Search results for: 'electric'''
- YY-1136 ULTRAVIOLET STERILIZERYY-1136 ULTRAVIOLET STERILIZER MAINTENANCE OF UV STERILIZER: 1 CHECK REGULARLY TO ENSURE THE NORMAL OPERATION OF THE UV LAMP. 2. AFTER 9000 HOURS OR ONE YEAR OF CONTINUOUS USE, THE ULTRAVIOLET LAMP SHOULD BE REPLACED. WHEN REPLACING A NEW LAMP, FIRST UNPLUG THE POWER SOCKET OF THE LAMP AND TAKE OUT THE ULTRAVIOLET LAMP. PAY ATTENTION NOT TO TOUCH THE QUARTZ GLASS OF THE NEW LAMP WITH YOUR FINGERS, BECAUSE THE STAIN WILL AFFECT THE INTENSITY OF THE LIGHT, AND CAREFULLY PUT THE LAMP INTO THE CHAMBER OF THE STERILIZER. Learn More
- T-7934 MEDICAL SURGICAL LATEX GLOVES INNER PACKING MACHINET-7934 MEDICAL SURGICAL LATEX GLOVES INNER PACKING MACHINE A. IT IS MAINLY USED FOR LATEX GLOVE INSIDE PACKING, GLOVE LENGTH FROM 175 TO 190mm CAN BE ADJUSTED, WIDTH FROM 90 TO 110MM CAN BE ADJUSTED, B. SPEED: 20 TO 28 PCS/MIN C. VOLTAGE: 380V, WORKING AIR PRESSURE: 0.6 TO 1.0MP D. TOTAL POWER: 4KW Learn More
- AA-1203 ACCESS CONTROL AND TIME ATTENDANCE DEVICE WITH TEMPERATURE MEASUREMENT FUNCTIONAA-1203 ACCESS CONTROL AND TIME ATTENDANCE DEVICE WITH TEMPERATURE MEASUREMENT FUNCTION FACE RECOGNITION SPEED: ≤1S POWER SUPPLY: 12V/3A OPERATING HUMIDITY: 10% TO 90% OPERATING TEMPERATURE: -10℃ TO 45℃ DIMENSIONS: 91,93 x 220 x 22,5mm Learn More
- T-6545 MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTER
REFERENCE NUMBER: T-6545
MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTER
PRODUCT INTRODUCTION:
MASK BACTERIA FILTRATION EFFICIENCY KEY PERFORMANCE INDICATORS (BFE) DETECTOR TESTER NOT ONLY CONFORMS TO THE REQUIREMENTS OF MEDICAL SURGICAL MASKS TECHNOLOGY YY0469-2011 APPENDIX B IN THE TEST METHOD FOR FILTER EFFICIENCY (BFE) BACTERIA FIRST B. 1.1.1 TEST INSTRUMENT, BUT ALSO CONFORMS TO THE AMERICAN SOCIETY FOR TESTING MATERIAL ASTMF2100, ASTMF2101, THE REQUIREMENTS OF THE EUROPEAN EN14683 STANDARDS, INNOVATIVE IMPROVEMENTS WERE MADE ON THE BASIS OF THIS, WITH DOUBLE PNEUMATIC CONTRAST SAMPLING METHOD AT THE SAME TIME, IMPROVE THE PRECISION OF SAMPLING,IT IS SUITABLE FOR MEASURING AND TESTING DEPARTMENTS, SCIENTIFIC RESEARCH INSTITUTES, MASK MANUFACTURERS AND OTHER RELEVANT DEPARTMENTS TO TEST THE PERFORMANCE OF MASK BACTERIAL FILTRATION EFFICIENCY.
