V-1467 3 SIDE MEDICAL BANDAGES PACKAGING MACHINEREFERENCE NUMBER: V-1467
3 SIDE MEDICAL BANDAGES PACKAGING MACHINE
THIS MACHINE IS SUITABLE TO PACK MEDICAL BANDAGES, MEDICINE, FOOD, COMMODITY, ETC.
INCLUDES:
SPECIAL POUCH ADJUSTING SYSTEM, GOOD FOR PACKING PRODUCTS WITH MULTIFORM SIZE, MULTIFORM SPECIFICATION.
COMPUTER CONTROL SYSTEM.
SPECIAL IN-FEED SYSTEM, IN –FEED POSITION CAN BE ADJUSTED DURING MACHINE OPERATION.
SLIPPAGE SEALING SYSTEM CAN ADJUST
PACKAGING FILM THICKNESS: 0.03 TO 0.08mm
SPEED: 40 TO 220 POUCHES PER MINUTE
PACKAGING FILM WIDTH: 100 TO 350mm
FIGURATION (APPROXIMATE): 4350 (L) X 1050 (W) X 1600 (H)
POWER: 3.2 KW
WEIGHT (APPROXIMATE): 500KG
SIZE OF POUCH: ADJUSTABLE, PER CUSTOMER.
QUANTITY: 1
Learn More -
M-5188 COTTON PAD MAKING MACHINE (500 PCS/MIN)REFERENCE NUMBER: M-5188 (1313211JK12UF) L COTTON PAD MAKING MACHINE (500 PCS/MIN) COTTON PAD MAKING MACHINE MODEL: ZM500 PRODUCTION SPEED: 500 PIECES PER MINUTE DIMENSIONS (LxWxH): 5000mm x 1000mm x 2000mm QUANTITY AVAILABLE: 1 Learn More -
M-5170 COTTON BALL MAKING MACHINE (NEW)REFERENCE NUMBER: M-5170 (131352ZD12UX) L COTTON BALL MAKING MACHINE (NEW) MODEL: MQ50 QUANTITY AVAILABLE: 1 Learn More -
M-5141 COTTON PAD PRODUCTION MACHINEREFERENCE NUMBER: M-5141 (1212TTPCXX11) L COTTON PAD PRODUCTION MACHINE COTTON PAD SLICES CUTTING MACHINE MODEL: RC RAW MATERIAL WIDTH: 95CM; DIAMETER: 70CM SLITTING DEVICE: SHEAR TYPE ROUND KNIVES EMBOSSING DEVICE: STEEL ROLL EMBOSSING, THE PATTERN CAN BE CUSTOMIZED PRODUCT SIZE: WIDTH DEPENDS ON THE MOULD AND THE LENGTH CAN BE ADJUSTED WITHIN 10CM FREELY COUNTING WAY: LEFT AND RIGHT COUNTING SLITTING MATERIAL: COTTON, NONWOVEN, COTTON COMPOSITES PRODUCT FEATURE: EDGE OPEN OR NOT CONTROL SYSTEM: FREQUENCY CONTROL OF MOTOR SPEED MOTOR: STEPPING MOTOR PARAMETER-SETTING: MAN-MACHINE INTERFACE PRODUCTION SPEED: 300 TO 1600 PIECES PER MINUTE AIR COMPRESSOR: PROVIDED BY YOURSELF PACKING SIZE: DEPENDING ON THE CONFIGURATION POWER: 380V / 50HZ / 4.5KW WEIGHT: ABOUT 1800KG DEPENDING ON THE CONFIGURATION QUANTITY: 1 Learn More -
AA-1153 MASK FILM PACKING MACHINE, UP TO 110 MASKS PER MINUTEAA-1153 MASK FILM PACKING MACHINE, UP TO 110 MASKS PER MINUTE 1. MAXIMUM PRODUCT LENGTH: 220mm 2. MAXIMUM PRODUCT WIDTH: 120mm 3. PACKAGING PRODUCT HEIGHT: 45mm 4. PACKING SPEED: 30 TO 110 BAGS PER MINUTE 5. PACKAGING FILM MAXIMUM WIDTH: 440mm 6. WEIGHT: 900 KGS QUANTITY: 1 Learn More -
