Search results for: 'can c'
-
TT-1038 TENSILE STRENGTH TESTING INSTRUMENTSTT-1038 TENSILE STRENGTH TESTING INSTRUMENTS KEY SPECIFICATIONS MAX. CAPACITY: 50KN CONTROL MODE: COMPUTER CONTROL, COMPUTER AND TOUCH SCREEN CONTROL FORCE RESOLUTION: 1/100,000 FORCE ACCURACY: ≤+/-0.5% STROKE RESOLUTION: 0.001mm EXTENSOMETER RESOLUTION: 0.001mm TEST SPEED: 0.001-500mm/MIN WALKING SPACE: 1500mm (IT CAN BE CUSTOM-TAILOR ACCORDING TO THEIR REQUIREMENTS) FORCE UNIT SWITCH: KGF, N, IBF, G, TON, MPA STOP MODE: OVERLOAD STOP, EMERGENCY STOP BUTTON, SPECIMEN DAMAGE AUTOMATIC STOP, UPPER & LOWER LIMIT SET AUTOMATIC STOP, AUTOMATIC RESET FUNCTION MACHINE DRIVE: SERVO MOTOR DRIVE, SYNCHRONOUS WHEEL AND PRECISION BALL SCREW DRIVE POWER SUPPLY: AC 220V 50/60Hz 10A DIMENSIONS: 750 X 700 X 1700mm (W X D X H) WEIGHT: 300KG QUANTITY: 1 Learn More -
TT-1041UNIVERSAL TENSILE STRENGTH TESTER, 50KNTT-1041UNIVERSAL TENSILE STRENGTH TESTER, 50KN 50KN TENSILE STRENGTH TEST KEY SPECIFICATIONS: CAPACITY KGF 5000, 10000, 15000 KN 50, 100, 150 UNIT: LOAD N, KN, G, KG, TON, LB DISPLACEMENT: mm, CM, INCH LOAD RESOLUTION: 1/20,000 LOAD ACCURACY: ±1% (±0.5% OPTIONAL) LOAD AMPLIFICATION: X 1, X 2, X 5, X 10 AUTO RANGE TESTING WIDTH (mm): 800 CROSSHEAD TRAVEL (mm): 1480 TESTING STROKE: CROSSHEAD TRAVEL MINUS UPPER/LOWER GRIPS AND GRIPPING LENGTH TEST SPEED RANGE (mm/MIN): 0.5~500 OR 0.2~200 MAXIMUM FORCE AT FULL SPEED (KGF): 2000 MAXIMUM SPEED AT FULL LOAD (mm/MIN): 100 SPEED ACCURACY: ±0.5% SERVO CONTROL DISPLACEMENT RESOLUTION (mm): 0.001 DRIVING METHOD: AC SERVO MOTOR POWER: SPECIFICATIONS 3Ø, 220VAC, 50/60Hz (380/415V OPTIONAL) CAPACITY: 5000KGF, 10000KGF, 15000KGF 50KN, 100KN, 150KN CONSUMPTION: 3KVA DIMENSIONS: FRAME (mm) 1540 X 600 X 2130 CONTROL BOX (mm): COMPUTER TYPE 1200 X 600 X 740 MICRO-COMPUTER TYPE 660 X 600 X 740 WEIGHT (KG): FRAME 800, CONTROL BOX 100 STANDARD ACCESSORIES: TENSILE GRIPS X 1 SET, NECESSARY TOOLS X 1 SET, OPERATIONAL MANUAL X 1 COPY, CERTIFICATE OF CALIBRATION X 1 COPY QUANTITY: 1 Learn More -
T-6550 MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTERREFERENCE NUMBER: T-6550
MEDICAL PROTECTIVE CLOTHING BLOOD SYNTHETIC PENETRABILITY TESTER
TECHNICAL SPECIFICATIONS AND CONFIGURATION:
1. THE INSTRUMENT ADOPTS AN AIR SOURCE THAT CAN PROVIDE (0.5 ~ 30±0.1) KPA PRESSURE TO CONTINUOUSLY PRESSURIZED THE SAMPLE, WHICH IS NOT RESTRICTED BY THE SPACE OF THE TEST SITE;
2. THE AIR PRESSURE RANGE CAN BE ADJUSTED FREELY, AND THE ADJUSTMENT RANGE (0.5 ~ 30) KPA;
3. COLOR TOUCH SCREEN DISPLAY AND OPERATION;
4. THE SAMPLE CLAMPING PAD IS PROCESSED WITH IMPORTED SPECIAL ALUMINUM PROFILES, WHICH IS LIGHT IN MATERIAL, CLEAN IN SURFACE AND NEVER RUSTS.
