Search results for: 'generator 3.8'
- Related search terms
- Generator po
- Generator power plant
- generator 60
- generator 60 k
- Generator Exhaust system.
-
TT-2287 ELECTRIC COMPLETE WORKING RIG 2000HP, YEAR 2016TT-2287 ELECTRIC COMPLETE WORKING RIG 2000HP, YEAR 2016 2000HP ELECTRIC COMPLETE WORKING RIG DRILLING RIG 2000HP YEAR 2016 TYPE: USED CONDITION: GOOD QUANTITY: 2 Learn More -
TT-8555 LIST OF HEAVY EQUIPMENTSLIST OF HEAVY EQUIPMENTS Learn More -
TT-7766 MITSUBISHI S16R PTA2S GENERATOR SET, 1880KW, YEAR 2003, 50HzTT-7766 MITSUBISHI S16R PTA2S GENERATOR SET, 1880KW, YEAR 2003, 50Hz QUANTITY: 8 Learn More -
TT-6504 HOWDEN 7MW TWIN CONDENSING STEAM TURBINE, YEAR 2018TT-6504 HOWDEN 7MW TWIN CONDENSING STEAM TURBINE, YEAR 2018 1. HOWDEN 7MW TWIN CONDENSING STEAM TURBINE 2. WITH A.C. GENERATOR 3. MODEL TWIN-CA 56 4. BRAND SIEMENS TURBOMACHINERY EQUIPMENT/TD POWER SYSTEMS SERIES SST-110 QUANTITY: 1 Learn More -
TT-4244 CATERPILLAR C-18 DIESEL INDUSTRIAL PRIME POWER MODULE WITH CATERPILLAR SR5 BRUSHLESS, SYNCHRONOUS AC GENERATOR SET IN 20’ ISO ENCLOSURE & FUEL TANK, 600KW, YEAR 2010, 60 HzTT-4244 CATERPILLAR C-18 DIESEL INDUSTRIAL PRIME POWER MODULE WITH CATERPILLAR SR5 BRUSHLESS, SYNCHRONOUS AC GENERATOR SET IN 20’ ISO ENCLOSURE & FUEL TANK, 600KW, YEAR 2010, 60 Hz CATERPILLAR C-18 DIESEL INDUSTRIAL 600KW PRIME POWER MODULE WITH 600KW CATERPILLAR SR5 BRUSHLESS, SYNCHRONOUS AC GENERATOR SET IN 20’ ISO ENCLOSURE & FUEL TANK GOOD USED YEAR 2010 QUANTITY: 1 Learn More -
YY-2961 25 MW GAS TURBINE GENERATOR (GT 10B2 - SGT 600)YY-2961 25 MW GAS TURBINE GENERATOR (GT 10B2 - SGT 600) BRIEF PLANT HISTORY: THE GT PACKAGE IS THE FAMOUS GT 10 B2 DLE PG WHICH WAS COMMISSIONED IN 2001 CONSISTING OF GAS TURBINE, GENERATOR AND ALL RELATED AUXILIARIES EQUIPMENT/SYSTEMS. IT IS IN EXCELLENT CONDITION AND AVAILABLE FOR IMMEDIATE SALE AND RELOCATION. QUANTITY: 3 Learn More -
TT-3703 HOWDEN TWIN CONDENSING STEAM TURBINE WITH A.C. GENERATOR, YEAR 2018TT-3703 HOWDEN TWIN CONDENSING STEAM TURBINE WITH A.C. GENERATOR, YEAR 2018 HOWDEN TWIN CONDENSING STEAM TURBINE WITH A.C. GENERATOR YEAR 2018 QUANTITY: 1 Learn More -
YY-2737 4MW WARTSILA DIESEL ENGINES, 6 SETSYY-2737 4MW WARTSILA DIESEL ENGINES, 6 SETS 4MW WARTSILA DIESEL ENGINES ENGINE MANUFACTURER: WARTSILA; ENGINE MODEL: 12V32E; RATED CAPACITY: 4.150KW; FUEL HFO; SPECIFIC FUEL CONSUMPTION 217.56 GMS/KWH SPECIFIC LUB OIL CONSUMPTION: 1.03 GMS/KWH CURRENT LUB; OIL BRAND: SHELL ARGINA X 40; LUB OIL SEPARATOR MAKE: ALFA LAVAL; FUEL OIL PURIFIER: ALFA LAVAL; WASTE HEAT RECOVERY BOILER: 3XTHERMAX 1.82 TPH (GENSET R1, R2, R3) COOLING TOWERS: PAHARPUR; COOLING WATER PUMPS: KIRLOSKAR, 250 M3/HR. Learn More -
