- T-6544 SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
REFERENCE NUMBER: T-6544
SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
TECHNICAL INDICATORS:
1. THE PROTRUDING SAMPLE FIXING DEVICE CAN SIMULATE THE ACTUAL USE STATE OF THE MASK, SET ASIDE THE TEST TARGET AREA WITHOUT DESTROYING THE SAMPLE, AND DISTRIBUTE THE SYNTHETIC BLOOD IN THE TARGET AREA OF THE SAMPLE.
2. THE SPECIAL FIXED-PRESSURE INJECTION DEVICE CAN EJECT A CERTAIN VOLUME OF SYNTHETIC BLOOD IN A CONTROLLED TIME.
3. IT CAN FULLY SIMULATE THE INJECTION SPEED CORRESPONDING TO THE AVERAGE BLOOD PRESSURE OF HUMAN BODY OF 10.6KPA, 16KPA AND 21.3KPA.
4. A FIXED TARGET PLATE IS SET TO BLOCK THE HIGH-PRESSURE EDGE PART OF THE INJECTED LIQUID FLOW AND ONLY ALLOW THE STEADY FLOW PART TO BE SPRAYED ON THE SAMPLE, WHICH INCREASES THE ACCURACY AND REPEATABILITY OF THE LIQUID VELOCITY SPRAYED ON THE SAMPLE.
STANDARDS:
MEDICAL RESPIRATOR TECHNICAL REQUIREMENTS, 5.5 SYNTHETIC BLOOD PENETRATION BARRIER PERFORMANCE
YY/T 0691-2008 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK RESISTANCE TO SYNTHETIC BLOOD PENETRABILITY TEST METHOD (FIXED VOLUME, HORIZONTAL INJECTION)
YY 0469-2011 MEDICAL SURGICAL MASK TECHNOLOGY REQUIRES A BLOOD PENETRATION TEST DEVICE
ISO 22609:2004 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK TEST METHOD FOR RESISTANCE TO SYNTHETIC BLOOD PENETRATION (FIXED VOLUME, HORIZONTAL INJECTION)
ASTM F1862-07 STANDARD TEST METHOD FOR RESISTANCE OF MEDICAL FACE MASKS TO BLOT BY SYNTHETIC BLOOD (HORIZONTAL PROJECTION OF FIXED VOLUME AT A KNOW VELOCITY)
TECHNICAL PARAMETERS:
1. INJECTION DISTANCE: 300mm ~ 305mm ADJUSTABLE
2. NOZZLE DIAMETER: 0.84mm
3. INJECTION SPEED: 450CM/S, 550CM/S, 635CM/S
4. WEIGHT: 35KG
5. POWER SOURCE: AC220V 50HZ
QUANTITY: 1
Learn More - T-6550 MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTER
REFERENCE NUMBER: T-6550
MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTER
TECHNICAL SPECIFICATIONS AND CONFIGURATION:
1. THE INSTRUMENT ADOPTS AN AIR SOURCE THAT CAN PROVIDE (0.5 ~ 30±0.1) KPA PRESSURE TO CONTINUOUSLY PRESSURIZED THE SAMPLE, WHICH IS NOT RESTRICTED BY THE SPACE OF THE TEST SITE;
2. THE AIR PRESSURE RANGE CAN BE ADJUSTED FREELY, AND THE ADJUSTMENT RANGE (0.5 ~ 30) KPA;
3. COLOR TOUCH SCREEN DISPLAY AND OPERATION;
4. THE SAMPLE CLAMPING PAD IS PROCESSED WITH IMPORTED SPECIAL ALUMINUM PROFILES, WHICH IS LIGHT IN MATERIAL, CLEAN IN SURFACE AND NEVER RUSTS.
