Search results for: 'can c'
-                  T-6550 MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTER T-6550 MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTERREFERENCE NUMBER: T-6550 MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTER TECHNICAL SPECIFICATIONS AND CONFIGURATION: 1. THE INSTRUMENT ADOPTS AN AIR SOURCE THAT CAN PROVIDE (0.5 ~ 30±0.1) KPA PRESSURE TO CONTINUOUSLY PRESSURIZED THE SAMPLE, WHICH IS NOT RESTRICTED BY THE SPACE OF THE TEST SITE; 2. THE AIR PRESSURE RANGE CAN BE ADJUSTED FREELY, AND THE ADJUSTMENT RANGE (0.5 ~ 30) KPA; 3. COLOR TOUCH SCREEN DISPLAY AND OPERATION; 4. THE SAMPLE CLAMPING PAD IS PROCESSED WITH IMPORTED SPECIAL ALUMINUM PROFILES, WHICH IS LIGHT IN MATERIAL, CLEAN IN SURFACE AND NEVER RUSTS. 5. THE INSTRUMENT ADOPTS IMPORTED SPECIAL ALUMINUM WIRE DRAWING PANEL, EQUIPPED WITH METAL KEYS, SENSITIVE OPERATION, NOT EASY TO DAMAGE; 6. CLAMPING DEVICE FOR INSTRUMENT SAMPLES, EQUIPPED WITH LOCKING PROTECTION, TO PREVENT THE SYNTHETIC BLOOD FROM SPLASHING AROUND; 7. CLAMPING FORCE IS ACCURATE AND RELIABLE; 8. THE TEST TANK IS EQUIPPED WITH A SPECIAL PLACEMENT DEVICE, WHICH IS CONVENIENT FOR CUSTOMERS TO OPERATE; 9. THE TEST TANK IS PROCESSED WITH SPECIAL 316 STAINLESS STEEL, AND THE TOP IS EQUIPPED WITH A SPECIAL COVER FOR HIGH TRANSPARENT PROTECTION; 10. THE WASHER BELOW THE SAMPLE IS MADE OF HIGH-QUALITY PTFE MATERIAL AFTER SPECIAL PROCESSING; 11. SQUARE METAL BLOCK NET: OPEN SPACE ≥50°%; BENDING ≤5mm AT 30KPA; 12. INSTRUMENT TIME CONTROL ACCURACY ≤01 SECONDS; 13. THE SHELL OF THE INSTRUMENT IS MADE OF HIGH-QUALITY METAL BAKING PAINT, WHICH IS BEAUTIFUL AND GENEROUS. 14. EQUIPPED WITH PRINTER INTERFACE, CONNECTED TO THE PRINTER CAN DIRECTLY PRINT DATA REPORTS. TECHNICAL PARAMETERS: 1. SAMPLE SIZE: 75mm X 75mm 2. TEST AREA: 28.26 SQUARE CENTIMETERS 3. AIR PRESSURE ADJUSTMENT RANGE (0.5 ~ 30) KPA 4. EXTERNAL SIZE: 500mm X 500mm X 500mm (L X W X H) 5. WEIGHT OF THE INSTRUMENT: 40 KG 6. POWER SUPPLY: AC220V, 50HZ,SCOPE OF SUPPLY: 1. ONE MAIN MACHINE; 2. TWO PTFE GASKETS; 3. TWO ORDINARY WASHERS; 4. ONE METAL BLOCKING NET; 5. A SET OF SPECIAL LOCKING TOOLS; 6. ONE HIGH-QUALITY SILENT AIR PUMP, [NOTE: SAFETY PRODUCTION LICENSE IS NOT INCLUDED]. 