Search results for: 'reference number -v'
- Related search terms
- Reference
- Reference No
- Reference Number: J
- Reference Number: J-'
- Reference Number:'
- T-6544 SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
REFERENCE NUMBER: T-6544
SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
TECHNICAL INDICATORS:
1. THE PROTRUDING SAMPLE FIXING DEVICE CAN SIMULATE THE ACTUAL USE STATE OF THE MASK, SET ASIDE THE TEST TARGET AREA WITHOUT DESTROYING THE SAMPLE, AND DISTRIBUTE THE SYNTHETIC BLOOD IN THE TARGET AREA OF THE SAMPLE.
2. THE SPECIAL FIXED-PRESSURE INJECTION DEVICE CAN EJECT A CERTAIN VOLUME OF SYNTHETIC BLOOD IN A CONTROLLED TIME.
3. IT CAN FULLY SIMULATE THE INJECTION SPEED CORRESPONDING TO THE AVERAGE BLOOD PRESSURE OF HUMAN BODY OF 10.6KPA, 16KPA AND 21.3KPA.
4. A FIXED TARGET PLATE IS SET TO BLOCK THE HIGH-PRESSURE EDGE PART OF THE INJECTED LIQUID FLOW AND ONLY ALLOW THE STEADY FLOW PART TO BE SPRAYED ON THE SAMPLE, WHICH INCREASES THE ACCURACY AND REPEATABILITY OF THE LIQUID VELOCITY SPRAYED ON THE SAMPLE.
STANDARDS:
MEDICAL RESPIRATOR TECHNICAL REQUIREMENTS, 5.5 SYNTHETIC BLOOD PENETRATION BARRIER PERFORMANCE
YY/T 0691-2008 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK RESISTANCE TO SYNTHETIC BLOOD PENETRABILITY TEST METHOD (FIXED VOLUME, HORIZONTAL INJECTION)
YY 0469-2011 MEDICAL SURGICAL MASK TECHNOLOGY REQUIRES A BLOOD PENETRATION TEST DEVICE
ISO 22609:2004 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK TEST METHOD FOR RESISTANCE TO SYNTHETIC BLOOD PENETRATION (FIXED VOLUME, HORIZONTAL INJECTION)
ASTM F1862-07 STANDARD TEST METHOD FOR RESISTANCE OF MEDICAL FACE MASKS TO BLOT BY SYNTHETIC BLOOD (HORIZONTAL PROJECTION OF FIXED VOLUME AT A KNOW VELOCITY)
TECHNICAL PARAMETERS:
1. INJECTION DISTANCE: 300mm ~ 305mm ADJUSTABLE
2. NOZZLE DIAMETER: 0.84mm
3. INJECTION SPEED: 450CM/S, 550CM/S, 635CM/S
4. WEIGHT: 35KG
5. POWER SOURCE: AC220V 50HZ
QUANTITY: 1
Learn More - M-5138 SQUARE COTTON PAD PRODUCTION MACHINEREFERENCE NUMBER: M-5138 (12121745V11UX) L SQUARE COTTON PAD PRODUCTION MACHINE MODEL: XF SPEED: 1800 TO 3000 PCS/MINUTE PRODUCT SIZE: WIDTH: 40 TO 100mm, LENGTH 40 TO 100mm RAW MATERIAL SIZE: 1000mm, DIAMETER LESS THAN 1000mm POWER: 380V FREQUENCY: 50 HZ TOTAL POWER: 4.5KW DIMENSION: LENGTH: 2500mm, WIDTH: 1900mm, HEIGHT: 1600mm WEIGHT: 2500KG QUANTITY AVAILABLE: 1 Learn More