EXECUTION STANDARD:
Q/0212 ZRB003-2015 MEDICAL SURGICAL MASK
BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR RELATED INTELLECTUAL PROPERTY:
NO.: ZL200820224142.6 ELECTRIC FLOW CONTROL VALVE
NO.: ZL200820224143.0 GAS CAPACITY
NO.: ZL200920308391.8 AIR FILTRATIONMATERIAL FILTRATION EFFICIENCY DETECTOR
PRODUCT FEATURES:
NEGATIVE PRESSURE TEST SYSTEM TO ENSURE THE SAFETY OF OPERATORS;
BUILT -IN PERISTALTIC PUMP IN NEGATIVE PRESSURE CABINET, A, B TWO -WAY, SIX ANDERSEN; THE PERISTALTIC PUMP FLOW CAN BE SET;
THE FLOW RATE OF NIGHT SPRAY CAN BE SET AND THE ATOMIZATION EFFECT IS GOOD.
EMBEDDED HIGH SPEED INDUSTRIAL MICROCOMPUTER CONTROL; 10.4 INCHES INDUSTRIAL HIGH BRIGHTNESS COLOR TOUCH SCREEN;
USB INTERFACE, SUPPORT U DISK DATA STORAGE;
CABINET BUILT-IN HIGH BRIGHTNESS LIGHTS; BUILT-IN LEAKAGE PROTECTION SWITCH TO PROTECT THE SAFETY OF OPERATORS;
THE INNER LAYER OF THE CABINET IS MADE OF STAINLESS STEEL, THE OUTER LAYER IS SPRAYED WITH PLASTIC AND COLD-ROLLED, AND THE INNER AND OUTER LAYERS ARE INSULATED AND FLAME RETARDANT.
THE FRONT SWITCH TYPE GLASS DOOR IS CONVENIENT FOR THE EXPERIMENTER TO OBSERVE AND OPERATE.
DETACHABLE BRACKET, ADJUSTABLE BRACKET HEIGHT; SUPPORTING AND MOVING DUAL PURPOSE CASTERS.
QUANTITY: 1
Learn More - T-6575 NON-INVASIVE VENTILATOR
NON-INVASIVE VENTILATOR
Learn More
CERTIFICATE: CE
MEDICAL VENTILATOR
TECHNICAL PARAMETERS OF DOUBLE LEVEL VENTILATOR
VENTILATOR TYPE: ELECTRIC CONTROL
SCOPE OF APPLICATION: TREATMENT AND TITRATION OF SLEEP APNEA HYPOPNEA SYNDROME, SEVERE SNORING, AND RESPIRATORY INSUFFICIENCY.
DISPLAY INTERFACE: 3.5-INCH LED SCREEN, CHINESE OPERATING SYSTEM
*VENTILATION MODE: CPAP, S, S/T, T
PRESSURE RANGE:
PRESSURE RANGE: 4-30CMH2O (±0.5CMH2O)
PRESSURE ACCURACY: + 0.5CMH2O
PARAMETER SETTING:
DELAYED BOOST: 0-60MIN, SET THE DIVISION INTERVAL 5MIN
INITIAL PRESSURE: 4CMH2O TREATMENT PRESSURE / RESPIRATORY PRESSURE SETTING
THERAPEUTIC PRESSURE: 4-20CMH2O (IN CPAP MODE)
TARGET TIDAL VOLUME: 150ML - 1500ML, ON/ OFF
MAXIMUM SUCTION PRESSURE: 4-30CMH2O, (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
MINIMUM SUCTION PRESSURE: 4-30CMH2O (NOT HIGHER THAN THE SUCTION PRESSURE), (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
INSPIRATORY PHASE PRESSURE: 4-30CMH2O
EXPIRATORY PRESSURE: 4-30CMH2O
EXPIRATORY DECOMPRESSION: PATIENT, OFF, 1-3, THREE ADJUSTABLE
MANUAL VOLTAGE REGULATION: 0-2 GEAR, 0-2CMH2O (ONLY AVAILABLE IN CPAP MODE)
INSPIRATORY SENSITIVITY: 1-8 STALLS
EXPIRATORY SENSITIVITY: 1-8 STALLS
RESPIRATORY FREQUENCY: 3-40 TIMES / MIN
INSPIRATORY TIME: 0.3-3.0S
BACKUP RATE: ON / OFF, DEFAULT 10
PRESSURE RISE TIME: 1-4 STALLS
HUMIDIFIER: 1-5 ADJUSTABLE IN 5 GEARS
*TITRATION FUNCTION: SUPPORT MANUAL AND AUTOMATIC PRESSURE TITRATION, BUILT-IN REMOTE WIRELESS COMMUNICATION MODULE, COMPLETE THE RANDOM SWITCHING OF SINGLE AND DOUBLE LEVEL MODES IN THE TITRATION PROCESS, AND CONTROL MORE THAN 11 VENTILATOR PARAMETERS AT THE SAME TIME.
