Search results for: 'Machine op'
- Related search terms
- machine tr
- Machine car
- machine''[0]'[0]
- Machine+op
- Machine fe
- T-6546 PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKREFERENCE NUMBER: T-6546PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKINTRODUCTIONMEDICAL SURGICAL MASK PARTICLE FILTRATION EFFICIENCY PFE TESTER IS SUITABLE FOR MEDICAL INSTRUMENT INSPECTION CENTER, SAFETY PROTECTION INSPECTION CENTER, LABOR PROTECTION INSPECTION CENTER, DRUG INSPECTION CENTER, DISEASE PREVENTION AND CONTROL CENTER, TEXTILE INSPECTION CENTER, HOSPITAL, MASK AND RESPIRATOR MANUFACTURERS, ETC.FEATURESTHE PFE TESTER FOR PARTICLE FILTRATION EFFICIENCY OF SURGICAL MASKS IS EQUIPPED WITH A SPECIAL SALT AEROSOL GENERATOR, WHICH CAN PRODUCE AEROSOLS WITH SPECIFIC PARTICLE SIZE AND CONCENTRATION.EQUIPPED WITH A SERIES OF SPECIAL FIXTURE, SUITABLE FOR THE DETECTION OF ALL KINDS OF MASKS.BUILT-IN HIGH LIFE PHOTOMETER MODULE, SAMPLING TIME ACCUMULATION, PROMPT LIGHT CLEANING.AUTOMATIC CONTROL OF AEROSOL GENERATION, AUTOMATIC CALCULATION OF CAPTURE EFFICIENCY AND MASK AIRFLOW RESISTANCE, REDUCE HUMAN INTERVENTION.BUILT-IN HIGH PRECISION ELECTRONIC FLOWMETER AND HIGH PERFORMANCE SAMPLING PUMP TO ENSURE FLOW STABILITY.PARAMETERTEST FLOW: PARAMETER RANGE: (5 ~ 100) L/MIN; RESOLUTION: (5 ~ 100) L/MIN;MAXIMUM ALLOWABLE ERROR: ±1%PRESSURE DETECTION RANGE: PARAMETER RANGE: (0 ~ 2500) PA; RESOLUTION: 0.1PA; MAXIMUM ALLOWABLE ERROR: ±1%CONCENTRATION DETECTION RANGE: PARAMETER RANGE: (0.001 ~ 100) 0 G/L;DETECTION ACCURACY: 1% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100%DETECTION REPEATABILITY: 5% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100% MEDIAN DIAMETER OF SALT AEROSOL PARTICLES (CMD): (0.075±0.02)MMEDIAN AEROSOL PARTICLE NUMBER DIAMETER (CMD) (OPTIONAL): (0.185±0.02) MOPERATING TEMPERATURE: 20±5CINSTRUMENT NOISE: <60DB(A)POWER SUPPLY: AC220V±10%, 50HZMAIN MACHINE SIZE: (LENGTH 700 X WIDTH 720 X HEIGHT 1450) mmQUANTITY: 1
- T-6550 MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTER
REFERENCE NUMBER: T-6550
MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTER
TECHNICAL SPECIFICATIONS AND CONFIGURATION:
1. THE INSTRUMENT ADOPTS AN AIR SOURCE THAT CAN PROVIDE (0.5 ~ 30±0.1) KPA PRESSURE TO CONTINUOUSLY PRESSURIZED THE SAMPLE, WHICH IS NOT RESTRICTED BY THE SPACE OF THE TEST SITE;
2. THE AIR PRESSURE RANGE CAN BE ADJUSTED FREELY, AND THE ADJUSTMENT RANGE (0.5 ~ 30) KPA;
3. COLOR TOUCH SCREEN DISPLAY AND OPERATION;
4. THE SAMPLE CLAMPING PAD IS PROCESSED WITH IMPORTED SPECIAL ALUMINUM PROFILES, WHICH IS LIGHT IN MATERIAL, CLEAN IN SURFACE AND NEVER RUSTS.
