Search results for: 'machine can'
- Related search terms
- Machine c
- machine'''
- Machine+c'
- machine''''
- machine'''''
- M-5145 ROUND ABSORBENT COTTON PAD PRODUCTION MACHINEREFERENCE NUMBER: M-5145 (1212TJGBXX11) L ROUND ABSORBENT COTTON PAD PRODUCTION MACHINE ROUND COTTON PAD MACHINE IS USED TO PRODUCE THE COSMETIC COTTON PAD OR MAKE-UP REMOVER PAD ALL PROCESSES ARE FULLY AUTOMATIC, FROM RAW MATERIAL FEEDING, CONVEYING, EMBOSSING, PUNCHING TO FINAL PRODUCTS THE EMBOSSING DESIGN AND COTTON PAD SIZE CAN BE CUSTOMIZED AUTOMATIC COUNTING FUNCTION SAVES LABOR COST AND TIME MODEL: C8 RAW MATERIALS: COTTON PAD ROLL POWER SUPPLY: 380V, 50/60HZ POWER CONSUMPTION: 3.0KW AIR SUPPLY: 0.6 ~ 0.8 MPA PRODUCTION SPEED: 20 TO 30 METERS PER MINUTE MACHINE DIMENSION: (L3500 x W1700 x H2500) mm GROSS WEIGHT: 1000KG LABOR REQUIRED: 1 PRODUCTION AREA REQUIRED: ABOUT 15M2 QUANTITY: 1 Learn More
- M-5144 SQUARE ABSORBENT COTTON PAD PRODUCTION MACHINEREFERENCE NUMBER: M-5144 (1212HNBGXX11) L SQUARE ABSORBENT COTTON PAD PRODUCTION MACHINE SQUARE COTTON PAD MACHINE IS USED TO PRODUCE THE COSMETIC COTTON PAD OR MAKE-UP REMOVER PAD ALL PROCESSES ARE FULLY AUTOMATIC, FROM RAW MATERIAL FEEDING, CONVEYING, EMBOSSING, VERTICAL CUTTING, HORIZONTAL CUTTING, TO FINAL PRODUCTS THE EMBOSSING DESIGN AND COTTON PAD SIZE CAN BE CUSTOMIZED AUTOMATIC COUNTING FUNCTION SAVES LABOR COST AND TIME MODEL: C7 RAW MATERIALS: COTTON PAD ROLL POWER SUPPLY: 380V, 50/60HZ POWER CONSUMPTION: 3.0KW AIR SUPPLY: N/A PRODUCTION SPEED: 1000 TO 1800 PIECES PER MINUTE MACHINE DIMENSION: (L2100 x W1700 x H1500) mm GROSS WEIGHT: 1100KG LABOR REQUIRED: 1 PRODUCTION AREA REQUIRED: ABOUT 15M2 QUANTITY: 1 Learn More
- M-5146 ROUND COTTON PADS MAKING MACHINEREFERENCE NUMBER: M-5146 (1212KKBCXX11) L ROUND COTTON PADS MAKING MACHINE AUTOMATIC ROUND MAKE UP COTTON PADS MACHINE RAW MATERIAL ROLL AUTOMATIC DELIVER EMBOSSING CUTTING OUTPUT IN ARRANGEMENT WASTE MATERIAL ROLLING AUTOMATIC COUNTING FROM LOADING THE RAW MATERIAL TO FINISHED PRODUCT, ALL AUTOMATIC MECHANICAL DRIVE CUTTING, RUNNING STABILITY, EFFICIENCY CAN MAKE FLAT COTTON PADS AND EMBOSSING COTTON PADS MODEL: HZM-1 PRODUCT DIAMETER: 58mm OR ACCORDING TO CUSTOMER RAW MATERIAL: ABSORBENT COTTON, NON-WOVEN FABRICS WEIGHT: 2300KG VOLTAGE: AC 380V 50/60HZ POWER: 5.5KW CAPACITY 400 PIECES PER MINUTE DIMENSION: 5000x1000x2000mm QUANTITY: 1 Learn More
