Search results for: 'horizontal'
- Related search terms
- horizontal foam
- horizontal foam cutting machin
- HORIZONTAL SLITTER
- horizontal splitting
- horizontal saw machi
- T-6544 SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
REFERENCE NUMBER: T-6544
SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
TECHNICAL INDICATORS:
1. THE PROTRUDING SAMPLE FIXING DEVICE CAN SIMULATE THE ACTUAL USE STATE OF THE MASK, SET ASIDE THE TEST TARGET AREA WITHOUT DESTROYING THE SAMPLE, AND DISTRIBUTE THE SYNTHETIC BLOOD IN THE TARGET AREA OF THE SAMPLE.
2. THE SPECIAL FIXED-PRESSURE INJECTION DEVICE CAN EJECT A CERTAIN VOLUME OF SYNTHETIC BLOOD IN A CONTROLLED TIME.
3. IT CAN FULLY SIMULATE THE INJECTION SPEED CORRESPONDING TO THE AVERAGE BLOOD PRESSURE OF HUMAN BODY OF 10.6KPA, 16KPA AND 21.3KPA.
4. A FIXED TARGET PLATE IS SET TO BLOCK THE HIGH-PRESSURE EDGE PART OF THE INJECTED LIQUID FLOW AND ONLY ALLOW THE STEADY FLOW PART TO BE SPRAYED ON THE SAMPLE, WHICH INCREASES THE ACCURACY AND REPEATABILITY OF THE LIQUID VELOCITY SPRAYED ON THE SAMPLE.
STANDARDS:
MEDICAL RESPIRATOR TECHNICAL REQUIREMENTS, 5.5 SYNTHETIC BLOOD PENETRATION BARRIER PERFORMANCE
YY/T 0691-2008 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK RESISTANCE TO SYNTHETIC BLOOD PENETRABILITY TEST METHOD (FIXED VOLUME, HORIZONTAL INJECTION)
YY 0469-2011 MEDICAL SURGICAL MASK TECHNOLOGY REQUIRES A BLOOD PENETRATION TEST DEVICE
ISO 22609:2004 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK TEST METHOD FOR RESISTANCE TO SYNTHETIC BLOOD PENETRATION (FIXED VOLUME, HORIZONTAL INJECTION)
ASTM F1862-07 STANDARD TEST METHOD FOR RESISTANCE OF MEDICAL FACE MASKS TO BLOT BY SYNTHETIC BLOOD (HORIZONTAL PROJECTION OF FIXED VOLUME AT A KNOW VELOCITY)
TECHNICAL PARAMETERS:
1. INJECTION DISTANCE: 300mm ~ 305mm ADJUSTABLE
2. NOZZLE DIAMETER: 0.84mm
3. INJECTION SPEED: 450CM/S, 550CM/S, 635CM/S
4. WEIGHT: 35KG
5. POWER SOURCE: AC220V 50HZ
QUANTITY: 1
Learn More - V-0025 COTTON PAD, BALL, SWAB MACHINESREFERENCE NUMBER: V-0025 COTTON PAD, BALL, SWAB MACHINES M-5138 SQUARE COTTON PAD PRODUCTION MACHINE M-5139 COTTON GAUZE PAD PRODUCTION MACHINE M-5140 MACHINE TO PRODUCE VARIOUS TYPES OF COTTON PADS M-5141 COTTON PAD PRODUCTION MACHINE M-5142 MAKEUP REMOVING COTTON PAD PRODUCTION MACHINE M-5143 ROUND COTTON PAD MAKING MACHINE M-5144 SQUARE ABSORBENT COTTON PAD PRODUCTION MACHINE M-5145 ROUND ABSORBENT COTTON PAD PRODUCTION MACHINE M-5146 ROUND COTTON PADS MAKING MACHINE M-5147 COTTON PAD MAKING MACHINE M-5148 COTTON PAD MAKING MACHINE M-5168 COTTON PADS MAKING MACHINE M-5169 COTTON Q-TIP MAKING MACHINE (100PCS/BAG) M-5170 COTTON BALL MAKING MACHINE (NEW) M-5171 COSMETIC COTTON PAD (GLOVE SHAPE) MAKING MACHINE M-5172 COSMETIC COTTON PAD MAKING MACHINE (ROUND PAD) M-5101 MEDICAL COTTON BALL MAKING MACHINE 20KG/HOUR QUANTITY AVAILABLE: 17 Learn More