5. THE INSTRUMENT ADOPTS IMPORTED SPECIAL ALUMINUM WIRE DRAWING PANEL, EQUIPPED WITH METAL KEYS, SENSITIVE OPERATION, NOT EASY TO DAMAGE;
6. CLAMPING DEVICE FOR INSTRUMENT SAMPLES, EQUIPPED WITH LOCKING PROTECTION, TO PREVENT THE SYNTHETIC BLOOD FROM SPLASHING AROUND;
7. CLAMPING FORCE IS ACCURATE AND RELIABLE;
8. THE TEST TANK IS EQUIPPED WITH A SPECIAL PLACEMENT DEVICE, WHICH IS CONVENIENT FOR CUSTOMERS TO OPERATE;
9. THE TEST TANK IS PROCESSED WITH SPECIAL 316 STAINLESS STEEL, AND THE TOP IS EQUIPPED WITH A SPECIAL COVER FOR HIGH TRANSPARENT PROTECTION;
10. THE WASHER BELOW THE SAMPLE IS MADE OF HIGH-QUALITY PTFE MATERIAL AFTER SPECIAL PROCESSING;
11. SQUARE METAL BLOCK NET: OPEN SPACE ≥50°%; BENDING ≤5mm AT 30KPA;
12. INSTRUMENT TIME CONTROL ACCURACY ≤01 SECONDS;
13. THE SHELL OF THE INSTRUMENT IS MADE OF HIGH-QUALITY METAL BAKING PAINT, WHICH IS BEAUTIFUL AND GENEROUS.
14. EQUIPPED WITH PRINTER INTERFACE, CONNECTED TO THE PRINTER CAN DIRECTLY PRINT DATA REPORTS.
TECHNICAL PARAMETERS:
1. SAMPLE SIZE: 75mm X 75mm
2. TEST AREA: 28.26 SQUARE CENTIMETERS
3. AIR PRESSURE ADJUSTMENT RANGE (0.5 ~ 30) KPA
4. EXTERNAL SIZE: 500mm X 500mm X 500mm (L X W X H)
5. WEIGHT OF THE INSTRUMENT: 40 KG
6. POWER SUPPLY: AC220V, 50HZ,SCOPE OF SUPPLY: 1. ONE MAIN MACHINE; 2. TWO PTFE GASKETS; 3. TWO ORDINARY WASHERS; 4. ONE METAL BLOCKING NET; 5. A SET OF SPECIAL LOCKING TOOLS; 6. ONE HIGH-QUALITY SILENT AIR PUMP, [NOTE: SAFETY PRODUCTION LICENSE IS NOT INCLUDED]. 7. EQUIPPED WITH PRINTER INTERFACE; 8. ONE SAMPLE TEMPLATE; 9. ONE PRODUCT CERTIFICATE; 10. ONE COPY OF PRODUCT OPERATION MANUAL.
OPERATION INSTRUCTION:
INSERT THE AIR PUMP OUTPUT PIPE INTO THE OIL AND WATER SEPARATOR OF THE INSTRUMENT AS REQUIRED (PRESSURE 0.1-0.3MPA).
AFTER SWITCHING ON THE POWER, THE STARTUP INTERFACE (NAME OF THE DEVICE) IS DISPLAYED.
PRESS THE "ENTER" BUTTON TO ENTER THE TEST INTERFACE, AS SHOWN IN THE FOLLOWING FIGURE:
CLICK "SETTING” BUTTON, GET INTO PARAMETER SETTING SCREEN, AS BELOW THIS SCREEN CAN SET THE SYSTEM TIME, DATE AND TESTING TIME, AFTER SETTING, CLICK "SAVE” BUTTON TO KEEP THE SETTING DATA. (NOTE: IT REQUIRES 5 MINUTES IN THE STANDARD)
QUANTITY: 1
Learn More - T-6575 NON-INVASIVE VENTILATOR
NON-INVASIVE VENTILATOR
Learn More
CERTIFICATE: CE
MEDICAL VENTILATOR
TECHNICAL PARAMETERS OF DOUBLE LEVEL VENTILATOR
VENTILATOR TYPE: ELECTRIC CONTROL
SCOPE OF APPLICATION: TREATMENT AND TITRATION OF SLEEP APNEA HYPOPNEA SYNDROME, SEVERE SNORING, AND RESPIRATORY INSUFFICIENCY.
