Search results for: 'equip'
- Related search terms
- equipm
- equipments f
- equipments for
- equipments for su
- equipments+for
- M-6050 COMPLETE NONWOVEN PRODUCTION LINE, WORKING WIDTH 2500mm TO 4000mm, YEAR 1974 TO 2005
M-6050 COMPLETE NONWOVEN PRODUCTION LINE, WORKING WIDTH 2500mm TO 4000mm, YEAR 1974 TO 2005
OFFER 001
ITALIAN REGENERATION BEATING OPENER (WILLOW)OFFER 002
RAMELLA CARDING MACHINEOFFER 003
2N (TECTEX) CROSS LAPPEROFFER 004
AUTOMATEX NEEDLE LOOMOFFER 005
FEHRER NEEDLE LOOMOFFER 006
MTV LONGITUDINAL CUTTER WITH 5 DISC BLADESOFFER 007
DUST COLLECTOR (FILTER)QUANTITY: 1 LINE
Learn More - C-3939 BONINO CARDING MACHINE, WIDTH 3500mm
C-3939 BONINO CARDING MACHINE, WIDTH 3500mm
BONINO CARDING MACHINE
BRAND: BONINO
WIDTH: 3500mmQUANTITY: 1
Learn More - M-5268 ISOTEX TWO HEAD COATING LINE FOR PVC AWNINGS AND TARPAULINS YEAR 1976-2005 – 1600mmREFERENCE NUMBER: M-5268 (1313BSLTXX12X) L ISOTEX TWO HEAD COATING LINE FOR PVC AWNINGS AND TARPAULINS YEAR 1976-2005 – 1600mm 2-HEAD COATING LINE FOR PVC AWNINGS AND OTHER APPLICATIONS MANUFACTURER: ISOTEX / ITALY YEAR OF CONSTRUCTION: 1976 / 2005 ROLLER WIDTH: 1800mm WORKING WIDTH: 1600mm WORKING VELOCITY: 0 ~ 20 M/MIN TEMPERATURE MAXIMUM: 270 °C QUANTITY AVAILABLE: 1 Learn More
- BENNINGER SIZING MACHINE, WIDTH 2400mm, YEAR 2003REFERENCE NUMBER: T-6983 BENNINGER SIZING MACHINE, WIDTH 2400mm, YEAR 2003 BENNINGER SIZING MACHINE YEAR 2003 WIDTH 2400mm DOUBLE STOCK TANK 12 PCS CYLINDER EQUIPPED BENNINGER WARPING MACHINE 24 WARP BEAMS QUANTITY: 1 Learn More
- SPINNBAU DOUBLE DOFFER NON-WOVEN CARD 2500mmREFERENCE NUMBER: Y-2075 SPINNBAU DOUBLE DOFFER NON-WOVEN CARD 2500mm RECONDITIONED CARD SPECIFICATION: 2500mm WORKING WIDTH DISH FEEF ARRANGEMENT WITH FEED ROLLER 159mm 1 LICKER-IN 292mm 1 BREAST 412mm WITH 1 WORKER 213mm AN 1 STRIPPER 105mm 1 TRANSFER 412mm 1 SWIFT 1500mm WITH 6 WORKERS 213mm AND 6 STRIPPERS 105mm 1 TOP DOFFER 500mm 1 BOTTOM DOFFER 550mm 2 BOTTOM RANDOMISER ROLLERS 292mm 2 BOTTOM RANDOMISER ROLLERS 292mm TOP DOFFER DOFFING ROLLER SYSTEM 2 ROLLER 105mm AND 105mm CARD MOUNTED ON RAILS WITH PLATFORM SPINNBAU GUARDING SYSTEM FITTED WITH THE FOLLOWING NEW EQUIPMENT: NEW HIGH CAPACITY HOPPER FEEDER WITH CHUTE DELIVERY ELECTRONIC WEIGHT SYSTEM NEW AC INVERTER DRIVES SYSTEM WITH TOUCH SCREEN CONTROL NEW AC GEARED MOTOR UNITS NEW DRIVE BELTS AS REQUIRED NEW SAFETY CIRCUIT, E-STOPS AND GUARD INTERLOCKS HOPPER FEEDER WITH CHUTE DELIVERY 2500mm WIDE 1500mm FEEDER CONVEYOR PVC WITH WOOD LATHS WITH GEARED MOTOR DRIVE INCLINED SPIKED LATTICE PVC WITH WOOD LATHS WITH GEARED MOTOR DRIVE LEVELLING ROLLER WITH GEARED MOTOR DRIVE STRIPPING ROLLER WITH GEARED MOTOR DRIVE VOLUMETRIC CHUTE DELIVERY VIBRATING BACKPLATE WITH GEARED MOTOR DRIVE CHUTE THICKNESS ADJUSTABLE DELIVERY ROLLERS TO BE DRIVEN FROM CARD FEED SHEET ELECTRICAL CONTROLS WITH VARIABLE SPEED DRIVE TO SPIKED LATTICE, OR STRIPPING ROLLERS AND VIBRATING BACKPLATE QUANTITY: 1 Learn More