VJ-1116 FULLY AUTOMATIC FLAT FACE MASK PRODUCTION LINE, 300 MASKS PER MINUTEVJ-1116 FULLY AUTOMATIC FLAT FACE MASK PRODUCTION LINE, 300 MASKS PER MINUTE MASK BODY PRODUCTION WITH AUTOMATIC FEEDING TO EAR LOOP WELDING FOR COMPLETE, AUTOMATED PRODUCTION MASK TYPE: SURGICAL, FLAT MASK WITH EAR LOOPS MASK DIMENSIONS: 175 x 95mm CAPACITY: 250 TO 300 PIECES PER MINUTE (FINISHED PRODUCT) NONWOVEN MATERIAL: SPUNBONDED AND MELT-BLOWN FABRIC QUANTITY: 1 Learn More -
MEDICAL FACE MASK AIR EXCHANGE DIFFERENTIAL PRESSURE TESTER, 60HzREFERENCE NUMBER: T-6870 MEDICAL FACE MASK AIR EXCHANGE DIFFERENTIAL PRESSURE TESTER, 60Hz MEDICAL FACE MASKS AIR EXCHANGE DIFFERENTIAL PRESSURE TESTER IS SUITABLE FOR DETERMINING THE AIR EXCHANGE DIFFERENTIAL PRESSURE OF MEDICAL FACE MASKS. IT CAN ALSO BE USED FOR THE DETERMINATION OF OTHER TEXTILE MATERIALS. STANDARDS: EN 14683-2014 ASTM F2100-2019 YY 0469-2011 YY 0969-2013 FEATURES: EQUIPPED WITH HIGH PRECISION DIFFERENTIAL PRESSURE SENSOR, DIGITAL DISPLAY OF THE DIFFERENTIAL PRESSURE OF BOTH SIDES OF THE SPECIMEN; SPECIAL SAMPLE HOLDERS TO ENSURE CLAMP THE SPECIMEN FIRMLY. KEY SPECIFICATION: AIR SOURCE: SUCTION TYPE AIRFLOW: 8L/MIN SEALING METHOD: END FACE SEAL DIAMETER OF TEST AREA: Ф25mm RANGE OF DIFFERENTIAL PRESSURE SENSOR: 0 TO 500PA DISPLAY METHOD: DIGITAL DISPLAY OF THE DIFFERENTIAL PRESSURE POWER SUPPLY: AC220V, 60Hz QUANTITY: 1 SET Learn More -
T-6546 PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKREFERENCE NUMBER: T-6546PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKINTRODUCTIONMEDICAL SURGICAL MASK PARTICLE FILTRATION EFFICIENCY PFE TESTER IS SUITABLE FOR MEDICAL INSTRUMENT INSPECTION CENTER, SAFETY PROTECTION INSPECTION CENTER, LABOR PROTECTION INSPECTION CENTER, DRUG INSPECTION CENTER, DISEASE PREVENTION AND CONTROL CENTER, TEXTILE INSPECTION CENTER, HOSPITAL, MASK AND RESPIRATOR MANUFACTURERS, ETC.FEATURESTHE PFE TESTER FOR PARTICLE FILTRATION EFFICIENCY OF SURGICAL MASKS IS EQUIPPED WITH A SPECIAL SALT AEROSOL GENERATOR, WHICH CAN PRODUCE AEROSOLS WITH SPECIFIC PARTICLE SIZE AND CONCENTRATION.EQUIPPED WITH A SERIES OF SPECIAL FIXTURE, SUITABLE FOR THE DETECTION OF ALL KINDS OF MASKS.BUILT-IN HIGH LIFE PHOTOMETER MODULE, SAMPLING TIME ACCUMULATION, PROMPT LIGHT CLEANING.AUTOMATIC CONTROL OF AEROSOL GENERATION, AUTOMATIC CALCULATION OF CAPTURE EFFICIENCY AND MASK AIRFLOW RESISTANCE, REDUCE HUMAN INTERVENTION.BUILT-IN HIGH PRECISION ELECTRONIC FLOWMETER AND HIGH PERFORMANCE SAMPLING PUMP TO ENSURE FLOW STABILITY.PARAMETERTEST FLOW: PARAMETER RANGE: (5 ~ 100) L/MIN; RESOLUTION: (5 ~ 100) L/MIN;MAXIMUM ALLOWABLE ERROR: ±1%PRESSURE DETECTION RANGE: PARAMETER RANGE: (0 ~ 2500) PA; RESOLUTION: 0.1PA; MAXIMUM ALLOWABLE ERROR: ±1%CONCENTRATION DETECTION