AUXILIARY FUNCTION: AUTOMATIC AIR LEAKAGE COMPENSATION, AUTOMATIC STARTUP, AUTOMATIC SHUTDOWN, DELAYED SHUTDOWN, SCREEN BACKLIGHT ADJUSTMENT
MONITORING PARAMETERS: PRESSURE, TIDAL VOLUME, RESPIRATORY RATE, MINUTE VENTILATION VOLUME, AIR LEAKAGE VOLUME, INSPIRATORY TIME, BLOOD OXYGEN SATURATION
WAVY CURVE: PRESSURE TIME WAVEFORM, FLOW RATE TIME WAVEFORM
ALARM PROMPT: PIPELINE AND MASK FALLING OFF, AIR LEAKAGE PROMPT, POWER INTERRUPTION, TREATMENT MACHINE FAILURE, HUMIDIFIER FAILURE, LOW VOLTAGE, HIGH RESPIRATORY RATE, LOW RESPIRATORY RATE, LOW MINUTE VENTILATION VOLUME, LOW BLOOD OXYGEN, REPLACEMENT OF FILTER COTTON, FULL SD CARD, RE INSERTION OF SD CARD
*DATA MANAGEMENT:
NETWORK DATA: BMC + RESPIRATORY HEALTH MANAGEMENT CLOUD PLATFORM
SD CARD DATA: RESART NPAP DATA ANALYSIS SOFTWARE
PARTS:
SD CARD: STANDARD
SD CARD SLOT: STANDARD
PIPING: 9 22MM, 1.8M LONG
FACE SHIELD: F2 NOSE MASK AS STANDARD
NOISE: LESS THAN 30DB
ENVIRONMENT CONDITION:
TEMPERATURE:
(WHEN USED) 5 -35 C
(DURING TRANSPORTATION AND STORAGE) -20 C -55 C
ATMOSPHERIC PRESSURE:
(WHEN USED) 760-1060HPA
(DURING TRANSPORTATION AND STORAGE) 760-1060HPA
WORKING HOURS: MORE THAN 8 HOURS
POWER SUPPLY REQUIREMENTS:
AC VOLTAGE: 100-240V
FREQUENCY: 50HZ/60HZ
INPUT POWER: LESS THAN 2A
WATERPROOF LEVEL: IP22 - DRIP PROOF EQUIPMENT
INSTRUMENT SIZE: 290mm X 180mm X 134mm
WEIGHT: 1.5KG (EXCLUDING HUMIDIFIER) 2.5KG (INCLUDING HUMIDIFIER)
ITEM 001
QUANTITY: 10 SETS-999 SETS
ITEM 002
QUANTITY: 1,000 SETS-9,999SETS
ITEM 003
QUANTITY: ≥10,000 SETS - L-7129 NONWOVEN SMS PRODUCTION LINE, 1600mm, SPUNBONDED, MELT BLOWN
PP CHIPS FOR MELTBLOWN: 1200 TO 2000
FABRIC WIDTH: 1600mm
2 SPINNING BEAMS FOR SPUNBOND & 1 FOR MELTBLOWN
BASIC WEIGHT: SMS 9 TO 80 GRAMS PER SQUARE METER
SS: 15 TO 100 GRAMS PER SQUARE METERPRODUCT:
SMS LAMINATED NONWOVEN FABRIC
SS SPUNBOND NONWOVEN FABRIC SS
M MELTBLOWN NONWOVEN FABRIC MTO MAKE HYGENIC FABRICS SUCH AS BABY DIAPERS, SANITARY NAPKINS, ADULT DIAPERS, MEDICAL OPERATION SUITS, OPERATION CAPS, OPERATIONS SHOES, MASKS, ETC.