- T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
REFERENCE NUMBER: T-6547
RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
INTRODUCTION
THE RESPIRATOR RESISTANCE TESTER IS USED TO MEASURE THE INSPIRATORY RESISTANCE AND EXPIRATORY RESISTANCE OF RESPIRATORS AND RESPIRATOR PROTECTORS UNDER SPECIFIED CONDITIONS. IT IS APPLICABLE TO THE NATIONAL LABOR PROTECTION EQUIPMENT INSPECTION INSTITUTIONS, MASK MANUFACTURERS FOR THE GENERAL MASKS, DUST MASKS, MEDICAL MASKS, ANTI-SMOG MASKS PRODUCTS OF THE RELEVANT TESTING AND INSPECTION.
STANDARD
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
GB 2626-2006 RESPIRATOR SELF-SUCTION FILTER RESPIRATOR AGAINST PARTICULATE MATTER
GB/T 32610-2016 TECHNICAL SPECIFICATIONS FOR DAILY PROTECTIVE MASKS
FEATURES:
1. HIGH-DEFINITION LCD DISPLAY.
2. DIGITAL DIFFERENTIAL PRESSURE METER WITH HIGH PRECISION IMPORTED BRAND.
3. HIGH PRECISION IMPORTED BRAND OF DIGITAL FLOWMETER, WITH HIGH FLOW CONTROL ACCURACY FEATURES.
4. THE RESPIRATOR RESISTANCE TESTER CAN SET UP TWO MODES: EXHALATION DETECTION AND INHALATION DETECTION.
5. AUTOMATIC PIPELINE SWITCHING DEVICE OF RESPIRATOR SOLVES THE PROBLEM OF PIPE EXTUBATION AND WRONG CONNECTION WHEN TESTING.
PARAMETER:
1. FLOWMETER RANGE: 0 ~ 100L/MIN, ACCURACY IS 3%
2. DIGITAL PRESSURE DIFFERENCE METER RANGE: 0 ~ 2000PA, ACCURACY: 1PA
3. PUMPING CAPACITY OF AIR PUMP: >100L/MIN
4. OVERALL SIZE: 460 X 1080 X 670mm
5. POWER SOURCE: AC220V 50HZ 650W
6. WEIGHT: 55KG
QUANTITY: 1
Learn More - P-8696 ULTRASONIC SEWING MACHINE
REFERENCE NUMBER: P-8696
ULTRASONIC SEWING MACHINE
CAN BE USED WITH EITHER 20 KHz, 30 KHz OR 40 KHz EQUIPMENT
LED DISPLAY FOR EASY PROCESS MONITORING
19” (483mm) THROAT
INDEPENDENT CONTROLS FOR SLITTING AND ROTARY ANVIL WELDING
DUAL SEALING CAPABILITIES WITH INDEPENDENT ADJUSTMENTS
EDGE GUIDING, REWINDING, AND FEED ROLLS CAN BE USED
CAN BE OPERATOR CONTROLLED AS A BENCHTOP UNIT OR INTEGRATED INTO AN EXISTING LINE
QUANTITY: 1
- T-6575 NON-INVASIVE VENTILATOR
NON-INVASIVE VENTILATOR
Learn More
CERTIFICATE: CE
MEDICAL VENTILATOR
TECHNICAL PARAMETERS OF DOUBLE LEVEL VENTILATOR
VENTILATOR TYPE: ELECTRIC CONTROL
SCOPE OF APPLICATION: TREATMENT AND TITRATION OF SLEEP APNEA HYPOPNEA SYNDROME, SEVERE SNORING, AND RESPIRATORY INSUFFICIENCY.
