Search results for: 'can c'
-                  T-6546 PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKREFERENCE NUMBER: T-6546PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKINTRODUCTIONMEDICAL SURGICAL MASK PARTICLE FILTRATION EFFICIENCY PFE TESTER IS SUITABLE FOR MEDICAL INSTRUMENT INSPECTION CENTER, SAFETY PROTECTION INSPECTION CENTER, LABOR PROTECTION INSPECTION CENTER, DRUG INSPECTION CENTER, DISEASE PREVENTION AND CONTROL CENTER, TEXTILE INSPECTION CENTER, HOSPITAL, MASK AND RESPIRATOR MANUFACTURERS, ETC.FEATURESTHE PFE TESTER FOR PARTICLE FILTRATION EFFICIENCY OF SURGICAL MASKS IS EQUIPPED WITH A SPECIAL SALT AEROSOL GENERATOR, WHICH CAN PRODUCE AEROSOLS WITH SPECIFIC PARTICLE SIZE AND CONCENTRATION.EQUIPPED WITH A SERIES OF SPECIAL FIXTURE, SUITABLE FOR THE DETECTION OF ALL KINDS OF MASKS.BUILT-IN HIGH LIFE PHOTOMETER MODULE, SAMPLING TIME ACCUMULATION, PROMPT LIGHT CLEANING.AUTOMATIC CONTROL OF AEROSOL GENERATION, AUTOMATIC CALCULATION OF CAPTURE EFFICIENCY AND MASK AIRFLOW RESISTANCE, REDUCE HUMAN INTERVENTION.BUILT-IN HIGH PRECISION ELECTRONIC FLOWMETER AND HIGH PERFORMANCE SAMPLING PUMP TO ENSURE FLOW STABILITY.PARAMETERTEST FLOW: PARAMETER RANGE: (5 ~ 100) L/MIN; RESOLUTION: (5 ~ 100) L/MIN;MAXIMUM ALLOWABLE ERROR: ±1%PRESSURE DETECTION RANGE: PARAMETER RANGE: (0 ~ 2500) PA; RESOLUTION: 0.1PA; MAXIMUM ALLOWABLE ERROR: ±1%CONCENTRATION DETECTION RANGE: PARAMETER RANGE: (0.001 ~ 100) 0 G/L;DETECTION ACCURACY: 1% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100%DETECTION REPEATABILITY: 5% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100% MEDIAN DIAMETER OF SALT AEROSOL PARTICLES (CMD): (0.075±0.02)MMEDIAN AEROSOL PARTICLE NUMBER DIAMETER (CMD) (OPTIONAL): (0.185±0.02) MOPERATING TEMPERATURE: 20±5CLearn MoreINSTRUMENT NOISE: <60DB(A)POWER SUPPLY: AC220V±10%, 50HZMAIN MACHINE SIZE: (LENGTH 700 X WIDTH 720 X HEIGHT 1450) mmQUANTITY: 1 T-6546 PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKREFERENCE NUMBER: T-6546PFE TESTER FOR PELLET FILTRATION EFFICIENCY OF SURGICAL MASKINTRODUCTIONMEDICAL SURGICAL MASK PARTICLE FILTRATION EFFICIENCY PFE TESTER IS SUITABLE FOR MEDICAL INSTRUMENT INSPECTION CENTER, SAFETY PROTECTION INSPECTION CENTER, LABOR PROTECTION INSPECTION CENTER, DRUG INSPECTION CENTER, DISEASE PREVENTION AND CONTROL CENTER, TEXTILE INSPECTION CENTER, HOSPITAL, MASK AND RESPIRATOR MANUFACTURERS, ETC.FEATURESTHE PFE TESTER FOR PARTICLE FILTRATION EFFICIENCY OF SURGICAL MASKS IS EQUIPPED WITH A SPECIAL SALT AEROSOL GENERATOR, WHICH CAN PRODUCE AEROSOLS WITH SPECIFIC PARTICLE SIZE AND CONCENTRATION.EQUIPPED WITH A SERIES OF SPECIAL FIXTURE, SUITABLE FOR THE DETECTION OF ALL KINDS OF MASKS.BUILT-IN HIGH LIFE PHOTOMETER MODULE, SAMPLING TIME ACCUMULATION, PROMPT LIGHT CLEANING.AUTOMATIC CONTROL OF AEROSOL GENERATION, AUTOMATIC CALCULATION OF CAPTURE EFFICIENCY AND MASK AIRFLOW