J-2811 AIRBORNE PARTICLE COUNTERAIRBORNE PARTICLE COUNTER
PORTABLE PARTICLE COUNTER WITH 0.10 MICRON SENSITITIVITY AND 1.0 CFM (28.3 LPM) FLOW RATE USING LONG LIFE LASER DIODE TECHNOLOGY.
DESIGNED TO OPERATE IN ISO CLASS 1 TO CLASS 7 CLEANROOMS WITHOUT CONCERNS OF IT DEGRADING ITS ENVIRONMENT OR EXCEEDING CONCENTRATION LIMITS
USES AN OPTICS AND PHOTODIODE SYSTEM DESIGNED TO REDUCE OR ELIMINATE THE TEMPERATURE ISSUES ASSOCIATED WITH HIGH POWER LASER DIODE SENSORS
WITH THERMALLY CONTROLLED EXHAUST SYSTEM AND HEPA FILTER OPTION TO PREVENT ANY EXTERNAL CONTAMINATIONFEATURES
0.1- 1.0 µm SENSITIVITY
1.0 CFM (28.3 LPM)
UP TO 8 CHANNELS OF SIMULTANEOUS COUNT DATA
21 CFR PART 11 COMPLIANT SECURE USB FLASH TRANSFER
LASER DIODE SENSOR TECHNOLOGY
5.7 INCH COLOR TOUCH SCREEN DISPLAY
THERMAL PRINTER
STAINLESS STEEL CONSTRUCTION
ETHERNET/RS485/MODBUS, 4X 4-20MA ANALOG OUTPUTS
3,000 RECORD DATA STORAGE
50-RECORD CONFIGURABLE RECIPE DATABASE
Report wizard: ISO-14644-1, EU GMP Annex 1, FS-209ESTANDARD CHANNEL SIZES: 0.10, 0.15, 0.2, 0.25, 0.3, 0.5, 0.7, 1.0 µm
INCLUDES
OPERATING MANUAL ON CD; ISOKINETIC SAMPLE PROBE WITH TRIPOD AND TUBING; PURGE FILTER; POWER CABLE AND SPARE FUSE; LMS XCHANGE AND EXPRESS SOFTWARE; PRINTER; PRINTER PAPERQUANTITY: 1
Learn More -
T-6575 NON-INVASIVE VENTILATORNON-INVASIVE VENTILATOR
Learn More
CERTIFICATE: CE
MEDICAL VENTILATOR
TECHNICAL PARAMETERS OF DOUBLE LEVEL VENTILATOR
VENTILATOR TYPE: ELECTRIC CONTROL
SCOPE OF APPLICATION: TREATMENT AND TITRATION OF SLEEP APNEA HYPOPNEA SYNDROME, SEVERE SNORING, AND RESPIRATORY INSUFFICIENCY.
DISPLAY INTERFACE: 3.5-INCH LED SCREEN, CHINESE OPERATING SYSTEM
*VENTILATION MODE: CPAP, S, S/T, T
PRESSURE RANGE:
PRESSURE RANGE: 4-30CMH2O (±0.5CMH2O)
PRESSURE ACCURACY: + 0.5CMH2O
PARAMETER SETTING:
DELAYED BOOST: 0-60MIN, SET THE DIVISION INTERVAL 5MIN
INITIAL PRESSURE: 4CMH2O TREATMENT PRESSURE / RESPIRATORY PRESSURE SETTING
THERAPEUTIC PRESSURE: 4-20CMH2O (IN CPAP MODE)
TARGET TIDAL VOLUME: 150ML - 1500ML, ON/ OFF
MAXIMUM SUCTION PRESSURE: 4-30CMH2O, (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
MINIMUM SUCTION PRESSURE: 4-30CMH2O (NOT HIGHER THAN THE SUCTION PRESSURE), (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
INSPIRATORY PHASE PRESSURE: 4-30CMH2O
EXPIRATORY PRESSURE: 4-30CMH2O
EXPIRATORY DECOMPRESSION: PATIENT, OFF, 1-3, THREE ADJUSTABLE
MANUAL VOLTAGE REGULATION: 0-2 GEAR, 0-2CMH2O (ONLY AVAILABLE IN CPAP MODE)
INSPIRATORY SENSITIVITY: 1-8 STALLS
EXPIRATORY SENSITIVITY: 1-8 STALLS
RESPIRATORY FREQUENCY: 3-40 TIMES / MIN
INSPIRATORY TIME: 0.3-3.0S
BACKUP RATE: ON / OFF, DEFAULT 10
PRESSURE RISE TIME: 1-4 STALLS
HUMIDIFIER: 1-5 ADJUSTABLE IN 5 GEARS
*TITRATION FUNCTION: SUPPORT MANUAL AND AUTOMATIC PRESSURE TITRATION, BUILT-IN REMOTE WIRELESS COMMUNICATION MODULE, COMPLETE THE RANDOM SWITCHING OF SINGLE AND DOUBLE LEVEL MODES IN THE TITRATION PROCESS, AND CONTROL MORE THAN 11 VENTILATOR PARAMETERS AT THE SAME TIME.