DISPLAY INTERFACE: 3.5-INCH LED SCREEN, CHINESE OPERATING SYSTEM
*VENTILATION MODE: CPAP, S, S/T, T
PRESSURE RANGE:
PRESSURE RANGE: 4-30CMH2O (±0.5CMH2O)
PRESSURE ACCURACY: + 0.5CMH2O
PARAMETER SETTING:
DELAYED BOOST: 0-60MIN, SET THE DIVISION INTERVAL 5MIN
INITIAL PRESSURE: 4CMH2O TREATMENT PRESSURE / RESPIRATORY PRESSURE SETTING
THERAPEUTIC PRESSURE: 4-20CMH2O (IN CPAP MODE)
TARGET TIDAL VOLUME: 150ML - 1500ML, ON/ OFF
MAXIMUM SUCTION PRESSURE: 4-30CMH2O, (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
MINIMUM SUCTION PRESSURE: 4-30CMH2O (NOT HIGHER THAN THE SUCTION PRESSURE), (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
INSPIRATORY PHASE PRESSURE: 4-30CMH2O
EXPIRATORY PRESSURE: 4-30CMH2O
EXPIRATORY DECOMPRESSION: PATIENT, OFF, 1-3, THREE ADJUSTABLE
MANUAL VOLTAGE REGULATION: 0-2 GEAR, 0-2CMH2O (ONLY AVAILABLE IN CPAP MODE)
INSPIRATORY SENSITIVITY: 1-8 STALLS
EXPIRATORY SENSITIVITY: 1-8 STALLS
RESPIRATORY FREQUENCY: 3-40 TIMES / MIN
INSPIRATORY TIME: 0.3-3.0S
BACKUP RATE: ON / OFF, DEFAULT 10
PRESSURE RISE TIME: 1-4 STALLS
HUMIDIFIER: 1-5 ADJUSTABLE IN 5 GEARS
*TITRATION FUNCTION: SUPPORT MANUAL AND AUTOMATIC PRESSURE TITRATION, BUILT-IN REMOTE WIRELESS COMMUNICATION MODULE, COMPLETE THE RANDOM SWITCHING OF SINGLE AND DOUBLE LEVEL MODES IN THE TITRATION PROCESS, AND CONTROL MORE THAN 11 VENTILATOR PARAMETERS AT THE SAME TIME.