- V-1884 CONVOLUTER, 27 INCHES WIDE (686mm WIDE), 7.5HP WAS USED FOR MEDICAL FOAMV-1884 CONVOLUTER, 27 INCHES WIDE (686mm WIDE), 7.5HP WAS USED FOR MEDICAL FOAM DIMENSIONS OF THE HEADS 15/16 INCHES (23.81mm) QUANTITY: 1 Learn More
- M-5138 SQUARE COTTON PAD PRODUCTION MACHINEREFERENCE NUMBER: M-5138 (12121745V11UX) L SQUARE COTTON PAD PRODUCTION MACHINE MODEL: XF SPEED: 1800 TO 3000 PCS/MINUTE PRODUCT SIZE: WIDTH: 40 TO 100mm, LENGTH 40 TO 100mm RAW MATERIAL SIZE: 1000mm, DIAMETER LESS THAN 1000mm POWER: 380V FREQUENCY: 50 HZ TOTAL POWER: 4.5KW DIMENSION: LENGTH: 2500mm, WIDTH: 1900mm, HEIGHT: 1600mm WEIGHT: 2500KG QUANTITY AVAILABLE: 1 Learn More
- AA-1153 MASK FILM PACKING MACHINE, UP TO 110 MASKS PER MINUTEAA-1153 MASK FILM PACKING MACHINE, UP TO 110 MASKS PER MINUTE 1. MAXIMUM PRODUCT LENGTH: 220mm 2. MAXIMUM PRODUCT WIDTH: 120mm 3. PACKAGING PRODUCT HEIGHT: 45mm 4. PACKING SPEED: 30 TO 110 BAGS PER MINUTE 5. PACKAGING FILM MAXIMUM WIDTH: 440mm 6. WEIGHT: 900 KGS QUANTITY: 1 Learn More
- Z-1613 AUTOMATIC CARTON PACKAGING MACHINEZ-1613 AUTOMATIC CARTON PACKAGING MACHINE CARTONING FORM: HORIZONTAL CARTONING CARTONING SPEED: 30 TO 40 BOXES PER MINUTE (DEPENDING ON CARTON DIMENSIONS) PROCESS REQUIREMENTS: -AUTOMATIC BOX OPENING, CARTONING -GLUE SPRAYING -BOX SEALING VOLTAGE: 220 VOLTS, 60Hz PLC MICRO COMPUTER FULL AUTOMATIC CONTROL MAN-MACHINE INTERFACE OPERATION SYSTEM (HMI), AUTOMATICALLY DISPLAYS THE PACKING SPEED, QUANTITY, FAULT REASON AND OTHER PERFORMANCE PARAMETERS. THE INDENTATION OF THE CARTON IS GENERALLY: 0.4mm DEEP QUANTITY: 1 Learn More
- V-1820 MASK AND RESPIRATOR FIELD TESTER
MAINLY USED FOR VISUAL FIELD TESTING OF MASKS AND RESPIRATORS, WHICH IS USEFUL FOR MASK AND RESPIRATOR MANUFACTURERS, QUALITY SUPERVISORS, SCIENTIFIC RESEARCH, AND FOR TESTING PRIOR TO SELLING MASKS.
FEATURES:
1. THE EQUIPMENT IS COMPOSED OF A SEMI-ARC BOW, RECORDING DEVICE, SEAT FRAME AND TEST HEAD DIE.
2. SEMI-ARC BOW: THE RADIUS IS 300 TO 340 mm
CAN BE ROTATED AROUND THE HORIZONTAL RADIUS PLANE PASSING THROUGH THE POINT 0°, AND A SCALE EXTENDING TO THE 90° ARC BOW EVERY 5° FROM 0° ON BOTH SIDES, EQUIPPED WITH SLIDING WHITE VISUAL STANDARD.
3. RECORDING DEVICE: THE RECORDING NEEDLE IS CONNECTED WITH THE VISUAL STANDARD THROUGH COMPONENTS SUCH AS AXLE WHEEL, AND THE DIRECTION AND ANGLE OF THE VISUAL STANDARD ARE RECORDED ON THE VISUAL FIELD DRAWING CORRESPONDINGLY.