AUXILIARY FUNCTION: AUTOMATIC AIR LEAKAGE COMPENSATION, AUTOMATIC STARTUP, AUTOMATIC SHUTDOWN, DELAYED SHUTDOWN, SCREEN BACKLIGHT ADJUSTMENT
MONITORING PARAMETERS: PRESSURE, TIDAL VOLUME, RESPIRATORY RATE, MINUTE VENTILATION VOLUME, AIR LEAKAGE VOLUME, INSPIRATORY TIME, BLOOD OXYGEN SATURATION
WAVY CURVE: PRESSURE TIME WAVEFORM, FLOW RATE TIME WAVEFORM
ALARM PROMPT: PIPELINE AND MASK FALLING OFF, AIR LEAKAGE PROMPT, POWER INTERRUPTION, TREATMENT MACHINE FAILURE, HUMIDIFIER FAILURE, LOW VOLTAGE, HIGH RESPIRATORY RATE, LOW RESPIRATORY RATE, LOW MINUTE VENTILATION VOLUME, LOW BLOOD OXYGEN, REPLACEMENT OF FILTER COTTON, FULL SD CARD, RE INSERTION OF SD CARD
*DATA MANAGEMENT:
NETWORK DATA: BMC + RESPIRATORY HEALTH MANAGEMENT CLOUD PLATFORM
SD CARD DATA: RESART NPAP DATA ANALYSIS SOFTWARE
PARTS:
SD CARD: STANDARD
SD CARD SLOT: STANDARD
PIPING: 9 22MM, 1.8M LONG
FACE SHIELD: F2 NOSE MASK AS STANDARD
NOISE: LESS THAN 30DB
ENVIRONMENT CONDITION:
TEMPERATURE:
(WHEN USED) 5 -35 C
(DURING TRANSPORTATION AND STORAGE) -20 C -55 C
ATMOSPHERIC PRESSURE:
(WHEN USED) 760-1060HPA
(DURING TRANSPORTATION AND STORAGE) 760-1060HPA
WORKING HOURS: MORE THAN 8 HOURS
POWER SUPPLY REQUIREMENTS:
AC VOLTAGE: 100-240V
FREQUENCY: 50HZ/60HZ
INPUT POWER: LESS THAN 2A
WATERPROOF LEVEL: IP22 - DRIP PROOF EQUIPMENT
INSTRUMENT SIZE: 290mm X 180mm X 134mm
WEIGHT: 1.5KG (EXCLUDING HUMIDIFIER) 2.5KG (INCLUDING HUMIDIFIER)
ITEM 001
QUANTITY: 10 SETS-999 SETS
ITEM 002
QUANTITY: 1,000 SETS-9,999SETS
ITEM 003
QUANTITY: ≥10,000 SETS -
J-2792 MEDICAL FACE MASK SYNTHETIC BLOOD PENETRATION TESTERUSED FOR MEASURING THE RESISTANCE OF MEDICAL FACE MASKS TO PENETRATION BY A SPLASH OF SYNTHETIC BLOOD
BLOOD SPRAYING DISTANCE: 300 TO 310mm (APPROXIMATE, ADJUSTABLE)
NEEDLE INNER DIAMETER: 0.84mm
SPRAY SPEED: 4500mm PER SECOND, 5500mm PER SECOND, 6350mm PER SECOND
SIMULATED SYNTHETIC BLOOD PRESSURE: 10.6kPa, 16.0 kPa, 21.3 kPa, (i.e. 80mmHg, 120mmHg, 160mmHg)
SUPPORTS THE SPECIMEN MEDICAL FACE MASK ON THE TESTER’S CLAMPING DEVICE AND SPRAYS A FIXED VOLUME (~2ml) OF SYNTHETIC BLOOD SPLASHED HORIZONTALLY TO HIT THE MASK
TESTER CAN PROVIDE DIFFERENT BLOOD PRESSURES WITH PRECISION CONTROL VALVE TO GENERATE 2ml SYNTHETIC BLOOD WITH SURFACE TENSION OF 0.042 ± 0.002 N/m, WHICH MEETS THE REQUIREMENTS DEFINED IN STANDARDS BELOW:
ISO 22609
ASTM F1862
YY 0469-2011
GB/T 19083-2010LEAD TIME: 5 TO 7 WEEKS FROM RECEIPT OF ORDER
QUANTITY: 1
Learn More -
J-2364 LAROCHE SUPER OLYMPIC TEARING LINES, WW 1500mm, 6 CYLINDERS – NEW CONTROLSMAKE: LAROCHE
MODEL: SUPER OLYMPIC
WIDTH: 1500mm
YEAR: MID 1980’S
6 CYLINDERS EACH LINE
CYLINDER DIAMETER: 1000mm
ALL CYLINDERS ARE DESIGNED FOR PINNED LAGS AND THERE IS LIFE LEFT IN MOST OF THE LAGS SETS.
