Search results for: 'GAS G'
- L-4786 WAUKESHA VHP7044GSI GENERATORS, 1200 RPM, 50 & 60 Hz
L-4786 WAUKESHA VHP7044GSI GENERATORS, 1200 RPM, 50 & 60 Hz
CAN OPERATE AT 1150 KW, 1200 RPM, 60 Hz, 600/480 VAC
Learn More
OR
AT 1050 KW, 1000 RPM, 50 Hz, 400 VAC
WEATHER ENCLOSURE W/SKID
ENGINE DRIVEN RADIATOR ASSEMBLY
ENGINE CONTROLS & INTERFACE: WAUKESHA ENGINE ECU & AUXILIARY I/O BOX
KATO ALTERNATOR, 1200 KW / 1500 KVA, 6P6-3300, 6– POLES, 2 BEARING, 1200 RPM, 80 DEG C TEMP.
RISE (40 DEG. AMBIENT), IP-23 ENCLOSURE, PMG, CLASS 'H', 600/480 VOLT AC DUAL VOLTAGE, 3 PH,60HZ, 0.8 PF. FOUR (4) UNITS WITH
RENOLD COUPLING - 4 UNITS WITH MARATHON ALTERNATOR 480 VAC
ENGINE CONTROLS AND INTERFACE – ECU AND AUXILIARY I/O BOX
50 GALLON OIL MAKE-UP SYSTEM WITH LEVEL INDICATION - R-1390 OSTHOFF SINGEING/CORINO ENTRY & EXIT/PAREX & DESIZING RANGE, WORKING WIDTH 2000mm, YEAR 1995 - RECONDITIONED 2015
REFERENCE NUMBER: R-1390
OSTHOFF SINGEING/CORINO ENTRY & EXIT/PAREX & DESIZING RANGE, WORKING WIDTH 2000mm, YEAR 1995 - RECONDITIONED 2015
DETAILS:
BRAND:OSTHOFF
WORKING WIDTH: 2000mm
YEAR: 1995
FULLY RECONDITIONED IN YEAR: 2015COMPRISING OF:
ITEM 001
CORINO DE- BATCH- J BOX & BRUSH
WORKING WIDTH: 2000mm
QUANTITY: 1ITEM 002
OSTHOFF SINGEING MACHINE
TYPE: PK 90
MAXIMUM FABRIC WIDTH: 2000mm
MAXIMUM FLAME WIDTH: 2200mm
QUANTITY: 1ITEM 003
GAS BURNERS WITH AUTO IGNITION ELECTRODES
WORKING WIDTH: 2000mm
QUANTITY: 2ITEM 004
PAREX DESIZING WITH 2 BOWL PADDER
QUANTITY: 1ITEM 005
Learn More
ONE PAREX OPEN WIDTH DESIZING - WASHING TANK
WORKING WIDTH: 2000mm
QUANTITY: 1 - M-6053 SPUNBOND PRODUCTION LINE, WORKING WIDTH 4040mm TO 4500mm
M-6053 SPUNBOND PRODUCTION LINE, WORKING WIDTH 4040mm TO 4500mm
OFFER 001
SPUNBOND PRODUCTION LINE
WORKING WIDTH: 4040mm
WEIGHT: 130 TO 250 G/M2OFFER 002
POLYMER CLEANING GROUPOFFER 003
CRYSTALLIZING GROUPOFFER 004
DRYING GROUPOFFER 005
PNEUMATIC CONVEYING SYSTEMOFFER 006
EXTRUDER HOPPEROFFER 007
EXTRUDEROFFER 008
FILTERING UNITOFFER 009
MELT TRANSFER LINEOFFER 010
SPINNING BEAMOFFER 011
SPINNING PACKSOFFER 012
FILAMENTS QUENCHING SYSTEMOFFER 013
FILAMENTS DRAWING AND DISTRIBUTION SYSTEMOFFER 014
WEB FORMING CONVEYOR BELTOFFER 015
CREEL FOR APPLICATION OF REINFORCING FILAMENTSOFFER 016
PRE-NEEDLING MACHINEOFFER 017
