- T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
REFERENCE NUMBER: T-6547
RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
INTRODUCTION
THE RESPIRATOR RESISTANCE TESTER IS USED TO MEASURE THE INSPIRATORY RESISTANCE AND EXPIRATORY RESISTANCE OF RESPIRATORS AND RESPIRATOR PROTECTORS UNDER SPECIFIED CONDITIONS. IT IS APPLICABLE TO THE NATIONAL LABOR PROTECTION EQUIPMENT INSPECTION INSTITUTIONS, MASK MANUFACTURERS FOR THE GENERAL MASKS, DUST MASKS, MEDICAL MASKS, ANTI-SMOG MASKS PRODUCTS OF THE RELEVANT TESTING AND INSPECTION.
STANDARD
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
GB 2626-2006 RESPIRATOR SELF-SUCTION FILTER RESPIRATOR AGAINST PARTICULATE MATTER
GB/T 32610-2016 TECHNICAL SPECIFICATIONS FOR DAILY PROTECTIVE MASKS
FEATURES:
1. HIGH-DEFINITION LCD DISPLAY.
2. DIGITAL DIFFERENTIAL PRESSURE METER WITH HIGH PRECISION IMPORTED BRAND.
3. HIGH PRECISION IMPORTED BRAND OF DIGITAL FLOWMETER, WITH HIGH FLOW CONTROL ACCURACY FEATURES.
4. THE RESPIRATOR RESISTANCE TESTER CAN SET UP TWO MODES: EXHALATION DETECTION AND INHALATION DETECTION.
5. AUTOMATIC PIPELINE SWITCHING DEVICE OF RESPIRATOR SOLVES THE PROBLEM OF PIPE EXTUBATION AND WRONG CONNECTION WHEN TESTING.
PARAMETER:
1. FLOWMETER RANGE: 0 ~ 100L/MIN, ACCURACY IS 3%
2. DIGITAL PRESSURE DIFFERENCE METER RANGE: 0 ~ 2000PA, ACCURACY: 1PA
3. PUMPING CAPACITY OF AIR PUMP: >100L/MIN
4. OVERALL SIZE: 460 X 1080 X 670mm
5. POWER SOURCE: AC220V 50HZ 650W
6. WEIGHT: 55KG
QUANTITY: 1
Learn More - T-6548 FABRIC SURFACE WETTING TESTER
REFERENCE NUMBER: T-6548
FABRIC SURFACE WETTING TESTER
INSTRUMENT TECHNICAL DESCRIPTION:
WATER TESTER IS TO INSTALL THE SAMPLE ON THE SAMPLE HOLDER AND MAKE AN ANGLE OF 45 ° WITH THE LEVEL. THE CENTER OF THE SAMPLE IS LOCATED AT A SPECIFIED DISTANCE BELOW THE NOZZLE. THE SAMPLE IS SPRAYED WITH A SPECIFIED VOLUME OF DISTILLED OR DEIONIZED WATER. BY COMPARING THE APPEARANCE OF THE SAMPLE WITH THE EVALUATION STANDARDS AND PICTURES TO DETERMINE ITS WATER-SOAKING GRADE, IT IS SUITABLE FOR MEASURING VARIOUS WATER-SOAKING TESTS ON THE SURFACE OF FABRICS WITH OR WITHOUT WATER RESISTANCE AND WATER REPELLENT FINISHING. THIS INSTRUMENT IS NOT SUITABLE FOR MEASURING THE WATER PERMEABILITY OF FABRICS, SO IT CANNOT BE USED TO PREDICT THE RAINPROOF PERMEABILITY OF FABRICS.
STANDARD:
GB19082-2009 TECHNICAL REQUIREMENTS FOR MEDICAL PRIMARY PROTECTIVE CLOTHINGGB / T4745 SURFACE MOISTURE RESISTANCE TEST
THE MAIN TECHNICAL INDICATORS OF THE INSTRUMENT:
GLASS FUNNEL: φ150mm
MEASURING CUP: 500ML
SAMPLE SUPPORT ANGLE: 45 °
INSTRUMENT CONFIGURATION:
1. ONE HOST
2. A GLASS FUNNEL
3. 500ML MEASURING CUP
QUANTITY: 1
Learn More - T-6550 MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTER
REFERENCE NUMBER: T-6550
MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTER
TECHNICAL SPECIFICATIONS AND CONFIGURATION:
1. THE INSTRUMENT ADOPTS AN AIR SOURCE THAT CAN PROVIDE (0.5 ~ 30±0.1) KPA PRESSURE TO CONTINUOUSLY PRESSURIZED THE SAMPLE, WHICH IS NOT RESTRICTED BY THE SPACE OF THE TEST SITE;
2. THE AIR PRESSURE RANGE CAN BE ADJUSTED FREELY, AND THE ADJUSTMENT RANGE (0.5 ~ 30) KPA;
3. COLOR TOUCH SCREEN DISPLAY AND OPERATION;
4. THE SAMPLE CLAMPING PAD IS PROCESSED WITH IMPORTED SPECIAL ALUMINUM PROFILES, WHICH IS LIGHT IN MATERIAL, CLEAN IN SURFACE AND NEVER RUSTS.
