Search results for: '1500 kg'
- Related search terms
- 1500
- 1500/2003
- 1500 kg/
- 1500 kg/hr soap
- 1500 kg/hr soap finishing
- R-7071 COFFEE ROASTING MACHINE (INDUSTRIAL) 830N
R-7071 COFFEE ROASTING MACHINE (INDUSTRIAL) 830N
POWER CONSUMPTION: 5500 WATTS
BAKING CAPACITY: 30 KG
NUMBER OF BAKING DRUMS: FREE TO ADJUST (UP TO 90 RPM)
NUMBER OF COOLING SLOTS: 15 TURNS
HEATING METHOD: BARREL GAS OR NATURAL GAS
BAKING METHOD: SEMI-HOT AIR TYPE
BAKING TIME: GENERALLY ABOUT 15 MINUTES
PRODUCT DIMENSIONS (L X W X H): 2800 X 1500 X 2900mm
CAST IRON INNER POT
STRONG COOLING TROUGH
CAN ACCURATELY CONTROL THE GAS FLOW
BUILT-IN AUTOMATIC SAFETY IGNITION SYSTEM (OVER-TEMPERATURE. POWER OFF. WHEN THE FLAME CAN AUTOMATICALLY CUT OFF THE GAS SOURCE
BUILT-IN USB OUTPUT CABLE, CAN BE CONNECTED TO THE COMPUTER AND RECORD BAKING INFORMATION
BUILT-IN BAKING DRUM SPEED DISPLAY TABLE
12-STAGE DAMPER FINE-TUNING
OPTIONAL EGG BEANS AUTOMATIC FEEDING
MACHINE OPTIONAL COFFEE HOT BEAN SORTING (STONE AND IRON CAN BE REMOVED)QUANTITY: 1
Learn More - R-3250 GIESEN COFFEE ROASTER AND SELKIRK OXIDIZER - 15 KILOS
R-3250 GIESEN COFFEE ROASTER AND SELKIRK OXIDIZER - 15 KILOS
AN EXCEPTIONAL OPPORTUNITY FOR READY TO BE DELIVERED/INSTALLED EQUIPMENT CREATED BY A CHANGED BUSINESS MODEL.
GIESEN W15A
DOUBLE EXHAUST/ROAST PROFILE SYSTEM
NATURAL GAS
240V/60 HZ
COLOR: RED
AVAILABLE WITH SELKIRK TO-2CS321 THERMAL OXIDIZER (USED)GIESEN BROCHURE
SPECIFICATIONS:
GIESEN W15A
CAPACITY: 500 GRAM - 15 KG GREEN BEANS / PER BATCH / M. 60 KG/H
DRIVES: DIRECT FREQUENCY DRIVE MOTOR. ADJUSTABLE DRUM SPEED CONTROL AND ADJUSTABLE ROAST FAN SPEED CONTROL.
ROAST DRUM: DIGITAL PRESSION CONTROL. CAST IRON DRUM WITH HIGH PERFORMANCE BEARINGS.
HEATING SYSTEM: GAS BURNER BY PROPANE GAS (LPG, BOTTLE GAS) OR CITY GAS.
VOLTAGE: 1 PHASE 230V / 50-60 HZ
PAINTING: FREE CHOICE AND CUSTOMIZED / RAL CODES
ROAST ROOF: FREE CHOICE AND CUSTOMIZED
DIMENSIONS: LENGTH 1900mm X WIDTH 962mm X HEIGHT 2000mm
EXHAUST PIPE: EXHAUST PIPE DIAMETER FOR ROAST AIR: ∅ 200mmTHERMAL OXIDIZER FOR GIESEN W15 ROASTER
SELKIRK SPECIALIZES IN THERMAL AFTERBURNERS FOR COFFEE ROASTING MACHINES FROM 10 TO 120 KGS PER BATCH. AFTERBURNERS ARE DESIGNED OF QUALITY MATERIALS FOR LONG SERVICE LIFE. INTEGRATED EFFICIENT GAS BURNERS WHICH REDUCE OPERATING COSTS. BURNER CONFORMS TO UL 295 STANDARD FOR COMMERCIAL/INDUSTRIAL GAS BURNERS. AFTERBURNER DESIGN PROVIDES LONG RETENTION TIMES TO ELIMINATE SMOKE AND ODORS FROM THE ROASTING PROCESS. STANDARD AFTERBURNER OPERATING TEMPERATURE IS 1250 F, BUT CAN EASILY BE ADJUSTED TO MEET LOCAL AIR QUALITY REQUIREMENTS. GAS BURNER IS COMPLETELY SELF MODULATING, AND OPERATOR CONTROLS ARE DESIGNED FOR EASE OF USE.OXIDIZER SPECIFICATIONS:
TO-2CS321 THERMAL OXIDIZER WITH THE FOLLOWING DESIGN FEATURES:
WAYNE COMBUSTION LC 1500 BURNER WITH 1.5 MILLION BTU PER HOUR MAXIMUM INPUT.