RESISTANCE, REDUCE HUMAN INTERVENTION.BUILT-IN HIGH PRECISION ELECTRONIC FLOWMETER AND HIGH PERFORMANCE SAMPLING PUMP TO ENSURE FLOW STABILITY.PARAMETERTEST FLOW: PARAMETER RANGE: (5 ~ 100) L/MIN; RESOLUTION: (5 ~ 100) L/MIN;MAXIMUM ALLOWABLE ERROR: ±1%PRESSURE DETECTION RANGE: PARAMETER RANGE: (0 ~ 2500) PA; RESOLUTION: 0.1PA; MAXIMUM ALLOWABLE ERROR: ±1%CONCENTRATION DETECTION RANGE: PARAMETER RANGE: (0.001 ~ 100) 0 G/L;DETECTION ACCURACY: 1% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100%DETECTION REPEATABILITY: 5% OF THE READ VALUE IN THE RANGE OF 0.01% TO 100% MEDIAN DIAMETER OF SALT AEROSOL PARTICLES (CMD): (0.075±0.02)MMEDIAN AEROSOL PARTICLE NUMBER DIAMETER (CMD) (OPTIONAL): (0.185±0.02) MOPERATING TEMPERATURE: 20±5CLearn MoreINSTRUMENT NOISE: <60DB(A)POWER SUPPLY: AC220V±10%, 50HZMAIN MACHINE SIZE: (LENGTH 700 X WIDTH 720 X HEIGHT 1450) mmQUANTITY: 1
-                  T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKS T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKSREFERENCE NUMBER: T-6547 RESPIRATOR RESISTANCE TESTER FOR FACE MASKS INTRODUCTION THE RESPIRATOR RESISTANCE TESTER IS USED TO MEASURE THE INSPIRATORY RESISTANCE AND EXPIRATORY RESISTANCE OF RESPIRATORS AND RESPIRATOR PROTECTORS UNDER SPECIFIED CONDITIONS. IT IS APPLICABLE TO THE NATIONAL LABOR PROTECTION EQUIPMENT INSPECTION INSTITUTIONS, MASK MANUFACTURERS FOR THE GENERAL MASKS, DUST MASKS, MEDICAL MASKS, ANTI-SMOG MASKS PRODUCTS OF THE RELEVANT TESTING AND INSPECTION. STANDARD GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS GB 2626-2006 RESPIRATOR SELF-SUCTION FILTER RESPIRATOR AGAINST PARTICULATE MATTER GB/T 32610-2016 TECHNICAL SPECIFICATIONS FOR DAILY PROTECTIVE MASKS FEATURES: 1. HIGH-DEFINITION LCD DISPLAY. 2. DIGITAL DIFFERENTIAL PRESSURE METER WITH HIGH PRECISION IMPORTED BRAND. 3. HIGH PRECISION IMPORTED BRAND OF DIGITAL FLOWMETER, WITH HIGH FLOW CONTROL ACCURACY FEATURES. 4. THE RESPIRATOR RESISTANCE TESTER CAN SET UP TWO MODES: EXHALATION DETECTION AND INHALATION DETECTION. 5. AUTOMATIC PIPELINE SWITCHING DEVICE OF RESPIRATOR SOLVES THE PROBLEM OF PIPE EXTUBATION AND WRONG CONNECTION WHEN TESTING. PARAMETER: 1. FLOWMETER RANGE: 0 ~ 100L/MIN, ACCURACY IS 3% 2. DIGITAL PRESSURE DIFFERENCE METER RANGE: 0 ~ 2000PA, ACCURACY: 1PA 3. PUMPING CAPACITY OF AIR PUMP: >100L/MIN 4. OVERALL SIZE: 460 X 1080 X 670mm 5. POWER SOURCE: AC220V 50HZ 650W 6. WEIGHT: 55KG QUANTITY: 1 Learn More
-                  T-6548 FABRIC SURFACE WETTING TESTER T-6548 FABRIC SURFACE WETTING TESTERREFERENCE NUMBER: T-6548 FABRIC SURFACE WETTING TESTER INSTRUMENT TECHNICAL DESCRIPTION: WATER TESTER IS TO INSTALL THE SAMPLE ON THE SAMPLE HOLDER AND MAKE AN ANGLE OF 45 ° WITH THE LEVEL. THE CENTER OF THE SAMPLE IS LOCATED AT A SPECIFIED DISTANCE BELOW THE NOZZLE. THE SAMPLE IS SPRAYED WITH A SPECIFIED VOLUME OF DISTILLED OR DEIONIZED WATER. BY