5. THE INSTRUMENT ADOPTS IMPORTED SPECIAL ALUMINUM WIRE DRAWING PANEL, EQUIPPED WITH METAL KEYS, SENSITIVE OPERATION, NOT EASY TO DAMAGE;
6. CLAMPING DEVICE FOR INSTRUMENT SAMPLES, EQUIPPED WITH LOCKING PROTECTION, TO PREVENT THE SYNTHETIC BLOOD FROM SPLASHING AROUND;
7. CLAMPING FORCE IS ACCURATE AND RELIABLE;
8. THE TEST TANK IS EQUIPPED WITH A SPECIAL PLACEMENT DEVICE, WHICH IS CONVENIENT FOR CUSTOMERS TO OPERATE;
9. THE TEST TANK IS PROCESSED WITH SPECIAL 316 STAINLESS STEEL, AND THE TOP IS EQUIPPED WITH A SPECIAL COVER FOR HIGH TRANSPARENT PROTECTION;
10. THE WASHER BELOW THE SAMPLE IS MADE OF HIGH-QUALITY PTFE MATERIAL AFTER SPECIAL PROCESSING;
11. SQUARE METAL BLOCK NET: OPEN SPACE ≥50°%; BENDING ≤5mm AT 30KPA;
12. INSTRUMENT TIME CONTROL ACCURACY ≤01 SECONDS;
13. THE SHELL OF THE INSTRUMENT IS MADE OF HIGH-QUALITY METAL BAKING PAINT, WHICH IS BEAUTIFUL AND GENEROUS.
14. EQUIPPED WITH PRINTER INTERFACE, CONNECTED TO THE PRINTER CAN DIRECTLY PRINT DATA REPORTS.
TECHNICAL PARAMETERS:
1. SAMPLE SIZE: 75mm X 75mm
2. TEST AREA: 28.26 SQUARE CENTIMETERS
3. AIR PRESSURE ADJUSTMENT RANGE (0.5 ~ 30) KPA
4. EXTERNAL SIZE: 500mm X 500mm X 500mm (L X W X H)
5. WEIGHT OF THE INSTRUMENT: 40 KG
6. POWER SUPPLY: AC220V, 50HZ,SCOPE OF SUPPLY: 1. ONE MAIN MACHINE; 2. TWO PTFE GASKETS; 3. TWO ORDINARY WASHERS; 4. ONE METAL BLOCKING NET; 5. A SET OF SPECIAL LOCKING TOOLS; 6. ONE HIGH-QUALITY SILENT AIR PUMP, [NOTE: SAFETY PRODUCTION LICENSE IS NOT INCLUDED]. 7. EQUIPPED WITH PRINTER INTERFACE; 8. ONE SAMPLE TEMPLATE; 9. ONE PRODUCT CERTIFICATE; 10. ONE COPY OF PRODUCT OPERATION MANUAL.
OPERATION INSTRUCTION:
INSERT THE AIR PUMP OUTPUT PIPE INTO THE OIL AND WATER SEPARATOR OF THE INSTRUMENT AS REQUIRED (PRESSURE 0.1-0.3MPA).
AFTER SWITCHING ON THE POWER, THE STARTUP INTERFACE (NAME OF THE DEVICE) IS DISPLAYED.