5. THE INSTRUMENT ADOPTS IMPORTED SPECIAL ALUMINUM WIRE DRAWING PANEL, EQUIPPED WITH METAL KEYS, SENSITIVE OPERATION, NOT EASY TO DAMAGE;
6. CLAMPING DEVICE FOR INSTRUMENT SAMPLES, EQUIPPED WITH LOCKING PROTECTION, TO PREVENT THE SYNTHETIC BLOOD FROM SPLASHING AROUND;
7. CLAMPING FORCE IS ACCURATE AND RELIABLE;
8. THE TEST TANK IS EQUIPPED WITH A SPECIAL PLACEMENT DEVICE, WHICH IS CONVENIENT FOR CUSTOMERS TO OPERATE;
9. THE TEST TANK IS PROCESSED WITH SPECIAL 316 STAINLESS STEEL, AND THE TOP IS EQUIPPED WITH A SPECIAL COVER FOR HIGH TRANSPARENT PROTECTION;
10. THE WASHER BELOW THE SAMPLE IS MADE OF HIGH-QUALITY PTFE MATERIAL AFTER SPECIAL PROCESSING;
11. SQUARE METAL BLOCK NET: OPEN SPACE ≥50°%; BENDING ≤5mm AT 30KPA;
12. INSTRUMENT TIME CONTROL ACCURACY ≤01 SECONDS;
13. THE SHELL OF THE INSTRUMENT IS MADE OF HIGH-QUALITY METAL BAKING PAINT, WHICH IS BEAUTIFUL AND GENEROUS.
14. EQUIPPED WITH PRINTER INTERFACE, CONNECTED TO THE PRINTER CAN DIRECTLY PRINT DATA REPORTS.
TECHNICAL PARAMETERS:
1. SAMPLE SIZE: 75mm X 75mm
2. TEST AREA: 28.26 SQUARE CENTIMETERS
3. AIR PRESSURE ADJUSTMENT RANGE (0.5 ~ 30) KPA
4. EXTERNAL SIZE: 500mm X 500mm X 500mm (L X W X H)
5. WEIGHT OF THE INSTRUMENT: 40 KG
6. POWER SUPPLY: AC220V, 50HZ,SCOPE OF SUPPLY: 1. ONE MAIN MACHINE; 2. TWO PTFE GASKETS; 3. TWO ORDINARY WASHERS; 4. ONE METAL BLOCKING NET; 5. A SET OF SPECIAL LOCKING TOOLS; 6. ONE HIGH-QUALITY SILENT AIR PUMP, [NOTE: SAFETY PRODUCTION LICENSE IS NOT INCLUDED]. 7. EQUIPPED WITH PRINTER INTERFACE; 8. ONE SAMPLE TEMPLATE; 9. ONE PRODUCT CERTIFICATE; 10. ONE COPY OF PRODUCT OPERATION MANUAL.
OPERATION INSTRUCTION:
INSERT THE AIR PUMP OUTPUT PIPE INTO THE OIL AND WATER SEPARATOR OF THE INSTRUMENT AS REQUIRED (PRESSURE 0.1-0.3MPA).
AFTER SWITCHING ON THE POWER, THE STARTUP INTERFACE (NAME OF THE DEVICE) IS DISPLAYED.
PRESS THE "ENTER" BUTTON TO ENTER THE TEST INTERFACE, AS SHOWN IN THE FOLLOWING FIGURE:
CLICK "SETTING” BUTTON, GET INTO PARAMETER SETTING SCREEN, AS BELOW THIS SCREEN CAN SET THE SYSTEM TIME, DATE AND TESTING TIME, AFTER SETTING, CLICK "SAVE” BUTTON TO KEEP THE SETTING DATA. (NOTE: IT REQUIRES 5 MINUTES IN THE STANDARD)
QUANTITY: 1
Learn More - T-6552 MASK AIR TIGHTNESS TESTER
REFERENCE NUMBER: T-6552
MASK AIR TIGHTNESS TESTER
MASK AIR TIGHTNESS TESTER
HOW TO CHOOSE A HIGH-QUALITY MASK NOT ONLY DEPENDS ON THE FILTERING EFFICIENCY OF THEMASK, BUT ALSO TO CONFIRM WHETHER THE MASK IS COMPLETELY IN CONTACT WITH THE FACE, OTHERWISE AEROSOL PARTICLES SUCH AS GERMS THAT HAVE NOT BEEN FILTERED BY THE MASK WILL BE INHALED FROM THE INADEQUATE ADHESION. THEREFORE, IT IS VERY IMPORTANT TO CHECK THE WEARING STATUS OF THE MASK. THE EUROPEAN AND AMERICAN COUNTRIES HAVE LISTED THE APPLICATION TEST OF THE MASK AS A STRONG INSPECTION ITEM.