CONSISTING OF:
3 X FEEDING SYSTEMS
AUTOMATIC VACUUM SUCTION FOR BOTH MAIN MATERIAL AND ADDITIVES
CAPACITY (SB + MB) 2 X 520 KGS/H, (SB) 2 X 200 KGS/HR
WITH THREE HOPPERS, THREE SUPPLIYING DEVICESSPUNBOND SYSTEM
2 X EXTRUDERS
DIAMETER: 150mm
CAPACITY: 450 KGS/HR
L/D 30:1
DRIVE POWER: 110 KW
HEATING POWER: 90 KW2 X RECYCLING SYSTEMS
DIAMETER: 105mm
CAPACITY: 100 KGS PER HOUR
L/D: 15:12 X MELT FILTERS
WORKING TEMPERATURE: UP TO 280 CELSIUS
FILTRATION CAPACITY: 520 KGS PER HOUR2 X METERING PUMPS
TYPE: GEAR PUMP
FLOW VOLUME: 250 ML/R
DESIGNING TEMPERATURE: 280 CELSIUS2 X MELT PIPELINES
WITH STATIC MIXER2 X MONOMER EXHAUSTER
INCLUDING BLOWER, CHILLER, PIPELINE, VALVE, INSULATION, ETC2 X SPINNING BEAMS
SINGLE COAT-HANGER MELT DISTRIBUTION
DESIGNING PRESSURE: 9MPA
WORKING TEMPERATURE: MAX 280 CELSIUS4 X SPINNERETS
HOLE DIAMETER: 0.45mm
L/D: 5:1
15,500 HOLESMELTBLOWN SYSTEM
1 X EXTRUDER
DIAMETER 120mm
CAPACITY: 280 KGS/HR
L/D: 30:1
DRIVE POWER: 75 KW
HEATING POWER: 80 KW1 X MELT FILTER
FILTRATION PRECISION: 20 TO 60 MICROMETERS
FILTRATION: 280 KGS PER HOUR1 X METERING PUMP
GEAR PUMP
MAX. FLOW VOLUME: 100ML/R
DESIGNED TEMPERATURE: 300 CELSIUS1 X MELT PIPELINE
WITH STATIC MIXER1 X SPINNING BEAM
INCLUDING STRETCHING CHANNEL, NOZZLE, ETC. WITH INSULATION MATERIAL
DESIGNED PRESSURE: 6 MPA2 X SPINNING DIE PACKS
COMPACT DIE PACKS
HOLE DIAMETER: 0.35mm
L/D: 12:1
# OF HOLES: 42HPI1 X SCREW BLOWER
INCLUDING MUFFLE, PRESSURE REDUCER VALVE, PIPELINE, ETC.
POWER: 200 KW1 X HOT AIR SYSTEM
FLOW VOLUME: 6000 CUBIC METERS PER HOUR
WORKING TEMP: MAX 350 CELSIUS
INCLUDING HEATER, STAINLESS STEEL PIPELINE, ETC.