PRESS THE "ENTER" BUTTON TO ENTER THE TEST INTERFACE, AS SHOWN IN THE FOLLOWING FIGURE:
CLICK "SETTING” BUTTON, GET INTO PARAMETER SETTING SCREEN, AS BELOW THIS SCREEN CAN SET THE SYSTEM TIME, DATE AND TESTING TIME, AFTER SETTING, CLICK "SAVE” BUTTON TO KEEP THE SETTING DATA. (NOTE: IT REQUIRES 5 MINUTES IN THE STANDARD)
QUANTITY: 1
Learn More -
T-9597 FABRIC BURSTING STRENGTH TESTERT-9597 FABRIC BURSTING STRENGTH TESTER KEY SPECIFICATION: RANGE: 2.00MPA TO 10.000MPA THE MIN. DIVISION VALUE: 0.001MPA TO 0.003MPA TEST AREA: 73mm2 (Φ30.5mm), 100mm2 (Φ35.7mm), 500mm2 (Φ79.8mm), 1000mm2 (Φ112.8mm) CAN BE OPTION THICKNESS OF RUBBER DIAPHRAGM: ≤2mm PRESSURE SPEED: 20ML/MIN - 600ML/MIN MAXIMUM EXPANSION HEIGHT: 75 ± 0.02mm TESTING UNITS: KPA, KGF/ CM2, ATM, MMHG, LB/IN2 FREE SHIFT TEST METHOD: CONSTANT RATE BURSTING CONSTANT EXPANSION CONSTANT PRESSURE CONSTANT TIME BURSTING OUTPUT: PRINTER, DISPLAY OUTPUT AND CAN BE CONNECTED TO THE COMPUTER POWER SUPPLY: AC 220V 50/60HZ 200W DIMENSIONS: 550 × 450 × 700mm NET WEIGHT: 125KG Learn More -
TT-1040 COMPUTERIZED TENSILE TESTING MACHINE, 150KNTT-1040 COMPUTERIZED TENSILE TESTING MACHINE, 150KN COMPUTERIZED TENSILE TESTING MACHINE KEY SPECIFICATION: CAPACITY: KGF 3000, 5000, 10000, 15000 KN 30, 50, 100, 150 UNIT: LOAD N, KN, G, KG, TON, LB DISPLACEMENT: mm, CM, INCH LOAD RESOLUTION: 1/20,000 LOAD ACCURACY: ±1% (±0.5% OPTIONAL) LOAD AMPLIFICATION: X 1, X 2, X 5, X 10 AUTO RANGE TESTING WIDTH (mm): 560 (800 OPTIONAL) CROSSHEAD TRAVEL (mm): 980 (1480 OPTIONAL) TESTING STROKE: CROSSHEAD TRAVEL MINUS UPPER/LOWER GRIPS AND GRIPPING LENGTH TEST SPEED RANGE (mm/MIN): 0.5~500 OR 0.2~200, 0.2~200 OR 0.5~500 MAXIMUM FORCE AT FULL SPEED (KGF): 1000, 2000 MAXIMUM SPEED AT FULL LOAD (mm/MIN): 100, 50 SPEED ACCURACY: ±0.5% SERVO CONTROL DISPLACEMENT RESOLUTION: 0.001 DRIVING METHOD: AC SERVO MOTOR POWER SPECIFICATIONS: 3Ø, 220VAC, 50/60Hz (380/415V OPTIONAL) CONSUMPTION: 3000 KGF 30 KN 5000 KGF 50 KN 10000 KGF 100 KN 15000 KGF 150 KN 2 KVA, 3 KVA, 5 KVA, 10 KVA DIMENSIONS FRAME (mm): 1300 X 600 X 2130 1540 X 600 X 2130 1300 X 600 X 2630 1540 X 600 X 2630 CONTROL BOX (mm) COMPUTER TYPE 1200 X 600 X 740 MICRO-COMPUTER TYPE 660 X 600 X 740 WEIGHT (KG) FRAME 800, CONTROL BOX 100 FRAME 1200, CONTROL BOX 100 STANDARD ACCESSORIES: TENSILE GRIPS X 1 SET, NECESSARY TOOLS X 1 SET, OPERATIONAL MANUAL X 1 COPY, CERTIFICATE OF CALIBRATION X 1 COPY Learn More -
T-6544 SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASKREFERENCE NUMBER: T-6544
SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
TECHNICAL INDICATORS:
1. THE PROTRUDING SAMPLE FIXING DEVICE CAN SIMULATE THE ACTUAL USE STATE OF THE MASK, SET ASIDE THE TEST TARGET AREA WITHOUT DESTROYING THE SAMPLE, AND DISTRIBUTE THE SYNTHETIC BLOOD IN THE TARGET AREA OF THE SAMPLE.