5. THE INSTRUMENT ADOPTS IMPORTED SPECIAL ALUMINUM WIRE DRAWING PANEL, EQUIPPED WITH METAL KEYS, SENSITIVE OPERATION, NOT EASY TO DAMAGE;
6. CLAMPING DEVICE FOR INSTRUMENT SAMPLES, EQUIPPED WITH LOCKING PROTECTION, TO PREVENT THE SYNTHETIC BLOOD FROM SPLASHING AROUND;
7. CLAMPING FORCE IS ACCURATE AND RELIABLE;
8. THE TEST TANK IS EQUIPPED WITH A SPECIAL PLACEMENT DEVICE, WHICH IS CONVENIENT FOR CUSTOMERS TO OPERATE;
9. THE TEST TANK IS PROCESSED WITH SPECIAL 316 STAINLESS STEEL, AND THE TOP IS EQUIPPED WITH A SPECIAL COVER FOR HIGH TRANSPARENT PROTECTION;
10. THE WASHER BELOW THE SAMPLE IS MADE OF HIGH-QUALITY PTFE MATERIAL AFTER SPECIAL PROCESSING;
11. SQUARE METAL BLOCK NET: OPEN SPACE ≥50°%; BENDING ≤5mm AT 30KPA;
12. INSTRUMENT TIME CONTROL ACCURACY ≤01 SECONDS;
13. THE SHELL OF THE INSTRUMENT IS MADE OF HIGH-QUALITY METAL BAKING PAINT, WHICH IS BEAUTIFUL AND GENEROUS.
14. EQUIPPED WITH PRINTER INTERFACE, CONNECTED TO THE PRINTER CAN DIRECTLY PRINT DATA REPORTS.
TECHNICAL PARAMETERS:
1. SAMPLE SIZE: 75mm X 75mm
2. TEST AREA: 28.26 SQUARE CENTIMETERS
3. AIR PRESSURE ADJUSTMENT RANGE (0.5 ~ 30) KPA
4. EXTERNAL SIZE: 500mm X 500mm X 500mm (L X W X H)
5. WEIGHT OF THE INSTRUMENT: 40 KG
6. POWER SUPPLY: AC220V, 50HZ,SCOPE OF SUPPLY: 1. ONE MAIN MACHINE; 2. TWO PTFE GASKETS; 3. TWO ORDINARY WASHERS; 4. ONE METAL BLOCKING NET; 5. A SET OF SPECIAL LOCKING TOOLS; 6. ONE HIGH-QUALITY SILENT AIR PUMP, [NOTE: SAFETY PRODUCTION LICENSE IS NOT INCLUDED]. 7. EQUIPPED WITH PRINTER INTERFACE; 8. ONE SAMPLE TEMPLATE; 9. ONE PRODUCT CERTIFICATE; 10. ONE COPY OF PRODUCT OPERATION MANUAL.
OPERATION INSTRUCTION:
INSERT THE AIR PUMP OUTPUT PIPE INTO THE OIL AND WATER SEPARATOR OF THE INSTRUMENT AS REQUIRED (PRESSURE 0.1-0.3MPA).
AFTER SWITCHING ON THE POWER, THE STARTUP INTERFACE (NAME OF THE DEVICE) IS DISPLAYED.
