M-6092 ETHYLENE OXIDE STERILIZER

REFERENCE NUMBER: M-6092
ETHYLENE OXIDE STERILIZER

STERILIZING TEMPERATURE: 0~100°C, PID ADJUSTABLE
STERILIZING PRESSURE: -95~+80KPA
STERILIZING HUMIDITY: 20~100% RH, ADJUSTABLE
EO CONCENTRATION: 300~1,000 MG/L
STERILIZING TIME: 3~12 HRS

In stock
SKU
M-6092
Call Image
Call: +1 (864) 574-0404

We will send this product in 2 days. Read more...

Call us now for more info about our products.

Return purchased items and get all your money back.

Buy this product and earn 10 special loyalty points!


REFERENCE NUMBER: M-6092
ETHYLENE OXIDE STERILIZER

IN CONFORMITY WITH EUROPE STANDARD EN 1422
SIZE: INNER CONTAINER: W135’H170’L900
(CM)//135x170x450//135x170x280//100x165x185
OUTSIDE: W190’H240’L945 (CM)//190x240x495//190x240x325//155x235x230
MATERIAL OF CASE BODY: STAINLESS STEEL, INNER CONTAINER 8mm, OUTSIDE SHELL 1.2mm
STERILIZING TEMPERATURE: 0~100°C, PID ADJUSTABLE
STERILIZING PRESSURE: -95~+80KPA
STERILIZING HUMIDITY: 20~100% RH, ADJUSTABLE
EO CONCENTRATION: 300~1,000 MG/L
STERILIZING TIME: 3~12 HRS
PRE-VACUUM: -90 KPA
TIMES OF AIR CHANGE: ARBITRARILY
VENTILATION TIME: ARBITRARILY
MAXIMUM ELECTRICAL HEATING POWER: 55KW//41KW//20KW//15KW
MAXIMUM STEAM HEATING POWER: 10KW
POWER SOURCE: 3-PHASE, 4-WIRE, 380 V, 50 HZ OR 220 V, 60 HZ
WHOLE PROCESS AUTOMATIC CONTROL BY COMPUTER
TWO LEVEL CONTROL: SIEMENS INDUSTRIAL CONTROL COMPUTER + SIEMENS PLC
1. AUTOMATIC DOOR OPENING AND CLOSING (SHIFTING TYPE), AUTOMATIC AIR INFLATION SEALING
2. AUTOMATIC CONTROL OF WHOLE STERILIZING PROCESS
3. AUTOMATIC ALARMING AND SAFE PROTECTION
MAIN ATTACHMENTS:
1. VACUUM SYSTEM (STERILIZING PRE-VACUUM, WASHING AFTER STERILIZATION, RELIEF OF DOOR SEALING)
2. HEATING AND HOT WATER CIRCULATION SYSTEM (HEATING OF STERILIZING CASE BODY, PRECONDITIONING OF GOODS TO BE STERILIZED, TEMPERATURE HOLDING)
3. EO GASIFYING AND AUTOMATIC DOSING (GAS MIXING) SYSTEM (EO MEDICINE, N2 AND CO2 MIXING THROUGH HEAT INTERCHANGE AND GASIFICATION)
4. AUTOMATIC HUMIDIFYING (STEAM GENERATOR) SYSTEM (HUMIDITY PRECONDITIONING OF GOODS TO BE STERILIZED)
5. PNEUMATIC SYSTEM AND AUTOMATIC DOOR-OPENING AND CLOSING DEVICES (CONTROL OF AUTOMATIC OPEN AND CLOSE OF VALVES AND DOORS, SELF-LOCK AND INTERLOCK OF DOORS, AND AUTOMATIC SEALING OF DOORS)
6. RESIDUAL GAS TREATMENT SYSTEM (NEUTRALIZATION TREATMENT OF RESIDUAL GAS)
7. AUTOMATIC ALARMING AND SAFETY TEST PROTECTION SYSTEM
8. DISPLAY, CONTROL, RECORD, PRINTING, SAVE, AND INQUIRY OF THE STERILIZING PARAMETERS AND TENDENCY CHART

Write Your Own Review