2. THE SPECIAL FIXED-PRESSURE INJECTION DEVICE CAN EJECT A CERTAIN VOLUME OF SYNTHETIC BLOOD IN A CONTROLLED TIME.
3. IT CAN FULLY SIMULATE THE INJECTION SPEED CORRESPONDING TO THE AVERAGE BLOOD PRESSURE OF HUMAN BODY OF 10.6KPA, 16KPA AND 21.3KPA.
4. A FIXED TARGET PLATE IS SET TO BLOCK THE HIGH-PRESSURE EDGE PART OF THE INJECTED LIQUID FLOW AND ONLY ALLOW THE STEADY FLOW PART TO BE SPRAYED ON THE SAMPLE, WHICH INCREASES THE ACCURACY AND REPEATABILITY OF THE LIQUID VELOCITY SPRAYED ON THE SAMPLE.
STANDARDS:
MEDICAL RESPIRATOR TECHNICAL REQUIREMENTS, 5.5 SYNTHETIC BLOOD PENETRATION BARRIER PERFORMANCE
YY/T 0691-2008 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK RESISTANCE TO SYNTHETIC BLOOD PENETRABILITY TEST METHOD (FIXED VOLUME, HORIZONTAL INJECTION)
YY 0469-2011 MEDICAL SURGICAL MASK TECHNOLOGY REQUIRES A BLOOD PENETRATION TEST DEVICE
ISO 22609:2004 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK TEST METHOD FOR RESISTANCE TO SYNTHETIC BLOOD PENETRATION (FIXED VOLUME, HORIZONTAL INJECTION)
ASTM F1862-07 STANDARD TEST METHOD FOR RESISTANCE OF MEDICAL FACE MASKS TO BLOT BY SYNTHETIC BLOOD (HORIZONTAL PROJECTION OF FIXED VOLUME AT A KNOW VELOCITY)
TECHNICAL PARAMETERS:
1. INJECTION DISTANCE: 300mm ~ 305mm ADJUSTABLE
2. NOZZLE DIAMETER: 0.84mm
3. INJECTION SPEED: 450CM/S, 550CM/S, 635CM/S
4. WEIGHT: 35KG
5. POWER SOURCE: AC220V 50HZ
QUANTITY: 1
Learn More -
TT-1047 MICRO COMPUTER TENSILE STRENGTH TESTING MACHINETT-1047 MICRO COMPUTER TENSILE STRENGTH TESTING MACHINE TENSILE COMPRESSION TESTING MACHINE KEY SPECIFICATIONS CAPACITY: 50N, 100N, 200N, 500N, 1KN, 2KN,2.5KN DISPLAY: LCD DISPLAY FORCE RESOLUTION: 1/50,000 FORCE ACCURACY: ≤+/-0.5% STROKE RANGE: 1100mm (EXCLUDE THE GRIPS) STROKE RESOLUTION: 0.001mm TEST SPEED: 0.001-500mm/MIN CAN BE SET, WITH UP & DOWN FAST ADJUSTMENT BUTTON OF GRIPS FORCE UNIT SWITCH: KGF, N, IBF, G, TON, MPA STOP MODE: OVERLOAD STOP, EMERGENCY STOP BUTTON. SPECIMEN DAMAGE AUTOMATIC STOP MACHINE DRIVE: AC INVERTER MOTOR DRIVE POWER SUPPLY: AC 220V 50-60Hz 5A DIMENSIONS: 470 X 380 X 1860mm WEIGHT: 60KG QUANTITY: 1 Learn More -
T-6545 MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTERREFERENCE NUMBER: T-6545
MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTER
PRODUCT INTRODUCTION:
MASK BACTERIA FILTRATION EFFICIENCY KEY PERFORMANCE INDICATORS (BFE) DETECTOR TESTER NOT ONLY CONFORMS TO THE REQUIREMENTS OF MEDICAL SURGICAL MASKS TECHNOLOGY YY0469-2011 APPENDIX B IN THE TEST METHOD FOR FILTER EFFICIENCY (BFE) BACTERIA FIRST B. 1.1.1 TEST INSTRUMENT, BUT ALSO CONFORMS TO THE AMERICAN SOCIETY FOR TESTING MATERIAL ASTMF2100, ASTMF2101, THE REQUIREMENTS OF THE EUROPEAN EN14683 STANDARDS, INNOVATIVE IMPROVEMENTS WERE MADE ON THE BASIS OF THIS, WITH DOUBLE PNEUMATIC CONTRAST SAMPLING METHOD AT THE SAME TIME, IMPROVE THE PRECISION OF SAMPLING,IT IS SUITABLE FOR MEASURING AND TESTING DEPARTMENTS, SCIENTIFIC RESEARCH INSTITUTES, MASK MANUFACTURERS AND OTHER RELEVANT DEPARTMENTS TO TEST THE PERFORMANCE OF MASK BACTERIAL FILTRATION EFFICIENCY.