4. SEAT FRAME: USED TO SUPPORT SEMI-CIRCULAR ARC BOW AND FIXED RECORDING DEVICE.
5. TEST THE HEAD MOLD: A STANDARD HEAD MOLD, THE TWO EYE HOLES OF THE HEAD MOLD ARE EQUIPPED WITH SMALL LIGHT BULBS, THE POSITION OF THE BULB AND THE POSITION OF THE HEAD MOLD ARE ACCORDING TO THE REQUIREMENTS OF GB 2890. THE TEST HEAD DIE MUST BE INSTALLED ON THE WORKBENCH IN SUCH A WAY THAT THE LEFT AND RIGHT EYES ARE PLACED AT THE CENTER OF THE SEMICIRCULAR ARCH AND THE "0" POINT IS DIRECTLY SEEN.MAIN INDICATORS
Learn More
1. SEMI-CIRCULAR ARC RADIUS: 335mm.
2. LEFT AND RIGHT FIELD OF VIEW: ≤120°.
3. BULB DISTANCE: THE VERTEX OF THE BULB IS CONNECTED AFTER THE TWO EYE POINTS (7±0.5).
APPLICABLE STANDARDS: GB/T 32610-2016, GB 2626-2019, GB2890-2009 - J-2792 MEDICAL FACE MASK SYNTHETIC BLOOD PENETRATION TESTER
USED FOR MEASURING THE RESISTANCE OF MEDICAL FACE MASKS TO PENETRATION BY A SPLASH OF SYNTHETIC BLOOD
BLOOD SPRAYING DISTANCE: 300 TO 310mm (APPROXIMATE, ADJUSTABLE)
NEEDLE INNER DIAMETER: 0.84mm
SPRAY SPEED: 4500mm PER SECOND, 5500mm PER SECOND, 6350mm PER SECOND
SIMULATED SYNTHETIC BLOOD PRESSURE: 10.6kPa, 16.0 kPa, 21.3 kPa, (i.e. 80mmHg, 120mmHg, 160mmHg)
SUPPORTS THE SPECIMEN MEDICAL FACE MASK ON THE TESTER’S CLAMPING DEVICE AND SPRAYS A FIXED VOLUME (~2ml) OF SYNTHETIC BLOOD SPLASHED HORIZONTALLY TO HIT THE MASK
TESTER CAN PROVIDE DIFFERENT BLOOD PRESSURES WITH PRECISION CONTROL VALVE TO GENERATE 2ml SYNTHETIC BLOOD WITH SURFACE TENSION OF 0.042 ± 0.002 N/m, WHICH MEETS THE REQUIREMENTS DEFINED IN STANDARDS BELOW:
ISO 22609
ASTM F1862
YY 0469-2011
GB/T 19083-2010LEAD TIME: 5 TO 7 WEEKS FROM RECEIPT OF ORDER
QUANTITY: 1
Learn More - M-5144 SQUARE ABSORBENT COTTON PAD PRODUCTION MACHINEREFERENCE NUMBER: M-5144 (1212HNBGXX11) L SQUARE ABSORBENT COTTON PAD PRODUCTION MACHINE SQUARE COTTON PAD MACHINE IS USED TO PRODUCE THE COSMETIC COTTON PAD OR MAKE-UP REMOVER PAD ALL PROCESSES ARE FULLY AUTOMATIC, FROM RAW MATERIAL FEEDING, CONVEYING, EMBOSSING, VERTICAL CUTTING, HORIZONTAL CUTTING, TO FINAL PRODUCTS THE EMBOSSING DESIGN AND COTTON PAD SIZE CAN BE CUSTOMIZED AUTOMATIC COUNTING FUNCTION SAVES LABOR COST AND TIME MODEL: C7 RAW MATERIALS: COTTON PAD ROLL POWER SUPPLY: 380V, 50/60HZ POWER CONSUMPTION: 3.0KW AIR SUPPLY: N/A PRODUCTION SPEED: 1000 TO 1800 PIECES PER MINUTE MACHINE DIMENSION: (L2100 x W1700 x H1500) mm GROSS WEIGHT: 1100KG LABOR REQUIRED: 1 PRODUCTION AREA REQUIRED: ABOUT 15M2 QUANTITY: 1 Learn More