COMPARING THE APPEARANCE OF THE SAMPLE WITH THE EVALUATION STANDARDS AND PICTURES TO DETERMINE ITS WATER-SOAKING GRADE, IT IS SUITABLE FOR MEASURING VARIOUS WATER-SOAKING TESTS ON THE SURFACE OF FABRICS WITH OR WITHOUT WATER RESISTANCE AND WATER REPELLENT FINISHING. THIS INSTRUMENT IS NOT SUITABLE FOR MEASURING THE WATER PERMEABILITY OF FABRICS, SO IT CANNOT BE USED TO PREDICT THE RAINPROOF PERMEABILITY OF FABRICS. STANDARD: GB19082-2009 TECHNICAL REQUIREMENTS FOR MEDICAL PRIMARY PROTECTIVE CLOTHINGGB / T4745 SURFACE MOISTURE RESISTANCE TEST THE MAIN TECHNICAL INDICATORS OF THE INSTRUMENT: GLASS FUNNEL: φ150mm MEASURING CUP: 500ML SAMPLE SUPPORT ANGLE: 45 ° INSTRUMENT CONFIGURATION: 1. ONE HOST 2. A GLASS FUNNEL 3. 500ML MEASURING CUP QUANTITY: 1 Learn More
-                  T-6551 MASK FLAME RETARDANT PERFORMANCE TESTER T-6551 MASK FLAME RETARDANT PERFORMANCE TESTERREFERENCE NUMBER: T-6551 MASK FLAME RETARDANT PERFORMANCE TESTER MASK FLAME RETARDANT PERFORMANCE TESTER TECHNICAL INDEX: 1.THE LINEAR VELOCITY OF THE NOSE TIP OF THE DIE IS (60 ± 5) MM / S 2.THE DIAMETER OF FLAME TEMPERATURE MEASURINGPROBE IS 1.5MM 3.THE FLAME TEMPERATURE IS (800 ± 50) °C 4.THE DISTANCE BETWEEN THE BURNER TOP AND THE MASK IS (20 ± 2) MM 5.METAL DIE APPLICABLE STANDARD: GB 19083-2010 TECHNICAL REQUIREMENTS FOR MEDICAL PROTECTIVE MASKS YY 0469-2011 MEDICAL SURGICAL MASK MEDICAL PROTECTIVE MASK REFERS TO A SELF-PRIMING FILTER TYPE DUST-PROOF MEDICAL PROTECTIVE MASK THAT CAN FILTER THE PARTICLES IN THE AIR AND BLOCK THE DROPLETS, BLOOD, BODY FLUIDS, SECRETIONS, ETC. QUANTITY: 1 Learn More
-                  T-6583 PROTECTIVE SUIT T-6583 PROTECTIVE SUITREFERENCE NUMBER: T-6583 PROTECTIVE SUIT TWO-PIECE HOODED DESIGN: WITH TWO-PIECE HOODED THREE-DIMENSIONAL CUT AND ELASTIC BAND AROUND THE FACE OPENING, THE HOOD CAN BETTER FIT THE SHAPE OF FACE AND ENHANCE THE PROTECTION EFFECT. SEAM SEALED TAPE WORKMANSHIP: EACH SEAM IS SEALED WITH TAPE, AND THE WAIST IS APPLIED WITH AN INTERNAL ELASTIC BAND, WHICH BETTER ENHANCE THE SEAM PROTECTION AND THE FITNESS OF THE SUIT. ELASTIC CUFF: THE CUFF USES AN INTERNAL ELASTIC BAND TO FURTHER ENHANCE TIGHTNESS AND PROTECTION. CLOSED PLACKET DESIGN: CENTER FRONT ZIPPER APPLICATION ALLOWS EASY PUT-ON AND TAKE-OFF, WHILE THE ZIPPER PLACKET DESIGN BRINGS BETTER PROTECTION TECHNOLOGICAL DETAILS: (1)NEEDLE STITCHING, BONDING, AND HEAT-SEALING PROCESSES ARE APPLIED TO THE CONNECTION PART OF THE PROTECTIVE SUIT. THE HOLES OF THE STITCHES ARE SEALED. THE STITCH PITCH SHOULD BE 8 TO 14 STITCHES PER 3CM. THE STITCHES ARE ALIGNED AND PROPERLY SPACED. THERE SHOULDN' T BE SKIPPED STITCH. BONDED OR HOT-SEALED PARTS SHALL BE FLAT AND SEALED WITHOUT AIR BUBBLES. (2)THE ZIPPER OF THE PROTECTIVE CLOTHING SHOULD NOT BE EXPOSED,AND THE ZIPPER PULLER SHOULD BE SELF-LOCKING. (3)THE STRUCTURE OF PROTECTIVE SUIT SHOULD BE IN CONFORMITY, EASY TO PUT ON AND TAKE OFF, AND THE JOINTS MUST BE TIGHT. (4)ELASTIC CUFFS AND ANKLES, AND ELASTIC HOOD AND WAIST OPENINGS. (5)THE PROTECTIVE SUIT IS IN OVERALL STRUCTURE,WHICH CONSISTS OF A HOODED TOP AND PANTS. Learn More