EXECUTION STANDARD:
Q/0212 ZRB003-2015 MEDICAL SURGICAL MASK
BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR RELATED INTELLECTUAL PROPERTY:
NO.: ZL200820224142.6 ELECTRIC FLOW CONTROL VALVE
NO.: ZL200820224143.0 GAS CAPACITY
NO.: ZL200920308391.8 AIR FILTRATIONMATERIAL FILTRATION EFFICIENCY DETECTOR
PRODUCT FEATURES:
NEGATIVE PRESSURE TEST SYSTEM TO ENSURE THE SAFETY OF OPERATORS;
BUILT -IN PERISTALTIC PUMP IN NEGATIVE PRESSURE CABINET, A, B TWO -WAY, SIX ANDERSEN; THE PERISTALTIC PUMP FLOW CAN BE SET;
THE FLOW RATE OF NIGHT SPRAY CAN BE SET AND THE ATOMIZATION EFFECT IS GOOD.
EMBEDDED HIGH SPEED INDUSTRIAL MICROCOMPUTER CONTROL; 10.4 INCHES INDUSTRIAL HIGH BRIGHTNESS COLOR TOUCH SCREEN;
USB INTERFACE, SUPPORT U DISK DATA STORAGE;
CABINET BUILT-IN HIGH BRIGHTNESS LIGHTS; BUILT-IN LEAKAGE PROTECTION SWITCH TO PROTECT THE SAFETY OF OPERATORS;
THE INNER LAYER OF THE CABINET IS MADE OF STAINLESS STEEL, THE OUTER LAYER IS SPRAYED WITH PLASTIC AND COLD-ROLLED, AND THE INNER AND OUTER LAYERS ARE INSULATED AND FLAME RETARDANT.
THE FRONT SWITCH TYPE GLASS DOOR IS CONVENIENT FOR THE EXPERIMENTER TO OBSERVE AND OPERATE.
DETACHABLE BRACKET, ADJUSTABLE BRACKET HEIGHT; SUPPORTING AND MOVING DUAL PURPOSE CASTERS.