7. EQUIPPED WITH PRINTER INTERFACE; 8. ONE SAMPLE TEMPLATE; 9. ONE PRODUCT CERTIFICATE; 10. ONE COPY OF PRODUCT OPERATION MANUAL. OPERATION INSTRUCTION: INSERT THE AIR PUMP OUTPUT PIPE INTO THE OIL AND WATER SEPARATOR OF THE INSTRUMENT AS REQUIRED (PRESSURE 0.1-0.3MPA). AFTER SWITCHING ON THE POWER, THE STARTUP INTERFACE (NAME OF THE DEVICE) IS DISPLAYED. PRESS THE "ENTER" BUTTON TO ENTER THE TEST INTERFACE, AS SHOWN IN THE FOLLOWING FIGURE: CLICK "SETTING” BUTTON, GET INTO PARAMETER SETTING SCREEN, AS BELOW THIS SCREEN CAN SET THE SYSTEM TIME, DATE AND TESTING TIME, AFTER SETTING, CLICK "SAVE” BUTTON TO KEEP THE SETTING DATA. (NOTE: IT REQUIRES 5 MINUTES IN THE STANDARD) QUANTITY: 1 Learn More
-                  J-2786 VERTICAL MODULE FOR TEMPERATURE MEASUREMENT & FACE RECOGNITION J-2786 VERTICAL MODULE FOR TEMPERATURE MEASUREMENT & FACE RECOGNITIONUSES ROCKCHIP RK3288 / RK 3399 / QUALCOMM MSM8953 HIGH-PERFORMANCE HARDWARE PLATFORM, EQUIPPED WITH INDUSTRIAL GRADE BINOCULAR CAMERA, LIVE FACIAL RECOGNITION SOFTWARE AND INFRARED THERMAL IMAGING MODULE TO SUPPORT FACE-WITH-MASK INDEITIFICATION. SUPPORTS EXPANSION OF VARIOUS PERIPHERALS SUCH AS ID CARD READERS, FINGERPRINT READERS, ETC WHICH CAN BE APPLIED TO GATE PASSAGES AND ATTENDANCE SYSTEM TO ACHIEVE SAFE AND EFFICIENT ACCESS CONTROL FOR PERSONNEL CAN BE USED WITH ACCESS GATES & ATTENDANCE FOR COMMUNITIES, OFFICES, SCHOOLS, HOTELS, PUBLIC VENUES, TRANSPORTATION HUBS AND PUBLIC SERVICE PLACES FEATURES: 
 8 INCH IPS FULL-VIEW LCD DISPLAY
 INDUSTRIAL APPEARANCE, WATERPROOF AND SUNPROOF DESIGN
 STABLE AND RELIABLE
 SUPPORTS A DATABASE OF 30,000 FACES
 THE 1:1 COMPARISON RECOGNITION RATE IS MORE THAN 99.7%
 THE 1:N COMPARISON RECOGNITION RATE IS MORE THAN 96.7% @ 0.1% MISRECOGNITION RATE
 LIVE DETECTION ACCURACY RATE: 98.3% @ 1% MISRECOGNITION RATE
 FACE RECOGNITION PASS SPEED IS LESS THAN 1 SECOND
 SUPPORTS ACCURATE FACE RECOGNITION AND COMPARISON WHILE WEARING A MASK
 USES INDUSTRIAL GRADE BINOCULAR WIDE DYNAMIC CAMERA, NIGHT INFRARED AND LED DUAL PHOTO FLOOD LAMP
 ROCKCHIP RK3288 QUAD-CORE PROCESSOR, ROCKCHIP RK3399 SIX-CORE PROCESSOR, AND QUALCOMM MSM8953 OCTA-CORE PROCESSOR
 SUPPORTS HUMAN BODY TEMPERATURE DETECTION AND DISPLAY (BEST TEMPERATURE DETECTION DISTANCE IS 0.5 METERS, MAXIMUM IS 1 METER), MEASUREMENT ERROR +/- 0.5 °C
 TEMPERATURE CAN BE READ IN ONLY A FEW SECONDS AND THE DEVICE AUTOMATICALLY SOUNDS AN ALARM FOR ABNORMALITIES
 ATTENDANCE TEMPERATURE MEASUREMENT DATA EXPORTED IN REAL TIME
 VARIOUS PERIPHERALS AVAILABLE FOR ID CARD READING, FINGERPRINT READING, IC CARD READING, 2-DIMENSIONAL CODE READING, ETC.