FOR EXAMPLE, THE N95 MASK IS ONE OF 9 TYPES OF PARTICULATE PROTECTIVE MASKS CERTIFIED BY NIOSH (NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH). "N" INDICATES OIL RESISTANCE."95" INDICATES THAT THE PARTICLE CONCENTRATION IN THE MASK IS MORE THAN 95% LOWER THAN THAT OF THE PARTICLES OUTSIDE THE MASK WHEN EXPOSED TO THE SPECIFIED NUMBER OF SPECIAL TEST PARTICLES. N95 IS NOT A SPECIFIC PRODUCT NAME, AS LONG AS IT MEETS THE N95 STANDARD AND PASSES THE NIOSH REVIEW, IT CAN BE CALLED "N95 MASK".
N95 TYPE MASKS, IN ADDITION TO THE FILTERING EFFICIENCY OF THE MASKS, THE CLOSENESS OF THE MASKS TO THE FACE IS ONE OF THE IMPORTANT FACTORS THAT DETERMINE THE EFFECTIVENESS OF THE USE OF THE MASKS. THE SUITABILITY OF DIFFERENT TYPES OF MASKS FOR THE HUMAN FACE VARIES GREATLY.
THEREFORE, BEFORE USING A MASK, THE SUITABILITY OF THE MASK SHOULD BE CHECKED FIRST. DURING THETIGHTNESS TEST OF THE WEARER'S FACE, ENSURE THAT AIR CAN PASS IN AND OUT THROUGH THE MASK WHEN IT IS CLOSE TO THE EDGE OF THE FACE. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTION PERFORMANCE. IT CONFORMS TO THE CHINESE RESPIRATOR STANDARD GB2626-2019 STANDARD, OSHA / CSA STANDARD AND CHINA GENERAL ADMINISTRATION OF QUALITY SUPERVISION, INSPECTION AND QUARANTINE "GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS" JOINTLY ISSUED BY THE CHINA NATIONAL STANDARDIZATION ADMINISTRATION COMMITTEE.
ADHESION (SUITABILITY TEST): THE MASK DESIGN SHOULD PROVIDE GOOD ADHESION. THE OVERALL FIT FACTOR OF THE MASK SHOULD NOT BE LESS THAN 100. THIS TEST THE REQUIREMENTS WERE FORMALLY IMPLEMENTED ON AUGUST 1, 2011.
MASK TIGHTNESS TESTER USES CNC TECHNOLOGY, SUITABLE FOR 100 / 99 / P3 / HEPASERIES MASKS DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING DISPOSABLE DUST MASKS SUCH ASN95 / N90 / KN95), GAS MASKS / BREATHING MASKS, ADHESIVENESS TEST OF HALF-MASK AND FULL FACE MASK, INDEPENDENT OR COMPUTER CONTROL, FIVE LANGUAGES SWITCH DISPLAY, EQUIPPED WITH MULTIPLE COMMUNICATION INTERFACES (USB, ETHERNET), WIFI CAN ALSO BE ENABLED, ONE COMPUTERCAN CONTROL FOUR INSTRUMENTS AT THE SAME TIME.PARAMETER:CONCENTRATION RANGE: 0 ~ 100,000 / CM3GRAIN DIAMETER: 0.02 ~ 1.0^MFLOW: SAMPLING FLOW: 100CM3 / MINTOTAL FLOW: 700CM3 / MINCLOSENESS COEFFICIENT TEST: DIRECT TEST (COUT/ CIN)LIQUOR: 99.5% + ISOPROPANOL (ANALYTICAL GRADE)DISPLAY: 7INCH TRUE COLOR TOUCH SCREENCOMMUNICATION INTERFACE: USB X 3 (HOST X 2,DEVICE X 1) ETHERNET INTERFACE X1CONNECTION PORT: ENVIRONMENT PORT, SAMPLING PORTWIFI: EQUIPPEDLANGUAGES: ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESEFLOW CONTROL: SENSOR CONTROLPC CONTROLLABLE OPERATION: ONE COMPUTER CAN