Search results for: 'part #'
- Related search terms
- Parts
- Part's
- Part's t
- Part's ta
- part number'
-
KUSTERS CONTINUOUS WASHING MACHINE, WORKING WIDTH 3400mm, YEAR 1996REFERENCE NUMBER: T-6916 KUSTERS CONTINUOUS WASHING MACHINE, WORKING WIDTH 3400mm, YEAR 1996 KUSTERS CONTINUOUS WASHING MACHINE FOR TUULE CURTAIN WASHING- GUIPURE TREATMENT WORKING WIDTH 3400mm ROLLER WIDTH 3600mm YEAR 1996 2 WASHING TANKS 2 KUSTERS SQUEEZING PADDER (ONE WITH S-ROLL FEATURE) 1 CHAMBER DRYING GAS HEATED WELL MAINTAINED WITH ORIGINAL SPARE PARTS SITUATION: INSTALLED AND RUNNING QUANTITY: 1 Learn More -
P-8704 PROTECTIVE SUITREFERENCE NUMBER: P-8704
PROTECTIVE SUIT
MEETS THE TECHNICAL REQUIREMENTS FOR CE AND FDA
HIGH GRAM WEIGHT NONWOVENS OF 68G/M²
ENHANCED WATER RESISTANCE, SYNTHETIC BLOOD PENETRATION RESISTANCE
PREVENT PARTICLES EFFECTIVELY
TYPE 5 AND TYPE 6 PROTECTION
SPE COATING: MOISTURE PROOF, BREATHABLE, FLEXIBLE, NON COMBUSTIBLEHIGH STRENGTH AND TENSILITY
DURABLE AND TEAR RESISTANCE
ANTISTATIC TREATMENT
REDUCE THE ABSORPTION OF HARMFUL SUBSTANCE
SELASTICATED WRISTS, ANKLES AND FACES, HOODED COVERALL
SELF ADHESIVE ZIPPER
CARTON SIZE: 49X45X44mm
GW: 8.50KG
IN A CARTON: 25PCS
QUANTITY: 1
Learn More -
T-6582 MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)REFERENCE NUMBER: T-6582
MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)
MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)
1.NP3030: MEDICAL DISPOSABLE PROTECTIVE CLOTHING,STRONG RESISTANT
2.FABRIC: SF 66 G, COLOR: WHITE RUBBER:CAP/FOOT/CUFF/WAIST FRONT FLAP: DOUBLE-SIDED TAPE, TAPE:BLUE TAPE, ETHYLENE OXIDE DISINFECTION, STERILE
3.PACKAGED: 1PC/BAG, 32PCS/CARTON,10KG/CARTONCARTON SIZE: 470 X300 X420mm/CTN
4.NOTE: CLASS II MEDICAL TREATMENT, SCOPE OF USE: MEDICALPERSONNEL CONTACT WITH POTENTIALLY INFECTIOUS PATIENTSBLOOD, BODY FLUIDS, SECRETIONS, PARTICLES IN THE AIR TOPROVIDE BARRIER, PROTECTION. THIS PRODUCT IS USED FORISOLATION OF OBSERVATION WARD (ROOM), ISOLATION WARD(ROOM), ETC. IT IS STRICTLY PROHIBITED TO USE IN THE ISOLATIONCRITICAL CARE WARD (ROOM) AND OTHER PLACES WITH STRICTCONTROL OF MICROBIAL INDICATORS1PC/BAG, 32PCS/CARTON.
WEIGHT AND DIMENSIONS OF CARTONS: 10KG/CARTON
CARTONS IN A 20 FOOT CONTAINER: 370 BOXESSTERILIZED BY ETHYLENE OXIDE GAS
EACH PIECE IS INDIVIDUALLY VACUUM PACKED
1PER PLASTIC POUCH
QUANTITY: 10,000
Learn More -
T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKSREFERENCE NUMBER: T-6547
RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
INTRODUCTION
THE RESPIRATOR RESISTANCE TESTER IS USED TO MEASURE THE INSPIRATORY RESISTANCE AND EXPIRATORY RESISTANCE OF RESPIRATORS AND RESPIRATOR PROTECTORS UNDER SPECIFIED CONDITIONS. IT IS APPLICABLE TO THE NATIONAL LABOR PROTECTION EQUIPMENT INSPECTION INSTITUTIONS, MASK MANUFACTURERS FOR THE GENERAL MASKS, DUST MASKS, MEDICAL MASKS, ANTI-SMOG MASKS PRODUCTS OF THE RELEVANT TESTING AND INSPECTION.