NEEDLING MACHINEOFFER 018
THERMOSETTING UNITOFFER 019
OUTLET CALENDEROFFER 020
FOULARDOFFER 021
BINDER PREPARATION SYSTEMOFFER 022
DRYEROFFER 023
OUTLET CALENDEROFFER 024
AUTOMATIC WINDEROFFER 025
AIR COMPRESSORS (FOR FILAMENTS STRETCHING EJECTORS)OFFER 026
DIATHERMIC OIL HEATING SYSTEMOFFER 027
CHILLED WATER CIRCULATION AND GENERATION SYSTEMOFFER 028
EQUIPMENT FOR CLEANING CYCLE, SPECIAL TOOLSOFFER 029
FIBRE DUST RECOVERY SYSTEMOFFER 030
EDGES RECOVERY SYSTEMOFFER 031
SPINNING SECTION STEEL STRUCTUREOFFER 032
DISTRIBUTION ELECTRIC CABINETSOFFER 033
PROCESS ELECTRIC SYSTEM OF EXISTING MACHINES ACCORDING TO THE ACTUAL LAYOUTOFFER 034
CABLES AND CABLING MATERIALSQUANTITY: 1 LINE
Learn More - KUSTERS CONTINUOUS WASHING MACHINE, WORKING WIDTH 3400mm, YEAR 1996REFERENCE NUMBER: T-6916 KUSTERS CONTINUOUS WASHING MACHINE, WORKING WIDTH 3400mm, YEAR 1996 KUSTERS CONTINUOUS WASHING MACHINE FOR TUULE CURTAIN WASHING- GUIPURE TREATMENT WORKING WIDTH 3400mm ROLLER WIDTH 3600mm YEAR 1996 2 WASHING TANKS 2 KUSTERS SQUEEZING PADDER (ONE WITH S-ROLL FEATURE) 1 CHAMBER DRYING GAS HEATED WELL MAINTAINED WITH ORIGINAL SPARE PARTS SITUATION: INSTALLED AND RUNNING QUANTITY: 1 Learn More
- BABCOCK STENTER, WORKING WIDTH 3400mm, YEAR 1996REFERENCE NUMBER: T-6915 BABCOCK STENTER, WORKING WIDTH 3400mm, YEAR 1996 BABCOCK STENTER WORKING WIDTH 3400mm ROLLER WIDTH 3600mm YEAR 1996 6 CHAMBERS HORIZONTAL CHAIN PINS AND CLIP MAHLO WEFT STRAIGHTENER KUSTERS PADDER (S-ROLL & DYEING FEATURE AVAILABLE) DOCK ROLLING PLAITER PLC SIEMENS INVERTOR GAS HEATED WELL MAINTAINED SITUATION: INSTALLED AND RUNNING QUANTITY: 1 Learn More
- P-8708 ISOLATION MEDICAL GOWN
REFERENCE NUMBER: P-8708
ISOLATION MEDICAL GOWN
35G SMS NON WOVEN+PE FILM
JUST CLOTH
PACKAGE: 1PC/BAG
CTN: 50PCS
CTNSIZE: 60X40X48mm
SUIT IS NOT STERILIZED BY ETHYLENE OXIDE GAS
CAN BE USE FOR NORMAL CLINIC AND TEST IN HOSPITAL.
QUANTITY: 12,500PCS
Learn More - P-8709 PROTECTIVE MEDICAL SUIT
REFERENCE NUMBER: P-8709
PROTECTIVE MEDICAL SUIT
NON WOVEN MATERIAL (PP NON WOVEN+FILM)
INCLUDE THE CLOTH AND BOOTS
CLOTH WITH SHOE COVER TOGETHER
PACKAGE: 1PC/BAG
CTN: 25PCS
CTN SIZE: 76X30X50mm
SUIT IS NOT STERILIZED BY ETHYLENE OXIDE GAS
CAN BE USED FOR NORMAL CLINIC AND TEST IN HOSPITAL.