DUNGS MULTIBLOC SAFETY VALVE MBC VEF 2500.
DUNGS LOW AND HIGH GAS PRESSURE SWITCHES.
SIEMENS LME SERIES FLAME SAFETY CONTROLLER.
FLAME SENSING ROD FOR FLAME VERIFICATION.
FULLY MODULATING TO MODULATE AT PRE-SET OPERATING TEMPERATURE;
BURNER AND CONTROLS CONFORM TO UL 295 STANDARD FOR COMMERCIAL INDUSTRIAL GAS HEATING EQUIPMENT.
OPERATOR FRIENDLY CONTROL SYSTEM.
TO-2CS321 DIMENSIONS:
OUTSIDE DIAMETER: 36"
OVERALL HEIGHT FROM FLOOR: 82"
INLET DIAMETER: 6"
OUTLET DIAMETER: 10"
EXTERIOR TO BE POWDERCOATED CARBON STEEL MATTE BLACK (OPTIONAL COLORS AVAILABLE).
4" OF HIGH DENSITY CERAMIC INSULATION BETWEEN INTERIOR AND EXTERIOR SURFACES.QUANTITY: 1
Learn More - R-3249 GIESEN COFFEE ROASTER W15A SELKIRK OXIDIZER - 15 KILOS
R-3249 GIESEN COFFEE ROASTER W15A SELKIRK OXIDIZER - 15 KILOS
AN EXCEPTIONAL OPPORTUNITY FOR READY TO BE DELIVERED/INSTALLED EQUIPMENT CREATED BY A CHANGED BUSINESS MODEL.
NATURAL GAS
240V/60 HZ
BLACK/SILVERSELKIRK SPECIALIZES IN THERMAL AFTERBURNERS FOR COFFEE ROASTING MACHINES FROM 10 TO 120 KGS PER BATCH. AFTERBURNERS ARE DESIGNED OF QUALITY MATERIALS FOR LONG SERVICE LIFE. INTEGRATED EFFICIENT GAS BURNERS WHICH REDUCE OPERATING COSTS. BURNER CONFORMS TO UL 295 STANDARD FOR COMMERCIAL/INDUSTRIAL GAS BURNERS. AFTERBURNER DESIGN PROVIDES LONG RETENTION TIMES TO ELIMINATE SMOKE AND ODORS FROM THE ROASTING PROCESS. STANDARD AFTERBURNER OPERATING TEMPERATURE IS 1250 F, BUT CAN EASILY BE ADJUSTED TO MEET LOCAL AIR QUALITY REQUIREMENTS. GAS BURNER IS COMPLETELY SELF MODULATING, AND OPERATOR CONTROLS ARE DESIGNED FOR EASE OF USE.
OXIDIZER SPECIFICATIONS:
TO-2CS321 THERMAL OXIDIZER WITH THE FOLLOWING DESIGN FEATURES:
WAYNE COMBUSTION LC 1500 BURNER WITH 1.5 MILLION BTU PER HOUR MAXIMUM INPUT.
DUNGS MULTIBLOC SAFETY VALVE MBC VEF 2500.
DUNGS LOW AND HIGH GAS PRESSURE SWITCHES.
SIEMENS LME SERIES FLAME SAFETY CONTROLLER.
FLAME SENSING ROD FOR FLAME VERIFICATION.
FULLY MODULATING TO MODULATE AT PRE-SET OPERATING TEMPERATURE;
BURNER AND CONTROLS CONFORM TO UL 295 STANDARD FOR COMMERCIAL INDUSTRIAL GAS HEATING EQUIPMENT.
OPERATOR FRIENDLY CONTROL SYSTEM.
TO-2CS321 DIMENSIONS:
OUTSIDE DIAMETER: 36"
OVERALL HEIGHT FROM FLOOR: 82"
INLET DIAMETER: 6"
OUTLET DIAMETER: 10"
EXTERIOR TO BE POWDERCOATED CARBON STEEL MATTE BLACK (OPTIONAL COLORS AVAILABLE).
4" OF HIGH DENSITY CERAMIC INSULATION BETWEEN INTERIOR AND EXTERIOR SURFACES.QUANTITY: 1
Learn More