K-8666 BRUCKNER GALAXY 500 BLEACHING RANGE FOR ROPE KNITTED FABRICS-YEAR 1989REFERENCE NUMBER: K-8666
BRUCKNER GALAXY 500 BLEACHING RANGE FOR ROPE KNITTED FABRICS-YEAR 1989
MAKE: BRUCKNER
MODEL: GALAXY 500
YEAR 1989
10 CHAMBERS HEATED BY STEAM
WIDTH 1000mm TO 1100mm
ROLLER’S WIDTH 1300mm
2 DOSING STATIONS
WORKING TEMP. 98 – 180 OC
MAX. WORKING PRESSURE 6.0 BARS +/- 0,7
AVERAGE WORKING SPEED 20M/MIN
AVERAGE PRODUCTION EFFICIENCY 500 KG/H
MACHINE OVERHAULED IN 2010
QUANTITY: 1
Learn More -
M-5038 COMEZ 410 LOOMS FOR LABELS AND NARROW FABRICS YEAR 1996REFERENCE NUMBER: M-5038 (121245HQ11R) L COMEZ 410 LOOMS FOR LABELS AND NARROW FABRICS YEAR 1996 BRAND COMEZ TYPE 410 YEAR 1996 COMPLETED CREEL AND BEAMS 12 GAUGE Learn More -
R-1321 KUSTER CONTINUOUS OPEN WIDTH MERCERIZING, ROLLER SURFACE WIDTH 2000mmR-1321 KUSTER CONTINUOUS OPEN WIDTH MERCERIZING, ROLLER SURFACE WIDTH 2000mm
DETAILS:
KUSTER CONTINUOUS OPEN WIDTH MERCERIZING
FOR THE PRETRATMENT OF WOVEN FABRICS
WIDTH OF FABRIC (WB): 960 TO 1800mm
ROLLER SURFACE WIDTH: 2000mm
DRIVE SIDE: LEFT SIDE
OPERATING SIDE: FAR SIDE
PRODUCTION SPEED: 60 M/MIN
TECHNICAL SPEED: 80 M/MIN
WATER PRESSURE: 2.0 + 0.5 BAR CONSTANT TO BE PROVIDED LOCALTY
VAPOUR PRESSURE: 3.0 + 0.5 BAR WET STEAM TO BE PROVIDED LOCALTY
AS PRESSURE (FREE OF OIL AND WATER): 7 BAR, TO BE PROVIDED LOCALTY
TYPE OF FABRICS: WOVEN FABRICS
QUALITY OF FABRICS: COTTON, BLENDS, VOISE (DRY)
FABRIC WEIGHT: 65 TO 300 G/M
HIGH-EFFICIENCY PADDER TYPE 222.50 LINE FORCB: 50 N/mm (50KP/CM)
HIGH-EFFICIENCY PADDER TYPE 824.27 LINE FORCE MAX: 50 N/mm
HIGH-EFFICIENCY PADDER TYPE 824.22 LINE FORCE MAX: 50 N/mm
MAANDER TYPE 834.43 FABRICS CONTENT: 15 m
SQUEEZER TYPE 225.65 LINE FORCB: 10 N/mm
MAANDER TYPE 834.43 FABRICS CONTENT: 15 m
SQUEEZER TYPE 225.65 LINE FORCB: 10 N/mm
STILL RUNNING IN MILLSQUANTITY: 1
Learn More -
T-6548 FABRIC SURFACE WETTING TESTERREFERENCE NUMBER: T-6548
FABRIC SURFACE WETTING TESTER
INSTRUMENT TECHNICAL DESCRIPTION:
WATER TESTER IS TO INSTALL THE SAMPLE ON THE SAMPLE HOLDER AND MAKE AN ANGLE OF 45 ° WITH THE LEVEL. THE CENTER OF THE SAMPLE IS LOCATED AT A SPECIFIED DISTANCE BELOW THE NOZZLE. THE SAMPLE IS SPRAYED WITH A SPECIFIED VOLUME OF DISTILLED OR DEIONIZED WATER. BY COMPARING THE APPEARANCE OF THE SAMPLE WITH THE EVALUATION STANDARDS AND PICTURES TO DETERMINE ITS WATER-SOAKING GRADE, IT IS SUITABLE FOR MEASURING VARIOUS WATER-SOAKING TESTS ON THE SURFACE OF FABRICS WITH OR WITHOUT WATER RESISTANCE AND WATER REPELLENT FINISHING. THIS INSTRUMENT IS NOT SUITABLE FOR MEASURING THE WATER PERMEABILITY OF FABRICS, SO IT CANNOT BE USED TO PREDICT THE RAINPROOF PERMEABILITY OF FABRICS.