QUANTITY: 10,000PCS
Learn More - T-6582 MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)
REFERENCE NUMBER: T-6582
MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)
MEDICAL PROTECTIVE SUIT IMPERMEABLE STERILIZED (USED IN INFECTIOUS ISOLATION WARD)
1.NP3030: MEDICAL DISPOSABLE PROTECTIVE CLOTHING,STRONG RESISTANT
2.FABRIC: SF 66 G, COLOR: WHITE RUBBER:CAP/FOOT/CUFF/WAIST FRONT FLAP: DOUBLE-SIDED TAPE, TAPE:BLUE TAPE, ETHYLENE OXIDE DISINFECTION, STERILE
3.PACKAGED: 1PC/BAG, 32PCS/CARTON,10KG/CARTONCARTON SIZE: 470 X300 X420mm/CTN
4.NOTE: CLASS II MEDICAL TREATMENT, SCOPE OF USE: MEDICALPERSONNEL CONTACT WITH POTENTIALLY INFECTIOUS PATIENTSBLOOD, BODY FLUIDS, SECRETIONS, PARTICLES IN THE AIR TOPROVIDE BARRIER, PROTECTION. THIS PRODUCT IS USED FORISOLATION OF OBSERVATION WARD (ROOM), ISOLATION WARD(ROOM), ETC. IT IS STRICTLY PROHIBITED TO USE IN THE ISOLATIONCRITICAL CARE WARD (ROOM) AND OTHER PLACES WITH STRICTCONTROL OF MICROBIAL INDICATORS1PC/BAG, 32PCS/CARTON.
WEIGHT AND DIMENSIONS OF CARTONS: 10KG/CARTON
CARTONS IN A 20 FOOT CONTAINER: 370 BOXESSTERILIZED BY ETHYLENE OXIDE GAS
EACH PIECE IS INDIVIDUALLY VACUUM PACKED
1PER PLASTIC POUCH
QUANTITY: 10,000
Learn More - T-6545 MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTER
REFERENCE NUMBER: T-6545
MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTER
PRODUCT INTRODUCTION:
MASK BACTERIA FILTRATION EFFICIENCY KEY PERFORMANCE INDICATORS (BFE) DETECTOR TESTER NOT ONLY CONFORMS TO THE REQUIREMENTS OF MEDICAL SURGICAL MASKS TECHNOLOGY YY0469-2011 APPENDIX B IN THE TEST METHOD FOR FILTER EFFICIENCY (BFE) BACTERIA FIRST B. 1.1.1 TEST INSTRUMENT, BUT ALSO CONFORMS TO THE AMERICAN SOCIETY FOR TESTING MATERIAL ASTMF2100, ASTMF2101, THE REQUIREMENTS OF THE EUROPEAN EN14683 STANDARDS, INNOVATIVE IMPROVEMENTS WERE MADE ON THE BASIS OF THIS, WITH DOUBLE PNEUMATIC CONTRAST SAMPLING METHOD AT THE SAME TIME, IMPROVE THE PRECISION OF SAMPLING,IT IS SUITABLE FOR MEASURING AND TESTING DEPARTMENTS, SCIENTIFIC RESEARCH INSTITUTES, MASK MANUFACTURERS AND OTHER RELEVANT DEPARTMENTS TO TEST THE PERFORMANCE OF MASK BACTERIAL FILTRATION EFFICIENCY.
EXECUTION STANDARD:
Q/0212 ZRB003-2015 MEDICAL SURGICAL MASK
BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR RELATED INTELLECTUAL PROPERTY:
NO.: ZL200820224142.6 ELECTRIC FLOW CONTROL VALVE
NO.: ZL200820224143.0 GAS CAPACITY
NO.: ZL200920308391.8 AIR FILTRATIONMATERIAL FILTRATION EFFICIENCY DETECTOR
PRODUCT FEATURES:
NEGATIVE PRESSURE TEST SYSTEM TO ENSURE THE SAFETY OF OPERATORS;
BUILT -IN PERISTALTIC PUMP IN NEGATIVE PRESSURE CABINET, A, B TWO -WAY, SIX ANDERSEN; THE PERISTALTIC PUMP FLOW CAN BE SET;
THE FLOW RATE OF NIGHT SPRAY CAN BE SET AND THE ATOMIZATION EFFECT IS GOOD.