AUXILIARY FUNCTION: AUTOMATIC AIR LEAKAGE COMPENSATION, AUTOMATIC STARTUP, AUTOMATIC SHUTDOWN, DELAYED SHUTDOWN, SCREEN BACKLIGHT ADJUSTMENT
MONITORING PARAMETERS: PRESSURE, TIDAL VOLUME, RESPIRATORY RATE, MINUTE VENTILATION VOLUME, AIR LEAKAGE VOLUME, INSPIRATORY TIME, BLOOD OXYGEN SATURATION
WAVY CURVE: PRESSURE TIME WAVEFORM, FLOW RATE TIME WAVEFORM
ALARM PROMPT: PIPELINE AND MASK FALLING OFF, AIR LEAKAGE PROMPT, POWER INTERRUPTION, TREATMENT MACHINE FAILURE, HUMIDIFIER FAILURE, LOW VOLTAGE, HIGH RESPIRATORY RATE, LOW RESPIRATORY RATE, LOW MINUTE VENTILATION VOLUME, LOW BLOOD OXYGEN, REPLACEMENT OF FILTER COTTON, FULL SD CARD, RE INSERTION OF SD CARD
*DATA MANAGEMENT:
NETWORK DATA: BMC + RESPIRATORY HEALTH MANAGEMENT CLOUD PLATFORM
SD CARD DATA: RESART NPAP DATA ANALYSIS SOFTWARE
PARTS:
SD CARD: STANDARD
SD CARD SLOT: STANDARD
PIPING: 9 22MM, 1.8M LONG
FACE SHIELD: F2 NOSE MASK AS STANDARD
NOISE: LESS THAN 30DB
ENVIRONMENT CONDITION:
TEMPERATURE:
(WHEN USED) 5 -35 C
(DURING TRANSPORTATION AND STORAGE) -20 C -55 C
ATMOSPHERIC PRESSURE:
(WHEN USED) 760-1060HPA
(DURING TRANSPORTATION AND STORAGE) 760-1060HPA
WORKING HOURS: MORE THAN 8 HOURS
POWER SUPPLY REQUIREMENTS:
AC VOLTAGE: 100-240V
FREQUENCY: 50HZ/60HZ
INPUT POWER: LESS THAN 2A
WATERPROOF LEVEL: IP22 - DRIP PROOF EQUIPMENT
INSTRUMENT SIZE: 290mm X 180mm X 134mm
WEIGHT: 1.5KG (EXCLUDING HUMIDIFIER) 2.5KG (INCLUDING HUMIDIFIER)
ITEM 001
QUANTITY: 10 SETS-999 SETS
ITEM 002
QUANTITY: 1,000 SETS-9,999SETS
ITEM 003
QUANTITY: ≥10,000 SETS - J-2786 VERTICAL MODULE FOR TEMPERATURE MEASUREMENT & FACE RECOGNITION
USES ROCKCHIP RK3288 / RK 3399 / QUALCOMM MSM8953 HIGH-PERFORMANCE HARDWARE PLATFORM, EQUIPPED WITH INDUSTRIAL GRADE BINOCULAR CAMERA, LIVE FACIAL RECOGNITION SOFTWARE AND INFRARED THERMAL IMAGING MODULE TO SUPPORT FACE-WITH-MASK INDEITIFICATION.
SUPPORTS EXPANSION OF VARIOUS PERIPHERALS SUCH AS ID CARD READERS, FINGERPRINT READERS, ETC WHICH CAN BE APPLIED TO GATE PASSAGES AND ATTENDANCE SYSTEM TO ACHIEVE SAFE AND EFFICIENT ACCESS CONTROL FOR PERSONNEL
CAN BE USED WITH ACCESS GATES & ATTENDANCE FOR COMMUNITIES, OFFICES, SCHOOLS, HOTELS, PUBLIC VENUES, TRANSPORTATION HUBS AND PUBLIC SERVICE PLACES
FEATURES:
8 INCH IPS FULL-VIEW LCD DISPLAY
INDUSTRIAL APPEARANCE, WATERPROOF AND SUNPROOF DESIGN
STABLE AND RELIABLE
SUPPORTS A DATABASE OF 30,000 FACES