RANGE: PARAMETER RANGE: (0.001 ~ 100) 0 G/L;DETECTION ACCURACY: 1% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100%DETECTION REPEATABILITY: 5% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100% MEDIAN DIAMETER OF SALT AEROSOL PARTICLES (CMD): (0.075±0.02)MMEDIAN AEROSOL PARTICLE NUMBER DIAMETER (CMD) (OPTIONAL): (0.185±0.02) MOPERATING TEMPERATURE: 20±5CLearn MoreINSTRUMENT NOISE: <60DB(A)POWER SUPPLY: AC220V±10%, 50HZMAIN MACHINE SIZE: (LENGTH 700 X WIDTH 720 X HEIGHT 1450) mmQUANTITY: 1 -
T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKSREFERENCE NUMBER: T-6547
RESPIRATOR RESISTANCE TESTER FOR FACE MASKS
INTRODUCTION
THE RESPIRATOR RESISTANCE TESTER IS USED TO MEASURE THE INSPIRATORY RESISTANCE AND EXPIRATORY RESISTANCE OF RESPIRATORS AND RESPIRATOR PROTECTORS UNDER SPECIFIED CONDITIONS. IT IS APPLICABLE TO THE NATIONAL LABOR PROTECTION EQUIPMENT INSPECTION INSTITUTIONS, MASK MANUFACTURERS FOR THE GENERAL MASKS, DUST MASKS, MEDICAL MASKS, ANTI-SMOG MASKS PRODUCTS OF THE RELEVANT TESTING AND INSPECTION.
STANDARD
GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS
GB 2626-2006 RESPIRATOR SELF-SUCTION FILTER RESPIRATOR AGAINST PARTICULATE MATTER
GB/T 32610-2016 TECHNICAL SPECIFICATIONS FOR DAILY PROTECTIVE MASKS
FEATURES:
1. HIGH-DEFINITION LCD DISPLAY.
2. DIGITAL DIFFERENTIAL PRESSURE METER WITH HIGH PRECISION IMPORTED BRAND.
3. HIGH PRECISION IMPORTED BRAND OF DIGITAL FLOWMETER, WITH HIGH FLOW CONTROL ACCURACY FEATURES.
4. THE RESPIRATOR RESISTANCE TESTER CAN SET UP TWO MODES: EXHALATION DETECTION AND INHALATION DETECTION.
5. AUTOMATIC PIPELINE SWITCHING DEVICE OF RESPIRATOR SOLVES THE PROBLEM OF PIPE EXTUBATION AND WRONG CONNECTION WHEN TESTING.
PARAMETER:
1. FLOWMETER RANGE: 0 ~ 100L/MIN, ACCURACY IS 3%
2. DIGITAL PRESSURE DIFFERENCE METER RANGE: 0 ~ 2000PA, ACCURACY: 1PA
3. PUMPING CAPACITY OF AIR PUMP: >100L/MIN
4. OVERALL SIZE: 460 X 1080 X 670mm
5. POWER SOURCE: AC220V 50HZ 650W
6. WEIGHT: 55KG
QUANTITY: 1
Learn More -
T-6552 MASK AIR TIGHTNESS TESTERREFERENCE NUMBER: T-6552
MASK AIR TIGHTNESS TESTER
MASK AIR TIGHTNESS TESTER
HOW TO CHOOSE A HIGH-QUALITY MASK NOT ONLY DEPENDS ON THE FILTERING EFFICIENCY OF THEMASK, BUT ALSO TO CONFIRM WHETHER THE MASK IS COMPLETELY IN CONTACT WITH THE FACE, OTHERWISE AEROSOL PARTICLES SUCH AS GERMS THAT HAVE NOT BEEN FILTERED BY THE MASK WILL BE INHALED FROM THE INADEQUATE ADHESION. THEREFORE, IT IS VERY IMPORTANT TO CHECK THE WEARING STATUS OF THE MASK. THE EUROPEAN AND AMERICAN COUNTRIES HAVE LISTED THE APPLICATION TEST OF THE MASK AS A STRONG INSPECTION ITEM.