EMBEDDED HIGH SPEED INDUSTRIAL MICROCOMPUTER CONTROL; 10.4 INCHES INDUSTRIAL HIGH BRIGHTNESS COLOR TOUCH SCREEN;
USB INTERFACE, SUPPORT U DISK DATA STORAGE;
CABINET BUILT-IN HIGH BRIGHTNESS LIGHTS; BUILT-IN LEAKAGE PROTECTION SWITCH TO PROTECT THE SAFETY OF OPERATORS;
THE INNER LAYER OF THE CABINET IS MADE OF STAINLESS STEEL, THE OUTER LAYER IS SPRAYED WITH PLASTIC AND COLD-ROLLED, AND THE INNER AND OUTER LAYERS ARE INSULATED AND FLAME RETARDANT.
THE FRONT SWITCH TYPE GLASS DOOR IS CONVENIENT FOR THE EXPERIMENTER TO OBSERVE AND OPERATE.
DETACHABLE BRACKET, ADJUSTABLE BRACKET HEIGHT; SUPPORTING AND MOVING DUAL PURPOSE CASTERS.
QUANTITY: 1
Learn More - T-6549 CONSTANT TEMPERATURE AND HUMIDITY CHAMBER -FABRIC WATER VAPOR TRANSMISSION RATE
REFERENCE NUMBER: T-6549
CONSTANT TEMPERATURE AND HUMIDITY CHAMBER -FABRIC WATER VAPOR TRANSMISSION RATE
TESTING METER (WITH MOISTURE PERMEABLE CUP)
TECHNICAL DESCRIPTION OF THE INSTRUMENT:
IT IS MAINLY USED TO MEASURE THE MOISTURE PERMEABILITY OF ALL KINDS OF FABRICS, INCLUDING PERMEABLE COATED FABRICS. STRUCTURE PRINCIPLE: ADOPT COMPUTER CONTROL, CREATING A CONSTANT TEMPERATURE, AND HUMIDITY TEST ENVIRONMENT, TEST ENVIRONMENT IN THE CONSTANT TEMPERATURE, AND HUMIDITY, MOISTURE VAPOR TRANSMISSION CUP, PLACED 6 SAMPLE INTO THE GLASS AND THE RUBBER GASKET SEAL, THE CONTAINING HYGROSCOPIC AGENT OR WATER SEAL IS SPECIFIED BY THE WET CUP PLACED IN THE FABRIC SAMPLE TEMPERATURE AND HUMIDITY OF THE ENVIRONMENT, THE SEAL MOISTURE VAPOR TRANSMISSION CUP ACCORDING TO A CERTAIN TIME (INCLUDING SAMPLE AND HYGROSCOPIC AGENT OR WATER) TO CALCULATE THE MOISTURE TRANSMISSION QUALITY CHANGE.
TESTING STANDARD:
GB19082-2009 MEDICAL PRIMARY PROTECTIVE CLOTHING
TECHNICAL REQUIREMENTS GUIDELINES FOR THE SELECTION OF YY-T1498-2016 MEDICAL PROTECTIVE CLOTHING
GB/T12704.1 DETERMINATION OF MOISTURE PERMEABILITY OF FABRICS --HYGROSCOPIC METHOD
DETAILED TECHNICAL SPECIFICATIONS AND CONFIGURATION:
TECHNICAL INDICATORS:
1. TEMPERATURE CONTROL RANGE: -40°C ~ 150°C;RESOLUTION; 0.1 °C
2. HUMIDITY CONTROL RANGE: 50%RH ~ 95% RH±5%
3. SPEED RANGE: 2mm ~ 60mm/MIN
4. CONTROL PRECISION: TEMPERATURE <0.1°C; HUMIDITY + / -1% RH OR LESS
5. CYCLIC WIND SPEED: 0.02 ~ 0.5M/S, 0.3 ~ 0.5M/S
6. TIME CONTROL: 1 ~ 9999H
7. MOISTURE PERMEABLE AREA: 2827 mm 2 (DIAMETER IS 60 mm --NATIONAL STANDARD)
8. QUANTITY OF PERMEABLE CUPS: 6 GB;
9. DRYING BOX CONTROL TEMPERATURE: ROOM TEMPERATURE ~ 199 °C
10. TEST TIME: 1 ~ 999H
11. DRYING BOX STUDIO SIZE: 490 X 400 X 215mm
INSTRUMENT CONFIGURATION:
1. ONE MAIN MACHINE
QUANTITY: 1
Learn More