Search results for: 'natural gas tur'
- Related search terms
- Gas
- Gas Generat
- Gas e
- Natural gas g
- turbine T
- TT-6412 SOLAR TITAN 130 GAS TURBINE GENERATOR SET, YEAR 2012, 50/60 HzTT-6412 SOLAR TITAN 130 GAS TURBINE GENERATOR SET, YEAR 2012, 50/60 Hz 1. SOLAR TITAN T-130 GAS TURBINE GENERATION PACKAGE 2. BRAND SOLAR 3. YEAR 2012 4. 60 Hz (CAN CONVERT TO 50 Hz) QUANTITY: 1 Learn More
- TT-4095 SIEMENS SGT 600 GAS TURBINE PLANT, 24.5 MW, 50 Hz, YEAR 2012 TO 2017TT-4095 SIEMENS SGT 600 GAS TURBINE PLANT, 24.5 MW, 50 Hz, YEAR 2012 TO 2017 MODEL: SGT 600 RATED CAPACITY: 24.5 MW SPEED: 1500 RPM GENERATOR OUTPUT: 11 KV FREQUENCY: 50 Hz AVAILABLE IN SINGLE CYCLE GT1 2012 GT2 2012 GT3 2107 GT4 2017 QUANTITY: 4 UNITS Learn More
- P-5044 STA IMPIANTI ROASTER 5 KILOS
P-5044 STA IMPIANTI ROASTER 5 KILOS
STA
MODEL: IMPIANTI
ROASTER
5 KILOS
STA IS A MANUFACTURING GROUP IN ITALY - THAT IS MADE UP OF SEASONED ENGINEERS FROM MOST OF THE BIG OLD ITALIAN ROASTING MACHINE MAKERS - SO THEIR SCOPE OF KNOWLEDGE AND HISTORY IS FANTASTIC. BASICALLY - THEIR CLAIM TO FAME IS HOT AIR INTRODUCED INTO THE TOP OF THE ROASTING CHAMBER . . . BEING PULLED THROUGH THE TURBULATING COFFEE AND EXITING THROUGH DRUM PERFORATIONS INTO THE BOTTOM. FIRST, THAT MAKES IT REALLY FRIENDLY TO BLENDING FORMULAS AND SECOND IT MAKES FOR SMALLER CHAFF - AS THE TURNING COFFEE BEATS IT UP A LITTLE AND THUS THE ROAST COMES OUT MORE CLEAN THAN THE OLD DAYS OF SOME SOLID DRUMS . . . SO IT IS DIFFERENT - WHICH DOES NOT MAKE IT BETTER - BUT IF YOU HAVE A BACKGROUND ON JABEZ BURNS . . THEN YOU WILL REALLY LOVE THIS PRODUCTION. BIG NATURALLY DEVELOPED BEANS - VERY EVEN ROAST. FOLLOWING IS THE MANUFACTURERS SPECS AND WE WILL BE GLAD TO DISCUSS MORE IN-DEPTH AS YOU HAVE QUESTIONS.ROASTING MACHINES LINE, PARTICULARLY SUITABLE FOR LITTLE PRODUCTION ACTIVITIES OF HIGH QUALITY ROASTED COFFEE, SUCH AS SHOPS, PASTRIES OR ARTISAN LABORATORIES. SMALL SIZE, TECHNOLOGICALLY ADVANCED, CONFIRM THEM ELVES AS IDEAL TOOL FOR THE PRODUCTION OF SELECTED COFFEES IN LITTLE QUANTITY. MADE WITH THE SAME REQUIREMENTS FOR RELIABILITY AND SECURITY FEATURES OF THE BIGGER AND MORE SOPHISTICATED INDUSTRIAL ROASTING MACHINES, ARE AVAILABLE WITH HEATING GENERATOR TYPE GAS BURNER (AVAILABLE ALSO BY ELECTRIC RESISTANCES) AND AUTOMATIC CONTROL SYSTEM WITH SEMIAUTOMATIC MANAGEMENT.