FOR EXAMPLE, THE N95 MASK IS ONE OF 9 TYPES OF PARTICULATE PROTECTIVE MASKS CERTIFIED BY NIOSH (NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH). "N" INDICATES OIL RESISTANCE."95" INDICATES THAT THE PARTICLE CONCENTRATION IN THE MASK IS MORE THAN 95% LOWER THAN THAT OF THE PARTICLES OUTSIDE THE MASK WHEN EXPOSED TO THE SPECIFIED NUMBER OF SPECIAL TEST PARTICLES. N95 IS NOT A SPECIFIC PRODUCT NAME, AS LONG AS IT MEETS THE N95 STANDARD AND PASSES THE NIOSH REVIEW, IT CAN BE CALLED "N95 MASK".
N95 TYPE MASKS, IN ADDITION TO THE FILTERING EFFICIENCY OF THE MASKS, THE CLOSENESS OF THE MASKS TO THE FACE IS ONE OF THE IMPORTANT FACTORS THAT DETERMINE THE EFFECTIVENESS OF THE USE OF THE MASKS. THE SUITABILITY OF DIFFERENT TYPES OF MASKS FOR THE HUMAN FACE VARIES GREATLY.
THEREFORE, BEFORE USING A MASK, THE SUITABILITY OF THE MASK SHOULD BE CHECKED FIRST. DURING THETIGHTNESS TEST OF THE WEARER'S FACE, ENSURE THAT AIR CAN PASS IN AND OUT THROUGH THE MASK WHEN IT IS CLOSE TO THE EDGE OF THE FACE. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTION PERFORMANCE. IT CONFORMS TO THE CHINESE RESPIRATOR STANDARD GB2626-2019 STANDARD, OSHA / CSA STANDARD AND CHINA GENERAL ADMINISTRATION OF QUALITY SUPERVISION, INSPECTION AND QUARANTINE "GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS" JOINTLY ISSUED BY THE CHINA NATIONAL STANDARDIZATION ADMINISTRATION COMMITTEE.
ADHESION (SUITABILITY TEST): THE MASK DESIGN SHOULD PROVIDE GOOD ADHESION. THE OVERALL FIT FACTOR OF THE MASK SHOULD NOT BE LESS THAN 100. THIS TEST THE REQUIREMENTS WERE FORMALLY IMPLEMENTED ON AUGUST 1, 2011.