 WITH COMPLETE DOCUMENTATION AND SUPPORT FOR SECONDARY DEVELOPMENT
 SUPPORTS SYSTEM LEVEL, APP OFFLINE LEVEL, APP AND BACKGROUND NETWORK LEVEL MULTIPLE API DOCKINGCAMERA 
 RESOLUTION 2 MILLION PIXELS
 TYPE BINOCULAR WIDE DYNAMIC CAMERA
 APERTURE F2.4
 FOCUSING DISTANCE 50-150CM
 WHITE BALANCE AUTO
 PHOTO FLOOD LIGHT LED AND IR DUAL PHOTO FLOOD LIGHTSCREEN 
 SIZE 8.0 INCH IPS LCD SCREEN
 RESOLUTION 800×1280
 TOUCH NOT SUPPORTED (OPTIONAL SUPPORT)PROCESSOR 
 CPU RK3288 QUAD-CORE (OPTIONAL RK3399 SIX-CORE, MSM8953
 EIGHT-CORE)
 STORAGE EMMC 8GINTERFACE 
 NETWORK MODULE ETHERNET AND WIRELESS (WIFI)
 AUDIO 2.5W / 4R SPEAKERS
 USB 1 USB OTG, 1 USB HOST STANDARD A PORT
 SERIAL COMMUNICATION 1 RS232 SERIAL PORT
 RELAY OUTPUT 1 DOOR OPEN SIGNAL OUTPUT
 WIEGAND ONE WIEGAND 26/34 OUTPUT, ONE WIEGAND 26/34 INPUT
 UPGRADE BUTTON SUPPORT UBOOT UPGRADE BUTTON
 WIRED NETWORK 1 RJ45 ETHERNET SOCKETFUNCTION 
 CREDIT CARD READER NONE (OPTIONAL IC CARD READER, ID CARD, ID CARD)
 FACE DETECTION SUPPORTS DETECTION AND TRACKING OF MULTIPLE PEOPLE AT THE SAME
 TIME
 FACE LIBRARY UP TO 30,000
 1: N FACE RECOGNITION SUPPORT
 1: 1 FACE COMPARISON SUPPORT
 STRANGER DETECTION SUPPORT
 IDENTIFY DISTANCE
 CONFIGURATION
 SUPPORT
 UI INTERFACE CONFIGURATION SUPPORT
 UPGRADE REMOTELY SUPPORT
 INTERFACE INTERFACES INCLUDE DEVICE MANAGEMENT, PERSONNEL / PHOTO
 MANAGEMENT, RECORD QUERY, ETC.
 DEPLOYMENT METHOD SUPPORT PUBLIC CLOUD DEPLOYMENT, PRIVATIZED DEPLOYMENT, LAN
 USE, STAND-ALONE USEINFRARED THERMAL IMAGING MODULE 
 TEMPERATURE DETECTION SUPPORT
 TEMPERATURE DETECTION 1 METER (OPTIMAL DISTANCE 0.5 METER)
 DISTANCE
 TEMPERATURE
 MEASUREMENT ACCURACY
 ≤ ±0.5℃
 TEMPERATURE
 MEASUREMENT RANGE
 10℃~42℃
 THERMAL FIELD OF VIEW 32 X 32℃
 VISITORS' TEMPERATURE IS
 NORMAL AND RELEASED
 DIRECTLY
 SUPPORT
 ABNORMAL TEMPERATURE
 ALARM
 SUPPORT (TEMPERATURE ALARM VALUE CAN BE SET)GENERAL PARAMETERS 
 POWER DC12V(±10%)
 OPERATING TEMPERATURE 0℃~60℃
 STORAGE TEMPERATURE -20℃~60℃
 POWER CONSUMPTION 13.5W(MAX)
 INSTALLATION METHOD GATE BRACKET INSTALLATION
 SIZE : STANDARD:274.24*128*21.48(MM); IC CARD / ID CARD:296.18*132.88*25(MM)PACKING LIST Learn More
 MACHINE * 1, POWER ADAPTER * 1, MANUAL * 1, CERTIFICATE OF CONFORMITY * 1
-                  J-2785 VERTICAL MODULE FOR TEMPERATURE MEASUREMENT & FACE RECOGNITION J-2785 VERTICAL MODULE FOR TEMPERATURE MEASUREMENT & FACE RECOGNITIONUSES ROCKCHIP RK3288 / RK 3399 / QUALCOMM MSM8953 HIGH-PERFORMANCE HARDWARE PLATFORM, EQUIPPED WITH INDUSTRIAL GRADE BINOCULAR CAMERA, LIVE FACIAL RECOGNITION SOFTWARE AND INFRARED THERMAL IMAGING MODULE TO SUPPORT FACE-WITH-MASK INDEITIFICATION. SUPPORTS EXPANSION OF VARIOUS PERIPHERALS SUCH AS ID CARD READERS, FINGERPRINT READERS, ETC WHICH CAN BE APPLIED TO GATE PASSAGES AND ATTENDANCE SYSTEM TO ACHIEVE SAFE AND EFFICIENT ACCESS CONTROL FOR PERSONNEL CAN BE USED WITH ACCESS GATES & ATTENDANCE FOR COMMUNITIES, OFFICES, SCHOOLS, HOTELS, PUBLIC VENUES, TRANSPORTATION HUBS AND PUBLIC SERVICE PLACES FEATURES: 