STANDARD:
GB19082-2009 TECHNICAL REQUIREMENTS FOR MEDICAL PRIMARY PROTECTIVE CLOTHINGGB / T4745 SURFACE MOISTURE RESISTANCE TEST
THE MAIN TECHNICAL INDICATORS OF THE INSTRUMENT:
GLASS FUNNEL: φ150mm
MEASURING CUP: 500ML
SAMPLE SUPPORT ANGLE: 45 °
INSTRUMENT CONFIGURATION:
1. ONE HOST
2. A GLASS FUNNEL
3. 500ML MEASURING CUP
QUANTITY: 1
Learn More -
T-6549 CONSTANT TEMPERATURE AND HUMIDITY CHAMBER -FABRIC WATER VAPOR TRANSMISSION RATEREFERENCE NUMBER: T-6549
CONSTANT TEMPERATURE AND HUMIDITY CHAMBER -FABRIC WATER VAPOR TRANSMISSION RATE
TESTING METER (WITH MOISTURE PERMEABLE CUP)
TECHNICAL DESCRIPTION OF THE INSTRUMENT:
IT IS MAINLY USED TO MEASURE THE MOISTURE PERMEABILITY OF ALL KINDS OF FABRICS, INCLUDING PERMEABLE COATED FABRICS. STRUCTURE PRINCIPLE: ADOPT COMPUTER CONTROL, CREATING A CONSTANT TEMPERATURE, AND HUMIDITY TEST ENVIRONMENT, TEST ENVIRONMENT IN THE CONSTANT TEMPERATURE, AND HUMIDITY, MOISTURE VAPOR TRANSMISSION CUP, PLACED 6 SAMPLE INTO THE GLASS AND THE RUBBER GASKET SEAL, THE CONTAINING HYGROSCOPIC AGENT OR WATER SEAL IS SPECIFIED BY THE WET CUP PLACED IN THE FABRIC SAMPLE TEMPERATURE AND HUMIDITY OF THE ENVIRONMENT, THE SEAL MOISTURE VAPOR TRANSMISSION CUP ACCORDING TO A CERTAIN TIME (INCLUDING SAMPLE AND HYGROSCOPIC AGENT OR WATER) TO CALCULATE THE MOISTURE TRANSMISSION QUALITY CHANGE.
TESTING STANDARD:
GB19082-2009 MEDICAL PRIMARY PROTECTIVE CLOTHING
TECHNICAL REQUIREMENTS GUIDELINES FOR THE SELECTION OF YY-T1498-2016 MEDICAL PROTECTIVE CLOTHING
GB/T12704.1 DETERMINATION OF MOISTURE PERMEABILITY OF FABRICS --HYGROSCOPIC METHOD
DETAILED TECHNICAL SPECIFICATIONS AND CONFIGURATION:
TECHNICAL INDICATORS:
1. TEMPERATURE CONTROL RANGE: -40°C ~ 150°C;RESOLUTION; 0.1 °C
2. HUMIDITY CONTROL RANGE: 50%RH ~ 95% RH±5%
3. SPEED RANGE: 2mm ~ 60mm/MIN
4. CONTROL PRECISION: TEMPERATURE <0.1°C; HUMIDITY + / -1% RH OR LESS
5. CYCLIC WIND SPEED: 0.02 ~ 0.5M/S, 0.3 ~ 0.5M/S
6. TIME CONTROL: 1 ~ 9999H
7. MOISTURE PERMEABLE AREA: 2827 mm 2 (DIAMETER IS 60 mm --NATIONAL STANDARD)
8. QUANTITY OF PERMEABLE CUPS: 6 GB;
9. DRYING BOX CONTROL TEMPERATURE: ROOM TEMPERATURE ~ 199 °C
10. TEST TIME: 1 ~ 999H
11. DRYING BOX STUDIO SIZE: 490 X 400 X 215mm
INSTRUMENT CONFIGURATION:
1. ONE MAIN MACHINE
QUANTITY: 1
Learn More -
C-1177 “THEN” LOTUS 800 KG, YEAR 2011, ROPE DYEING MACHINEREFERENCE NUMBER: C-1177 “THEN” LOTUS 800 KG, YEAR 2011, ROPE DYEING MACHINE SPECIFICATIONS: N° 1 ROPE DYEING MACHINE THEN OF 800 KG HIGH TEMPERATURE FOR THE ROPE DYEING OF WOVEN AND KNITWEAR FABRICS QUANTITY AVAILABLE: 1 Learn More -
R-1429 MONFORTS SANFORISER, WIDTH 2400mmR-1429 MONFORTS SANFORISER, WIDTH 2400mm
MONFORTS SANFORISER
MAX FABRIC WIDTH: 2400mm
THIS SANFORISER IS EXCEPTIONALLY WELL EQUIPPED
WITH A MAHLO WEFT STRAIGHTENER
AND A 10MT LONG CLIP TENTER
THE RUBBER BELT
WHICH IS IN ALMOST AS NEW CONDITION IS 2460mm WIDE
AND THE PALMER CYLINDER IS 2400mm DIAM.