- H-2366 MASK AND MEDICAL GOWN LABORATORY EQUIPMENT
REFERENCE NUMBER: T-6334
Learn More
ALL KINDS OF MASK TESTING INSTRUMENTS
(SURGICAL MASK)
(DISPOSABLE SURGICAL MASK)
(MEDICAL PROTECTIVE MASK)
(DAILY PROTECTIVE MASK)
ITEM 001
COMPREHENSIVE TENSION TESTER FOR SURGICAL MASK
ITEM 002
MASK SYNTHETIC BLOOD PENETRATION DETECTOR
ITEM 003
BACTERIAL PERCOLATION EFFICIENCY (BFE) TESTER
ITEM 004
PARTICLE EFFICIENCY (PFE) TESTER
ITEM 005
RESPIRATOR RESISTANCE TESTER
ITEM 006
MASK FLAME RETARDANT PERFORMANCE TESTER
ITEM 007
FABRIC SURFACE MOISTURE TESTER
ITEM 008
MASK AIR TIGHTNESS TESTER
ITEM 009
TEMPERATURE PRETREATMENT CONSTANT TEMPERATURE AND HUMIDITY CHAMBER
ITEM 010
COLOR FASTNESS TO FRICTION TESTER
ITEM 011
TEXTILE FORMALDEHYDE TESTER
ITEM 012
PH METER
REFERENCE NUMBER: T-6335
RESPIRATORY PROTECTIVE EQUIPMENT & SELF-IMBIBITION FILTER ANTI-PARTICULATE RESPIRATOR TESTING INSTRUMENTS
ITEM 001
FIITRATION EFFICIENCY N CLASS SODIUM CHLORIDE PARTICLES, P CLASS OIL PARTICLES
PARTICLE RATE EFFICIENCY TESTER
ITEM 002
RESPIRATOR RESISTANCE TESTER
ITEM 003
BREATHING VALVE TIGHTNESS TESTER
ITEM 004
AXIAL TENSION TESTER FOR BREATHING BONNET
ITEM 005
AXIAL TENSION TESTER FOR BREATHING BONNET
ITEM 006
MASK FIELD TESTER
ITEM 007
HEADBAND TENSILE TESTING MACHINE
ITEM 008
JOINT PARTS&AXIAL TENSILE TESTING MACHINE
ITEM 009
MASK FLAME RETARDANT PERFORMANCE TESTER
ITEM 010
TEMPERATURE PRETREATMENT CONSTANT TEMPERATURE AND HUMIDITY CHAMBER
REFERENCE NUMBER: T-6336
MEDICAL DISPOSABLE PROTECTIVE CLOTHING TESTING INSTRUMENTS
ITEM 001
WATER PENETRATION RESISTANCE TESTER FOR PROTECTIVE CLOTHING
ITEM 002
MOISTURE PERMEABILITY TESTER FOR PROTECTIVE CLOTHING
ITEM 003
SURFACE MOISTURE RESISTANCE TESTER
ITEM 004
ANTISYNTHETIC BLOOD PENETRANT DETECTOR
ITEM 005
TENSILE TESTER FOR BREAKING STRENGTH AND ELONGATION
ITEM 006
FLAME RETARDANT PERFORMANCE TESTER FOR PROTECTIVE CLOTHING
ITEM 007
FRICTION ELECTRIFICATION TESTER FOR PROTECTIVE CLOTHING (FRENCH LADLE)
REFERENCE NUMBER: T-6337
DISPOSABLE MEDICAL RUBBER INSPECTION GLOVES TESTING INSTRUMENTS
ITEM 001
PLASTIC FILM THICKNESS TESTER
ITEM 002
RUBBER GLOVES TENSILE STRENGTH TESTER
ITEM 003
RUBBER GLOVES WATERPROOF TESTER
ITEM 004
RUBBER GLOVES PRETREATMENT AGING BOX
More information is available upon request.
E-mail us for price, pictures, video, or diagram.