STANDARD
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
GB 2626-2006 RESPIRATOR SELF-SUCTION FILTER RESPIRATOR AGAINST PARTICULATE MATTER
GB/T 32610-2016 TECHNICAL SPECIFICATIONS FOR DAILY PROTECTIVE MASKS
FEATURES:
1. HIGH-DEFINITION LCD DISPLAY.
2. DIGITAL DIFFERENTIAL PRESSURE METER WITH HIGH PRECISION IMPORTED BRAND.
3. HIGH PRECISION IMPORTED BRAND OF DIGITAL FLOWMETER, WITH HIGH FLOW CONTROL ACCURACY FEATURES.
4. THE RESPIRATOR RESISTANCE TESTER CAN SET UP TWO MODES: EXHALATION DETECTION AND INHALATION DETECTION.
5. AUTOMATIC PIPELINE SWITCHING DEVICE OF RESPIRATOR SOLVES THE PROBLEM OF PIPE EXTUBATION AND WRONG CONNECTION WHEN TESTING.
PARAMETER:
1. FLOWMETER RANGE: 0 ~ 100L/MIN, ACCURACY IS 3%
2. DIGITAL PRESSURE DIFFERENCE METER RANGE: 0 ~ 2000PA, ACCURACY: 1PA
3. PUMPING CAPACITY OF AIR PUMP: >100L/MIN
4. OVERALL SIZE: 460 X 1080 X 670mm
5. POWER SOURCE: AC220V 50HZ 650W
6. WEIGHT: 55KG
QUANTITY: 1
Learn More -
T-6551 MASK FLAME RETARDANT PERFORMANCE TESTERREFERENCE NUMBER: T-6551
MASK FLAME RETARDANT PERFORMANCE TESTER
MASK FLAME RETARDANT PERFORMANCE TESTER
TECHNICAL INDEX:
1.THE LINEAR VELOCITY OF THE NOSE TIP OF THE DIE IS (60 ± 5) MM / S
2.THE DIAMETER OF FLAME TEMPERATURE MEASURINGPROBE IS 1.5MM
3.THE FLAME TEMPERATURE IS (800 ± 50) °C
4.THE DISTANCE BETWEEN THE BURNER TOP AND THE MASK IS (20 ± 2) MM
5.METAL DIE
APPLICABLE STANDARD:
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
YY 0469-2011 MEDICAL SURGICAL MASK
MEDICAL PROTECTIVE MASK REFERS TO A SELF-PRIMING FILTER TYPE DUST-PROOF MEDICAL PROTECTIVE MASK THAT CAN FILTER THE PARTICLES IN THE AIR AND BLOCK THE DROPLETS, BLOOD, BODY FLUIDS, SECRETIONS, ETC.
QUANTITY: 1
Learn More -
T-6552 MASK AIR TIGHTNESS TESTERREFERENCE NUMBER: T-6552
MASK AIR TIGHTNESS TESTER
MASK AIR TIGHTNESS TESTER
HOW TO CHOOSE A HIGH-QUALITY MASK NOT ONLY DEPENDS ON THE FILTERING EFFICIENCY OF THEMASK, BUT ALSO TO CONFIRM WHETHER THE MASK IS COMPLETELY IN CONTACT WITH THE FACE, OTHERWISE AEROSOL PARTICLES SUCH AS GERMS THAT HAVE NOT BEEN FILTERED BY THE MASK WILL BE INHALED FROM THE INADEQUATE ADHESION. THEREFORE, IT IS VERY IMPORTANT TO CHECK THE WEARING STATUS OF THE MASK. THE EUROPEAN AND AMERICAN COUNTRIES HAVE LISTED THE APPLICATION TEST OF THE MASK AS A STRONG INSPECTION ITEM.
FOR EXAMPLE, THE N95 MASK IS ONE OF 9 TYPES OF PARTICULATE PROTECTIVE MASKS CERTIFIED BY NIOSH (NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH). "N" INDICATES OIL RESISTANCE."95" INDICATES THAT THE PARTICLE CONCENTRATION IN THE MASK IS MORE THAN 95% LOWER THAN THAT OF THE PARTICLES OUTSIDE THE MASK WHEN EXPOSED TO THE SPECIFIED NUMBER OF SPECIAL TEST PARTICLES. N95 IS NOT A SPECIFIC PRODUCT NAME, AS LONG AS IT MEETS THE N95 STANDARD AND PASSES THE NIOSH REVIEW, IT CAN BE CALLED "N95 MASK".