CONTROL 4 INSTRUMENTS AT THE SAME TIMEDATA OUTPUT FORMAT: MICROSOFT EXCELWORKING TEMPERATURE: 15 ~ 35 °CPOWER SOURCE: AC 110 —240V 50 / 60HZAPPEARANCE SIZE: 208 X 117 X 262MMWEIGHT: 2.1KGACCESSORIES: ALCOHOL REAGENT BOTTLE, PROTECTIVE CAP, REAGENT STICK, ZERO-COUNT FILTER, STRAINER, SAMPLING TUBE, INSTRUCTION MANUAL, AC ADAPTER, TOUCH SCREEN PEN, OPTIONAL COMPUTER.OPTIONAL: TEST KIT FOR TIGHTNESS COEFFICIENTIN ORDER TO PREVENT INFECTION AT THE MEDICAL SITE AND DURING LABOR WORK, WORKERS MUST BE PROTECTED FROM INHALABLE HAZARDOUS SUBSTANCES IN THE WORKPLACE, AND RESPIRATORS SUCH AS MASKS MUST BE WORN DURING WORK.SELECT A RESPIRATOR, SUCH AS A MASK, BASED ON YOUR FACIAL FEATURES, AND EVALUATE THE TIGHTNESS BETWEEN THE RESPIRATOR, SUCH AS A MASK AND THE FACE, TO CHECK WHETHER THERE ARE GAPS OR LEAKS THAT PUT WORKERS AT RISK. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTIVE PERFORMANCE. SECURITY EXPERTS WILL ALSO DEVELOP PROTECTION SCHEMES AND STANDARD REGULATIONS BASED ON THE RESULTS OF THE TIGHTNESS TEST. WIDELY USED IN HOSPITALS, MANUFACTURING PLANTS, PRODUCTION SITES, FIREFIGHTING WORKPLACES AND OTHER OFFICIAL TESTING AGENCIES.MASK TIGHTNESS TESTER FEATURES:• QUANTITATIVE TIGHTNESS TEST FOR RESPIRATORS SUCH AS MASKS (QNFT)• APPLICABLE TO 100/99 / P3 / HEPA SERIES MASK DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING N95 / N90 / KN95 AND OTHER DISPOSABLE DUST MASKS)• ADHESION TEST OF HALF MASK AND FULL FACE MASK• GAS MASK TIGHTNESS TEST• PAPR MASK TIGHTNESS TEST• SCBA RESPIRATOR MASK TIGHTNESS TEST• 7INCH TRUE COLOR TOUCH SCREEN• INDEPENDENT OR COMPUTER CONTROLLED• USING CNC TECHNOLOGY• ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESE LANGUAGE SWITCHING DISPLAY• COMPLIES WITH US OSHA STANDARDS, CANADIAN STANDARDS ASSOCIATION (CSA) GUIDELINES, INCLUDING N95• EQUIPPED WITH A VARIETY OF COMMUNICATION INTERFACES (USB, ETHERNET), AND CAN ALSO ENABLE WIFI• ONE COMPUTER CAN CONTROL FOUR INSTRUMENTS AT THE SAME TIMEQUANTITY: 1 - J-2813 HANDHELD AIRBORNE PARTICLE COUNTER, MODEL 3000
FEATURES
0.3 - 25 µm SENSITIVITY
FLOW RATE: 1.0 CFM (28.3 LPM)
UP TO 8 CHANNELS OF SIMULTANEOUS COUNT DATA
21 CFR PART 11 COMPLIANT SECURE USB FLASH TRANSFER
EXTREME LIFE LASER DIODE TECHNOLOGY >20-YEAR MTTF
5.7 INCH COLOR TOUCH SCREEN DISPLAY
THERMAL PRINTER
STAINLESS STEEL CONSTRUCTION
ETHERNET/RS485/MODBUS, 4x 4-20mA ANALOG INPUTS
3,000 RECORD DATA STORAGE
50-RECORD CONFIGURABLE RECIPE DATABASE
REPORT WIZARD: FS-209E, ISO-14644-1 & EU GMP ANNEX 1
2 YEAR WARRANTYSTANDARD 6 CHANNELS: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm , 0.3, 0.5, 1.0, 5.0, 10.0, 25.0 µm