TECHNICAL DATA:
ROASTER CAPACITY: 5 KG. - MAX. 7 KG. CYCLE
ROASTING CYCLE: 9 MINUTES ÷ 20
RAW COFFEE PROCESSING PER HOUR: 20 KG. ÷ 30
INSTALLED ELECTRIC POWER: 0.9 KW | SINGLEPHASE 220 VOLTS 50 HZ
THERMAL POWER (NATURAL GAS OR LPG): 8000 KCAL/H
MAIN COMPONENTS:
HOPPER OF CHARGE IN STAINLESS STEEL
ROASTING DRUM
HEATING GENERATOR OF NEW GENERATION, PATENTED AND COMPLETE OF BURNER
RAMP VALVES FOR GAS SAFETY AND ELECTRIC DEVICE TO CHECK FLAMES RATIFIED AND COMPLETE OF ALARM SIGNAL
COOLING TANK IN STAINLESS STEEL
SAFETY PREVENTION SYSTEM ON THE COOLING TANK
SUPPORTING FRAME FOR THE OVER INDICATED COMPONENTS
ELECTRIC CONTROL BOARD MADE ACCORDING CE RULES, INTEGRATED, COMPLETE OF PLC + TOUCH SCREEN DEVICE FOR ROASTING MACHINE CONTROL AND MANAGEMENT.
INDEPENDENT FANS FOR THE ROASTING DRUM AND THE COOLING TANK
INDEPENDENT MOTORS FOR THE ROASTING DRUM AND THE COOLING TANK
CYCLONE FOR CHAFFS COLLECTING
DETAILS OF COMPONENTS:
HOPPER OF CHARGE IN STAINLESS STEEL WITH MANUAL IN-LET OF COFFEE WITH DOORUNLOADING SYSTEM.
ROASTING DRUM: MADE BY A FIXED ELEMENT WITH DOUBLE WALLS INSULATED FOR THERMAL PROTECTION AND SUPPORT OF THE ROTATING CYLINDER MOVING THE PRODUCT. SUCH CYLINDER, COMPLETELY MADE IN COMPOUND STEEL TO OVERCOME THE THERMAL CHANGES, IS DEVELOPED WITH A PERFORATED PLATE FOR THE CONTAINMENT AND SPECIAL BLENDERS ON THE RIGHT AND LEFT SIDE PLACED ON DIFFERENT LEVELS TO GET A PERFECT BLENDING OF COFFEE. AT THE END OF THE ROASTING CYCLE, THE PRODUCT UNLOADING IS ALLOWED BY A WIDE DOOR WITH MANUAL OPENING/CLOSING SYSTEM.
HEATING GAS GENERATOR OF NEW CONCEPT, PATENTED, COMPLETE OF BURNER, RAMP VALVES FOR GAS SAFETY AND ELECTRONIC EQUIPMENTS FOR FLAME CONTROL RATIFIED AND COMPLETE OF SIGNALLING ALARM.
COOLING TANK IN STAINLESS STEEL: WIDE SURFACE PERFORATED WITH TWO ARMS AND CROSSED FLOWS. UNLOADING MOUTH WITH HAND DRIVE.
SUPPORTING FRAME: MONO-BLOCK, PLATE PRESS-BENDED, STEEL MADE, SUPPORTING THE COMPONENTS PREVIOUSLY DESCRIBED.
SAFETY PROTECTION FOR COOLING TANK
ELECTRIC CONTROL BOARD FOR MACHINE MANAGEMENT ACCORDING CE RULES INTEGRATED. COMPLETE OF PLC + TOUCH SCREEN FOR ROASTING MACHINE CONTROL AND MANAGEMENT.
POSSIBLE RECORDING OF ROASTING PARAMETERS
CYCLONE FOR CHAFFS COLLECTING.