-                  T-6581 MEDICAL DISPOSABLE PROTECTIVE CLOTHING SUIT T-6581 MEDICAL DISPOSABLE PROTECTIVE CLOTHING SUITREFERENCE NUMBER: T-6581 MEDICAL DISPOSABLE PROTECTIVE CLOTHING SUIT MEDICAL DISPOSABLE PROTECTIVE CLOTHING SUIT MEETS GB19082-2009 EN14126 TESTING STANDARD CAPACITY 100,000 PIECES/DAY(CAPACITY CAN BE ENLARGEDACCORDING TO THE ORDER) PRODUCTION CAPACITY IS EXPANDING LARGE QUANTITY IS PREFERRED THE PAYMENT METHOD IS 100% IN ADVANCE NOTE: IN THE MASS PRODUCTION OF PROTECTIVE CLOTHING, THE GOVERNMENT, HOSPITALS, AND DISEASE CONTROL CENTERS HAVE PRIORITY IN PURCHASING MATERIAL: MADE OF 65GWHITE COMPOSITE FILM + 30G NONWOVEN FABRIC + 25G FILM + 3G GLUE + 2.0CM EVA 0.12MMSEALED LINE, TWO PARTS OF PROTECTIVE CLOTHING, HOODEDTOTAL WEIGHT OF CLOTHING IS ABOUT 330-350 G ONLY HOSPITAL ICU REQUIRED STERILE TYPE, ALL OTHER PLACESREQUIRED NON-STERILE TYPEPACKAGE: MEDICAL PROTECTIVE CLOTHING CARTON OUTER BOX SIZE: 560 X360 X400mm SINGLE BOX WEIGHT: 13.5 KG(VOLUME WEIGHT:16.5 KG)45 PIECES PER BOX MINIMUM ORDER QUANTITY: 10,000 PIECES Learn More
-                  T-6588 MEDICAL PROTECTIVE CLOTHING T-6588 MEDICAL PROTECTIVE CLOTHINGREFERENCE NUMBER: T-6588 MEDICAL PROTECTIVE CLOTHING ITEM NAME: MEDICAL PROTECTIVE SUITS MATERIAL; SMSNON WOVEN +MELTBLOWN NON-WOVEN FABRIC +THREE LAYER FIBER WEB PRODUCT QUALIFICATION:CE CERTIFICATION AND FDA PHARMACEUTICAL INDUSTRY LICENSE PRODUCT DESCRIPTION: RADIATION STERILIZED PROTECTIVE CLOTHING THAT CAN ENTER ICU PROTECTION FOR UP TO 24 HOURS PRODUCT PERFORMANCE: SOFT, LIGHT, GOOD AIR PERMEABILITY, WATERPROOF AIR PERMEABILITY 7770 / M2 / DAY THE SURFACE MOISTURE RESISTANCE REACHES LEVEL 4 (GB / 74745 /1997) THE ANTI SYNTHETIC BLOOD PENETRATION REACHED GRADE 4 SIZE: S,M,L, XL, 2XL PACKAGE SIZE: APPROX: 650 X 340 X 285mm PACKAGE WEIGHT: APPROX. 260G / 9.2OZ LEAD TIME STOCK: 3-4 DAYS BY FEDEX; MASS GOODS: 3-7 DAYS ITEM 001 QUANTITY: 1,000 ITEM 002 QUANTITY: 5,000 ITEM 003 QUANTITY: 15,000 LEAD TIME STOCK: 3-4DAYS BY FEDEX; MASS GOODS: 8-15 DAYS ITEM 004 QUANTITY: 50,000 ITEM 005 QUANTITY: 100,000 Learn More
-                  V-1808 TEMPERATURE MEASUREMENT AND FACE RECOGNITION DEVICE V-1808 TEMPERATURE MEASUREMENT AND FACE RECOGNITION DEVICECAN CHECK HUMAN TEMPERATURE 
 HAS FACE RECOGNITION
 USES: AS AN ENTRANCE GUARD, TO CHECK ATTENDANCE, ETC.QUANTITY: 1 Learn More
-                  V-1820 MASK AND RESPIRATOR FIELD TESTER V-1820 MASK AND RESPIRATOR FIELD TESTERMAINLY USED FOR VISUAL FIELD TESTING OF MASKS AND RESPIRATORS, WHICH IS USEFUL FOR MASK AND RESPIRATOR MANUFACTURERS, QUALITY SUPERVISORS, SCIENTIFIC RESEARCH, AND FOR TESTING PRIOR TO SELLING MASKS. FEATURES: 