THE 1:1 COMPARISON RECOGNITION RATE IS MORE THAN 99.7%
THE 1:N COMPARISON RECOGNITION RATE IS MORE THAN 96.7% @ 0.1% MISRECOGNITION RATE
LIVE DETECTION ACCURACY RATE: 98.3% @ 1% MISRECOGNITION RATE
FACE RECOGNITION PASS SPEED IS LESS THAN 1 SECOND
SUPPORTS ACCURATE FACE RECOGNITION AND COMPARISON WHILE WEARING A MASK
USES INDUSTRIAL GRADE BINOCULAR WIDE DYNAMIC CAMERA, NIGHT INFRARED AND LED DUAL PHOTO FLOOD LAMP
ROCKCHIP RK3288 QUAD-CORE PROCESSOR, ROCKCHIP RK3399 SIX-CORE PROCESSOR, AND QUALCOMM MSM8953 OCTA-CORE PROCESSOR
SUPPORTS HUMAN BODY TEMPERATURE DETECTION AND DISPLAY (BEST TEMPERATURE DETECTION DISTANCE IS 0.5 METERS, MAXIMUM IS 1 METER), MEASUREMENT ERROR +/- 0.5 °C
TEMPERATURE CAN BE READ IN ONLY A FEW SECONDS AND THE DEVICE AUTOMATICALLY SOUNDS AN ALARM FOR ABNORMALITIES
ATTENDANCE TEMPERATURE MEASUREMENT DATA EXPORTED IN REAL TIME
VARIOUS PERIPHERALS AVAILABLE FOR ID CARD READING, FINGERPRINT READING, IC CARD READING, 2-DIMENSIONAL CODE READING, ETC.
WITH COMPLETE DOCUMENTATION AND SUPPORT FOR SECONDARY DEVELOPMENT
SUPPORTS SYSTEM LEVEL, APP OFFLINE LEVEL, APP AND BACKGROUND NETWORK LEVEL MULTIPLE API DOCKINGCAMERA
RESOLUTION 2 MILLION PIXELS
TYPE BINOCULAR WIDE DYNAMIC CAMERA
APERTURE F2.4
FOCUSING DISTANCE 50-150CM
WHITE BALANCE AUTO
PHOTO FLOOD LIGHT LED AND IR DUAL PHOTO FLOOD LIGHTSCREEN
SIZE 8.0 INCH IPS LCD SCREEN
RESOLUTION 800×1280
TOUCH NOT SUPPORTED (OPTIONAL SUPPORT)PROCESSOR
CPU RK3288 QUAD-CORE (OPTIONAL RK3399 SIX-CORE, MSM8953
EIGHT-CORE)
STORAGE EMMC 8GINTERFACE
NETWORK MODULE ETHERNET AND WIRELESS (WIFI)
AUDIO 2.5W / 4R SPEAKERS
USB 1 USB OTG, 1 USB HOST STANDARD A PORT
SERIAL COMMUNICATION 1 RS232 SERIAL PORT
RELAY OUTPUT 1 DOOR OPEN SIGNAL OUTPUT
WIEGAND ONE WIEGAND 26/34 OUTPUT, ONE WIEGAND 26/34 INPUT
UPGRADE BUTTON SUPPORT UBOOT UPGRADE BUTTON
WIRED NETWORK 1 RJ45 ETHERNET SOCKETFUNCTION
CREDIT CARD READER NONE (OPTIONAL IC CARD READER, ID CARD, ID CARD)
FACE DETECTION SUPPORTS DETECTION AND TRACKING OF MULTIPLE PEOPLE AT THE SAME
TIME
FACE LIBRARY UP TO 30,000
1: N FACE RECOGNITION SUPPORT
1: 1 FACE COMPARISON SUPPORT
STRANGER DETECTION SUPPORT
IDENTIFY DISTANCE
CONFIGURATION
SUPPORT
UI INTERFACE CONFIGURATION SUPPORT
UPGRADE REMOTELY SUPPORT
INTERFACE INTERFACES INCLUDE DEVICE MANAGEMENT, PERSONNEL / PHOTO
MANAGEMENT, RECORD QUERY, ETC.
