T-6546 PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKREFERENCE NUMBER: T-6546PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKINTRODUCTIONMEDICAL SURGICAL MASK PARTICLE FILTRATION EFFICIENCY PFE TESTER IS SUITABLE FOR MEDICAL INSTRUMENT INSPECTION CENTER, SAFETY PROTECTION INSPECTION CENTER, LABOR PROTECTION INSPECTION CENTER, DRUG INSPECTION CENTER, DISEASE PREVENTION AND CONTROL CENTER, TEXTILE INSPECTION CENTER, HOSPITAL, MASK AND RESPIRATOR MANUFACTURERS, ETC.FEATURESTHE PFE TESTER FOR PARTICLE FILTRATION EFFICIENCY OF SURGICAL MASKS IS EQUIPPED WITH A SPECIAL SALT AEROSOL GENERATOR, WHICH CAN PRODUCE AEROSOLS WITH SPECIFIC PARTICLE SIZE AND CONCENTRATION.EQUIPPED WITH A SERIES OF SPECIAL FIXTURE, SUITABLE FOR THE DETECTION OF ALL KINDS OF MASKS.BUILT-IN HIGH LIFE PHOTOMETER MODULE, SAMPLING TIME ACCUMULATION, PROMPT LIGHT CLEANING.AUTOMATIC CONTROL OF AEROSOL GENERATION, AUTOMATIC CALCULATION OF CAPTURE EFFICIENCY AND MASK AIRFLOW RESISTANCE, REDUCE HUMAN INTERVENTION.BUILT-IN HIGH PRECISION ELECTRONIC FLOWMETER AND HIGH PERFORMANCE SAMPLING PUMP TO ENSURE FLOW STABILITY.PARAMETERTEST FLOW: PARAMETER RANGE: (5 ~ 100) L/MIN; RESOLUTION: (5 ~ 100) L/MIN;MAXIMUM ALLOWABLE ERROR: ±1%PRESSURE DETECTION RANGE: PARAMETER RANGE: (0 ~ 2500) PA; RESOLUTION: 0.1PA; MAXIMUM ALLOWABLE ERROR: ±1%CONCENTRATION DETECTION RANGE: PARAMETER RANGE: (0.001 ~ 100) 0 G/L;DETECTION ACCURACY: 1% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100%DETECTION REPEATABILITY: 5% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100% MEDIAN DIAMETER OF SALT AEROSOL PARTICLES (CMD): (0.075±0.02)MMEDIAN AEROSOL PARTICLE NUMBER DIAMETER (CMD) (OPTIONAL): (0.185±0.02) MOPERATING TEMPERATURE: 20±5CLearn MoreINSTRUMENT NOISE: <60DB(A)POWER SUPPLY: AC220V±10%, 50HZMAIN MACHINE SIZE: (LENGTH 700 X WIDTH 720 X HEIGHT 1450) mmQUANTITY: 1 -
T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKSREFERENCE NUMBER: T-6547
RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
INTRODUCTION
THE RESPIRATOR RESISTANCE TESTER IS USED TO MEASURE THE INSPIRATORY RESISTANCE AND EXPIRATORY RESISTANCE OF RESPIRATORS AND RESPIRATOR PROTECTORS UNDER SPECIFIED CONDITIONS. IT IS APPLICABLE TO THE NATIONAL LABOR PROTECTION EQUIPMENT INSPECTION INSTITUTIONS, MASK MANUFACTURERS FOR THE GENERAL MASKS, DUST MASKS, MEDICAL MASKS, ANTI-SMOG MASKS PRODUCTS OF THE RELEVANT TESTING AND INSPECTION.
STANDARD
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
GB 2626-2006 RESPIRATOR SELF-SUCTION FILTER RESPIRATOR AGAINST PARTICULATE MATTER
GB/T 32610-2016 TECHNICAL SPECIFICATIONS FOR DAILY PROTECTIVE MASKS
FEATURES:
1. HIGH-DEFINITION LCD DISPLAY.
2. DIGITAL DIFFERENTIAL PRESSURE METER WITH HIGH PRECISION IMPORTED BRAND.
3. HIGH PRECISION IMPORTED BRAND OF DIGITAL FLOWMETER, WITH HIGH FLOW CONTROL ACCURACY FEATURES.
4. THE RESPIRATOR RESISTANCE TESTER CAN SET UP TWO MODES: EXHALATION DETECTION AND INHALATION DETECTION.
5. AUTOMATIC PIPELINE SWITCHING DEVICE OF RESPIRATOR SOLVES THE PROBLEM OF PIPE EXTUBATION AND WRONG CONNECTION WHEN TESTING.