 8 INCH IPS FULL-VIEW LCD DISPLAY
 INDUSTRIAL APPEARANCE, WATERPROOF AND SUNPROOF DESIGN
 STABLE AND RELIABLE
 SUPPORTS A DATABASE OF 30,000 FACES
 THE 1:1 COMPARISON RECOGNITION RATE IS MORE THAN 99.7%
 THE 1:N COMPARISON RECOGNITION RATE IS MORE THAN 96.7% @ 0.1% MISRECOGNITION RATE
 LIVE DETECTION ACCURACY RATE: 98.3% @ 1% MISRECOGNITION RATE
 FACE RECOGNITION PASS SPEED IS LESS THAN 1 SECOND
 SUPPORTS ACCURATE FACE RECOGNITION AND COMPARISON WHILE WEARING A MASK
 USES INDUSTRIAL GRADE BINOCULAR WIDE DYNAMIC CAMERA, NIGHT INFRARED AND LED DUAL PHOTO FLOOD LAMP
 ROCKCHIP RK3288 QUAD-CORE PROCESSOR, ROCKCHIP RK3399 SIX-CORE PROCESSOR, AND QUALCOMM MSM8953 OCTA-CORE PROCESSOR
 SUPPORTS HUMAN BODY TEMPERATURE DETECTION AND DISPLAY (BEST TEMPERATURE DETECTION DISTANCE IS 0.5 METERS, MAXIMUM IS 1 METER), MEASUREMENT ERROR +/- 0.5 °C
 TEMPERATURE CAN BE READ IN ONLY A FEW SECONDS AND THE DEVICE AUTOMATICALLY SOUNDS AN ALARM FOR ABNORMALITIES
 ATTENDANCE TEMPERATURE MEASUREMENT DATA EXPORTED IN REAL TIME
 VARIOUS PERIPHERALS AVAILABLE FOR ID CARD READING, FINGERPRINT READING, IC CARD READING, 2-DIMENSIONAL CODE READING, ETC.
 WITH COMPLETE DOCUMENTATION AND SUPPORT FOR SECONDARY DEVELOPMENT
 SUPPORTS SYSTEM LEVEL, APP OFFLINE LEVEL, APP AND BACKGROUND NETWORK LEVEL MULTIPLE API DOCKINGCAMERA 
 RESOLUTION 2 MILLION PIXELS
 TYPE BINOCULAR WIDE DYNAMIC CAMERA
 APERTURE F2.4
 FOCUSING DISTANCE 50-150CM
 WHITE BALANCE AUTO
 PHOTO FLOOD LIGHT LED AND IR DUAL PHOTO FLOOD LIGHTSCREEN 
 SIZE 8.0 INCH IPS LCD SCREEN
 RESOLUTION 800×1280
 TOUCH NOT SUPPORTED (OPTIONAL SUPPORT)PROCESSOR 
 CPU RK3288 QUAD-CORE (OPTIONAL RK3399 SIX-CORE, MSM8953
 EIGHT-CORE)
 STORAGE EMMC 8GINTERFACE 
 NETWORK MODULE ETHERNET AND WIRELESS (WIFI)
 AUDIO 2.5W / 4R SPEAKERS
 USB 1 USB OTG, 1 USB HOST STANDARD A PORT
 SERIAL COMMUNICATION 1 RS232 SERIAL PORT
 RELAY OUTPUT 1 DOOR OPEN SIGNAL OUTPUT
 WIEGAND ONE WIEGAND 26/34 OUTPUT, ONE WIEGAND 26/34 INPUT
 UPGRADE BUTTON SUPPORT UBOOT UPGRADE BUTTON
 WIRED NETWORK 1 RJ45 ETHERNET SOCKETFUNCTION 
 CREDIT CARD READER NONE (OPTIONAL IC CARD READER, ID CARD, ID CARD)
 FACE DETECTION SUPPORTS DETECTION AND TRACKING OF MULTIPLE PEOPLE AT THE SAME
 TIME
 FACE LIBRARY UP TO 30,000
 1: N FACE RECOGNITION SUPPORT
 1: 1 FACE COMPARISON SUPPORT
 STRANGER DETECTION SUPPORT
 IDENTIFY DISTANCE
 CONFIGURATION
 SUPPORT
 UI INTERFACE CONFIGURATION SUPPORT
 UPGRADE REMOTELY SUPPORT
 INTERFACE INTERFACES INCLUDE DEVICE MANAGEMENT, PERSONNEL / PHOTO
 MANAGEMENT, RECORD QUERY, ETC.