- M-5143 ROUND COTTON PAD MAKING MACHINEREFERENCE NUMBER: M-5143 (1212YJJGXX11) L ROUND COTTON PAD MAKING MACHINE NONWOVEN ROUND COTTON PAD MAKING MACHINE MODEL: RD MATERIAL WIDTH: 95CM; DIAMETER: 70CM SLITTING DEVICE: DERANGEMENT PERMUTATION ROUND MOULD PUNCHING EMBOSSING DEVICE: STEEL ROLL EMBOSSING, THE EMBOSSING PATTERN CAN BE CUSTOMIZED PRODUCT SIZE: CUSTOMIZED COUNTING WAY: LEFT AND RIGHT COUNTING SLITTING MATERIAL: COTTON, NONWOVEN, COTTON COMPOSITION MATERIAL PRODUCT FEATURE: EDGE OPEN OR NOT CONTROL SYSTEM: PLC SERVO CONTROL OF MOTOR SPEED MOTOR: SERVO MOTOR PARAMETER-SETTING: COLOR TOUCH SCREEN PRODUCTION SPEED: 400 PIECES PER MINUTE AIR COMPRESSOR: PROVIDED BY YOURSELF PACKING SIZE: DEPENDING ON THE CONFIGURATION POWER: 380V / 50HZ / 5.5KW WEIGHT: ABOUT 2300KG DEPENDING ON THE CONFIGURATION QUANTITY: 1 Learn More
- T-6543 MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
REFERENCE NUMBER: T-6543
MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
SHANDONG INDEPENDENTLY RESEARCH AND DEVELOPMENT THIS COMPREHENSIVE TESTING MACHINE FOR SURGICAL MASK & PROTECTIVE CLOTHING, IT IS WIDELY USED IN A VARIETY OF MASK STRENGTH DETECTION PROJECTS.FEATURES:COMPLY WITH NATIONAL STANDARDS, MEDICAL STANDARDS TESTING REQUIREMENTS, AUTOMATIC SOFTWARE CONTROL SYSTEM, MEET THE REQUIREMENTS OF DATA STORAGE, PRINTING, COMPARISON. THE IMPORTED SERVO MOTOR IS EQUIPPED WITH PRECISION SCREW DRIVE SYSTEM TO ENSURE THE STABILITY OF TEST DATA.
TEST STANDARDS:
GB 19082-2009 TECHNICAL REQUIREMENTS FOR DISPOSABLE PROTECTIVE CLOTHING FOR MEDICAL USE (4.5 BREAKING STRENGTH -THE BREAKING STRENGTH OF MATERIALS IN KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 45N)
(4.6 ELONGATION AT BREAK -THE ELONGATION AT BREAK OF KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 15%)
SELF-PRIMING FILTER RESPIRATOR FOR RESPIRATORY PROTECTION ARTICLES5.6.2 BREATHING BONNET -BREATHING BONNET SHALL BE SUBJECT TO AXIAL TENSION"DISPOSABLE MASK: 10N FOR 10S" "REPLACEABLE MASK: 50N FOR 10S"
(5.9 HEADBAND -HEADBAND SHOULD BEAR THE TENSION "DISPOSABLE MASK: 10N, 10S" "REPLACEABLE HALF MASK: 50N FOR 10S" "FULL MASK: 150N FOR 10S")
5.10 JOINTS AND CONNECTING PARTS -JOINTS AND CONNECTING PARTS SHALL BE SUBJECT TO AXIAL TENSION
"REPLACEABLE HALF MASK: 50N FOR 10S" "FULL COVER 250N FOR 10S"
GB/T 32610-2016 TECHNICAL SPECIFICATION FOR DAILY PROTECTIVE MASKS
(6.9 BREAKING STRENGTH OF THE MASK BELT AND THE CONNECTION BETWEEN THE MASK BELT ANDTHE MASK BODY ≥ 20N)
(6.10 FASTNESS TO BREATHING BONNET: NO SLIPPAGE, BREAKAGE OR DEFORMATION SHALL OCCUR)
YY/T 0699-2013 DISPOSABLE SURGICAL MASK
(4.4 MASK BELT -THE BREAKING FORCE AT THE CONNECTION POINT BETWEEN EACH MASK BELT AND THE MASK BODY IS NOT LESS THAN 10N)