PRESS THE "ENTER" BUTTON TO ENTER THE TEST INTERFACE, AS SHOWN IN THE FOLLOWING FIGURE:
CLICK "SETTING” BUTTON, GET INTO PARAMETER SETTING SCREEN, AS BELOW THIS SCREEN CAN SET THE SYSTEM TIME, DATE AND TESTING TIME, AFTER SETTING, CLICK "SAVE” BUTTON TO KEEP THE SETTING DATA. (NOTE: IT REQUIRES 5 MINUTES IN THE STANDARD)
QUANTITY: 1
Learn More - T-6549 CONSTANT TEMPERATURE AND HUMIDITY CHAMBER -FABRIC WATER VAPOR TRANSMISSION RATE
REFERENCE NUMBER: T-6549
CONSTANT TEMPERATURE AND HUMIDITY CHAMBER -FABRIC WATER VAPOR TRANSMISSION RATE
TESTING METER (WITH MOISTURE PERMEABLE CUP)
TECHNICAL DESCRIPTION OF THE INSTRUMENT:
IT IS MAINLY USED TO MEASURE THE MOISTURE PERMEABILITY OF ALL KINDS OF FABRICS, INCLUDING PERMEABLE COATED FABRICS. STRUCTURE PRINCIPLE: ADOPT COMPUTER CONTROL, CREATING A CONSTANT TEMPERATURE, AND HUMIDITY TEST ENVIRONMENT, TEST ENVIRONMENT IN THE CONSTANT TEMPERATURE, AND HUMIDITY, MOISTURE VAPOR TRANSMISSION CUP, PLACED 6 SAMPLE INTO THE GLASS AND THE RUBBER GASKET SEAL, THE CONTAINING HYGROSCOPIC AGENT OR WATER SEAL IS SPECIFIED BY THE WET CUP PLACED IN THE FABRIC SAMPLE TEMPERATURE AND HUMIDITY OF THE ENVIRONMENT, THE SEAL MOISTURE VAPOR TRANSMISSION CUP ACCORDING TO A CERTAIN TIME (INCLUDING SAMPLE AND HYGROSCOPIC AGENT OR WATER) TO CALCULATE THE MOISTURE TRANSMISSION QUALITY CHANGE.
TESTING STANDARD:
GB19082-2009 MEDICAL PRIMARY PROTECTIVE CLOTHING
TECHNICAL REQUIREMENTS GUIDELINES FOR THE SELECTION OF YY-T1498-2016 MEDICAL PROTECTIVE CLOTHING
GB/T12704.1 DETERMINATION OF MOISTURE PERMEABILITY OF FABRICS --HYGROSCOPIC METHOD
DETAILED TECHNICAL SPECIFICATIONS AND CONFIGURATION:
TECHNICAL INDICATORS:
1. TEMPERATURE CONTROL RANGE: -40°C ~ 150°C;RESOLUTION; 0.1 °C
2. HUMIDITY CONTROL RANGE: 50%RH ~ 95% RH±5%
3. SPEED RANGE: 2mm ~ 60mm/MIN
4. CONTROL PRECISION: TEMPERATURE <0.1°C; HUMIDITY + / -1% RH OR LESS
5. CYCLIC WIND SPEED: 0.02 ~ 0.5M/S, 0.3 ~ 0.5M/S
6. TIME CONTROL: 1 ~ 9999H
7. MOISTURE PERMEABLE AREA: 2827 mm 2 (DIAMETER IS 60 mm --NATIONAL STANDARD)
8. QUANTITY OF PERMEABLE CUPS: 6 GB;
9. DRYING BOX CONTROL TEMPERATURE: ROOM TEMPERATURE ~ 199 °C
10. TEST TIME: 1 ~ 999H
11. DRYING BOX STUDIO SIZE: 490 X 400 X 215mm
INSTRUMENT CONFIGURATION:
1. ONE MAIN MACHINE
QUANTITY: 1
Learn More - J-2640 DYEING AND FINISHING PLANT FOR SALE
REFERENCE NUMBER: J-2640
DYEING AND FINISHING PLANT FOR SALEITEM 001
THIES SAMPLE DYEING MACHINE
MODEL: MINISOFT SAMPLE
CAPACITY: 50 KGS
YEAR: 1999
MICROPROCESSOR CONTROLLED
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING REEL AND FABRIC EXIT PLAITOR
QUANTITY: 1ITEM 002
THIES DYEING MACHINE
MODEL ECOSOFT PLUS
3 PORT SPLIT/SPLIT
CAPACITY: 900 KGS
YEAR: 1999