 DEPLOYMENT METHOD SUPPORT PUBLIC CLOUD DEPLOYMENT, PRIVATIZED DEPLOYMENT, LAN
 USE, STAND-ALONE USEINFRARED THERMAL IMAGING MODULE 
 TEMPERATURE DETECTION SUPPORT
 TEMPERATURE DETECTION 1 METER (OPTIMAL DISTANCE 0.5 METER)
 DISTANCE
 TEMPERATURE
 MEASUREMENT ACCURACY
 ≤ ±0.5℃
 TEMPERATURE
 MEASUREMENT RANGE
 10℃~42℃
 THERMAL FIELD OF VIEW 32 X 32℃
 VISITORS' TEMPERATURE IS
 NORMAL AND RELEASED
 DIRECTLY
 SUPPORT
 ABNORMAL TEMPERATURE
 ALARM
 SUPPORT (TEMPERATURE ALARM VALUE CAN BE SET)GENERAL PARAMETERS 
 POWER DC12V(±10%)
 OPERATING TEMPERATURE 0℃~60℃
 STORAGE TEMPERATURE -20℃~60℃
 POWER CONSUMPTION 13.5W(MAX)
 INSTALLATION METHOD GATE BRACKET INSTALLATION
 SIZE : STANDARD:274.24*128*21.48(MM); IC CARD / ID CARD:296.18*132.88*25(MM)PACKING LIST 
 MACHINE * 1, POWER ADAPTER * 1, MANUAL * 1, CERTIFICATE OF CONFORMITY * 1QUANTITY: 1 Learn More
-                  T-6544 SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK T-6544 SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASKREFERENCE NUMBER: T-6544 SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK TECHNICAL INDICATORS: 1. THE PROTRUDING SAMPLE FIXING DEVICE CAN SIMULATE THE ACTUAL USE STATE OF THE MASK, SET ASIDE THE TEST TARGET AREA WITHOUT DESTROYING THE SAMPLE, AND DISTRIBUTE THE SYNTHETIC BLOOD IN THE TARGET AREA OF THE SAMPLE. 2. THE SPECIAL FIXED-PRESSURE INJECTION DEVICE CAN EJECT A CERTAIN VOLUME OF SYNTHETIC BLOOD IN A CONTROLLED TIME. 3. IT CAN FULLY SIMULATE THE INJECTION SPEED CORRESPONDING TO THE AVERAGE BLOOD PRESSURE OF HUMAN BODY OF 10.6KPA, 16KPA AND 21.3KPA. 4. A FIXED TARGET PLATE IS SET TO BLOCK THE HIGH-PRESSURE EDGE PART OF THE INJECTED LIQUID FLOW AND ONLY ALLOW THE STEADY FLOW PART TO BE SPRAYED ON THE SAMPLE, WHICH INCREASES THE ACCURACY AND REPEATABILITY OF THE LIQUID VELOCITY SPRAYED ON THE SAMPLE. STANDARDS: MEDICAL RESPIRATOR TECHNICAL REQUIREMENTS, 5.5 SYNTHETIC BLOOD PENETRATION BARRIER PERFORMANCE YY/T 0691-2008 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK RESISTANCE TO SYNTHETIC BLOOD PENETRABILITY TEST METHOD (FIXED VOLUME, HORIZONTAL INJECTION) YY 0469-2011 MEDICAL SURGICAL MASK TECHNOLOGY REQUIRES A BLOOD PENETRATION TEST DEVICE ISO 22609:2004 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK TEST METHOD FOR RESISTANCE TO SYNTHETIC BLOOD PENETRATION (FIXED VOLUME, HORIZONTAL INJECTION) ASTM F1862-07 STANDARD TEST METHOD FOR RESISTANCE OF MEDICAL FACE MASKS TO BLOT BY SYNTHETIC BLOOD (HORIZONTAL PROJECTION OF FIXED VOLUME AT A KNOW VELOCITY) TECHNICAL PARAMETERS: 1. INJECTION DISTANCE: 300mm ~ 305mm ADJUSTABLE 2. NOZZLE DIAMETER: 0.84mm 3. INJECTION SPEED: 450CM/S, 550CM/S, 635CM/S 4. WEIGHT: 35KG 5. POWER SOURCE: AC220V 50HZ QUANTITY: 1 Learn More