Include our reference number - D-2380 AUTOMATED FILTER TESTER
THE AUTOMATED FILTER TESTER MODEL 9981 CONTINUES TO BE THE BEST SOLUTION FOR TESTING PARTICULATE RESPIRATOR FILTERS, DISPOSABLE FILTERING FACE PIECES, AND A WIDE ASSORTMENT OF FILTER MEDIA. OUR FILTER TESTERS HAVE BEEN USED IN QUALITY CONTROL AND MANUFACTURING BY LEADING FILTER AND FILTER MEDIA MANUFACTURERS AND REFERENCE TEST INSTITUTES AROUND THE WORLD FOR MORE THAN 20 YEARS DUE TO THEIR PROVEN DURABILITY AND RELIABILITY, WHICH IS VALUED IN DEMANDING MANUFACTURING ENVIRONMENTS AND QA/QC LABORATORIES.
THIS MODEL OFFERS HIGHER SENSITIVITY AND RESOLUTION THAN PREVIOUS MODELS - UP TO 99.9999 PERCENT EFFICIENCY HAS BEEN PRODUCED WITH EMERY OIL AT CONCENTRATIONS OF 200 MG/M³. THE NEW SERVICEABLE PHOTOMETERS ARE LOWERING THE COST OF OWNERSHIP AND ENABLE PROACTIVE SCHEDULING OF MAINTENANCE FOR MINIMAL IMPACT TO PRODUCTION SCHEDULES.
THE MODEL 9981 FEATURES A HIGH DEGREE OF AUTOMATION AND SELF-DIAGNOSTICS THAT GREATLY SIMPLIFIES OPERATION, INCREASES THROUGHPUT, AND IMPROVES OVERALL MEASUREMENT PERFORMANCE. WHEN LOOKING FOR A STAND-ALONE TESTER TO DETERMINE PENETRATION OR FILTER EFFICIENCY AND PRESSURE DROP OF YOUR MEDIA, FILTER CARTRIDGES, FILTERS, AND RESPIRATORY MASKS THE MODEL 9981 IS UP TO THE CHALLENGE.
THE BUILT-IN CAPABILITY TO TEST WITH SALT AND OIL MEANS THAT JUST ONE UNIT IS NEEDED TO TEST YOUR PRODUCT TO:
• US 42 CFR 84, GB2626, JMOL
• ISO 16900-3, EN 143
• ISO 23328-1 (AND MORE)
APPLICATIONS
• USA COMMERCIAL RESPIRATOR REGULATION 42 CFR PART 84
• CHINESE RESPIRATOR STANDARD GB2626
• JAPANESE RESPIRATOR STANDARD JMOL
• EUROPEAN EN 143, ISO 16900-3 AND RELATED RESPIRATOR STANDARDS
• ISO 23328-1 (TESTING FILTERS FOR ANAESTHETIC USE)
• FILTER MEDIA TESTING
• CONSULT OUR REPRESENTATIVE FOR MORE DETAILS
INCLUDED ITEMS
• REFERENCE MEDIA SHEETS
• FLAT-MEDIA AND GRAVIMETRIC FILTER HOLDER
• REFERENCE PRESSURE DROP PLATE
• OIL AND SALT AEROSOL GENERATORS
• SELECTED SPARE PARTS
• CONTACT US FOR CUSTOM FILTER HOLDERSEMAIL US FOR PRICE & PICTURES
Learn More
INCLUDE OUR REFERENCE NUMBER - M-5300 UNDER PAD PRODUCTION LINEREFERENCE NUMBER: M-5300 (131342BVGT12UF) L UNDER PAD PRODUCTION LINE UNDER PAD PRODUCTION LINE MODEL: 100CD PRODUCTS TO BE PRODUCED: 3 SIZES OF DISPOSABLE UNDER PAD (SIZE: 600x900mm, 600x600mm, 600x400mm) MECHANICAL DRIVING SYSTEM WITH INVERTER CONTROL PRODUCT STRUCTURE: FLUFF +SAP; TOP TISSUE; BOTTOM TISSUE; TOP SHEET; BACK SHEET QUANTITY AVAILABLE: 1 Learn More
- V-1468 COTTON GAUZE MEDICAL COMPRESS FOLDING AND BAGGING MACHINE, WHICH AUTOMATICALLY FOLDS COTTON GAUZE COMPRESSES
REFERENCE NUMBER: V-1468
SURGICAL GAUZE COMPRESSING, FOLDING, AND BAGGING MACHINE
COTTON GAUZE MEDICAL COMPRESS FOLDING AND BAGGING MACHINE, WHICH AUTOMATICALLY FOLDS COTTONG GAUZE, COMPRESSES, AND THEN PACKS THEM INDIVIDUALLY OR IN GROUPS INTO SACHETS.