STANDARD 8 CHANNELS: 0.3,0.5,0.7,1.0,3.0,5.0,7.0,10.0 µm
OPTIONAL 8 CHANNELS: OPTIONAL BETWEEN 0.3 AND 25.0 µm
COUNTING EFFICIENCY: 50%@0.3µm; 100% FOR PARTICLES > 0.45 µm (PER ISO 21501-4)
CONCETRATION LIMITS: 1,000,000 PARTICLES/FT3, (35,300,000/M3) @ 10% COINCIDENCE LOSS SUITABLE FOR ISO CLASSES 1-8 CLEANROOMS
DIMENSIONS: 9.5”(L) x 8.0”(W) x 10.2”(H) (24.13 x 20.32 x 25.9 cm)
WEIGHT: WITH BATTERY: 13.95 LBS (6.33 KG), WITHOUT BATTERY 12.35 LBS (5.6 KG)INCLUDES
OPERATING MANUAL WITH CD, LMS EXPRESS TRANSFER SOFTWARE DOWNLOAD INSTRUCTIONS, ISOKINETIC SAMPLE PROBE, TRIPOD, TUBING, PURGE FILTER, POWER CABLES, SPARE FUSE, PRINTER, PRINTER PAPERLEAD TIME: 1 TO 2 WEEKS FROM RECEIPT OF ORDER
QUANTITY: 1
Learn More - P-8697 PP MELT BLOWN NONWOVEN FABRIC FOR MASKS MELTBLOWN, MELT-BLOWN, MIDDLE LAYER, MASK FILTER
ENVIRONMENT: 380V/50Hz
Learn More
RAW MATERIAL: MFI=1000 TO 1600
PRODUCT SPECIFICATION: WIDTH: 1600mm (AS PER 50G/M2)
WEIGHT RANGE: 10 TO 80G/M2
PRODUCT CAPACITY: 80KG/H (AS PER WEIGHT RANGE ≥80G/M2, WIDTH: 1600mm)
MAX MECHANICAL SPEED: 0 TO 50M/MIN
FIBER FINENESS: 2 TO 5μM
TOTAL INSTALLED POWER: 400 KW
OUTPUT FOR 25G/M2: ABOUT 1 TON
DIMENSION: 16MX8MX6M
QUANTITY: 1 - T-6577 PROTECTION SUIT WITH SHOE COVER
PROTECTION SUIT WITH SHOE COVER
Learn More
HOODED DESIGN
HOODED HEAD DESIGN
ELASTIC DESIGN AT THE MOUTH
CAN ISOLATE DUST AND MICROORGANISMS
SEALED AND PROTECTED BY RUBBER STRIPS
THE WHOLE PIECE DESIGN
EASY TO PUT ON AND TAKE OFF
ELASTIC CUFFS, FLEXIBLE, EFFECTIVE BARRIER, EASIER TO USE
ELASTIC WAISTBAND SLIM ELASTIC WAISTBAND DESIGN, CLOSE THE WAIST, WORK MORE FREELY
CERTIFICATE: CE
MOQ: 1000PCS
MODEL: CONJOINED SPECS: S/160, M/165, L/170, XL/175, XXL/180 ALL SIZES ARE AVAILABLE, PRICES ARE SAME
TYPE:
NON-STERILE: 9.5KG/BOX, 30PCS/BOX, 560 X 430 X 360mm
STERILIZED FOR HOSPITAL: 13KG/BOX, 40PCS/BOX, 600 X 400 X 450mm
PRODUCT DESCRIPTION: CLOTHING MADE FROM FABRICS WITH ISOLATION FUNCTION SUCH AS VIRUS-CONTAINING AEROSOLS AND VIRUS-CONTAINING LIQUIDS. WHEN TAKEN OFF, THE OUTER SURFACE OF THE PROTECTIVE CLOTHING SHOULD NOT COME IN CONTACT WITH THE HUMAN BODY. THIS PRODUCT DOES NOT HAVE FLAME RETARDANT PROPERTIES.
INTENDED USE: OCCUPATIONAL PROTECTIVE CLOTHING FOR MEDICAL PERSONNEL IN MEDICAL INSTITUTIONS TO PREVENT THE TRANSMISSION OF VIRUSES FROM PATIENTS TO THE MEDICAL PERSONNEL WITH AIR OR LIQUID. - T-6575 NON-INVASIVE VENTILATOR
NON-INVASIVE VENTILATOR
Learn More
CERTIFICATE: CE
MEDICAL VENTILATOR
TECHNICAL PARAMETERS OF DOUBLE LEVEL VENTILATOR
VENTILATOR TYPE: ELECTRIC CONTROL
SCOPE OF APPLICATION: TREATMENT AND TITRATION OF SLEEP APNEA HYPOPNEA SYNDROME, SEVERE SNORING, AND RESPIRATORY INSUFFICIENCY.