MAKING IT SUITABLE FOR PROCESSING A WIDE RANGE OF FABRICS FROM LIGHTER WEIGHT APPAREL FABRICS TO DENIM
TWILLS AND BED SHEETINGS
HIGH ENTRANCE FRAME WITH ONE PAIR KF10 GUIDERS ON A SCREWED WIDTH ADJUSTMENT SHAFT
COMPENSATOR AND TENSION CONTROL RAILS
DRIVEN DRAW ROLLER
COMPENSATOR
MAHLO BOW AND SKEW WEFT STRAIGHTENER, 4 HEADS
CLIP TENTER, 10M WITH STEAMING FIELD
RUBBER BELT SHRINKING MACHINE
RUBBER BELT WIDTH 2460mm
PALMER CALENDER WITH 240CM DIAMETER CYLINDER
ENDLESS FELT BLANKET 2470mm WIDE
BLANKET DRYING CYLINDER
COOLING CYLINDER, WATER COOLED
DRAW ROLLERS
SCRAY FOR NON-STOP BATCHING
EXIT FRAME WITH DRAW ROLLER
SURFACE DRIVEN A-FRAME BATCHER AND PLAITERQUANTITY: 1
Learn More -
SANTEX ACTIWASH CONT. WASHING MACHINE, WORKING WIDTH 1800mm, YEAR 1993 OVERHAULED 2015REFERENCE NUMBER: T-6921 SANTEX ACTIWASH CONT. WASHING MACHINE, WORKING WIDTH 1800mm, YEAR 1993 OVERHAULED 2015 SANTEX ACTIWASH CONT. WASHING MACHINE YEAR 1993 OVERHAULED 2015 WORKING WIDTH 1800mm 5 WASHING BOXES EACH WITH 2 SIEVE DRUMS DWELLING CHAMBER IS 500 METER FABRIC CAPACITY AFTER EACH WASHING CHAMBERS SQUEEZER SPEED 0 TO 80 METER /MIN WITH DOSING VESSELS EXIT PLAITER MACHINE IS SUITABLE FOR WOVEN AND KNITTED FABRICS MACHINE IS OVERHAULED MACHINE IS IN EXCELLENT CONDITION QUANTITY: 1 Learn More -
T-6543 MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENTREFERENCE NUMBER: T-6543
MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
SHANDONG INDEPENDENTLY RESEARCH AND DEVELOPMENT THIS COMPREHENSIVE TESTING MACHINE FOR SURGICAL MASK & PROTECTIVE CLOTHING, IT IS WIDELY USED IN A VARIETY OF MASK STRENGTH DETECTION PROJECTS.FEATURES:COMPLY WITH NATIONAL STANDARDS, MEDICAL STANDARDS TESTING REQUIREMENTS, AUTOMATIC SOFTWARE CONTROL SYSTEM, MEET THE REQUIREMENTS OF DATA STORAGE, PRINTING, COMPARISON. THE IMPORTED SERVO MOTOR IS EQUIPPED WITH PRECISION SCREW DRIVE SYSTEM TO ENSURE THE STABILITY OF TEST DATA.