FEATURES
USEFUL WIDTH: 45 CM
NUMBER OF TRACKS: MAXIMUM 2 (VARIES ACCORDING TO THE SIZE OF COMPRESSES)
SIZE:
MINIMUM DIMENSIONS OF COMPRESSES: 5 CM X 5 CM
MAXIMUM DIMENSIONS OF COMPRESSES: 10 CM X 20 CM (16 PLIES)
ALL THE USUAL OR INTERMEDIATE SIZES CAN BE PRODUCED ON THE MACHINE BY SIMPLE ADJUSTMENTS.
NUMBER OF PLIES 8 / 12 / 16 / 20 / 24 / 28 / 32 PLIES (VARIES ACCORDING TO THE SIZE OF COMPRESSES)
FOLDING: THE CONVENTIONAL FOLDING IS THE 5-FOLD "SURGICAL" OR "AMERICAN" TYPE, WITH EDGES AND CORNERS TUCKED-IN, HOWEVER BY OFFSETTING FOLDS OTHER COMBINATIONS ARE POSSIBLE.
STACKING: STACKING IS CARRIED OUT IN THE CHANNELS WHERE THE COMPRESSES ARE COUNTED AND READY TO BE MANUALLY INSERTED INTO PAPER BAGS.
PRODUCTION :
EXAMPLES OF THEORETICAL PRODUCTIONS:
5 CM X5 CM 8 PLIES (2 TRACKS) 13200 COMPRESSES PER HOUR
7.5 CM X 7.5 CM 12 PLIES (2 TRACKS) 13200 COMPRESSES PER HOUR
10 CM X 10 CM 12 PLIES (2 TRACKS) 12000 COMPRESSES PER HOUR
OPTIONS:
BARIUM FIXING TRACK BY TRACK
GAUZE ROLL LOADING BY PNEUMATIC CYLINDERS"
FEATURES LIST:
MATERIAL SUPPORT ADJUSTABLE IN WIDTH,
POSITIVE UNWINDING WITH TENSION CHECK ADJUSTABLE TRACK BY TRACK,
MULTIPLE LENGTH FOLDING DEVICE ADJUSTABLE TRACK BY TRACK,
SPRAY HUMIDIFYING SYSTEM,
SUCTION SYSTEM,
ANTI-STATIC BARS,
ADJUSTABLE FLY CUT MODULE MOTORISED WITH BRUSHLESS MOTOR,
THREE CROSS FOLDING MECHANISMS WITH INDEPENDENT ADJUSTMENT OF EACH FOLD,
TRANSFER BELTS FOR THE COMPRESSES,
MOTORISED LATERAL UNWINDING OF THE PAPER ROLL MODULE,
DEVICE FOR INDIVIDUAL, IN MULTIPLES OR IN SHINGLED FORM PACKAGING - WITH A CHANGEABLE
NUMBER OF COMPRESSES BY SACHET,
CHECK OF FOLLOWING OPERATIONS TRACK BY TRACK:
. END OF FABRIC,
. PRESENCE OF SEAM,
. PRESENCE OF CROSS-FOLDED COMPRESS,
. JAM PREVENTION BEFORE PACKAGING.
COLD SEALING BY PRESSURE AND CUTTING OF SACHETS IN PRINTED AND ZONED PAPER,
POWER SYSTEM OF PACKAGING BY BRUSHLESS MOTOR ALLOWING FOR FLY ADJUSTMENT OF:
. THE COMPRESS POSITION IN THE SACHET,
. THE CROSSWISE KNURLING POSITION,
. THE CROSSWISE CUTTING OF SACHETS.