PARAMETER:
1. FLOWMETER RANGE: 0 ~ 100L/MIN, ACCURACY IS 3%
2. DIGITAL PRESSURE DIFFERENCE METER RANGE: 0 ~ 2000PA, ACCURACY: 1PA
3. PUMPING CAPACITY OF AIR PUMP: >100L/MIN
4. OVERALL SIZE: 460 X 1080 X 670mm
5. POWER SOURCE: AC220V 50HZ 650W
6. WEIGHT: 55KG
QUANTITY: 1
Learn More -
T-6552 MASK AIR TIGHTNESS TESTERREFERENCE NUMBER: T-6552
MASK AIR TIGHTNESS TESTER
MASK AIR TIGHTNESS TESTER
HOW TO CHOOSE A HIGH-QUALITY MASK NOT ONLY DEPENDS ON THE FILTERING EFFICIENCY OF THEMASK, BUT ALSO TO CONFIRM WHETHER THE MASK IS COMPLETELY IN CONTACT WITH THE FACE, OTHERWISE AEROSOL PARTICLES SUCH AS GERMS THAT HAVE NOT BEEN FILTERED BY THE MASK WILL BE INHALED FROM THE INADEQUATE ADHESION. THEREFORE, IT IS VERY IMPORTANT TO CHECK THE WEARING STATUS OF THE MASK. THE EUROPEAN AND AMERICAN COUNTRIES HAVE LISTED THE APPLICATION TEST OF THE MASK AS A STRONG INSPECTION ITEM.
FOR EXAMPLE, THE N95 MASK IS ONE OF 9 TYPES OF PARTICULATE PROTECTIVE MASKS CERTIFIED BY NIOSH (NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH). "N" INDICATES OIL RESISTANCE."95" INDICATES THAT THE PARTICLE CONCENTRATION IN THE MASK IS MORE THAN 95% LOWER THAN THAT OF THE PARTICLES OUTSIDE THE MASK WHEN EXPOSED TO THE SPECIFIED NUMBER OF SPECIAL TEST PARTICLES. N95 IS NOT A SPECIFIC PRODUCT NAME, AS LONG AS IT MEETS THE N95 STANDARD AND PASSES THE NIOSH REVIEW, IT CAN BE CALLED "N95 MASK".
N95 TYPE MASKS, IN ADDITION TO THE FILTERING EFFICIENCY OF THE MASKS, THE CLOSENESS OF THE MASKS TO THE FACE IS ONE OF THE IMPORTANT FACTORS THAT DETERMINE THE EFFECTIVENESS OF THE USE OF THE MASKS. THE SUITABILITY OF DIFFERENT TYPES OF MASKS FOR THE HUMAN FACE VARIES GREATLY.
THEREFORE, BEFORE USING A MASK, THE SUITABILITY OF THE MASK SHOULD BE CHECKED FIRST. DURING THETIGHTNESS TEST OF THE WEARER'S FACE, ENSURE THAT AIR CAN PASS IN AND OUT THROUGH THE MASK WHEN IT IS CLOSE TO THE EDGE OF THE FACE. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTION PERFORMANCE. IT CONFORMS TO THE CHINESE RESPIRATOR STANDARD GB2626-2019 STANDARD, OSHA / CSA STANDARD AND CHINA GENERAL ADMINISTRATION OF QUALITY SUPERVISION, INSPECTION AND QUARANTINE "GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS" JOINTLY ISSUED BY THE CHINA NATIONAL STANDARDIZATION ADMINISTRATION COMMITTEE.
ADHESION (SUITABILITY TEST): THE MASK DESIGN SHOULD PROVIDE GOOD ADHESION. THE OVERALL FIT FACTOR OF THE MASK SHOULD NOT BE LESS THAN 100. THIS TEST THE REQUIREMENTS WERE FORMALLY IMPLEMENTED ON AUGUST 1, 2011.