Learn MoreMASK TIGHTNESS TESTER USES CNC TECHNOLOGY, SUITABLE FOR 100 / 99 / P3 / HEPASERIES MASKS DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING DISPOSABLE DUST MASKS SUCH ASN95 / N90 / KN95), GAS MASKS / BREATHING MASKS, ADHESIVENESS TEST OF HALF-MASK AND FULL FACE MASK, INDEPENDENT OR COMPUTER CONTROL, FIVE LANGUAGES SWITCH DISPLAY, EQUIPPED WITH MULTIPLE COMMUNICATION INTERFACES (USB, ETHERNET), WIFI CAN ALSO BE ENABLED, ONE COMPUTERCAN CONTROL FOUR INSTRUMENTS AT THE SAME TIME.PARAMETER:CONCENTRATION RANGE: 0 ~ 100,000 / CM3GRAIN DIAMETER: 0.02 ~ 1.0^MFLOW: SAMPLING FLOW: 100CM3 / MINTOTAL FLOW: 700CM3 / MINCLOSENESS COEFFICIENT TEST: DIRECT TEST (COUT/ CIN)LIQUOR: 99.5% + ISOPROPANOL (ANALYTICAL GRADE)DISPLAY: 7INCH TRUE COLOR TOUCH SCREENCOMMUNICATION INTERFACE: USB X 3 (HOST X 2,DEVICE X 1) ETHERNET INTERFACE X1CONNECTION PORT: ENVIRONMENT PORT, SAMPLING PORTWIFI: EQUIPPEDLANGUAGES: ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESEFLOW CONTROL: SENSOR CONTROLPC CONTROLLABLE OPERATION: ONE COMPUTER CAN CONTROL 4 INSTRUMENTS AT THE SAME TIMEDATA OUTPUT FORMAT: MICROSOFT EXCELWORKING TEMPERATURE: 15 ~ 35 °CPOWER SOURCE: AC 110 —240V 50 / 60HZAPPEARANCE SIZE: 208 X 117 X 262MMWEIGHT: 2.1KGACCESSORIES: ALCOHOL REAGENT BOTTLE, PROTECTIVE CAP, REAGENT STICK, ZERO-COUNT FILTER, STRAINER, SAMPLING TUBE, INSTRUCTION MANUAL, AC ADAPTER, TOUCH SCREEN PEN, OPTIONAL COMPUTER.OPTIONAL: TEST KIT FOR TIGHTNESS COEFFICIENTIN ORDER TO PREVENT INFECTION AT THE MEDICAL SITE AND DURING LABOR WORK, WORKERS MUST BE PROTECTED FROM INHALABLE HAZARDOUS SUBSTANCES IN THE WORKPLACE, AND RESPIRATORS SUCH AS MASKS MUST BE WORN DURING WORK.SELECT A RESPIRATOR, SUCH AS A MASK, BASED ON YOUR FACIAL FEATURES, AND EVALUATE THE TIGHTNESS BETWEEN THE RESPIRATOR, SUCH AS A MASK AND THE FACE, TO CHECK WHETHER THERE ARE GAPS OR LEAKS THAT PUT WORKERS AT RISK. THE MASK TIGHTNESS TESTER CAN QUICKLY COMPLETE THE TIGHTNESS TEST OF RESPIRATORS SUCH AS MASKS TO ENSURE THAT IT PROVIDES GOOD PROTECTIVE PERFORMANCE. SECURITY EXPERTS WILL ALSO DEVELOP PROTECTION SCHEMES AND STANDARD REGULATIONS BASED ON THE RESULTS OF THE TIGHTNESS TEST. WIDELY USED IN HOSPITALS, MANUFACTURING PLANTS, PRODUCTION SITES, FIREFIGHTING WORKPLACES AND OTHER OFFICIAL TESTING AGENCIES.MASK TIGHTNESS TESTER FEATURES:• QUANTITATIVE TIGHTNESS TEST FOR RESPIRATORS SUCH AS MASKS (QNFT)• APPLICABLE TO 100/99 / P3 / HEPA SERIES MASK DISPOSABLE FILTER MASK TIGHTNESS TEST (INCLUDING N95 / N90 / KN95 AND OTHER DISPOSABLE DUST MASKS)• ADHESION TEST OF HALF MASK AND FULL FACE MASK• GAS MASK TIGHTNESS TEST• PAPR MASK TIGHTNESS TEST• SCBA RESPIRATOR MASK TIGHTNESS TEST• 7INCH TRUE COLOR TOUCH SCREEN• INDEPENDENT OR COMPUTER CONTROLLED• USING CNC TECHNOLOGY• ENGLISH, FRENCH, SPANISH, PORTUGUESE, CHINESE LANGUAGE SWITCHING DISPLAY• COMPLIES WITH US OSHA STANDARDS, CANADIAN STANDARDS ASSOCIATION (CSA) GUIDELINES, INCLUDING N95• EQUIPPED WITH A VARIETY OF COMMUNICATION INTERFACES (USB, ETHERNET), AND CAN ALSO ENABLE WIFI• ONE COMPUTER CAN CONTROL FOUR INSTRUMENTS AT THE SAME TIMEQUANTITY: 1