N95 TYPE MASKS, IN ADDITION TO THE FILTERING EFFICIENCY OF THE MASKS, THE CLOSENESS OF THE MASKS TO THE FACE IS ONE OF THE IMPORTANT FACTORS THAT DETERMINE THE EFFECTIVENESS OF THE USE OF THE MASKS. THE SUITABILITY OF DIFFERENT TYPES OF MASKS FOR THE HUMAN FACE VARIES GREATLY.
THEREFORE, BEFORE USING A MASK, THE SUITABILITY OF THE MASK SHOULD BE CHECKED FIRST. DURING THETIGHTNESS TEST OF THE WEARER'S FACE, ENSURE THAT AIR CAN PASS IN AND OUT THROUGH THE MASK WHEN IT IS CLOSE TO THE EDGE OF THE FACE. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTION PERFORMANCE. IT CONFORMS TO THE CHINESE RESPIRATOR STANDARD GB2626-2019 STANDARD, OSHA / CSA STANDARD AND CHINA GENERAL ADMINISTRATION OF QUALITY SUPERVISION, INSPECTION AND QUARANTINE "GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS" JOINTLY ISSUED BY THE CHINA NATIONAL STANDARDIZATION ADMINISTRATION COMMITTEE.
ADHESION (SUITABILITY TEST): THE MASK DESIGN SHOULD PROVIDE GOOD ADHESION. THE OVERALL FIT FACTOR OF THE MASK SHOULD NOT BE LESS THAN 100. THIS TEST THE REQUIREMENTS WERE FORMALLY IMPLEMENTED ON AUGUST 1, 2011.
Learn MoreMASK TIGHTNESS TESTER USES CNC TECHNOLOGY, SUITABLE FOR 100 / 99 / P3 / HEPASERIES MASKS DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING DISPOSABLE DUST MASKS SUCH ASN95 / N90 / KN95), GAS MASKS / BREATHING MASKS, ADHESIVENESS TEST OF HALF-MASK AND FULL FACE MASK, INDEPENDENT OR COMPUTER CONTROL, FIVE LANGUAGES SWITCH DISPLAY, EQUIPPED WITH MULTIPLE COMMUNICATION INTERFACES (USB, ETHERNET), WIFI CAN ALSO BE ENABLED, ONE COMPUTERCAN CONTROL FOUR INSTRUMENTS AT THE SAME TIME.PARAMETER:CONCENTRATION RANGE: 0 ~ 100,000 / CM3GRAIN DIAMETER: 0.02 ~ 1.0^MFLOW: SAMPLING FLOW: 100CM3 / MINTOTAL FLOW: 700CM3 / MINCLOSENESS COEFFICIENT TEST: DIRECT TEST (COUT/ CIN)LIQUOR: 99.5% + ISOPROPANOL (ANALYTICAL GRADE)DISPLAY: 7INCH TRUE COLOR TOUCH SCREENCOMMUNICATION INTERFACE: USB X 3 (HOST X 2,DEVICE X 1) ETHERNET INTERFACE X1CONNECTION PORT: ENVIRONMENT PORT, SAMPLING PORTWIFI: EQUIPPEDLANGUAGES: ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESEFLOW CONTROL: SENSOR CONTROLPC CONTROLLABLE OPERATION: ONE COMPUTER CAN CONTROL 4 INSTRUMENTS AT THE SAME TIMEDATA OUTPUT FORMAT: MICROSOFT EXCELWORKING TEMPERATURE: 15 ~ 35 °CPOWER SOURCE: AC 110 —240V 50 / 60HZAPPEARANCE SIZE: 208 X 117 X 262MMWEIGHT: 2.1KGACCESSORIES: ALCOHOL REAGENT BOTTLE, PROTECTIVE CAP, REAGENT STICK, ZERO-COUNT FILTER, STRAINER, SAMPLING TUBE, INSTRUCTION MANUAL, AC ADAPTER, TOUCH SCREEN PEN, OPTIONAL COMPUTER.OPTIONAL: TEST KIT FOR TIGHTNESS COEFFICIENTIN ORDER TO PREVENT INFECTION AT THE MEDICAL SITE AND DURING LABOR WORK, WORKERS MUST BE PROTECTED FROM INHALABLE HAZARDOUS SUBSTANCES IN THE WORKPLACE, AND RESPIRATORS SUCH AS MASKS MUST BE WORN DURING WORK.SELECT A RESPIRATOR, SUCH AS A MASK, BASED ON YOUR FACIAL FEATURES, AND EVALUATE THE TIGHTNESS BETWEEN THE RESPIRATOR, SUCH AS A MASK AND THE FACE, TO CHECK WHETHER THERE ARE GAPS OR LEAKS THAT PUT WORKERS AT RISK. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTIVE PERFORMANCE. SECURITY EXPERTS WILL ALSO DEVELOP PROTECTION SCHEMES AND STANDARD REGULATIONS BASED ON THE RESULTS OF THE TIGHTNESS TEST. WIDELY USED IN HOSPITALS, MANUFACTURING PLANTS, PRODUCTION SITES, FIREFIGHTING WORKPLACES AND OTHER OFFICIAL TESTING AGENCIES.MASK TIGHTNESS TESTER FEATURES:• QUANTITATIVE TIGHTNESS TEST FOR RESPIRATORS SUCH AS MASKS (QNFT)• APPLICABLE TO 100/99 / P3 / HEPA SERIES MASK DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING N95 / N90 / KN95 AND OTHER DISPOSABLE DUST MASKS)• ADHESION TEST OF HALF MASK AND FULL FACE MASK• GAS MASK TIGHTNESS TEST• PAPR MASK TIGHTNESS TEST• SCBA RESPIRATOR MASK TIGHTNESS TEST• 7INCH TRUE COLOR TOUCH SCREEN• INDEPENDENT OR COMPUTER CONTROLLED• USING CNC TECHNOLOGY• ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESE LANGUAGE SWITCHING DISPLAY• COMPLIES WITH US OSHA STANDARDS, CANADIAN STANDARDS ASSOCIATION (CSA) GUIDELINES, INCLUDING N95• EQUIPPED WITH A VARIETY OF COMMUNICATION INTERFACES (USB, ETHERNET), AND CAN ALSO ENABLE WIFI• ONE COMPUTER CAN CONTROL FOUR INSTRUMENTS AT THE SAME TIMEQUANTITY: 1 -
T-6583 PROTECTIVE SUITREFERENCE NUMBER: T-6583
PROTECTIVE SUIT
TWO-PIECE HOODED DESIGN: WITH TWO-PIECE HOODED THREE-DIMENSIONAL CUT AND ELASTIC BAND AROUND THE FACE OPENING, THE HOOD CAN BETTER FIT THE SHAPE OF FACE AND ENHANCE THE PROTECTION EFFECT.
SEAM SEALED TAPE WORKMANSHIP: EACH SEAM IS SEALED WITH TAPE, AND THE WAIST IS APPLIED WITH AN INTERNAL ELASTIC BAND, WHICH BETTER ENHANCE THE SEAM PROTECTION AND THE FITNESS OF THE SUIT.
ELASTIC CUFF: THE CUFF USES AN INTERNAL ELASTIC BAND TO FURTHER ENHANCE TIGHTNESS AND PROTECTION.
CLOSED PLACKET DESIGN: CENTER FRONT ZIPPER APPLICATION ALLOWS EASY PUT-ON AND TAKE-OFF, WHILE THE ZIPPER PLACKET DESIGN BRINGS BETTER PROTECTION
TECHNOLOGICAL DETAILS: (1)NEEDLE STITCHING, BONDING, AND HEAT-SEALING PROCESSES ARE APPLIED TO THE CONNECTION PART OF THE PROTECTIVE SUIT. THE HOLES OF THE STITCHES ARE SEALED. THE STITCH PITCH SHOULD BE 8 TO 14 STITCHES PER 3CM. THE STITCHES ARE ALIGNED AND PROPERLY SPACED. THERE SHOULDN' T BE SKIPPED STITCH. BONDED OR HOT-SEALED PARTS SHALL BE FLAT AND SEALED WITHOUT AIR BUBBLES.
(2)THE ZIPPER OF THE PROTECTIVE CLOTHING SHOULD NOT BE EXPOSED,AND THE ZIPPER PULLER SHOULD BE SELF-LOCKING.
(3)THE STRUCTURE OF PROTECTIVE SUIT SHOULD BE IN CONFORMITY, EASY TO PUT ON AND TAKE OFF, AND THE JOINTS MUST BE TIGHT.