Learn MoreMASK TIGHTNESS TESTER USES CNC TECHNOLOGY, SUITABLE FOR 100 / 99 / P3 / HEPASERIES MASKS DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING DISPOSABLE DUST MASKS SUCH ASN95 / N90 / KN95), GAS MASKS / BREATHING MASKS, ADHESIVENESS TEST OF HALF-MASK AND FULL FACE MASK, INDEPENDENT OR COMPUTER CONTROL, FIVE LANGUAGES SWITCH DISPLAY, EQUIPPED WITH MULTIPLE COMMUNICATION INTERFACES (USB, ETHERNET), WIFI CAN ALSO BE ENABLED, ONE COMPUTERCAN CONTROL FOUR INSTRUMENTS AT THE SAME TIME.PARAMETER:CONCENTRATION RANGE: 0 ~ 100,000 / CM3GRAIN DIAMETER: 0.02 ~ 1.0^MFLOW: SAMPLING FLOW: 100CM3 / MINTOTAL FLOW: 700CM3 / MINCLOSENESS COEFFICIENT TEST: DIRECT TEST (COUT/ CIN)LIQUOR: 99.5% + ISOPROPANOL (ANALYTICAL GRADE)DISPLAY: 7INCH TRUE COLOR TOUCH SCREENCOMMUNICATION INTERFACE: USB X 3 (HOST X 2,DEVICE X 1) ETHERNET INTERFACE X1CONNECTION PORT: ENVIRONMENT PORT, SAMPLING PORTWIFI: EQUIPPEDLANGUAGES: ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESEFLOW CONTROL: SENSOR CONTROLPC CONTROLLABLE OPERATION: ONE COMPUTER CAN CONTROL 4 INSTRUMENTS AT THE SAME TIMEDATA OUTPUT FORMAT: MICROSOFT EXCELWORKING TEMPERATURE: 15 ~ 35 °CPOWER SOURCE: AC 110 —240V 50 / 60HZAPPEARANCE SIZE: 208 X 117 X 262MMWEIGHT: 2.1KGACCESSORIES: ALCOHOL REAGENT BOTTLE, PROTECTIVE CAP, REAGENT STICK, ZERO-COUNT FILTER, STRAINER, SAMPLING TUBE, INSTRUCTION MANUAL, AC ADAPTER, TOUCH SCREEN PEN, OPTIONAL COMPUTER.OPTIONAL: TEST KIT FOR TIGHTNESS COEFFICIENTIN ORDER TO PREVENT INFECTION AT THE MEDICAL SITE AND DURING LABOR WORK, WORKERS MUST BE PROTECTED FROM INHALABLE HAZARDOUS SUBSTANCES IN THE WORKPLACE, AND RESPIRATORS SUCH AS MASKS MUST BE WORN DURING WORK.SELECT A RESPIRATOR, SUCH AS A MASK, BASED ON YOUR FACIAL FEATURES, AND EVALUATE THE TIGHTNESS BETWEEN THE RESPIRATOR, SUCH AS A MASK AND THE FACE, TO CHECK WHETHER THERE ARE GAPS OR LEAKS THAT PUT WORKERS AT RISK. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTIVE PERFORMANCE. SECURITY EXPERTS WILL ALSO DEVELOP PROTECTION SCHEMES AND STANDARD REGULATIONS BASED ON THE RESULTS OF THE TIGHTNESS TEST. WIDELY USED IN HOSPITALS, MANUFACTURING PLANTS, PRODUCTION SITES, FIREFIGHTING WORKPLACES AND OTHER OFFICIAL TESTING AGENCIES.MASK TIGHTNESS TESTER FEATURES:• QUANTITATIVE TIGHTNESS TEST FOR RESPIRATORS SUCH AS MASKS (QNFT)• APPLICABLE TO 100/99 / P3 / HEPA SERIES MASK DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING N95 / N90 / KN95 AND OTHER DISPOSABLE DUST MASKS)• ADHESION TEST OF HALF MASK AND FULL FACE MASK• GAS MASK TIGHTNESS TEST• PAPR