P-5044 STA IMPIANTI ROASTER 5 KILOSP-5044 STA IMPIANTI ROASTER 5 KILOS
STA
MODEL: IMPIANTI
ROASTER
5 KILOS
STA IS A MANUFACTURING GROUP IN ITALY - THAT IS MADE UP OF SEASONED ENGINEERS FROM MOST OF THE BIG OLD ITALIAN ROASTING MACHINE MAKERS - SO THEIR SCOPE OF KNOWLEDGE AND HISTORY IS FANTASTIC. BASICALLY - THEIR CLAIM TO FAME IS HOT AIR INTRODUCED INTO THE TOP OF THE ROASTING CHAMBER . . . BEING PULLED THROUGH THE TURBULATING COFFEE AND EXITING THROUGH DRUM PERFORATIONS INTO THE BOTTOM. FIRST, THAT MAKES IT REALLY FRIENDLY TO BLENDING FORMULAS AND SECOND IT MAKES FOR SMALLER CHAFF - AS THE TURNING COFFEE BEATS IT UP A LITTLE AND THUS THE ROAST COMES OUT MORE CLEAN THAN THE OLD DAYS OF SOME SOLID DRUMS . . . SO IT IS DIFFERENT - WHICH DOES NOT MAKE IT BETTER - BUT IF YOU HAVE A BACKGROUND ON JABEZ BURNS . . THEN YOU WILL REALLY LOVE THIS PRODUCTION. BIG NATURALLY DEVELOPED BEANS - VERY EVEN ROAST. FOLLOWING IS THE MANUFACTURERS SPECS AND WE WILL BE GLAD TO DISCUSS MORE IN-DEPTH AS YOU HAVE QUESTIONS.ROASTING MACHINES LINE, PARTICULARLY SUITABLE FOR LITTLE PRODUCTION ACTIVITIES OF HIGH QUALITY ROASTED COFFEE, SUCH AS SHOPS, PASTRIES OR ARTISAN LABORATORIES. SMALL SIZE, TECHNOLOGICALLY ADVANCED, CONFIRM THEM ELVES AS IDEAL TOOL FOR THE PRODUCTION OF SELECTED COFFEES IN LITTLE QUANTITY. MADE WITH THE SAME REQUIREMENTS FOR RELIABILITY AND SECURITY FEATURES OF THE BIGGER AND MORE SOPHISTICATED INDUSTRIAL ROASTING MACHINES, ARE AVAILABLE WITH HEATING GENERATOR TYPE GAS BURNER (AVAILABLE ALSO BY ELECTRIC RESISTANCES) AND AUTOMATIC CONTROL SYSTEM WITH SEMIAUTOMATIC MANAGEMENT.
TECHNICAL DATA:
ROASTER CAPACITY: 5 KG. - MAX. 7 KG. CYCLE
ROASTING CYCLE: 9 MINUTES ÷ 20
RAW COFFEE PROCESSING PER HOUR: 20 KG. ÷ 30
INSTALLED ELECTRIC POWER: 0.9 KW | SINGLEPHASE 220 VOLTS 50 HZ
THERMAL POWER (NATURAL GAS OR LPG): 8000 KCAL/H
MAIN COMPONENTS:
HOPPER OF CHARGE IN STAINLESS STEEL
ROASTING DRUM
HEATING GENERATOR OF NEW GENERATION, PATENTED AND COMPLETE OF BURNER
RAMP VALVES FOR GAS SAFETY AND ELECTRIC DEVICE TO CHECK FLAMES RATIFIED AND COMPLETE OF ALARM SIGNAL
COOLING TANK IN STAINLESS STEEL
SAFETY PREVENTION SYSTEM ON THE COOLING TANK
SUPPORTING FRAME FOR THE OVER INDICATED COMPONENTS
ELECTRIC CONTROL BOARD MADE ACCORDING CE RULES, INTEGRATED, COMPLETE OF PLC + TOUCH SCREEN DEVICE FOR ROASTING MACHINE CONTROL AND MANAGEMENT.