 1. THE EQUIPMENT IS COMPOSED OF A SEMI-ARC BOW, RECORDING DEVICE, SEAT FRAME AND TEST HEAD DIE.
 2. SEMI-ARC BOW: THE RADIUS IS 300 TO 340 mm
 CAN BE ROTATED AROUND THE HORIZONTAL RADIUS PLANE PASSING THROUGH THE POINT 0°, AND A SCALE EXTENDING TO THE 90° ARC BOW EVERY 5° FROM 0° ON BOTH SIDES, EQUIPPED WITH SLIDING WHITE VISUAL STANDARD.
 3. RECORDING DEVICE: THE RECORDING NEEDLE IS CONNECTED WITH THE VISUAL STANDARD THROUGH COMPONENTS SUCH AS AXLE WHEEL, AND THE DIRECTION AND ANGLE OF THE VISUAL STANDARD ARE RECORDED ON THE VISUAL FIELD DRAWING CORRESPONDINGLY.
 4. SEAT FRAME: USED TO SUPPORT SEMI-CIRCULAR ARC BOW AND FIXED RECORDING DEVICE.
 5. TEST THE HEAD MOLD: A STANDARD HEAD MOLD, THE TWO EYE HOLES OF THE HEAD MOLD ARE EQUIPPED WITH SMALL LIGHT BULBS, THE POSITION OF THE BULB AND THE POSITION OF THE HEAD MOLD ARE ACCORDING TO THE REQUIREMENTS OF GB 2890. THE TEST HEAD DIE MUST BE INSTALLED ON THE WORKBENCH IN SUCH A WAY THAT THE LEFT AND RIGHT EYES ARE PLACED AT THE CENTER OF THE SEMICIRCULAR ARCH AND THE "0" POINT IS DIRECTLY SEEN.MAIN INDICATORS Learn More
 1. SEMI-CIRCULAR ARC RADIUS: 335mm.
 2. LEFT AND RIGHT FIELD OF VIEW: ≤120°.
 3. BULB DISTANCE: THE VERTEX OF THE BULB IS CONNECTED AFTER THE TWO EYE POINTS (7±0.5).
 APPLICABLE STANDARDS: GB/T 32610-2016, GB 2626-2019, GB2890-2009
-                  H-2414 8” FACIAL RECOGNITION WITH TEMPERATURE DETECTION PANEL PC H-2414 8” FACIAL RECOGNITION WITH TEMPERATURE DETECTION PANEL PCPC MAIN SPECS: 
 CPU: HISILICON HI3516D V300 DUAL CORE, CORTEX-A7, 1.0 TOPS
 RAM: 4GB
 STORAGE: 16GB (CAN SAVE 50,000 FACE DATABASE)
 LINUX OS
 WORKING TEMPERATURE: -20°C TO 60°C
 SUPPORT LIVE DETECTION
 SUPPORT FACE RECOGNITION, RECOGNITION DISTANCE: ≤500mm, TIME: ≤ 0.2S
 SUPPORT AUTOMATIC TEMPERATURE DETECTION, RECOGNITION DISTANCE: ≤ 500mm, TIME: ≤0.3S
 SUPPORT THE SECONDARY DEVELOPMENT OF DEVICE-SIDE APPLICATION
 SOFTWARELCD PANEL MAIN SPECS: Learn More
 RESOLUTION: 800 X 1280 (10:16)
 BRIGHTNESS: 500CD/M2 (TYP)
 CONTRAST: 800:1
 INTERFACES: 1 X LAN/ 1 X WIGEN OUTPUT/1 X RELAY OUTPUT/ 1 X DC INPUT
 SUPPORT DISPLAY OUTPUT TO LAPTOP PC OR DESKTOP PC VIA LAN PORT
 SENSOR:
 1 X FAR INFRARED TEMPERATURE SENSOR
 1 X 2MP FRONT CAMERA