POWER: 290 KW1 X OFF-LINE CONVEYOR
RANGE OF SPEED: 5 TO 100 METERS PER MINUTE1 X CONVEYOR
MECHANICAL SPEED: MAX 400 METERS PER MINUTE
BELT WIDTH AND PENETRATION
3800±10mm, 10000 CUBIC METERS PER H.M21 X CALENDAR
DOUBLE ROLLS HEATED BY OIL
PROCESS SPEED: 350 METERS PER MINUTE
EMBOSSING WIDTH: UP TO 2000mm
MAX LINEAR PRESSURE: 110 DAN/C
MAX. TEMP OF EMBOSSING ROLLER, 180 CELSIUS1 X WINDER
ONLINE CHANGING ROLL, ONLINE EDGE CUTTING, TENSION CONTROL
MAX. LINEAR SPEED: 350 METERS PER MINUTE
WIDTH: 1600mm
WIND DIAMETER: MAX 1500mm1 X SLITTER
MAX. LINE SPEED: 600 METERS PER MINUTE
MAX. WIND DIAMETER: 1200mm
MIN. SLITTING WIDE: 120mm
22 CIRCULAR BLADES1 X STEEL PLATFORM
1 X ELECTRICAL CONTROL SYSTEM
2 X OIL OVEN
1 X AIR CONDITIONING SYSTEM
1 X WATER COOLING SYSTEM
1 X CLEANING EQUIPMENTS FOR DIE PACK
1 X AUXILIARY PLATFORM
1 X AUXILIARY EQUIPMENTS
1 X LABORATORY TESTING DEVICE
Learn More - V-1817 SEMI-AUTOMATIC NOSE CLIP WELDING MACHINE
SEMI-AUTOMATIC NOSE CLIP WELDING MACHINE FOR NOSE CLIP WELDING FOR DUST MASK RESPIRATORS, IT’S EASY TO OPERATE, FIRM WELDING EFFECT. THIS MACHINE INCORPORATES CONSTANT TEMPERATURE WELDING, WHICH IS NOT HARMFUL TO THE FABRIC, IT’S THE IDEAL MACHINE FOR DUST MASK RESPIRATOR MANUFACTURING.
FEATURES:
1. THIS MACHINE IS EASY TO OPERATE; THE GLUED ALUMINUM NOSE CLIP IS MOVED BY PNEUMATIC THEN WELDED ONTO THE MASK.
2. IT’S HIGH PRECISION AND THE NOSE CLIP WELD IS FIRM.
3. WELDING WITH CONSTANT TEMPERATURE WHICH IS NOT HARMFUL TO THE FABRIC.
ITEM NAME
TECHNICAL PARAMTER
QTY
REMARK
SPECIFICATION
1200mm X 650mm X 1000mm
1
HONGDA
WEIGHT
50KG
EFFICIENCY
8 TO 15PCS/MIN
VOLTAGE
220V/380V
AIR PRESSURE
5KG/CM²
FREQUENCY
20KHZ
POWER
600W
MOLD SERVO MOTOR
SGM7G-09AFC61 4.4KW
1
YASKAWA
ULTRASONIC POWER SERVO MOTOR
SGM7G-13AFC61 1.3KW
2
YASKAWA
MATERIAL PULLING SERVO MOTOR
SGM7G-09AFC61 0.85KW
2
YASKAWA
MATERIAL FEEDING/CORRECTING/INDENTATION MOTOR
130BYG-350A
4
SONGYANG
POUCHING MOTOR
110BYG-350B
4
SONGYANG
110 STEPPER MOTOR
110BYG-350A
10
SONGYANG
UP AND LOWER MOTOR
90BYG-350A
2
SONGYANG
STEPPER MOTOR 56
SY57STH56-2004A
8
SONGYANG
DIRECT CURRENT MOTOR
0.4KW
2
DIRECT CURRENT MOTOR
0.6KW
1
ASYNCHRONOUS THREE-PHASE MOTOR
90S-6
1
0.75KW
FREQUENCY CONVERTER
AVF200-0152
1
1.5KW
MAIN PNEUMATIC COMPONENTS: AIRTAC(TAIWAN); MAIN ELECTRICAL COMPONENTS: PANASONIC(JAPAN), SICK(GERMANY), DONLIM(CHINA&JAPAN), ETC.