MICROPROCESSOR CONTROLLED
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING REEL AND FABRIC EXIT PLAITOR
QUANTITY: 1ITEM 003
THIES DYEING MACHINE
MODEL: ECOSOFT PLUS
2 PORT SPLIT/SPLIT
CAPACITY: 600 KGS
YEAR: 1999
MICROPROCESSOR CONTROL
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING REEL AND FABRIC EXIT PLAITOR
QUANTITY: 1ITEM 004
THIES DYEING MACHINE
MODEL ECOSOFT PLUS
1 PORT SPLIT/SPLIT
CAPACITY: 300 KGS
YEAR: 1999
MICROPROCESSOR CONTROLLED
VOLTAGE: A460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING REEL AND FABRIC EXIT PLAITOR
QUANTITY: 1ITEM 005
GASTON COUNTY DYEING MACHINE
MODEL: AQUAFLOW
2 PORT
CAPACITY; 250 KGS
YEAR: 1987
MICROPROCESSOR CONTROLLED
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING AND UNLOADING REEL
QUANTITY: 1ITEM 006
THIES DYEING MACHINE
MODEL: SOFT TRD
2 TUBE
CAPACITY: 700 KGS
YEAR: 1999
MICROPROCESSOR CONTROLLED
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
SINGLE ADD TANK WITH MIXER
HEAT EXCHANGER
ALL PUMPS AND MOTORS
LOADING REEL AND FABRIC EXIT PLAITOR
QUANTITY: 1ITEM 007 (also our J-2647)
LAFER OPEN WIDTH COMPACTOR MACHINE
MODEL: KSA 500 2400/2200
YEAR: 1998
LAFER TEXEN CONTROLS
VOLTAGE: 480 VOLTS, 3-PHASE, 60 Hz
COMPOSED OF:
• TENSION BAR ENTRY TO LATTICE ROLL GUIDER
• OPERATOR’S PLATFORM
• PUP TENTER WITH KNIT ENTRY, VERTICAL PIN CHAIN, WITH PLATE GUIDES, RAIL OPENING, PINNING BRUSHES, PINS ONLY, WITH SUPPORT SECTION FOR THE FABRIC IN THE CENTER, AT 10’ THERE IS A STEAMING SECTION, TOTAL LENGTH OF THE TENTER IS 30’, WITH AUTOMATIC LUBRICATION FOR THE CHAIN
• KSA 500 COMPACTOR BENCH WITH TEXEN CONTROLS
• TENSIONLESS FABRIC CONVEYOR
• PLAITOR AND FABRIC SCRAY WITH OPTICAL LOAD SENSOR
• INLINE INSPECTION BATCHER MACHINE, WITHH A BACK LIGHTED BOARD, MANUAL CUT
• SCALE TO WEIGHT THE FABRIC
QUANTITY: 1ITEM 008 (also our J-2648)
SANTEX TUBULAR 4-ROLL EXTRACTION PAD
MODEL: SANTASTRETCH PLUS 140
YEAR: 1998
COMPOSED OF TURNTABLE, DETWISTER, TUBULAR 4-ROLL PAD WITH WET SPREADERS, PLAITOR
WITH ADDITION TANKS FOR SOFTENER
REEL FABRIC PLAITOR EXIT
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
QUANTITY: 1ITEM 009
SANTEX CONVEYOR DRYER FOR OPEN WIDTH AND TUBULAR FABRIC
MODEL: SANTASHRINK 4/5240
YEAR: 1998
SANTEX CONTROLS
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
COMPOSED OF:
• TENSION BAR ENTRY TO LATTICE ROLL GUIDER TO
• (2) SANTEX 2-ROLL PADS, RUBBER OVER RUBBER, 102” WIDE x 12” DIAMETER, STAINLESS STEEL PAN, 10-TON PAD, SWING-AWAY PAN, TENSION BAR WITH 2 STAINLESS STEEL MIXING TANKS, 75 GALLONS EACH
• DRIVEN SCROLL ROLLS WITH EDGE GUIDE CONTROL, WIDTH 95”
• OPERATOR’S PLATFORM