DISPLAY INTERFACE: 3.5-INCH LED SCREEN, CHINESE OPERATING SYSTEM
*VENTILATION MODE: CPAP, S, S/T, T
PRESSURE RANGE:
PRESSURE RANGE: 4-30CMH2O (±0.5CMH2O)
PRESSURE ACCURACY: + 0.5CMH2O
PARAMETER SETTING:
DELAYED BOOST: 0-60MIN, SET THE DIVISION INTERVAL 5MIN
INITIAL PRESSURE: 4CMH2O TREATMENT PRESSURE / RESPIRATORY PRESSURE SETTING
THERAPEUTIC PRESSURE: 4-20CMH2O (IN CPAP MODE)
TARGET TIDAL VOLUME: 150ML - 1500ML, ON/ OFF
MAXIMUM SUCTION PRESSURE: 4-30CMH2O, (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
MINIMUM SUCTION PRESSURE: 4-30CMH2O (NOT HIGHER THAN THE SUCTION PRESSURE), (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
INSPIRATORY PHASE PRESSURE: 4-30CMH2O
EXPIRATORY PRESSURE: 4-30CMH2O
EXPIRATORY DECOMPRESSION: PATIENT, OFF, 1-3, THREE ADJUSTABLE
MANUAL VOLTAGE REGULATION: 0-2 GEAR, 0-2CMH2O (ONLY AVAILABLE IN CPAP MODE)
INSPIRATORY SENSITIVITY: 1-8 STALLS
EXPIRATORY SENSITIVITY: 1-8 STALLS
RESPIRATORY FREQUENCY: 3-40 TIMES / MIN
INSPIRATORY TIME: 0.3-3.0S
BACKUP RATE: ON / OFF, DEFAULT 10
PRESSURE RISE TIME: 1-4 STALLS
HUMIDIFIER: 1-5 ADJUSTABLE IN 5 GEARS
*TITRATION FUNCTION: SUPPORT MANUAL AND AUTOMATIC PRESSURE TITRATION, BUILT-IN REMOTE WIRELESS COMMUNICATION MODULE, COMPLETE THE RANDOM SWITCHING OF SINGLE AND DOUBLE LEVEL MODES IN THE TITRATION PROCESS, AND CONTROL MORE THAN 11 VENTILATOR PARAMETERS AT THE SAME TIME.
AUXILIARY FUNCTION: AUTOMATIC AIR LEAKAGE COMPENSATION, AUTOMATIC STARTUP, AUTOMATIC SHUTDOWN, DELAYED SHUTDOWN, SCREEN BACKLIGHT ADJUSTMENT
MONITORING PARAMETERS: PRESSURE, TIDAL VOLUME, RESPIRATORY RATE, MINUTE VENTILATION VOLUME, AIR LEAKAGE VOLUME, INSPIRATORY TIME, BLOOD OXYGEN SATURATION
WAVY CURVE: PRESSURE TIME WAVEFORM, FLOW RATE TIME WAVEFORM
ALARM PROMPT: PIPELINE AND MASK FALLING OFF, AIR LEAKAGE PROMPT, POWER INTERRUPTION, TREATMENT MACHINE FAILURE, HUMIDIFIER FAILURE, LOW VOLTAGE, HIGH RESPIRATORY RATE, LOW RESPIRATORY RATE, LOW MINUTE VENTILATION VOLUME, LOW BLOOD OXYGEN, REPLACEMENT OF FILTER COTTON, FULL SD CARD, RE INSERTION OF SD CARD
*DATA MANAGEMENT:
NETWORK DATA: BMC + RESPIRATORY HEALTH MANAGEMENT CLOUD PLATFORM
SD CARD DATA: RESART NPAP DATA ANALYSIS SOFTWARE
PARTS:
SD CARD: STANDARD
SD CARD SLOT: STANDARD
PIPING: 9 22MM, 1.8M LONG
FACE SHIELD: F2 NOSE MASK AS STANDARD
NOISE: LESS THAN 30DB
ENVIRONMENT CONDITION:
TEMPERATURE:
(WHEN USED) 5 -35 C
(DURING TRANSPORTATION AND STORAGE) -20 C -55 C
ATMOSPHERIC PRESSURE:
(WHEN USED) 760-1060HPA
(DURING TRANSPORTATION AND STORAGE) 760-1060HPA
WORKING HOURS: MORE THAN 8 HOURS
POWER SUPPLY REQUIREMENTS:
AC VOLTAGE: 100-240V
FREQUENCY: 50HZ/60HZ
INPUT POWER: LESS THAN 2A
WATERPROOF LEVEL: IP22 - DRIP PROOF EQUIPMENT
INSTRUMENT SIZE: 290mm X 180mm X 134mm
WEIGHT: 1.5KG (EXCLUDING HUMIDIFIER) 2.5KG (INCLUDING HUMIDIFIER)
ITEM 001
QUANTITY: 10 SETS-999 SETS
ITEM 002
QUANTITY: 1,000 SETS-9,999SETS
ITEM 003
QUANTITY: ≥10,000 SETS - J-2786 VERTICAL MODULE FOR TEMPERATURE MEASUREMENT & FACE RECOGNITION
USES ROCKCHIP RK3288 / RK 3399 / QUALCOMM MSM8953 HIGH-PERFORMANCE HARDWARE PLATFORM, EQUIPPED WITH INDUSTRIAL GRADE BINOCULAR CAMERA, LIVE FACIAL RECOGNITION SOFTWARE AND INFRARED THERMAL IMAGING MODULE TO SUPPORT FACE-WITH-MASK INDEITIFICATION.