-                  M-6440 WARPING MACHINE FOR MEDICAL BANDAGE PLANT M-6440 WARPING MACHINE FOR MEDICAL BANDAGE PLANTREFERENCE NUMBER: M-6440 WARPING MACHINE FOR MEDICAL BANDAGE PLANT WARPING MACHINE ADJUST SPEED BY FREQUENCY CONVERTER, EASY TO ADJUST, SAVES ENERGY TIGHT PRESS AUTOMATICALLY, PRESSURE IS ADJUSTABLE, EVEN WARPING COUNT LENGTH AUTOMATICALLY, WARPING LENGTH CAN BE PRE-SET COMB TYPE EXPANSION REED, OPEN IN TOP, EASY TO ROW LINE AND CONVENIENT TO ADJUST WIDTH ON BOTH MACHINE HEAD AND CREEL OF YARNS, THERE ARE CONTROL DEVICES FOR STOPPING THE MACHINE WHEN THE YARN BREAKS, TO ENSURE THE MACHINE WILL STOP WHEN THE YARN BREAKS WARPING SPEED: UP TO 350 METERS PER MINUTE REMOTE CONTROL TO START AND STOP MACHINE AUTOMATICALLY, AVAILABLE DISTANCE 20M AVAILABLE WARP ROLL: Ø300mm TO 410mm, INSIDE WARP BEAM LENGTH IS 255mm TO 260mm, IT CAN BE MADE ON CUSTOMERS’ DIFFERENT REQUESTS MOTOR POWER: 1.5KW ONE WARPING MACHINE CAN WORK FOR 20 BANDAGE WEAVING MACHINES QUANTITY: 1 Learn More
-                  M-5184 COSMETIC COTTON PAD MAKING MACHINE (24,000PCS/H)REFERENCE NUMBER: M-5184 (1313243YS12UF) L COSMETIC COTTON PAD MAKING MACHINE (24,000PCS/H) QUANTITY AVAILABLE: 1 Learn More M-5184 COSMETIC COTTON PAD MAKING MACHINE (24,000PCS/H)REFERENCE NUMBER: M-5184 (1313243YS12UF) L COSMETIC COTTON PAD MAKING MACHINE (24,000PCS/H) QUANTITY AVAILABLE: 1 Learn More
-                  M-5140 MACHINE TO PRODUCE VARIOUS TYPES OF COTTON PADS M-5140 MACHINE TO PRODUCE VARIOUS TYPES OF COTTON PADSREFERENCE NUMBER: M-5140 (1212WYNKXX11) L MACHINE TO PRODUCE VARIOUS TYPES OF COTTON PADS MODEL: 96 DESIGNED FOR PRODUCTION OF VARIOUS TYPES OF COTTON PADS ALSO CALLED COTTON ROUNDS, COTTON SQUARES, DISC COTTON, FACIAL COTTON COTTON PADS FOR HYGIENIC USE, COSMETIC USE, INDUSTRIAL USE, AND MEDICAL APPLICATIONS PRODUCT OUTPUT DEPENDS ON THE SIZE OF THE PADS AND CAN REACH UP TO 1080 PIECES/MINUTE VARIOUS SHAPES OF COTTON PADS CAN BE PRODUCED AUTOMATICALLY IF SEPARATE TOOLS OF DIFFERENT SHAPES OR SIZES ARE INSTALLED THE COTTON PAD PRODUCER HAS THE OPTION OF MANUFACTURING EITHER EMBOSSED OR PLAIN COTTON PADS THE PRODUCT IS PACKAGED IN POLYBAGS IN SEMI AUTOMATIC MODE THE MACHINE CAN ALSO BE CONNECTED TO THE AUTOMATIC PACKAGING DEVICE TO OBTAIN DIFFERENT KINDS OF PACKAGING QUANTITY: 1 Learn More
-                  T-6545 MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTER T-6545 MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTERREFERENCE NUMBER: T-6545 MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTER PRODUCT INTRODUCTION: MASK BACTERIA FILTRATION EFFICIENCY KEY PERFORMANCE INDICATORS (BFE) DETECTOR TESTER NOT ONLY CONFORMS TO THE REQUIREMENTS OF MEDICAL SURGICAL MASKS TECHNOLOGY YY0469-2011 APPENDIX B IN THE TEST METHOD FOR FILTER EFFICIENCY (BFE) BACTERIA FIRST B. 1.1.1 TEST INSTRUMENT, BUT ALSO CONFORMS TO THE AMERICAN SOCIETY FOR TESTING MATERIAL ASTMF2100, ASTMF2101, THE REQUIREMENTS OF THE EUROPEAN EN14683 STANDARDS, INNOVATIVE IMPROVEMENTS WERE MADE ON THE BASIS OF THIS, WITH DOUBLE PNEUMATIC CONTRAST SAMPLING METHOD AT THE SAME TIME, IMPROVE THE PRECISION OF SAMPLING,IT IS SUITABLE FOR MEASURING AND TESTING DEPARTMENTS, SCIENTIFIC RESEARCH INSTITUTES, MASK MANUFACTURERS AND OTHER RELEVANT DEPARTMENTS TO TEST THE PERFORMANCE OF MASK BACTERIAL FILTRATION