• PUP TENTER WITH KNIT ENTRY 45°, YEAR 1998, VERTICAL PIN CHAIN, 30’ LONG WITH TANDEMATIC PLATE GUIDES, RAIL GUIDES, PINNING BRUSHES, GUIDE SUPPORT FOR THE FABRIC, FABRIC CONVEYOR TO ENTER BOTH TUBULAR OR OPEN WIDTH FABRIC TO
• CONVEYOR DRYER 100” WIDE, 5 ZONES, 3-PASS WITH MAXON BURNERS, 5 CIRCULATING FANS TO CONVEYOR BELT TO PLAITOR
• ALL MOTORS AND SANTEX CONTROLS AND MONITORS
QUANTITY: 1ITEM 010
SANTEX AG TUBULAR COMPACTOR MACHINE
MODEL: SANTASPREAD 140
YEAR: 1998
SANTEX CONTROLS
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
COMPOSED OF:
• TENSIONS BAR ENTRY
• OPERATOR’S PLATFORM
• TENSION DEVICE
• DRIVEN SPREADER BARS
• STEAMING DEVICE
• TUBULAR COMPACTING BENCH
• FELT BLANKET ONTO THE CONVEYOR BELT
• PRECISION PLAITOR
• TABELTOP ELECTRONIC SCALE
QUANTITY: 1ITEM 011
COMET NAPPER
MODEL: PEGSO-X4
YEAR: 1998
VOLTAGE: 480 VOLTS, 3-PHASE, 60 Hz
24 ROLLS WITH TURNING BARS FOR TUBULAR 90” WIDE
XYCOM CONTROLS
12-BAG COLLECTION SYSTEM AND PLAITOR
YEAR: 1996
QUANTITY: 1ITEM 012
STENTEX TENTER FRAME
MODEL: STENTOTHERM 3300
YEAR: 1999
STENTEX CONTROLS
VOLTAGE: 480 VOLTS, 3-PHASE, 60 Hz
COMPOSED OF:
• TENSION ENTRY TO TEXT-STAR TYPE GUIDER TO 2 ROLL PAD
• ADDITION TANK TOP SCRAY PAD TO TEXT-STAR TYPE GUIDER
• TWO ROLL PAD R/R 10 TON
• OPERATOR’S PLATFORM
• WORKING WIDTH 1800mm
• HORIZONTAL PIN CHAIN, KNIT ENTRY
• TANDEMATIC SPLITLEVEL DECURLERS
• OVERFEED
• PINNING BRUSHES
• STEAM BOX
• RAIL GUIDERS, 20 FEET ENTRY, 8 ZONES
• 80 FEET HOUSING
• SCREEN MONITORS
• GAS FIRED, MAXON OVEPAK 408 BURNERS
• HONEYWELL CONTROLS
• 3 FEET COOLING ZONE
• 2 COOLING CANS, SELVEDGE TRIMMERS
• PLIATOR, SCRAY
• ZONE IN LINE INSPECTION BATCHER
QUANTITY: 1ITEM 013
ZIMMER ROTARY SCREEN PRINTING MACHINE
MODEL: R92-S153
YEAR: 1993
COMPOSED OF:
• TENSION BAR SKY ENTRY
• SCRAY
• CORINO BRUSH
• CORINO PRINT GUIDER
• ZIMMER PRINTER, 8 COLOR, 86” BLANEKT
• PRINT CONVEYOR DRYER, 30’ LONG, 3-ZONE, GAS FIRED
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
QUANTITY: 1ITEM 014
Learn More
SAFETY SWITCH BULLET NOSE SLITTER
MODEL: CUTTING
WITH REEL FABRIC PLIATOR
VOLTAGE: 460 VOLTS, 3-PHASE, 60 Hz
QUANTITY: 1 - T-6543 MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
REFERENCE NUMBER: T-6543
MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
SHANDONG INDEPENDENTLY RESEARCH AND DEVELOPMENT THIS COMPREHENSIVE TESTING MACHINE FOR SURGICAL MASK & PROTECTIVE CLOTHING, IT IS WIDELY USED IN A VARIETY OF MASK STRENGTH DETECTION PROJECTS.FEATURES:COMPLY WITH NATIONAL STANDARDS, MEDICAL STANDARDS TESTING REQUIREMENTS, AUTOMATIC SOFTWARE CONTROL SYSTEM, MEET THE REQUIREMENTS OF DATA STORAGE, PRINTING, COMPARISON. THE IMPORTED SERVO MOTOR IS EQUIPPED WITH PRECISION SCREW DRIVE SYSTEM TO ENSURE THE STABILITY OF TEST DATA.