SUPPORTS EXPANSION OF VARIOUS PERIPHERALS SUCH AS ID CARD READERS, FINGERPRINT READERS, ETC WHICH CAN BE APPLIED TO GATE PASSAGES AND ATTENDANCE SYSTEM TO ACHIEVE SAFE AND EFFICIENT ACCESS CONTROL FOR PERSONNEL
CAN BE USED WITH ACCESS GATES & ATTENDANCE FOR COMMUNITIES, OFFICES, SCHOOLS, HOTELS, PUBLIC VENUES, TRANSPORTATION HUBS AND PUBLIC SERVICE PLACES
FEATURES:
8 INCH IPS FULL-VIEW LCD DISPLAY
INDUSTRIAL APPEARANCE, WATERPROOF AND SUNPROOF DESIGN
STABLE AND RELIABLE
SUPPORTS A DATABASE OF 30,000 FACES
THE 1:1 COMPARISON RECOGNITION RATE IS MORE THAN 99.7%
THE 1:N COMPARISON RECOGNITION RATE IS MORE THAN 96.7% @ 0.1% MISRECOGNITION RATE
LIVE DETECTION ACCURACY RATE: 98.3% @ 1% MISRECOGNITION RATE
FACE RECOGNITION PASS SPEED IS LESS THAN 1 SECOND
SUPPORTS ACCURATE FACE RECOGNITION AND COMPARISON WHILE WEARING A MASK
USES INDUSTRIAL GRADE BINOCULAR WIDE DYNAMIC CAMERA, NIGHT INFRARED AND LED DUAL PHOTO FLOOD LAMP
ROCKCHIP RK3288 QUAD-CORE PROCESSOR, ROCKCHIP RK3399 SIX-CORE PROCESSOR, AND QUALCOMM MSM8953 OCTA-CORE PROCESSOR
SUPPORTS HUMAN BODY TEMPERATURE DETECTION AND DISPLAY (BEST TEMPERATURE DETECTION DISTANCE IS 0.5 METERS, MAXIMUM IS 1 METER), MEASUREMENT ERROR +/- 0.5 °C
TEMPERATURE CAN BE READ IN ONLY A FEW SECONDS AND THE DEVICE AUTOMATICALLY SOUNDS AN ALARM FOR ABNORMALITIES
ATTENDANCE TEMPERATURE MEASUREMENT DATA EXPORTED IN REAL TIME
VARIOUS PERIPHERALS AVAILABLE FOR ID CARD READING, FINGERPRINT READING, IC CARD READING, 2-DIMENSIONAL CODE READING, ETC.
WITH COMPLETE DOCUMENTATION AND SUPPORT FOR SECONDARY DEVELOPMENT
SUPPORTS SYSTEM LEVEL, APP OFFLINE LEVEL, APP AND BACKGROUND NETWORK LEVEL MULTIPLE API DOCKINGCAMERA
RESOLUTION 2 MILLION PIXELS
TYPE BINOCULAR WIDE DYNAMIC CAMERA
APERTURE F2.4
FOCUSING DISTANCE 50-150CM
WHITE BALANCE AUTO
PHOTO FLOOD LIGHT LED AND IR DUAL PHOTO FLOOD LIGHTSCREEN
SIZE 8.0 INCH IPS LCD SCREEN
RESOLUTION 800×1280
TOUCH NOT SUPPORTED (OPTIONAL SUPPORT)PROCESSOR
CPU RK3288 QUAD-CORE (OPTIONAL RK3399 SIX-CORE, MSM8953
EIGHT-CORE)
STORAGE EMMC 8GINTERFACE
NETWORK MODULE ETHERNET AND WIRELESS (WIFI)
AUDIO 2.5W / 4R SPEAKERS
USB 1 USB OTG, 1 USB HOST STANDARD A PORT
SERIAL COMMUNICATION 1 RS232 SERIAL PORT
RELAY OUTPUT 1 DOOR OPEN SIGNAL OUTPUT
WIEGAND ONE WIEGAND 26/34 OUTPUT, ONE WIEGAND 26/34 INPUT
UPGRADE BUTTON SUPPORT UBOOT UPGRADE BUTTON
WIRED NETWORK 1 RJ45 ETHERNET SOCKETFUNCTION
CREDIT CARD READER NONE (OPTIONAL IC CARD READER, ID CARD, ID CARD)
FACE DETECTION SUPPORTS DETECTION AND TRACKING OF MULTIPLE PEOPLE AT THE SAME
TIME
FACE LIBRARY UP TO 30,000
1: N FACE RECOGNITION SUPPORT
1: 1 FACE COMPARISON SUPPORT
STRANGER DETECTION SUPPORT
IDENTIFY DISTANCE
CONFIGURATION
SUPPORT
UI INTERFACE CONFIGURATION SUPPORT
UPGRADE REMOTELY SUPPORT
INTERFACE INTERFACES INCLUDE DEVICE MANAGEMENT, PERSONNEL / PHOTO
MANAGEMENT, RECORD QUERY, ETC.