INDEPENDENT FANS FOR THE ROASTING DRUM AND THE COOLING TANK
INDEPENDENT MOTORS FOR THE ROASTING DRUM AND THE COOLING TANK
CYCLONE FOR CHAFFS COLLECTING
DETAILS OF COMPONENTS:
HOPPER OF CHARGE IN STAINLESS STEEL WITH MANUAL IN-LET OF COFFEE WITH DOORUNLOADING SYSTEM.
ROASTING DRUM: MADE BY A FIXED ELEMENT WITH DOUBLE WALLS INSULATED FOR THERMAL PROTECTION AND SUPPORT OF THE ROTATING CYLINDER MOVING THE PRODUCT. SUCH CYLINDER, COMPLETELY MADE IN COMPOUND STEEL TO OVERCOME THE THERMAL CHANGES, IS DEVELOPED WITH A PERFORATED PLATE FOR THE CONTAINMENT AND SPECIAL BLENDERS ON THE RIGHT AND LEFT SIDE PLACED ON DIFFERENT LEVELS TO GET A PERFECT BLENDING OF COFFEE. AT THE END OF THE ROASTING CYCLE, THE PRODUCT UNLOADING IS ALLOWED BY A WIDE DOOR WITH MANUAL OPENING/CLOSING SYSTEM.
HEATING GAS GENERATOR OF NEW CONCEPT, PATENTED, COMPLETE OF BURNER, RAMP VALVES FOR GAS SAFETY AND ELECTRONIC EQUIPMENTS FOR FLAME CONTROL RATIFIED AND COMPLETE OF SIGNALLING ALARM.
COOLING TANK IN STAINLESS STEEL: WIDE SURFACE PERFORATED WITH TWO ARMS AND CROSSED FLOWS. UNLOADING MOUTH WITH HAND DRIVE.
SUPPORTING FRAME: MONO-BLOCK, PLATE PRESS-BENDED, STEEL MADE, SUPPORTING THE COMPONENTS PREVIOUSLY DESCRIBED.
SAFETY PROTECTION FOR COOLING TANK
ELECTRIC CONTROL BOARD FOR MACHINE MANAGEMENT ACCORDING CE RULES INTEGRATED. COMPLETE OF PLC + TOUCH SCREEN FOR ROASTING MACHINE CONTROL AND MANAGEMENT.
POSSIBLE RECORDING OF ROASTING PARAMETERS
CYCLONE FOR CHAFFS COLLECTING.
INDEPENDENT MOTORIZATION FOR ROASTING DRUM AND COOLING TANK
INDEPENDENT ELECTRIC-FAN FOR ROASTING DRUM AND ELECTRIC –FAN FOR COOLING TANK.QUANTITY: 1
Learn More -
K-8157 COAL FIRED POWER PLANT (2 X 50MW)K-8157 COAL FIRED POWER PLANT (2 X 50MW)
ENERGY BOILERS (CAE)
TURBINE SYSTEMS
STEAM TURBINES (TA) - DSL ARE 50 - 1
-CONDENSING TURBINE WITH TWO ADJUSTABLE OUTLETS, SUCH AS "ACTING" ON A SINGLE LINE OF TREES, DESIGNED TO DRIVE THE AC GENERATOR DIRECT-TYPE TH 60-2
-IS COMPOSED OF TWO BODIES: THE BODY OF HIGH PRESSURE (CIP) AND MEDIUM AND LOW PRESSURE BODY (CMP + CJP)
-HAS TWO ADJUSTABLE OUTLETS (PLUG SOCKETS AND PLUG HEATING) AND FIVE FIXED DOSES REGENERATIVE CIRCUIT FEEDSQUARES OF 600 CARS OVER T/H (WITH BUCKET WHEEL AND ARM LENGTH 12 M) - 4 PCS
-TIP HAMMER CRUSHERS CCA - 160 TO 2 PIECES
- RUBBER BANDS COAL TRANSPORTTHE MAIN EQUIPMENT IS ADDED TO ENSURE PROPER OPERATION FOLLOWING:
- SOLID FUEL STORAGE
- INSTALLATIONS AND INDUSTRIAL WATER SUPPLIES AND WASTEWATER DISCHARGE
- INSTALLATION OF EXHAUST HYDRAULIC SLAG
- WATER TREATMENT STATION
TO USE COAL, WEIGHT 88%, 12% NATURAL GASQUANTITY: 1
Learn More