TEST STANDARDS:
GB 19082-2009 TECHNICAL REQUIREMENTS FOR DISPOSABLE PROTECTIVE CLOTHING FOR MEDICAL USE (4.5 BREAKING STRENGTH -THE BREAKING STRENGTH OF MATERIALS IN KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 45N)
(4.6 ELONGATION AT BREAK -THE ELONGATION AT BREAK OF KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 15%)
SELF-PRIMING FILTER RESPIRATOR FOR RESPIRATORY PROTECTION ARTICLES5.6.2 BREATHING BONNET -BREATHING BONNET SHALL BE SUBJECT TO AXIAL TENSION"DISPOSABLE MASK: 10N FOR 10S" "REPLACEABLE MASK: 50N FOR 10S"
(5.9 HEADBAND -HEADBAND SHOULD BEAR THE TENSION "DISPOSABLE MASK: 10N, 10S" "REPLACEABLE HALF MASK: 50N FOR 10S" "FULL MASK: 150N FOR 10S")
5.10 JOINTS AND CONNECTING PARTS -JOINTS AND CONNECTING PARTS SHALL BE SUBJECT TO AXIAL TENSION
"REPLACEABLE HALF MASK: 50N FOR 10S" "FULL COVER 250N FOR 10S"
GB/T 32610-2016 TECHNICAL SPECIFICATION FOR DAILY PROTECTIVE MASKS
(6.9 BREAKING STRENGTH OF THE MASK BELT AND THE CONNECTION BETWEEN THE MASK BELT ANDTHE MASK BODY ≥ 20N)
(6.10 FASTNESS TO BREATHING BONNET: NO SLIPPAGE, BREAKAGE OR DEFORMATION SHALL OCCUR)
YY/T 0699-2013 DISPOSABLE SURGICAL MASK
(4.4 MASK BELT -THE BREAKING FORCE AT THE CONNECTION POINT BETWEEN EACH MASK BELT AND THE MASK BODY IS NOT LESS THAN 10N)
YY 0469-2011 SURGICAL MASK FOR MEDICAL USE (5.4.2 MASK BELT)
GB/T 3923.1-1997 DETERMINATION OF BREAKING STRENGTH AND ELONGATION AT BREAK OF FABRICS (STRIP METHOD)
DISPOSABLE RUBBER INSPECTION GLOVES (6.3 TENSILE PROPERTIES)
INSTRUMENT TECHNICAL PARAMETERS:
SPECIFICATION: 200N (STANDARD) 50N, 100N, 500N, 1000N (OPTIONAL)
ACCURACY: BETTER THAN 0.5RESOLUTION OF FORCE VALUE: 0.1N
DEFORMATION RESOLUTION: 0.001mm
TEST SPEED: 0.01mm/MIN ~ 2000mm/MIN (STEPLESS SPEED REGULATION)
WIDTH OF SAMPLE: 30mm (STANDARD FIXTURE) 50mm (OPTIONAL FIXTURE)
CLAMPING OF SAMPLES: MANUAL (PNEUMATIC CLAMPING CAN BE CHANGED)
STROKE: 700mm (STANDARD) 400mm, 1000mm (OPTIONAL)
QUANTITY: 1
Learn More - T-1138 LORIS BELLINI APPC/LV 150 HANKS CABINET DYEING MACHINE, YEAR 1988 RECONDITIONED 2016
REFERENCE NUMBER: T-1138
LORIS BELLINI APPC/LV 150 HANKS CABINET DYEING MACHINE, YEAR 1988 RECONDITIONED 2016
HANKS CABINET DYEING MACHINE
UNDER PRESSURE TEMPERATURE 110°C
WITH EXTRACTABLES BASKETS
MODEL LORIS BELLINI APPC/LV 150
YEAR 1988 FULLY RECONDITIONED 2016
QUANTITY: 1
Learn More