MASK TIGHTNESS TEST• SCBA RESPIRATOR MASK TIGHTNESS TEST• 7INCH TRUE COLOR TOUCH SCREEN• INDEPENDENT OR COMPUTER CONTROLLED• USING CNC TECHNOLOGY• ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESE LANGUAGE SWITCHING DISPLAY• COMPLIES WITH US OSHA STANDARDS, CANADIAN STANDARDS ASSOCIATION (CSA) GUIDELINES, INCLUDING N95• EQUIPPED WITH A VARIETY OF COMMUNICATION INTERFACES (USB, ETHERNET), AND CAN ALSO ENABLE WIFI• ONE COMPUTER CAN CONTROL FOUR INSTRUMENTS AT THE SAME TIMEQUANTITY: 1 -
J-2812 HANDHELD PARTICLE COUNTER0.2 µm - 2 µm
0.1 CFM (2.83LPM) Flow Rate
View 6 Particle Sizes Simultaneously
-STANDARD 6 CHANNELS: 0.2, 0.3, 0.5, 0.7, 1.0, 2.0 µm
COUNTING EFFICIENCY: 50%@0.2µm;100% FOR PARTICLES >0.3 µm (per ISO 21501-4)
DESIGNED FOR ISO 21501-4 COMPLIANCE: UNIT-TO-UNIT ACCURACY AND REPEATABILITY
BRIGHT 3.5"(8.89 cm) COLOR TOUCH SCREEN DISPLAY
REMOVABLE / RECHARGEABLE LI-ION BATTERY
LARGE MEMORY FOR STORING DATA (3,000 SAMPLES)
CONCENTRATION LIMIT - 4,000,000 / ft3
TEMPERATURE / RELATIVE HUMIDITY PROBE INCLUDED
ALPHANUMERIC LOCATION LABELS
TEST WIZARD FOR CLEANROOM PASS / FAIL REPORTS: FS-209E, ISO 14644-1 OR EU GMP ANNEX 1
EASILY CONFIGURABLE INTERFACE WITH ZOOM CAPABILITY
INTERNAL AUDIBLE ALARM
ERGONOMICALLY DESIGNED
LIGHTWEIGHT
OPEN ARCHITECTURE CONNECTIVITY WITH OPC SERVERINCLUDES
OPERATING MANUAL ON CD, REMOVABLE BATTERY, DIRECT MOUNT INSOKINETIC SAMPLE PROBE, PURGE FILTER, TEMPERATURE/RELATIVE HUMITIY PROBE, POWER SUPPLY, POWER CORD, LMS EXPRESS SOFTWARELEAD TIME: SOMETIME IN MAY 2020
QUANTITY: 1
Learn More -
P-8697 PP MELT BLOWN NONWOVEN FABRIC FOR MASKS MELTBLOWN, MELT-BLOWN, MIDDLE LAYER, MASK FILTERENVIRONMENT: 380V/50Hz
Learn More
RAW MATERIAL: MFI=1000 TO 1600
PRODUCT SPECIFICATION: WIDTH: 1600mm (AS PER 50G/M2)
WEIGHT RANGE: 10 TO 80G/M2
PRODUCT CAPACITY: 80KG/H (AS PER WEIGHT RANGE ≥80G/M2, WIDTH: 1600mm)
MAX MECHANICAL SPEED: 0 TO 50M/MIN
FIBER FINENESS: 2 TO 5μM
TOTAL INSTALLED POWER: 400 KW
OUTPUT FOR 25G/M2: ABOUT 1 TON
DIMENSION: 16MX8MX6M
QUANTITY: 1 -
L-7129 NONWOVEN SMS PRODUCTION LINE, 1600mm, SPUNBONDED, MELT BLOWNPP CHIPS FOR MELTBLOWN: 1200 TO 2000
FABRIC WIDTH: 1600mm
2 SPINNING BEAMS FOR SPUNBOND & 1 FOR MELTBLOWN
BASIC WEIGHT: SMS 9 TO 80 GRAMS PER SQUARE METER
SS: 15 TO 100 GRAMS PER SQUARE METERPRODUCT:
SMS LAMINATED NONWOVEN FABRIC
SS SPUNBOND NONWOVEN FABRIC SS
M MELTBLOWN NONWOVEN FABRIC MTO MAKE HYGENIC FABRICS SUCH AS BABY DIAPERS, SANITARY NAPKINS, ADULT DIAPERS, MEDICAL OPERATION SUITS, OPERATION CAPS, OPERATIONS SHOES, MASKS, ETC.