DEPLOYMENT METHOD SUPPORT PUBLIC CLOUD DEPLOYMENT, PRIVATIZED DEPLOYMENT, LAN
USE, STAND-ALONE USEINFRARED THERMAL IMAGING MODULE
TEMPERATURE DETECTION SUPPORT
TEMPERATURE DETECTION 1 METER (OPTIMAL DISTANCE 0.5 METER)
DISTANCE
TEMPERATURE
MEASUREMENT ACCURACY
≤ ±0.5℃
TEMPERATURE
MEASUREMENT RANGE
10℃~42℃
THERMAL FIELD OF VIEW 32 X 32℃
VISITORS' TEMPERATURE IS
NORMAL AND RELEASED
DIRECTLY
SUPPORT
ABNORMAL TEMPERATURE
ALARM
SUPPORT (TEMPERATURE ALARM VALUE CAN BE SET)GENERAL PARAMETERS
POWER DC12V(±10%)
OPERATING TEMPERATURE 0℃~60℃
STORAGE TEMPERATURE -20℃~60℃
POWER CONSUMPTION 13.5W(MAX)
INSTALLATION METHOD GATE BRACKET INSTALLATION
SIZE : STANDARD:274.24*128*21.48(MM); IC CARD / ID CARD:296.18*132.88*25(MM)PACKING LIST
Learn More
MACHINE * 1, POWER ADAPTER * 1, MANUAL * 1, CERTIFICATE OF CONFORMITY * 1 - V-1820 MASK AND RESPIRATOR FIELD TESTER
MAINLY USED FOR VISUAL FIELD TESTING OF MASKS AND RESPIRATORS, WHICH IS USEFUL FOR MASK AND RESPIRATOR MANUFACTURERS, QUALITY SUPERVISORS, SCIENTIFIC RESEARCH, AND FOR TESTING PRIOR TO SELLING MASKS.
FEATURES:
1. THE EQUIPMENT IS COMPOSED OF A SEMI-ARC BOW, RECORDING DEVICE, SEAT FRAME AND TEST HEAD DIE.
2. SEMI-ARC BOW: THE RADIUS IS 300 TO 340 mm
CAN BE ROTATED AROUND THE HORIZONTAL RADIUS PLANE PASSING THROUGH THE POINT 0°, AND A SCALE EXTENDING TO THE 90° ARC BOW EVERY 5° FROM 0° ON BOTH SIDES, EQUIPPED WITH SLIDING WHITE VISUAL STANDARD.
3. RECORDING DEVICE: THE RECORDING NEEDLE IS CONNECTED WITH THE VISUAL STANDARD THROUGH COMPONENTS SUCH AS AXLE WHEEL, AND THE DIRECTION AND ANGLE OF THE VISUAL STANDARD ARE RECORDED ON THE VISUAL FIELD DRAWING CORRESPONDINGLY.
4. SEAT FRAME: USED TO SUPPORT SEMI-CIRCULAR ARC BOW AND FIXED RECORDING DEVICE.
5. TEST THE HEAD MOLD: A STANDARD HEAD MOLD, THE TWO EYE HOLES OF THE HEAD MOLD ARE EQUIPPED WITH SMALL LIGHT BULBS, THE POSITION OF THE BULB AND THE POSITION OF THE HEAD MOLD ARE ACCORDING TO THE REQUIREMENTS OF GB 2890. THE TEST HEAD DIE MUST BE INSTALLED ON THE WORKBENCH IN SUCH A WAY THAT THE LEFT AND RIGHT EYES ARE PLACED AT THE CENTER OF THE SEMICIRCULAR ARCH AND THE "0" POINT IS DIRECTLY SEEN.MAIN INDICATORS
Learn More
1. SEMI-CIRCULAR ARC RADIUS: 335mm.
2. LEFT AND RIGHT FIELD OF VIEW: ≤120°.
3. BULB DISTANCE: THE VERTEX OF THE BULB IS CONNECTED AFTER THE TWO EYE POINTS (7±0.5).
APPLICABLE STANDARDS: GB/T 32610-2016, GB 2626-2019, GB2890-2009