DISPLAY INTERFACE: 3.5-INCH LED SCREEN, CHINESE OPERATING SYSTEM
*VENTILATION MODE: CPAP, S, S/T, T
PRESSURE RANGE:
PRESSURE RANGE: 4-30CMH2O (±0.5CMH2O)
PRESSURE ACCURACY: + 0.5CMH2O
PARAMETER SETTING:
DELAYED BOOST: 0-60MIN, SET THE DIVISION INTERVAL 5MIN
INITIAL PRESSURE: 4CMH2O TREATMENT PRESSURE / RESPIRATORY PRESSURE SETTING
THERAPEUTIC PRESSURE: 4-20CMH2O (IN CPAP MODE)
TARGET TIDAL VOLUME: 150ML - 1500ML, ON/ OFF
MAXIMUM SUCTION PRESSURE: 4-30CMH2O, (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
MINIMUM SUCTION PRESSURE: 4-30CMH2O (NOT HIGHER THAN THE SUCTION PRESSURE), (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
INSPIRATORY PHASE PRESSURE: 4-30CMH2O
EXPIRATORY PRESSURE: 4-30CMH2O
EXPIRATORY DECOMPRESSION: PATIENT, OFF, 1-3, THREE ADJUSTABLE
MANUAL VOLTAGE REGULATION: 0-2 GEAR, 0-2CMH2O (ONLY AVAILABLE IN CPAP MODE)
INSPIRATORY SENSITIVITY: 1-8 STALLS
EXPIRATORY SENSITIVITY: 1-8 STALLS
RESPIRATORY FREQUENCY: 3-40 TIMES / MIN
INSPIRATORY TIME: 0.3-3.0S
BACKUP RATE: ON / OFF, DEFAULT 10
PRESSURE RISE TIME: 1-4 STALLS
HUMIDIFIER: 1-5 ADJUSTABLE IN 5 GEARS
*TITRATION FUNCTION: SUPPORT MANUAL AND AUTOMATIC PRESSURE TITRATION, BUILT-IN REMOTE WIRELESS COMMUNICATION MODULE, COMPLETE THE RANDOM SWITCHING OF SINGLE AND DOUBLE LEVEL MODES IN THE TITRATION PROCESS, AND CONTROL MORE THAN 11 VENTILATOR PARAMETERS AT THE SAME TIME.