ACCELERATION RAMP BY FREQUENCY VARIATION,
MACHINE OPERATION BY TOUCH-SENSITIVE SCREEN:
. STORABLE CONFIGURATIONS,
. CLEAR LANGUAGE FAULT DISPLAY,
. COUNTERS : TOTALIZER, PRE-SELECTION, ETC.,
. SOUND AND VISUAL ALARMS,
. "INCIDENT" STATISTICS.
STARTING, STOPPING, STEP BY STEP - BY REMOTE CONTROL.
* CONTINUOUS, TRACK BY TRACK INTEGRATION OF ULTRASONIC BARIUM FIXING.
* PAPER ROLL LOADING BY PNEUMATIC CYLINDERS.
* INK JET MARKING UP TILL 8 LINES.
* SACHETS QUALITY CONTROL DEVICE: EITHER A CHECK BY PHOTO CELLS, OR BY CAMERAS,
* FAULTY SACHET EJECTION DEVICE.
* TABLE WITH CONVERGING BELTS.
Learn More - T-6552 MASK AIR TIGHTNESS TESTER
REFERENCE NUMBER: T-6552
MASK AIR TIGHTNESS TESTER
MASK AIR TIGHTNESS TESTER
HOW TO CHOOSE A HIGH-QUALITY MASK NOT ONLY DEPENDS ON THE FILTERING EFFICIENCY OF THEMASK, BUT ALSO TO CONFIRM WHETHER THE MASK IS COMPLETELY IN CONTACT WITH THE FACE, OTHERWISE AEROSOL PARTICLES SUCH AS GERMS THAT HAVE NOT BEEN FILTERED BY THE MASK WILL BE INHALED FROM THE INADEQUATE ADHESION. THEREFORE, IT IS VERY IMPORTANT TO CHECK THE WEARING STATUS OF THE MASK. THE EUROPEAN AND AMERICAN COUNTRIES HAVE LISTED THE APPLICATION TEST OF THE MASK AS A STRONG INSPECTION ITEM.
FOR EXAMPLE, THE N95 MASK IS ONE OF 9 TYPES OF PARTICULATE PROTECTIVE MASKS CERTIFIED BY NIOSH (NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH). "N" INDICATES OIL RESISTANCE."95" INDICATES THAT THE PARTICLE CONCENTRATION IN THE MASK IS MORE THAN 95% LOWER THAN THAT OF THE PARTICLES OUTSIDE THE MASK WHEN EXPOSED TO THE SPECIFIED NUMBER OF SPECIAL TEST PARTICLES. N95 IS NOT A SPECIFIC PRODUCT NAME, AS LONG AS IT MEETS THE N95 STANDARD AND PASSES THE NIOSH REVIEW, IT CAN BE CALLED "N95 MASK".
N95 TYPE MASKS, IN ADDITION TO THE FILTERING EFFICIENCY OF THE MASKS, THE CLOSENESS OF THE MASKS TO THE FACE IS ONE OF THE IMPORTANT FACTORS THAT DETERMINE THE EFFECTIVENESS OF THE USE OF THE MASKS. THE SUITABILITY OF DIFFERENT TYPES OF MASKS FOR THE HUMAN FACE VARIES GREATLY.
THEREFORE, BEFORE USING A MASK, THE SUITABILITY OF THE MASK SHOULD BE CHECKED FIRST. DURING THETIGHTNESS TEST OF THE WEARER'S FACE, ENSURE THAT AIR CAN PASS IN AND OUT THROUGH THE MASK WHEN IT IS CLOSE TO THE EDGE OF THE FACE. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTION PERFORMANCE. IT CONFORMS TO THE CHINESE RESPIRATOR STANDARD GB2626-2019 STANDARD, OSHA / CSA STANDARD AND CHINA GENERAL ADMINISTRATION OF QUALITY SUPERVISION, INSPECTION AND QUARANTINE "GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS" JOINTLY ISSUED BY THE CHINA NATIONAL STANDARDIZATION ADMINISTRATION COMMITTEE.