CONSISTING OF:
3 X FEEDING SYSTEMS
AUTOMATIC VACUUM SUCTION FOR BOTH MAIN MATERIAL AND ADDITIVES
CAPACITY (SB + MB) 2 X 520 KGS/H, (SB) 2 X 200 KGS/HR
WITH THREE HOPPERS, THREE SUPPLIYING DEVICESSPUNBOND SYSTEM
2 X EXTRUDERS
DIAMETER: 150mm
CAPACITY: 450 KGS/HR
L/D 30:1
DRIVE POWER: 110 KW
HEATING POWER: 90 KW2 X RECYCLING SYSTEMS
DIAMETER: 105mm
CAPACITY: 100 KGS PER HOUR
L/D: 15:12 X MELT FILTERS
WORKING TEMPERATURE: UP TO 280 CELSIUS
FILTRATION CAPACITY: 520 KGS PER HOUR2 X METERING PUMPS
TYPE: GEAR PUMP
FLOW VOLUME: 250 ML/R
DESIGNING TEMPERATURE: 280 CELSIUS2 X MELT PIPELINES
WITH STATIC MIXER2 X MONOMER EXHAUSTER
INCLUDING BLOWER, CHILLER, PIPELINE, VALVE, INSULATION, ETC2 X SPINNING BEAMS
SINGLE COAT-HANGER MELT DISTRIBUTION
DESIGNING PRESSURE: 9MPA
WORKING TEMPERATURE: MAX 280 CELSIUS4 X SPINNERETS
HOLE DIAMETER: 0.45mm
L/D: 5:1
15,500 HOLESMELTBLOWN SYSTEM
1 X EXTRUDER
DIAMETER 120mm
CAPACITY: 280 KGS/HR
L/D: 30:1
DRIVE POWER: 75 KW
HEATING POWER: 80 KW1 X MELT FILTER
FILTRATION PRECISION: 20 TO 60 MICROMETERS
FILTRATION: 280 KGS PER HOUR1 X METERING PUMP
GEAR PUMP
MAX. FLOW VOLUME: 100ML/R
DESIGNED TEMPERATURE: 300 CELSIUS1 X MELT PIPELINE
WITH STATIC MIXER1 X SPINNING BEAM
INCLUDING STRETCHING CHANNEL, NOZZLE, ETC. WITH INSULATION MATERIAL
DESIGNED PRESSURE: 6 MPA2 X SPINNING DIE PACKS
COMPACT DIE PACKS
HOLE DIAMETER: 0.35mm
L/D: 12:1
# OF HOLES: 42HPI1 X SCREW BLOWER
INCLUDING MUFFLE, PRESSURE REDUCER VALVE, PIPELINE, ETC.
POWER: 200 KW1 X HOT AIR SYSTEM
FLOW VOLUME: 6000 CUBIC METERS PER HOUR
WORKING TEMP: MAX 350 CELSIUS
INCLUDING HEATER, STAINLESS STEEL PIPELINE, ETC.
POWER: 290 KW1 X OFF-LINE CONVEYOR
RANGE OF SPEED: 5 TO 100 METERS PER MINUTE1 X CONVEYOR
MECHANICAL SPEED: MAX 400 METERS PER MINUTE
BELT WIDTH AND PENETRATION
3800±10mm, 10000 CUBIC METERS PER H.M21 X CALENDAR
DOUBLE ROLLS HEATED BY OIL
PROCESS SPEED: 350 METERS PER MINUTE
EMBOSSING WIDTH: UP TO 2000mm
MAX LINEAR PRESSURE: 110 DAN/C
MAX. TEMP OF EMBOSSING ROLLER, 180 CELSIUS1 X WINDER
ONLINE CHANGING ROLL, ONLINE EDGE CUTTING, TENSION CONTROL
MAX. LINEAR SPEED: 350 METERS PER MINUTE
WIDTH: 1600mm
WIND DIAMETER: MAX 1500mm1 X SLITTER
MAX. LINE SPEED: 600 METERS PER MINUTE
MAX. WIND DIAMETER: 1200mm
MIN. SLITTING WIDE: 120mm
22 CIRCULAR BLADES1 X STEEL PLATFORM
1 X ELECTRICAL CONTROL SYSTEM
2 X OIL OVEN
1 X AIR CONDITIONING SYSTEM
1 X WATER COOLING SYSTEM
1 X CLEANING EQUIPMENTS FOR DIE PACK
1 X AUXILIARY PLATFORM
1 X AUXILIARY EQUIPMENTS
1 X LABORATORY TESTING DEVICE
Learn More -
D-2380 AUTOMATED FILTER TESTERTHE AUTOMATED FILTER TESTER MODEL 9981 CONTINUES TO BE THE BEST SOLUTION FOR TESTING PARTICULATE RESPIRATOR FILTERS, DISPOSABLE FILTERING FACE PIECES, AND A WIDE ASSORTMENT OF FILTER MEDIA. OUR FILTER TESTERS HAVE BEEN USED IN QUALITY CONTROL AND MANUFACTURING BY LEADING FILTER AND FILTER MEDIA MANUFACTURERS AND REFERENCE TEST INSTITUTES AROUND THE WORLD FOR MORE THAN 20 YEARS DUE TO THEIR PROVEN DURABILITY AND RELIABILITY, WHICH IS VALUED IN DEMANDING MANUFACTURING ENVIRONMENTS AND QA/QC LABORATORIES.