EFFICIENCY. EXECUTION STANDARD: Q/0212 ZRB003-2015 MEDICAL SURGICAL MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR RELATED INTELLECTUAL PROPERTY: NO.: ZL200820224142.6 ELECTRIC FLOW CONTROL VALVE NO.: ZL200820224143.0 GAS CAPACITY NO.: ZL200920308391.8 AIR FILTRATIONMATERIAL FILTRATION EFFICIENCY DETECTOR PRODUCT FEATURES: NEGATIVE PRESSURE TEST SYSTEM TO ENSURE THE SAFETY OF OPERATORS; BUILT -IN PERISTALTIC PUMP IN NEGATIVE PRESSURE CABINET, A, B TWO -WAY, SIX ANDERSEN; THE PERISTALTIC PUMP FLOW CAN BE SET; THE FLOW RATE OF NIGHT SPRAY CAN BE SET AND THE ATOMIZATION EFFECT IS GOOD. EMBEDDED HIGH SPEED INDUSTRIAL MICROCOMPUTER CONTROL; 10.4 INCHES INDUSTRIAL HIGH BRIGHTNESS COLOR TOUCH SCREEN; USB INTERFACE, SUPPORT U DISK DATA STORAGE; CABINET BUILT-IN HIGH BRIGHTNESS LIGHTS; BUILT-IN LEAKAGE PROTECTION SWITCH TO PROTECT THE SAFETY OF OPERATORS; THE INNER LAYER OF THE CABINET IS MADE OF STAINLESS STEEL, THE OUTER LAYER IS SPRAYED WITH PLASTIC AND COLD-ROLLED, AND THE INNER AND OUTER LAYERS ARE INSULATED AND FLAME RETARDANT. THE FRONT SWITCH TYPE GLASS DOOR IS CONVENIENT FOR THE EXPERIMENTER TO OBSERVE AND OPERATE. DETACHABLE BRACKET, ADJUSTABLE BRACKET HEIGHT; SUPPORTING AND MOVING DUAL PURPOSE CASTERS. QUANTITY: 1 Learn More
-                  T-6575 NON-INVASIVE VENTILATOR T-6575 NON-INVASIVE VENTILATORNON-INVASIVE VENTILATOR Learn More
 CERTIFICATE: CE
 MEDICAL VENTILATOR
 TECHNICAL PARAMETERS OF DOUBLE LEVEL VENTILATOR
 VENTILATOR TYPE: ELECTRIC CONTROL
 SCOPE OF APPLICATION: TREATMENT AND TITRATION OF SLEEP APNEA HYPOPNEA SYNDROME, SEVERE SNORING, AND RESPIRATORY INSUFFICIENCY.
 DISPLAY INTERFACE: 3.5-INCH LED SCREEN, CHINESE OPERATING SYSTEM
 *VENTILATION MODE: CPAP, S, S/T, T
 PRESSURE RANGE:
 PRESSURE RANGE: 4-30CMH2O (±0.5CMH2O)
 PRESSURE ACCURACY: + 0.5CMH2O
 PARAMETER SETTING:
 DELAYED BOOST: 0-60MIN, SET THE DIVISION INTERVAL 5MIN
 INITIAL PRESSURE: 4CMH2O TREATMENT PRESSURE / RESPIRATORY PRESSURE SETTING
 THERAPEUTIC PRESSURE: 4-20CMH2O (IN CPAP MODE)
 TARGET TIDAL VOLUME: 150ML - 1500ML, ON/ OFF
 MAXIMUM SUCTION PRESSURE: 4-30CMH2O, (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
 MINIMUM SUCTION PRESSURE: 4-30CMH2O (NOT HIGHER THAN THE SUCTION PRESSURE), (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
 INSPIRATORY PHASE PRESSURE: 4-30CMH2O
 EXPIRATORY PRESSURE: 4-30CMH2O
 EXPIRATORY DECOMPRESSION: PATIENT, OFF, 1-3, THREE ADJUSTABLE
 MANUAL VOLTAGE REGULATION: 0-2 GEAR, 0-2CMH2O (ONLY AVAILABLE IN CPAP MODE)
 INSPIRATORY SENSITIVITY: 1-8 STALLS
 EXPIRATORY SENSITIVITY: 1-8 STALLS
 RESPIRATORY FREQUENCY: 3-40 TIMES / MIN
 INSPIRATORY TIME: 0.3-3.0S
 BACKUP RATE: ON / OFF, DEFAULT 10
 PRESSURE RISE TIME: 1-4 STALLS
 HUMIDIFIER: 1-5 ADJUSTABLE IN 5 GEARS
 *TITRATION FUNCTION: SUPPORT MANUAL AND AUTOMATIC PRESSURE TITRATION, BUILT-IN REMOTE WIRELESS COMMUNICATION MODULE, COMPLETE THE RANDOM SWITCHING OF SINGLE AND DOUBLE LEVEL MODES IN THE TITRATION PROCESS, AND CONTROL MORE THAN 11 VENTILATOR PARAMETERS AT THE SAME TIME.