LAGS: (1) 8mm x 135, (1) 10mm x 160, (1) 12 x 166, (3) 13mm x 174
EACH CYLINDER FED BY A FEED ROLL TO FEED DISH COMBINATION AND THE FIBER IS TRANSFERRED TO THE FOLLOWING CYLINDER VIA A CONDENSING SECTION.
MOTORS: 3 x 150 HP 575 VOLT
TOTAL REQUIRED POWER: 875 AMPS
NEW CONTROLS WITH ABB DRIVES
FEED CHUTES
LUMMUS BALERS
PINNED CYLINDERS
TEMAFA BLENDING BINS
EXIT CONVEYORS
EACH SECTION EQUIPPED WITH ANSUL DRY POWDER FIRE PROTECTION SYSTEM THAT IS ACTIVATED FROM EMBER DETECTED IN THE DUCT REMOVAL PIPING.
LINES INCLUDE ALL NECESSARY FANS, MAGNETS, DUCTING AND WIRINGIN PERFECT WORKING ORDER
QUANTITY: 2 LINES
Learn More -
T-2898 PP STAPLE FIBER PLANT, 6000 MTA, BRAND MOSTLY FLEISSNER , AUTEFA BALE PRESST-2898 PP STAPLE FIBER PLANT, 6000 MTA, BRAND MOSTLY FLEISSNER , AUTEFA BALE PRESS
20 TONS PER DAYPP STAPLE FIBER SYSTEM
Learn More
6000 MTA (LINE-1+LINE-2)
EXTRUTION & SPINNING PACKAGE -
R-7504 LLOVERAS CHOCOLATE MOULDING LINE MOULD SIZES OF 400 X 200 X 30mm HIGHREFERENCE NUMBER: R-7504
Learn More
LLOVERAS CHOCOLATE MOULDING LINE
MANUFACTURED BY LLOVERAS
MODEL SIMA N400/1M
MOULD SIZES OF 400 X 200 X 30mm HIGH
QUANTITY: 1 -
M-7721 PEYER / USTER ALMETER AL-100 (REFURBISHED)REFERENCE NUMBER: M-7721
PEYER / USTER ALMETER AL-100 (REFURBISHED)
MAKE: PEYER / USTER
MODEL: ALMETER AL 100
FULLY REFURBISHED
QUANTITY: 1
Learn More -
M-6238 GRIBETZ DG-900-6 COMPUTERIZED/LOCKSTITCH MULTI NEEDLE QUILTING MACHINE – 128” WIDTH – YEAR 1988REFERENCE NUMBER: M-6238
GRIBETZ DG-900-6 COMPUTERIZED/LOCKSTITCH MULTI NEEDLE QUILTING MACHINE – 128” WIDTH – YEAR 1988
MULTI NEEDLE QUILTING MACHINE
LOCKSTITCH/COMPUTERIZED
MAKE: GRIBETZ
MODEL: DG 900, ULTRA 12
128” WIDTH
YEAR: 1988
QUANTITY: 1
Learn More -
R-6814 LIROPOL TOWEL KNITTING MACHINES, RIUS WARPER, CREELSREFERENCE NUMBER: R-6814
LIROPOL TOWEL KNITTING MACHINES, RIUS WARPER, CREELS
(2) X LIROPOL TOWEL KNITTING MACHINES – RUNNING,
MODEL 114133 – YEAR 1994
MACHINE WIDTH 2500mm
GAUGE 12 (NEEDLES PER INCH)
(1) X RIUS WARPER MODEL A-3 30/30
(1) X CREEL WITH STOP MOTION 260 POSITIONS – FOR COTTON
(1) X CREEL FOR WARPER 260 POSITIONS, FOR POLYESTER YARN, WITH HYDRAULIC TENSION CONTROL
(60) X ALUMINUM WARP BEAMS FOR COTTON 21 x 30
(30) X WARP BEAMS, 21 x 21 FOR POLYESTER
(1) X MOTORIZED PLATFORM FOR RIUS WARPER