YY 0469-2011 SURGICAL MASK FOR MEDICAL USE (5.4.2 MASK BELT)
GB/T 3923.1-1997 DETERMINATION OF BREAKING STRENGTH AND ELONGATION AT BREAK OF FABRICS (STRIP METHOD)
DISPOSABLE RUBBER INSPECTION GLOVES (6.3 TENSILE PROPERTIES)
INSTRUMENT TECHNICAL PARAMETERS:
SPECIFICATION: 200N (STANDARD) 50N, 100N, 500N, 1000N (OPTIONAL)
ACCURACY: BETTER THAN 0.5RESOLUTION OF FORCE VALUE: 0.1N
DEFORMATION RESOLUTION: 0.001mm
TEST SPEED: 0.01mm/MIN ~ 2000mm/MIN (STEPLESS SPEED REGULATION)
WIDTH OF SAMPLE: 30mm (STANDARD FIXTURE) 50mm (OPTIONAL FIXTURE)
CLAMPING OF SAMPLES: MANUAL (PNEUMATIC CLAMPING CAN BE CHANGED)
STROKE: 700mm (STANDARD) 400mm, 1000mm (OPTIONAL)
QUANTITY: 1
Learn More - T-6546 PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKREFERENCE NUMBER: T-6546PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKINTRODUCTIONMEDICAL SURGICAL MASK PARTICLE FILTRATION EFFICIENCY PFE TESTER IS SUITABLE FOR MEDICAL INSTRUMENT INSPECTION CENTER, SAFETY PROTECTION INSPECTION CENTER, LABOR PROTECTION INSPECTION CENTER, DRUG INSPECTION CENTER, DISEASE PREVENTION AND CONTROL CENTER, TEXTILE INSPECTION CENTER, HOSPITAL, MASK AND RESPIRATOR MANUFACTURERS, ETC.FEATURESTHE PFE TESTER FOR PARTICLE FILTRATION EFFICIENCY OF SURGICAL MASKS IS EQUIPPED WITH A SPECIAL SALT AEROSOL GENERATOR, WHICH CAN PRODUCE AEROSOLS WITH SPECIFIC PARTICLE SIZE AND CONCENTRATION.EQUIPPED WITH A SERIES OF SPECIAL FIXTURE, SUITABLE FOR THE DETECTION OF ALL KINDS OF MASKS.BUILT-IN HIGH LIFE PHOTOMETER MODULE, SAMPLING TIME ACCUMULATION, PROMPT LIGHT CLEANING.AUTOMATIC CONTROL OF AEROSOL GENERATION, AUTOMATIC CALCULATION OF CAPTURE EFFICIENCY AND MASK AIRFLOW RESISTANCE, REDUCE HUMAN INTERVENTION.BUILT-IN HIGH PRECISION ELECTRONIC FLOWMETER AND HIGH PERFORMANCE SAMPLING PUMP TO ENSURE FLOW STABILITY.PARAMETERTEST FLOW: PARAMETER RANGE: (5 ~ 100) L/MIN; RESOLUTION: (5 ~ 100) L/MIN;MAXIMUM ALLOWABLE ERROR: ±1%PRESSURE DETECTION RANGE: PARAMETER RANGE: (0 ~ 2500) PA; RESOLUTION: 0.1PA; MAXIMUM ALLOWABLE ERROR: ±1%CONCENTRATION DETECTION RANGE: PARAMETER RANGE: (0.001 ~ 100) 0 G/L;DETECTION ACCURACY: 1% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100%DETECTION REPEATABILITY: 5% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100% MEDIAN DIAMETER OF SALT AEROSOL PARTICLES (CMD): (0.075±0.02)MMEDIAN AEROSOL PARTICLE NUMBER DIAMETER (CMD) (OPTIONAL): (0.185±0.02) MOPERATING TEMPERATURE: 20±5CINSTRUMENT NOISE: <60DB(A)POWER SUPPLY: AC220V±10%, 50HZMAIN MACHINE SIZE: (LENGTH 700 X WIDTH 720 X HEIGHT 1450) mmQUANTITY: 1