 AUXILIARY FUNCTION: AUTOMATIC AIR LEAKAGE COMPENSATION, AUTOMATIC STARTUP, AUTOMATIC SHUTDOWN, DELAYED SHUTDOWN, SCREEN BACKLIGHT ADJUSTMENT
 MONITORING PARAMETERS: PRESSURE, TIDAL VOLUME, RESPIRATORY RATE, MINUTE VENTILATION VOLUME, AIR LEAKAGE VOLUME, INSPIRATORY TIME, BLOOD OXYGEN SATURATION
 WAVY CURVE: PRESSURE TIME WAVEFORM, FLOW RATE TIME WAVEFORM
 ALARM PROMPT: PIPELINE AND MASK FALLING OFF, AIR LEAKAGE PROMPT, POWER INTERRUPTION, TREATMENT MACHINE FAILURE, HUMIDIFIER FAILURE, LOW VOLTAGE, HIGH RESPIRATORY RATE, LOW RESPIRATORY RATE, LOW MINUTE VENTILATION VOLUME, LOW BLOOD OXYGEN, REPLACEMENT OF FILTER COTTON, FULL SD CARD, RE INSERTION OF SD CARD
 *DATA MANAGEMENT:
 NETWORK DATA: BMC + RESPIRATORY HEALTH MANAGEMENT CLOUD PLATFORM
 SD CARD DATA: RESART NPAP DATA ANALYSIS SOFTWARE
 PARTS:
 SD CARD: STANDARD
 SD CARD SLOT: STANDARD
 PIPING: 9 22MM, 1.8M LONG
 FACE SHIELD: F2 NOSE MASK AS STANDARD
 NOISE: LESS THAN 30DB
 ENVIRONMENT CONDITION:
 TEMPERATURE:
 (WHEN USED) 5 -35 C
 (DURING TRANSPORTATION AND STORAGE) -20 C -55 C
 ATMOSPHERIC PRESSURE:
 (WHEN USED) 760-1060HPA
 (DURING TRANSPORTATION AND STORAGE) 760-1060HPA
 WORKING HOURS: MORE THAN 8 HOURS
 POWER SUPPLY REQUIREMENTS:
 AC VOLTAGE: 100-240V
 FREQUENCY: 50HZ/60HZ
 INPUT POWER: LESS THAN 2A
 WATERPROOF LEVEL: IP22 - DRIP PROOF EQUIPMENT
 INSTRUMENT SIZE: 290mm X 180mm X 134mm
 WEIGHT: 1.5KG (EXCLUDING HUMIDIFIER) 2.5KG (INCLUDING HUMIDIFIER)
 ITEM 001
 QUANTITY: 10 SETS-999 SETS
 ITEM 002
 QUANTITY: 1,000 SETS-9,999SETS
 ITEM 003
 QUANTITY: ≥10,000 SETS
-                  V-1467 3 SIDE MEDICAL BANDAGES PACKAGING MACHINE V-1467 3 SIDE MEDICAL BANDAGES PACKAGING MACHINEREFERENCE NUMBER: V-1467 3 SIDE MEDICAL BANDAGES PACKAGING MACHINE THIS MACHINE IS SUITABLE TO PACK MEDICAL BANDAGES, MEDICINE, FOOD, COMMODITY, ETC. INCLUDES: SPECIAL POUCH ADJUSTING SYSTEM, GOOD FOR PACKING PRODUCTS WITH MULTIFORM SIZE, MULTIFORM SPECIFICATION. COMPUTER CONTROL SYSTEM. SPECIAL IN-FEED SYSTEM, IN –FEED POSITION CAN BE ADJUSTED DURING MACHINE OPERATION. SLIPPAGE SEALING SYSTEM CAN ADJUST PACKAGING FILM THICKNESS: 0.03 TO 0.08mm SPEED: 40 TO 220 POUCHES PER MINUTE PACKAGING FILM WIDTH: 100 TO 350mm FIGURATION (APPROXIMATE): 4350 (L) X 1050 (W) X 1600 (H) POWER: 3.2 KW WEIGHT (APPROXIMATE): 500KG SIZE OF POUCH: ADJUSTABLE, PER CUSTOMER. QUANTITY: 1 Learn More