INDEPENDENT MOTORIZATION FOR ROASTING DRUM AND COOLING TANK
INDEPENDENT ELECTRIC-FAN FOR ROASTING DRUM AND ELECTRIC –FAN FOR COOLING TANK.QUANTITY: 1
Learn More - TT-5564 P&W FT8TWIN, 48MW, NATURAL GAS, YEAR 1994, 50HzTT-5564 P&W FT8TWIN, 48MW, NATURAL GAS, YEAR 1994, 50Hz P&W FT8TWIN YEAR: 1994 HOURS: 70000 TO 71000 QUANTITY: 2 Learn More
- J-5360 CUMMINS QSV81G NATURAL GAS GENERATOR, 1100 KW, YEAR 2001, 60 HzJ-5360 CUMMINS QSV81G NATURAL GAS GENERATOR, 1100 KW, YEAR 2001, 60 Hz MAKE: CUMMINS MODEL: QSV81G FUEL: NATURAL GAS 1100 KW 480/277 VOLTS YEAR: 2001 HOURS: 7393 12:1 COMPRESSION RATIO FRAME: HCI 73662 1300 KW / 1625 KVA CONTINUOUS RATED QUANTITY: 1 Learn More
- TT-2801 GENERAL ELECTRIC COGENERATION PLANT, 32350 KW, 13800 VOLTS, 60 Hz, YEAR 1995, NATURAL GASTT-2801 GENERAL ELECTRIC COGENERATION PLANT, 32350 KW, 13800 VOLTS, 60 Hz, YEAR 1995, NATURAL GAS QUANTITY: 1 Learn More
- TT-8236 GE LM 6000 PA COMPLETE POWER PLANT - CCPP, YEAR 1994, 50 Hz, HOURS 16003TT-8236 GE LM 6000 PA COMPLETE POWER PLANT - CCPP, YEAR 1994, 50 Hz, HOURS 16003 1. GE LM 6000 PA 2. FUEL: NATURAL GAS 3. HOURS 16003 4. COMPLETE POWER PLANT - CCPP 5. YEAR: 1994 6. VOLTAGE: 11000 7. FREQUENCY: 50 Hz QUANTITY: 3 SETS Learn More
- M-4010 10 MW BIOGAS TO STEAM CONGENERATION PLANT – 10 MEGAWATTS
REFERENCE NUMBER: M-4010
10 MW BIOGAS TO STEAM CONGENERATION PLANT – 10 MEGAWATTS
10 MW BIOGAS-FIRED COGENERATION PLANT
LATE MODEL, EXCELLENT CONDITION
INCLUDES BOILER, STEAM TURBINE, GENERATOR AND CONDENSER
CAPABLE OF CONVERTING METHANE, LANDFILL GAS, BIOGAS OR NATURAL GAS INTO ELECTRICITY
COMPLETE WITH ALL SUPPORT EQUIPMENT, INCLUDING PUMPS, WATER SYSTEMS, BLOWERS, ETC.
COMPLETE CONTROL ROOM AVAILABLE WITH OPERATIONAL CONTROL PANELS FEATURING CONTROLS BY PANALARM, FOXBORO, BENTLY NEVADA AND BASLER
STARTERS AND SWITCH GEAR BY SIEMENS
BOILER:
125,000 LBS/HR @ 725 PSI DELTAK FIRE TUBE STEAM BOILER
16,189 SQ. FT. HEATING SURFACE
STEAM TURBINE:
101,000 LBS/HR @ 600 PSI TERRY MULTI-STAGE CONDENSING STEAM TURBINE
INCLUDES WOODWARD GOVERNOR AND TACKE GEAR REDUCER
GENERATOR:
10,200 KW IDEAL ELECTRIC
1,800 RPM, 60 HZ
INCLUDES BRUSHLESS EXCITER
CONDENSER:
7,809 SQ. FT. GRAHAM SHELL AND TUBE HEAT EXCHANGER
CS AND ADMIRALTY BRASS CONSTRUCTION
88,100 LBS/HR EXHAUST
86 MM BTU/HR DUTY
Learn More - YY-3509 SOLAR MARS 100 GAS TURBINE ENGINEYY-3509 SOLAR MARS 100 GAS TURBINE ENGINE THIS UNIT HAS BEEN COMPLETELY OVERHAULED TO ZERO HOURS, AND IT HAS BEEN CERTIFIED IN A DESIGNATED TESTING FACILITY. QUANTITY: 1 Learn More
- TT-6694 GE LM6000PA GAS TURBINE - COMPLETE PACKAGE, 43MW, 50 Hz, YEAR 1994TT-6694 GE LM6000PA GAS TURBINE - COMPLETE PACKAGE, 43MW, 50 Hz, YEAR 1994 1. GE LM6000PA GAS TURBINE 2. MODEL LM 6000 PA 3. YEAR: 1994 4. HOURS: 16004 QUANTITY: 1 Learn More