AUXILIARY FUNCTION: AUTOMATIC AIR LEAKAGE COMPENSATION, AUTOMATIC STARTUP, AUTOMATIC SHUTDOWN, DELAYED SHUTDOWN, SCREEN BACKLIGHT ADJUSTMENT
MONITORING PARAMETERS: PRESSURE, TIDAL VOLUME, RESPIRATORY RATE, MINUTE VENTILATION VOLUME, AIR LEAKAGE VOLUME, INSPIRATORY TIME, BLOOD OXYGEN SATURATION
WAVY CURVE: PRESSURE TIME WAVEFORM, FLOW RATE TIME WAVEFORM
ALARM PROMPT: PIPELINE AND MASK FALLING OFF, AIR LEAKAGE PROMPT, POWER INTERRUPTION, TREATMENT MACHINE FAILURE, HUMIDIFIER FAILURE, LOW VOLTAGE, HIGH RESPIRATORY RATE, LOW RESPIRATORY RATE, LOW MINUTE VENTILATION VOLUME, LOW BLOOD OXYGEN, REPLACEMENT OF FILTER COTTON, FULL SD CARD, RE INSERTION OF SD CARD
*DATA MANAGEMENT:
NETWORK DATA: BMC + RESPIRATORY HEALTH MANAGEMENT CLOUD PLATFORM
SD CARD DATA: RESART NPAP DATA ANALYSIS SOFTWARE
PARTS:
SD CARD: STANDARD
SD CARD SLOT: STANDARD
PIPING: 9 22MM, 1.8M LONG
FACE SHIELD: F2 NOSE MASK AS STANDARD
NOISE: LESS THAN 30DB
ENVIRONMENT CONDITION:
TEMPERATURE:
(WHEN USED) 5 -35 C
(DURING TRANSPORTATION AND STORAGE) -20 C -55 C
ATMOSPHERIC PRESSURE:
(WHEN USED) 760-1060HPA
(DURING TRANSPORTATION AND STORAGE) 760-1060HPA
WORKING HOURS: MORE THAN 8 HOURS
POWER SUPPLY REQUIREMENTS:
AC VOLTAGE: 100-240V
FREQUENCY: 50HZ/60HZ
INPUT POWER: LESS THAN 2A
WATERPROOF LEVEL: IP22 - DRIP PROOF EQUIPMENT
INSTRUMENT SIZE: 290mm X 180mm X 134mm
WEIGHT: 1.5KG (EXCLUDING HUMIDIFIER) 2.5KG (INCLUDING HUMIDIFIER)
ITEM 001
QUANTITY: 10 SETS-999 SETS
ITEM 002
QUANTITY: 1,000 SETS-9,999SETS
ITEM 003
QUANTITY: ≥10,000 SETS - J-2778 SEMI-AUTOMATIC FACE MASK MACHINE FOR MASS 175 x 95mm – 200 PER MINUTE (Air Freight Available)
SEMI-AUTOMATIC FACE MASK MACHINE
PRODUCES BLANK MASKS WITH NO EAR STRAPS (see our J-2779 for ear strap machine)
MASK DIMENSIONS: 175 x 95mm
CAPACITY: 150 TO 200 PIECES PER MINUTE
WEIGHT: 650 KGS
DIMENSIONS (L x W x H): 3400 x 800 x 2020mm
MATERIAL: NONWOVEN/ MELT-BLOWN FABRIC
VOLTAGE: 220 VOLTS / 380 VOLTS
POWER: 6 KWWITH ADJUSTABLE SPEED
CONSISTENT PRODUCT QUALITY
CONVENIENT OPERATION
USES ULTRASONIC WELDING TO FORM MASKSLEAD TIME: 5 DAYS FROM RECEIPT OF PAYMENT
PACKAGE 1 BY WOODEN BOX: 2400 X 1000 X 1300mm
Learn More
PACKAGE 2 BY WOODEN BOX: 2150 X 700 X 2300 mm
TOTAL WEIGHT IS EXPECTED TO BE AROUND 650KGS - V-1471 AUTOMATIC CORELESS ROLL WINDER
REFERENCE NUMBER: V-1471
AUTOMATIC CORELESS ROLL WINDER
THE MACHINE IS SUITABLE TO PROCESS CORELESS ELASTIC BANDAGE ROLLS.
HAS PRE-FEEDING SYSTEM, TO ENSURE NO DAMAGE TO THE ELASTICITY (OPTIONAL).
WITH AUTOMATIC WINDING, COUNTING, CUTTING, AND OUTPUT SYSTEM.
TOUCH SCREEN IS CONTROLLED BY PLC PROGRAM SYSTEM.
WORKING SPEED: 7 TO 11 BEATS PER MINUTE
END SURFACE TOLERANCE OF FINAL ROLLS (DEPENDS ON MATERIAL): ±2 TO 3.5mm
ROLLING TENSION: ADJUSTABLE
MAX. DIAMETER OF FINISHED BANDAGE: 6cm
QUANTITY: 1
Learn More