-6KG/CM²
FREQUENCY
15/20KHZ
POWER
4200W
MOLD SERVO MOTOR
SGM7G-09AFC61 4.4KW
1
YASKAWA
ULTRASONIC POWER SERVO MOTOR
SGM7G-13AFC61 1.3KW
2
YASKAWA
MATERIAL PULLING SERVO MOTOR
SGM7G-09AFC61 0.85KW
2
YASKAWA
MATERIAL FEEDING/CORRECTING/INDENTATION MOTOR
130BYG-350A
4
SONGYANG
POUCHING MOTOR
110BYG-350B
4
SONGYANG
110 STEPPER MOTOR
110BYG-350A
10
SONGYANG
UP AND LOWER MOTOR
90BYG-350A
2
SONGYANG
STEPPER MOTOR 56
SY57STH56-2004A
8
SONGYANG
DIRECT CURRENT MOTOR
0.4KW
2
DIRECT CURRENT MOTOR
0.6KW
1
ASYNCHRONOUS THREE-PHASE MOTOR
90S-6
1
0.75KW
FREQUENCY CONVERTER
AVF200-0152
1
1.5KW
MAIN PNEUMATIC COMPONENTS: AIRTAC (TAIWAN); MAIN ELECTRICAL COMPONENTS: PANASONIC (JAPAN), SICK (GERMANY), DONLIM (CHINA&JAPAN), ETC.
EMAIL US FOR PRICE & PICTURES
INCLUDE OUR REFERENCE NUMBER
Learn More -
R-7393 BALL FIBER LINE, YEAR 1970 TO 1980R-7393 BALL FIBER LINE, YEAR 1970 TO 1980
BRAND BALL FIBER LINE
Learn More
YEAR 1970 TO 1980
STATUS AVAILABLE
LINE FOR MANUFACTURING SILICONE BALL OF POLYESTER FIBER:
1 CARD DUISENBERG 2.5 PHASES 2500mm, 1980 MODEL
1 SPINNBAU CARD
1.5 PHASES 1800mm, 1970 MODEL
1 BALL MACHINE 80 KG / HR
1 BALL FIBER MACHINE 50 KG / H
THE LINE IS IN EXCELLENT TECHNICAL CONDITION -
R-7391 BEMATIC BOMBI NONWOVEN CARDLINE AND OVEN, 2500mm, YEAR 2005R-7391 BEMATIC BOMBI NONWOVEN CARDLINE AND OVEN, 2500mm, YEAR 2005
BRAND BEMATIC
Learn More
MODEL BOMBI
YEAR 2005
STATUS AVAILABLE
BEMATIC - BOMBI NONWOVEN
2 BALE HOLES, 1 OPENING ROLL, 1 OPENER
1 CARD HERGETH 2500mm, 1.5 PHASES
1 CROSS TAPPER 2500mm
1 BOMBI OVEN, 3 LAYERS, 10 M LONG, 2600mm WIDTH
3 WEISHAUPT BURNERS
1CUTTING MACHINE, 4 HORIZONTAL KNIVES
1 ROLLING MACHINE
1 SCALE
1 PACKING MACHINE THE LINE IS IN EXCELLENT TECHNICAL CONDITION -
L-4855 MASCOE COATING MACHINE, MODEL 5KC, YEAR 2006 (2000mm)REFERENCE NUMBER: L-4855
MASCOE COATING MACHINE, MODEL 5KC, YEAR 2006 (2000mm)
MAKE: MASCOE
YEAR: 2006
MODEL: 5KC
QUANTITY: 1
Learn More -
K-8416 G1 TONELLO 330 "CENTRIFUGING" INDUSTRIAL WASHING MACHINE-USEDREFERENCE NUMBER: K-8416
G1 TONELLO 330 "CENTRIFUGING" INDUSTRIAL WASHING MACHINE-USED
G1 TONELLO 330
“CENTRIFUGING” INDUSTRIAL WASHING MACHINE
FRONTAL TYPE
FOR CHEMICAL “STONE WASH”
CAPACITY LIT. 3.300
MOD. TONELLO G1 330
GENERAL DESCRIPTION:
TONELLO G1 IS A MACHINE WITH HIGH-SPEED HYDRO-EXTRACTION (600 R.P.M.) AND IT IS EQUIPPED WITH AUTOMATIC SELF-BALANCING SYSTEM
TONELLO G1 IS SUPPLIED WITH “SETTABLE INVERTER”
ROTATION SPEED FROM 0 TO 55 R.P.M
ALSO SETTING THE CENTRIFUGING SPEED FROM 0 TO 600 R.P.M.
WITH TIME OF CENTRIFUGE PROGRAMMABLE BY INDUSTRIAL PC
THE ACCESS MAIN DOOR TO THE DRUM IS VERY WIDE, IN ORDER TO EASY GARMENTS LOADING AND UNLOADING OPERATION
OPENING AND CLOSING ARE PNEUMATIC
DOUBLE TILTING SYSTEM FOR GARMENTS LOADING AND UNLOADING
DRIVING SYSTEM IS SITUATED ON THE UPPER PART OF THE MACHINE
WITH PROPER MATERIAL AND MOTORS SUITABLE TO WORK AT LOW AND HIGH R.P.M.
1 TANK FOR THE PREPARATION OF AUXILIARY PRODUCTS WITH CAPACITY OF LITTERS 180 EQUIPPED WITH ELECTRO-PUMP AND PNEUMATIC VALVES FOR THE SENT ONE
THE DRAINAGE IN DRAIN AND AUTOMATIC RINSES N° 2 WATER INLETS COMPLETE WITH PNEUMATIC VALVE- MECHANICAL WATER-COUNTER DIRECT HEATING AND COOLING SYSTEM
AUTOMATION WITH MICROPROCESSOR
TECHNICAL DATA TONELLO G1 330
DRUM DIMESION
-DRUM HOLING SHEET mm 4
THICKNESS
-DIAMETER MM 1900
-DEPTH MM 1150
-VOLUME LT. 3300
-DOOR DIAMETER MM 1020
-MAXIMUM LOADING KG. 120/130
CAPACITY
BASKET SPIN SPEED RPM 0-600
DIRECT STEAM CONNECTION Ø 1" 1/4
WATER INLET CONNECTION Ø 2 x 2
COMPRESSED AIR INLET Ø 1/4"
CONNECTION
STEAM IN MAXIMUM PRESSUREBAR BAR 6
WATER IN MAXIMUM PRESSURE BAR 4
COMPRESSED AIR IN MAXIMUM BAR 8
PRESSURE
POWER INSTALLED KW 22
3-PHASE VOLTAGE VOLT/HZ 400/50
PRODUCTS TANK Ø 240 H 400 LT. 80
TANK RINSING VALVE Ø 1/2"
MACHINE SIZE
-WIDTH MM 2500
-WIDTH WITH ELECTRICAL PANEL MM 2980
-DEPTH MM 2710
-HEIGHT MM 3000
Learn More -
K-5601 KUSTERS CONTINOUS BLEACHING RANGE YEAR 2004 3400MMREFERENCE NUMBER: K-5601
KUSTERS CONTINOUS BLEACHING RANGE YEAR 2004 3400MM
YOM: 2004
WIDTH: 3400mm
FACE WIDTH
WORKING WIDTH 3200mm
PRODUCTION SPEED 70 METER/MIN
TECHNICAL SPEED 100 METER/MIN
WATER PRESSURE 2.0-2.5 BAR
STEAM 2.0-2.5 BAR
REQUILTERED COMPRESSED AIR 7.0 BAR
FABRIC WEIGHT 70-250 GSM
QUANTITY: 1
Learn More