QUANTITY: 1
Learn More -
HUMAN BODY ELEMENTS ANALYSIS MACHINEREFERENCE NUMBER: Y-2080 HUMAN BODY ELEMENTS ANALYSIS MACHINE HUMAN BODY ELEMENTS ANALYSIS EQUIPMENT, APPLIES THE ACCURATE MEASUREMENTS OF AVR MICROCOMPUTER CONTROLLER BASE ON NEW STATIC METHOD DXA, ANALYSIS HUMAN ELEMENTS, FAT WEIGHT BMI (BODY MASS INDEX), NON-FAT AND OTHER HEALTH INDICATORS THROUGH MULTI-FREQUENCY BIOELECTRICAL IMPEDANCE ANALYSIS METHOD (MFBIA). ALLOW YOU TO LOOSE WEIGHT EFFECTIVELY ON A SCIENTIFIC BASIS. WHICH IS CONSIDERED AS AN EPOCH-MAKING RESULT OF THE HEALTH INDUSTRY. IF YOU ARE A HEALTH CONSULTANT ,IT CAN PROVIDE AN INDEPENDENT ANALYSIS OF HEALTH DATA FOR EACH TEST. APPLICABLE FOR FITNESS CENTERS , MEDICAL CENTERS, SENIOR CLUBS. SUPPORTING PROJECTS OF WEIGHT LOSS . DATA FUNCTION: ANALYSES THE SLIMMING EFFECT TO PROVIDE A THE SLIMMING TREATMENT, ON A SCIENTIFIC BASIS. THE REASONABLE WEIGHT CONTROL HELPS MAINTAIN THE BEST PHYSICAL STRENGTH AND DISTINGUISH BETWEEN MUSCLE TYPE, OVERWEIGHT AND/OR OBESITY. FINDS THE BEST CONTROL WEIGHT METHOD. SUGGESTS DIRECT ENERGY INTAKE AND DIETARY INTAKE OF NUTRIENTS IN CORRECT PROPORTIONS. GUIDING NUTRITION GUIDELINES AND RECOVERY MEASURES TO PROMOTE SYNTHESIS OF MUSCLES MASS. EVALUATION OF THE REHABILITATION TREATMENT EFFECT, GUIDING SCIENTIFIC BODY SLIMMING WITH SCIENTIFIC TRAINING, REHABILITATION, AND NUTRITION. DETECTS THE STATUS OF THE PHYSICAL AND HEALTH OF TEENAGERS, DEVELOPING FOR THEM A FEASIBLE EXERCISE PROGRAM. CLARIFY THE NUTRITION, AND OTHER FACTORS ON BODY COMPOSITION EFFECTS. SUGGEST INCIDENCE OF IMPORTANT PREVENTIVE MEASURES TO ATTEMPT TO REDUCE DIABETES. ADVANTAGES: WITH CE CERTIFICATE IT IS MULTI-FREQUENCY, INCLUDES 20KHz, 50KHz, AND 100KHz. IT CAN MEASURE YOUR WHOLE BODY. IT INCLUDES AN INBUILT MICRO THERMAL PRINTER AND HP COLOR PRINTER AT NO CHARGE THE ELECTRODE METHOD IS 8 POINT CONTACT ELECTRODE WHICH MAKES THE MEASUREMENT MORE ACCURATE. IT ANALYSIS A TOTAL OF 25 VALUE OF BODY COMPOSITIONS AND PROVIDES A HIGHLY ACCURATE WHOLE BODY ANALYSIS IN UNDER 10 SECONDS. THE COMPUTER HAS WIFI AND WIRELESS CONNECTION CAPABILITY SPECIFICATION: INPUT: 220V, 60Hz POWER: 53VA RATED CURRENT: <180μA SIZE: 390mm X 530mm x 1000mm QUANTITY: 1 Learn More -
TT-1036 ELECTROMECHANICAL UNIVERSAL TESTING MACHINETT-1036 ELECTROMECHANICAL UNIVERSAL TESTING MACHINE KEY SPECIFICATION: MAX. CAPACITY: 10N, 20N, 50N, 100N, 200N, 500N, 1KN, 2KN, 5KN,10KN,20KN DISPLAY: COMPUTER DISPLAY MODE FORCE RESOLUTION: 1/100,000 FORCE ACCURACY: ≤+/-0.5% STROKE RESOLUTION: 0.001mm STROKE RANGE: 1200mm TEST SPEED: 0.001-1000mm/MIN (OPTION), CAN SET BY COMPUTER, WITH UP & DOWN FAST ADJUSTMENT BUTTON OF GRIPS FORCE UNIT SWITCH: KGF, N, IBF, G, TON, MPA STOP MODE: OVERLOAD STOP, EMERGENCY STOP BUTTON, SPECIMEN DAMAGE AUTOMATIC STOP, UPPER & LOWER LIMIT SET AUTOMATIC STOP, AUTOMATIC RESET FUNCTION MACHINE DRIVE: SERVO MOTOR DRIVE, SYNCHRONOUS WHEEL AND PRECISION BALL SCREW DRIVE POWER: 400W DIMENSIONS: 76 X 60 X 175 (W X D X H) WEIGHT: 150KG POWER SUPPLY: 220V 50/60Hz 10A QUANTITY: 1 Learn More