(4)ELASTIC CUFFS AND ANKLES, AND ELASTIC HOOD AND WAIST OPENINGS.
(5)THE PROTECTIVE SUIT IS IN OVERALL STRUCTURE,WHICH CONSISTS OF A HOODED TOP AND PANTS.
Learn More -
T-6581 MEDICAL DISPOSABLE PROTECTIVE CLOTHING SUITREFERENCE NUMBER: T-6581
MEDICAL DISPOSABLE PROTECTIVE CLOTHING SUIT
MEDICAL DISPOSABLE PROTECTIVE CLOTHING SUIT
MEETS GB19082-2009
EN14126 TESTING STANDARD
CAPACITY 100,000 PIECES/DAY(CAPACITY CAN BE ENLARGEDACCORDING TO THE ORDER)
PRODUCTION CAPACITY IS EXPANDING
LARGE QUANTITY IS PREFERRED
THE PAYMENT METHOD IS 100% IN ADVANCE
NOTE: IN THE MASS PRODUCTION OF PROTECTIVE CLOTHING, THE GOVERNMENT, HOSPITALS, AND DISEASE CONTROL CENTERS HAVE PRIORITY IN PURCHASING
MATERIAL: MADE OF 65GWHITE COMPOSITE FILM + 30G NONWOVEN FABRIC + 25G FILM + 3G GLUE + 2.0CM EVA 0.12MMSEALED LINE, TWO PARTS OF PROTECTIVE CLOTHING, HOODEDTOTAL WEIGHT OF CLOTHING IS ABOUT 330-350 G
ONLY HOSPITAL ICU REQUIRED STERILE TYPE, ALL OTHER PLACESREQUIRED NON-STERILE TYPEPACKAGE: MEDICAL PROTECTIVE CLOTHING
CARTON OUTER BOX SIZE: 560 X360 X400mm
SINGLE BOX WEIGHT: 13.5 KG(VOLUME WEIGHT:16.5 KG)45 PIECES PER BOX
MINIMUM ORDER QUANTITY: 10,000 PIECES
Learn More -
V-1819 KN95 MASKS AVAILABLE FOR SALE, CE CERTIFIEDSTANDARD: GB2626-2006 KN95
0.3 MICRON PARTICULATE FILTERING > 95%
BUILT-IN ADJUSTABLE SOFT NOSE CLIP
4 LAYERS (4 PLY) IS AVAILABLE NOW
3 LAYERS (3 PLY) CAN ALSO BE MADE
ALL MASKS PASSED CE CERTIFICATIONQUANTITY:
Learn More
4 MASKS PER BAG
160 BAGS PER CARTON = 640 MASKS PER CARTON
350 CARTONS IN A 20 FOOT CONTAINER= 224,000 MASKS PER CONTAINER
WEIGHT AND DIMENSIONS OF ONE CARTON:
GROSS WEIGHT: 5.485 KG
DIMENSIONS: 520mm x 320mm x 480mm -
H-2413 RIB CIRCULAR KNITTING MACHINE 5”CYLINDER DIAMETER: 5”
NO. OF FEEDERS: 10
130 NEEDLESGOLDEN ROC NEEDLE
DIAL 43.50 NEEDLE 2 TYPES
CYLINDER 122.48
NEEDLE 2 TYPES
NEEDLE DETECTOR: 6 PCS
DIGITAL CONTROL PANEL
CAM: 1 SET (MADE OF ALLOY STEEL, JAPAN)
CYLINDER 2 TRACKS, DIAL 2 TRACKS
TOTAL CAMS: 40 PCS
PNEUMATIC OIL LUBRICATOR
SMG POSITIVE STORAGE FEEDER
YARN FEEDING TOOTHED BELT
CYLINDER (MADE OF ALLOY STEEL, JAPAN)
INVERTER
LYCRA FEEDER
MOTOR
CREEL HOLDERS
FABRIC ROLLING MACHINESPARE PARTS:
CAM × 1 PC/TYPE
TOOLBOX (WITH TOOLS INSIDE) × 1 PC
NEEDLE DETECTOR × 2 PCS
NEEDLE × 100 PCS
YARN CARRIER × 2 PCS
POSITIVE STORAGE FEEDER × 2 PCSSHIPPING DIMENSIONS (WOODEN CASE): LENGTH 1600mm, WIDTH 1100mm, HEIGHT 2200mm 3.87 CBM
GROSS WEIGHT: 550 KGSQUANTITY: 1
Learn More