TEST STANDARDS:
GB 19082-2009 TECHNICAL REQUIREMENTS FOR DISPOSABLE PROTECTIVE CLOTHING FOR MEDICAL USE (4.5 BREAKING STRENGTH -THE BREAKING STRENGTH OF MATERIALS IN KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 45N)
(4.6 ELONGATION AT BREAK -THE ELONGATION AT BREAK OF KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 15%)
SELF-PRIMING FILTER RESPIRATOR FOR RESPIRATORY PROTECTION ARTICLES5.6.2 BREATHING BONNET -BREATHING BONNET SHALL BE SUBJECT TO AXIAL TENSION"DISPOSABLE MASK: 10N FOR 10S" "REPLACEABLE MASK: 50N FOR 10S"
(5.9 HEADBAND -HEADBAND SHOULD BEAR THE TENSION "DISPOSABLE MASK: 10N, 10S" "REPLACEABLE HALF MASK: 50N FOR 10S" "FULL MASK: 150N FOR 10S")
5.10 JOINTS AND CONNECTING PARTS -JOINTS AND CONNECTING PARTS SHALL BE SUBJECT TO AXIAL TENSION
"REPLACEABLE HALF MASK: 50N FOR 10S" "FULL COVER 250N FOR 10S"
GB/T 32610-2016 TECHNICAL SPECIFICATION FOR DAILY PROTECTIVE MASKS
(6.9 BREAKING STRENGTH OF THE MASK BELT AND THE CONNECTION BETWEEN THE MASK BELT ANDTHE MASK BODY ≥ 20N)
(6.10 FASTNESS TO BREATHING BONNET: NO SLIPPAGE, BREAKAGE OR DEFORMATION SHALL OCCUR)
YY/T 0699-2013 DISPOSABLE SURGICAL MASK
(4.4 MASK BELT -THE BREAKING FORCE AT THE CONNECTION POINT BETWEEN EACH MASK BELT AND THE MASK BODY IS NOT LESS THAN 10N)
YY 0469-2011 SURGICAL MASK FOR MEDICAL USE (5.4.2 MASK BELT)
GB/T 3923.1-1997 DETERMINATION OF BREAKING STRENGTH AND ELONGATION AT BREAK OF FABRICS (STRIP METHOD)
DISPOSABLE RUBBER INSPECTION GLOVES (6.3 TENSILE PROPERTIES)
INSTRUMENT TECHNICAL PARAMETERS:
SPECIFICATION: 200N (STANDARD) 50N, 100N, 500N, 1000N (OPTIONAL)
ACCURACY: BETTER THAN 0.5RESOLUTION OF FORCE VALUE: 0.1N
DEFORMATION RESOLUTION: 0.001mm
TEST SPEED: 0.01mm/MIN ~ 2000mm/MIN (STEPLESS SPEED REGULATION)
WIDTH OF SAMPLE: 30mm (STANDARD FIXTURE) 50mm (OPTIONAL FIXTURE)
CLAMPING OF SAMPLES: MANUAL (PNEUMATIC CLAMPING CAN BE CHANGED)
STROKE: 700mm (STANDARD) 400mm, 1000mm (OPTIONAL)
QUANTITY: 1
Learn More -
T-6577 PROTECTION SUIT WITH SHOE COVERPROTECTION SUIT WITH SHOE COVER
Learn More
HOODED DESIGN
HOODED HEAD DESIGN
ELASTIC DESIGN AT THE MOUTH
CAN ISOLATE DUST AND MICROORGANISMS
SEALED AND PROTECTED BY RUBBER STRIPS
THE WHOLE PIECE DESIGN
EASY TO PUT ON AND TAKE OFF
ELASTIC CUFFS, FLEXIBLE, EFFECTIVE BARRIER, EASIER TO USE
ELASTIC WAISTBAND SLIM ELASTIC WAISTBAND DESIGN, CLOSE THE WAIST, WORK MORE FREELY
CERTIFICATE: CE
MOQ: 1000PCS
MODEL: CONJOINED SPECS: S/160, M/165, L/170, XL/175, XXL/180 ALL SIZES ARE AVAILABLE, PRICES ARE SAME
TYPE:
NON-STERILE: 9.5KG/BOX, 30PCS/BOX, 560 X 430 X 360mm
STERILIZED FOR HOSPITAL: 13KG/BOX, 40PCS/BOX, 600 X 400 X 450mm
PRODUCT DESCRIPTION: CLOTHING MADE FROM FABRICS WITH ISOLATION FUNCTION SUCH AS VIRUS-CONTAINING AEROSOLS AND VIRUS-CONTAINING LIQUIDS. WHEN TAKEN OFF, THE OUTER SURFACE OF THE PROTECTIVE CLOTHING SHOULD NOT COME IN CONTACT WITH THE HUMAN BODY. THIS PRODUCT DOES NOT HAVE FLAME RETARDANT PROPERTIES.
INTENDED USE: OCCUPATIONAL PROTECTIVE CLOTHING FOR MEDICAL PERSONNEL IN MEDICAL INSTITUTIONS TO PREVENT THE TRANSMISSION OF VIRUSES FROM PATIENTS TO THE MEDICAL PERSONNEL WITH AIR OR LIQUID.