DEPLOYMENT METHOD SUPPORT PUBLIC CLOUD DEPLOYMENT, PRIVATIZED DEPLOYMENT, LAN
USE, STAND-ALONE USEINFRARED THERMAL IMAGING MODULE
TEMPERATURE DETECTION SUPPORT
TEMPERATURE DETECTION 1 METER (OPTIMAL DISTANCE 0.5 METER)
DISTANCE
TEMPERATURE
MEASUREMENT ACCURACY
≤ ±0.5℃
TEMPERATURE
MEASUREMENT RANGE
10℃~42℃
THERMAL FIELD OF VIEW 32 X 32℃
VISITORS' TEMPERATURE IS
NORMAL AND RELEASED
DIRECTLY
SUPPORT
ABNORMAL TEMPERATURE
ALARM
SUPPORT (TEMPERATURE ALARM VALUE CAN BE SET)GENERAL PARAMETERS
POWER DC12V(±10%)
OPERATING TEMPERATURE 0℃~60℃
STORAGE TEMPERATURE -20℃~60℃
POWER CONSUMPTION 13.5W(MAX)
INSTALLATION METHOD GATE BRACKET INSTALLATION
SIZE : STANDARD:274.24*128*21.48(MM); IC CARD / ID CARD:296.18*132.88*25(MM)PACKING LIST
Learn More
MACHINE * 1, POWER ADAPTER * 1, MANUAL * 1, CERTIFICATE OF CONFORMITY * 1 - V-1820 MASK AND RESPIRATOR FIELD TESTER
MAINLY USED FOR VISUAL FIELD TESTING OF MASKS AND RESPIRATORS, WHICH IS USEFUL FOR MASK AND RESPIRATOR MANUFACTURERS, QUALITY SUPERVISORS, SCIENTIFIC RESEARCH, AND FOR TESTING PRIOR TO SELLING MASKS.
FEATURES:
1. THE EQUIPMENT IS COMPOSED OF A SEMI-ARC BOW, RECORDING DEVICE, SEAT FRAME AND TEST HEAD DIE.
2. SEMI-ARC BOW: THE RADIUS IS 300 TO 340 mm
CAN BE ROTATED AROUND THE HORIZONTAL RADIUS PLANE PASSING THROUGH THE POINT 0°, AND A SCALE EXTENDING TO THE 90° ARC BOW EVERY 5° FROM 0° ON BOTH SIDES, EQUIPPED WITH SLIDING WHITE VISUAL STANDARD.
3. RECORDING DEVICE: THE RECORDING NEEDLE IS CONNECTED WITH THE VISUAL STANDARD THROUGH COMPONENTS SUCH AS AXLE WHEEL, AND THE DIRECTION AND ANGLE OF THE VISUAL STANDARD ARE RECORDED ON THE VISUAL FIELD DRAWING CORRESPONDINGLY.
4. SEAT FRAME: USED TO SUPPORT SEMI-CIRCULAR ARC BOW AND FIXED RECORDING DEVICE.
5. TEST THE HEAD MOLD: A STANDARD HEAD MOLD, THE TWO EYE HOLES OF THE HEAD MOLD ARE EQUIPPED WITH SMALL LIGHT BULBS, THE POSITION OF THE BULB AND THE POSITION OF THE HEAD MOLD ARE ACCORDING TO THE REQUIREMENTS OF GB 2890. THE TEST HEAD DIE MUST BE INSTALLED ON THE WORKBENCH IN SUCH A WAY THAT THE LEFT AND RIGHT EYES ARE PLACED AT THE CENTER OF THE SEMICIRCULAR ARCH AND THE "0" POINT IS DIRECTLY SEEN.MAIN INDICATORS
Learn More
1. SEMI-CIRCULAR ARC RADIUS: 335mm.
2. LEFT AND RIGHT FIELD OF VIEW: ≤120°.
3. BULB DISTANCE: THE VERTEX OF THE BULB IS CONNECTED AFTER THE TWO EYE POINTS (7±0.5).
APPLICABLE STANDARDS: GB/T 32610-2016, GB 2626-2019, GB2890-2009