ADHESION (SUITABILITY TEST): THE MASK DESIGN SHOULD PROVIDE GOOD ADHESION. THE OVERALL FIT FACTOR OF THE MASK SHOULD NOT BE LESS THAN 100. THIS TEST THE REQUIREMENTS WERE FORMALLY IMPLEMENTED ON AUGUST 1, 2011.
MASK TIGHTNESS TESTER USES CNC TECHNOLOGY, SUITABLE FOR 100 / 99 / P3 / HEPASERIES MASKS DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING DISPOSABLE DUST MASKS SUCH ASN95 / N90 / KN95), GAS MASKS / BREATHING MASKS, ADHESIVENESS TEST OF HALF-MASK AND FULL FACE MASK, INDEPENDENT OR COMPUTER CONTROL, FIVE LANGUAGES SWITCH DISPLAY, EQUIPPED WITH MULTIPLE COMMUNICATION INTERFACES (USB, ETHERNET), WIFI CAN ALSO BE ENABLED, ONE COMPUTERCAN CONTROL FOUR INSTRUMENTS AT THE SAME TIME.PARAMETER:CONCENTRATION RANGE: 0 ~ 100,000 / CM3GRAIN DIAMETER: 0.02 ~ 1.0^MFLOW: SAMPLING FLOW: 100CM3 / MINTOTAL FLOW: 700CM3 / MINCLOSENESS COEFFICIENT TEST: DIRECT TEST (COUT/ CIN)LIQUOR: 99.5% + ISOPROPANOL (ANALYTICAL GRADE)DISPLAY: 7INCH TRUE COLOR TOUCH SCREENCOMMUNICATION INTERFACE: USB X 3 (HOST X 2,DEVICE X 1) ETHERNET INTERFACE X1CONNECTION PORT: ENVIRONMENT PORT, SAMPLING PORTWIFI: EQUIPPEDLANGUAGES: ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESEFLOW CONTROL: SENSOR CONTROLPC CONTROLLABLE OPERATION: ONE COMPUTER CAN CONTROL 4 INSTRUMENTS AT THE SAME TIMEDATA OUTPUT FORMAT: MICROSOFT EXCELWORKING TEMPERATURE: 15 ~ 35 °CPOWER SOURCE: AC 110 —240V 50 / 60HZAPPEARANCE SIZE: 208 X 117 X 262MMWEIGHT: 2.1KGACCESSORIES: ALCOHOL REAGENT BOTTLE, PROTECTIVE CAP, REAGENT STICK, ZERO-COUNT FILTER, STRAINER, SAMPLING TUBE, INSTRUCTION MANUAL, AC ADAPTER, TOUCH SCREEN PEN, OPTIONAL COMPUTER.OPTIONAL: TEST KIT FOR TIGHTNESS COEFFICIENTIN ORDER TO PREVENT INFECTION AT THE MEDICAL SITE AND DURING LABOR WORK, WORKERS MUST BE PROTECTED FROM INHALABLE HAZARDOUS SUBSTANCES IN THE WORKPLACE, AND RESPIRATORS SUCH AS MASKS MUST BE WORN DURING WORK.SELECT A RESPIRATOR, SUCH AS A MASK, BASED ON YOUR FACIAL FEATURES, AND EVALUATE THE TIGHTNESS BETWEEN THE RESPIRATOR, SUCH AS A MASK AND THE FACE, TO CHECK WHETHER THERE ARE GAPS OR LEAKS THAT PUT WORKERS AT RISK. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTIVE PERFORMANCE. SECURITY EXPERTS WILL ALSO DEVELOP PROTECTION SCHEMES AND STANDARD REGULATIONS BASED ON THE RESULTS OF THE TIGHTNESS TEST. WIDELY USED IN HOSPITALS, MANUFACTURING PLANTS, PRODUCTION SITES, FIREFIGHTING WORKPLACES AND OTHER OFFICIAL TESTING AGENCIES.MASK TIGHTNESS TESTER FEATURES:• QUANTITATIVE TIGHTNESS TEST FOR RESPIRATORS SUCH AS MASKS (QNFT)• APPLICABLE TO 100/99 / P3 / HEPA SERIES MASK DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING N95 / N90 / KN95 AND OTHER DISPOSABLE DUST MASKS)• ADHESION TEST OF HALF MASK AND FULL FACE MASK• GAS MASK TIGHTNESS TEST• PAPR MASK TIGHTNESS TEST• SCBA RESPIRATOR MASK TIGHTNESS TEST• 7INCH TRUE COLOR TOUCH SCREEN• INDEPENDENT OR COMPUTER CONTROLLED• USING CNC TECHNOLOGY• ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESE LANGUAGE SWITCHING DISPLAY• COMPLIES WITH US OSHA STANDARDS, CANADIAN STANDARDS ASSOCIATION (CSA) GUIDELINES, INCLUDING N95• EQUIPPED WITH A VARIETY OF COMMUNICATION INTERFACES (USB, ETHERNET), AND CAN ALSO ENABLE WIFI• ONE COMPUTER CAN CONTROL FOUR INSTRUMENTS AT THE SAME TIMEQUANTITY: 1 - YY-1140 RESPIRATORY RESISTANCE TESTER, FLOWMETER RANGE 0 L/MIN~100L/MIN, FLOWMETER RANGE ACCURACY ±2%YY-1140 RESPIRATORY RESISTANCE TESTER, FLOWMETER RANGE 0 L/MIN~100L/MIN, FLOWMETER RANGE ACCURACY ±2% DETAILS: THE RESPIRATORY RESISTANCE TESTER IS SUITABLE FOR DETERMINING THE INHALATION RESISTANCE AND EXHALATION RESISTANCE OF RESPIRATORS AND MASK PROTECTIVE PRODUCTS UNDER SPECIFIED CONDITIONS, AND FOR THE RELATED TESTING AND INSPECTION OF COMMON MASK PRODUCTS BY MANUFACTURERS OF NATIONAL LABOR PROTECTION ARTICLE INSPECTION AGENCIES. STANDARD: GB2626-2006,GB/T32610-2016. Learn More
- J-3392 AUTOMATIC 3-PLEAT HEADBAND FISH-STYLE FACE MASK MACHINE -CAPACITY: 45 TO 50 PIECES PER MINUTE -INCLUDES PRINTING ON MASKS -INCLUDES NOSE FOAM INSERTION (CLOSED CELL FOAM)J-3392 AUTOMATIC 3-PLEAT HEADBAND FISH-STYLE FACE MASK MACHINE -CAPACITY: 45 TO 50 PIECES PER MINUTE -INCLUDES PRINTING ON MASKS -INCLUDES NOSE FOAM INSERTION (CLOSED CELL FOAM) REQUIRES 1 TO 2 OPERATORS WITH PLC CONTROLS WEIGHT: 1600 KGS VOLTAGE: 220 VOLTS POWER: 6 KW ULTRASONIC FREQUENCY: 20 kHz GAS PRESSURE: 6 KG PER cm2 QUANTITY: 1 Learn More
- YY-1170 FACE MASK PACKING MACHINEYY-1170 FACE MASK PACKING MACHINE TYPE: MULTI-FUNCTION PILLOW PACKAGING MACHINE. FUNCTION: FILLING, LABELING, SEALING, WRAPPING BAG FORMATS: PILLOW BAG, FLAT BOTTOM BAG, 3/4 SIDES SEALING BAG, ETC. BAG WIDTH: 30 TO 110mm PRODUCT HEIGHT: MAX 40mm SPEED: 80 TO 120BAG/MIN VOLTAGE AND POWER: 220V/2.4KW DIMENSION (L X W X H): (L)3000 X (W)1350 X (H)1430mm MACHINE WEIGHT: ABOUT 300KG QUANTITY: 1 Learn More