THIS MODEL OFFERS HIGHER SENSITIVITY AND RESOLUTION THAN PREVIOUS MODELS - UP TO 99.9999 PERCENT EFFICIENCY HAS BEEN PRODUCED WITH EMERY OIL AT CONCENTRATIONS OF 200 MG/M³. THE NEW SERVICEABLE PHOTOMETERS ARE LOWERING THE COST OF OWNERSHIP AND ENABLE PROACTIVE SCHEDULING OF MAINTENANCE FOR MINIMAL IMPACT TO PRODUCTION SCHEDULES.
THE MODEL 9981 FEATURES A HIGH DEGREE OF AUTOMATION AND SELF-DIAGNOSTICS THAT GREATLY SIMPLIFIES OPERATION, INCREASES THROUGHPUT, AND IMPROVES OVERALL MEASUREMENT PERFORMANCE. WHEN LOOKING FOR A STAND-ALONE TESTER TO DETERMINE PENETRATION OR FILTER EFFICIENCY AND PRESSURE DROP OF YOUR MEDIA, FILTER CARTRIDGES, FILTERS, AND RESPIRATORY MASKS THE MODEL 9981 IS UP TO THE CHALLENGE.
THE BUILT-IN CAPABILITY TO TEST WITH SALT AND OIL MEANS THAT JUST ONE UNIT IS NEEDED TO TEST YOUR PRODUCT TO:
• US 42 CFR 84, GB2626, JMOL
• ISO 16900-3, EN 143
• ISO 23328-1 (AND MORE)
APPLICATIONS
• USA COMMERCIAL RESPIRATOR REGULATION 42 CFR PART 84
• CHINESE RESPIRATOR STANDARD GB2626
• JAPANESE RESPIRATOR STANDARD JMOL
• EUROPEAN EN 143, ISO 16900-3 AND RELATED RESPIRATOR STANDARDS
• ISO 23328-1 (TESTING FILTERS FOR ANAESTHETIC USE)
• FILTER MEDIA TESTING
• CONSULT OUR REPRESENTATIVE FOR MORE DETAILS
INCLUDED ITEMS
• REFERENCE MEDIA SHEETS
• FLAT-MEDIA AND GRAVIMETRIC FILTER HOLDER
• REFERENCE PRESSURE DROP PLATE
• OIL AND SALT AEROSOL GENERATORS
• SELECTED SPARE PARTS
• CONTACT US FOR CUSTOM FILTER HOLDERSEMAIL US FOR PRICE & PICTURES
Learn More
INCLUDE OUR REFERENCE NUMBER -
J-2787 FACE MASK EAR STRAP SPOT WELDING MACHINE, 12 MASKS PER MINUTECAPACITY: 10 TO 12 PIECES PER MINUTE
900 WATTS @ 28 kHz
ADJUSTABLE WELDING
ADJUSTABLE PRESSURE
ADJUSTABLE SPEED
LOW ENERGY CONSUMPTION
FOOT PEDAL CONTROLS, EASILY OPERATED
VOLTAGE: 220 VOLTS, 50 Hz (OR AS PER CUSTOMER)
AIR PRESSURE: 3 KG PER cm2
Weight: 30.5 KG
DIMENSIONS: 600 x 530 x 1100mmQUANTITY: 1
Learn More -
M-5300 UNDER PAD PRODUCTION LINEREFERENCE NUMBER: M-5300 (131342BVGT12UF) L UNDER PAD PRODUCTION LINE UNDER PAD PRODUCTION LINE MODEL: 100CD PRODUCTS TO BE PRODUCED: 3 SIZES OF DISPOSABLE UNDER PAD (SIZE: 600x900mm, 600x600mm, 600x400mm) MECHANICAL DRIVING SYSTEM WITH INVERTER CONTROL PRODUCT STRUCTURE: FLUFF +SAP; TOP TISSUE; BOTTOM TISSUE; TOP SHEET; BACK SHEET QUANTITY AVAILABLE: 1 Learn More -
M-5184 COSMETIC COTTON PAD MAKING MACHINE (24,000PCS/H)REFERENCE NUMBER: M-5184 (1313243YS12UF) L COSMETIC COTTON PAD MAKING MACHINE (24,000PCS/H) QUANTITY AVAILABLE: 1 Learn More