EMAIL US FOR PRICE & PICTURES
INCLUDE OUR REFERENCE NUMBER
- V-1816 AUTOMATIC RESPIRATOR REPLACEMENT FILTER MAKING MACHINE
AUTOMATIC RESPIRATOR REPLACEMENT FILTER MAKING MACHINE IS ALSO CALLED A PARTICULATE RESPIRATOR FILTER MAKING MACHINE OR HALF FACE RESPIRATOR FILTER MAKING MACHINE, IT’S MADE UNDER MATURE TECHNOLOGY THAT SUPPORTS AUTOMATICALLY MATERIAL FEEDING, WELDING, PUNCHING AND CUTTING, REPLACEMENT FILTER FORMING, THIS MACHINE IS EASY TO OPERATE, BY CHANGING THE ROLLER, IT CAN PRODUCE DIFFERENT SHAPES OF FILTER. THIS MACHINE INCORPORATES ADVANCED ULTRASONIC WELDING AND EQUIPPED WITH CONSTANT TEMPERATURE CONTROLLER WHICH ENSURES THE FILTER FIRMLY AND CLEARLY WELDED.
FEATURES:
1. ADVANCED ULTRASONIC TECHNOLOGY WITH FIRM WELDING EFFECT, IT’S EQUIPPED WITH PULL AND PUSH TYPE MATERIAL FEEDING WHICH MAKES IT EASIER OPERATING.
2. THE MOLD (PATTERN ROLLER) CAN BE CUSTOMIZED TO PRODUCE DIFFERENT FILTERS.
3. THE WELDING LINE IS CLEAR AND FIRM.
ITEM NAME
TECHNICAL PARAMETERS
QTY
REMARK
SPECIFICATION
1800mm X 1200mm X 1800mm
1
HONGDA
WEIGHT
500KG
EFFICIENCY
20 TO 30PCS/MIN
VOLTAGE
220V/380V
AIR PRESSURE
3-6KG/CM²
FREQUENCY
15/20KHZ
POWER
4200W
MOLD SERVO MOTOR
SGM7G-09AFC61 4.4KW
1
YASKAWA
ULTRASONIC POWER SERVO MOTOR
SGM7G-13AFC61 1.3KW
2
YASKAWA
MATERIAL PULLING SERVO MOTOR
SGM7G-09AFC61 0.85KW
2
YASKAWA
MATERIAL FEEDING/CORRECTING/INDENTATION MOTOR
130BYG-350A
4
SONGYANG
POUCHING MOTOR
110BYG-350B
4
SONGYANG
110 STEPPER MOTOR
110BYG-350A
10
SONGYANG
UP AND LOWER MOTOR
90BYG-350A
2
SONGYANG
STEPPER MOTOR 56
SY57STH56-2004A
8
SONGYANG
DIRECT CURRENT MOTOR
0.4KW
2
DIRECT CURRENT MOTOR
0.6KW
1
ASYNCHRONOUS THREE-PHASE MOTOR
90S-6
1
0.75KW
FREQUENCY CONVERTER
AVF200-0152
1
1.5KW
MAIN PNEUMATIC COMPONENTS: AIRTAC (TAIWAN); MAIN ELECTRICAL COMPONENTS: PANASONIC (JAPAN), SICK (GERMANY), DONLIM (CHINA&JAPAN), ETC.
EMAIL US FOR PRICE & PICTURES
INCLUDE OUR REFERENCE NUMBER
Learn More - M-6092 ETHYLENE OXIDE STERILIZER
REFERENCE NUMBER: M-6092
ETHYLENE OXIDE STERILIZERSTERILIZING TEMPERATURE: 0~100°C, PID ADJUSTABLE
Learn More
STERILIZING PRESSURE: -95~+80KPA
STERILIZING HUMIDITY: 20~100% RH, ADJUSTABLE
EO CONCENTRATION: 300~1,000 MG/L
STERILIZING TIME: 3~12 HRS - M-6096 AUTOMATIC GAUZE BANDAGE ROLLING EQUIPMENT
REFERENCE NUMBER: M-6096
AUTOMATIC GAUZE BANDAGE ROLLING EQUIPMENTRATED POWER: 3KW. H. COMPRESSED AIR PRESSURE REQUIRED30.5 MPA
Learn More
LABOR: 1 PERSON
EQUIPMENT SIZE: 2200mm (L) x 1200mm (W) x 1800mm (H)
NET WEIGHT: 700KG