Search results for: 'cast'
- Related search terms
- cast iron welding rod
- V-2003 DOUBLE SHAFT SHREDDER, TWO MOTORS, TOTAL 11KW, 1200mm (48 INCHES) WORKING WIDTH FOR DENSE PLASTIC WASTE SUCH AS INJECTION PLASTIC WASTE, ONE 5.5KW MOTOR FOR EACH OF THE TWO ROLLS (ONE ON EACH SIDE)V-2003 DOUBLE SHAFT SHREDDER, TWO MOTORS, TOTAL 11KW, 1200mm (48 INCHES) WORKING WIDTH FOR DENSE PLASTIC WASTE SUCH AS INJECTION PLASTIC WASTE, ONE 5.5KW MOTOR FOR EACH OF THE TWO ROLLS (ONE ON EACH SIDE) QUANTITY: 1 Learn More
- T-9483 FULLY AUTOMATIC FOUR EDGE-SEALING GAUZE PACKING MACHINET-9483 FULLY AUTOMATIC FOUR EDGE-SEALING GAUZE PACKING MACHINE TECHNICAL PARAMETERS: BAG SIZE: BASED ON CUSTOMER'S REQUEST SPEED: 120~180 BAGS/MIN PACKING MATERIAL: PAPER+PAPER, PAPER+PLASTIC IT CAN HOT SEALING PACKING MATERIAL, PACKAGE MATERIAL DIAMETER Φ ≤ 350mm, WIDTH IS BASED ON CUSTOMER'S REQUEST; VOLTAGE: 3P 380V 50Hz SERVO MOTOR 1.5 KW+SERVO MOTOR: 1 KW+STEPPING MOTOR 110 + STEPPING MOTOR 130 + VARIABLE FREQUENCY MOTOR 0.37KW, TOTALLY 5 MOTORS ARE 4KW USING 28 VOLT SERIES CIRCUIT HEAT, 2 HEATING PANELS, EACH PANEL HAVE 8 PCS HEATING TUBE, EACH TUBE 300W, TOTALLY 4.8KW MACHINE WEIGHT: 800 KG MACHINE SIZE: LENGTH 5000 X WIDTH 1300 X HEIGHT 1600mm WOODEN CARTON SIZE: LENGTH 2600 X WIDTH 1900 X HEIGHT 1800mm Learn More
- V-1886 WIRE FOR INNERSPRING MATTRESSES FROM EASTERN EUROPEV-1886 WIRE FOR INNERSPRING MATTRESSES FROM EASTERN EUROPE EN10270-1 Ф 1,35mm, Ф 2,38mm, Ф5mm (THESE ARE THE MOST COMMON) CTS WEIGHT LIMIT: 20TONNES/20” CONTAINER, AS YOU PREFER. Learn More
- YY-1136 ULTRAVIOLET STERILIZERYY-1136 ULTRAVIOLET STERILIZER MAINTENANCE OF UV STERILIZER: 1 CHECK REGULARLY TO ENSURE THE NORMAL OPERATION OF THE UV LAMP. 2. AFTER 9000 HOURS OR ONE YEAR OF CONTINUOUS USE, THE ULTRAVIOLET LAMP SHOULD BE REPLACED. WHEN REPLACING A NEW LAMP, FIRST UNPLUG THE POWER SOCKET OF THE LAMP AND TAKE OUT THE ULTRAVIOLET LAMP. PAY ATTENTION NOT TO TOUCH THE QUARTZ GLASS OF THE NEW LAMP WITH YOUR FINGERS, BECAUSE THE STAIN WILL AFFECT THE INTENSITY OF THE LIGHT, AND CAREFULLY PUT THE LAMP INTO THE CHAMBER OF THE STERILIZER. Learn More
- AA-1191 – SOURCE INFO MELT BLOWN CLOTH PRODUCTION LINE, VERTICAL TYPE (WIDTH: 600mm)AA-1191 – SOURCE INFO MELT BLOWN CLOTH PRODUCTION LINE, VERTICAL TYPE (WIDTH: 600mm) MACHINE PARTS: 1. VACUUM LOADER - 1 SET 2. HOPPER DRYER - 1 SET 3. SINGLE SCREW EXTRUDER - 1 SET 4. HYDRAULIC SCREEN CHANGER - 1 SET 5. METERING PUMP - 1 SET 6. T-DIE - 1 SET 7. BARREL TYPE FORMING MACHINE - 1 SET 8. ELECTROSTATIC ELECTRET DEVICE - 1 SET 9. SLIT AND COILER - 1 SET 10. HOT AIR SYSTEM - 1 SET Learn More
- A-2611 ULTRAVIOLET AGING TESTING CHAMBER BOX TYPEA-2611 ULTRAVIOLET AGING TESTING CHAMBER BOX TYPE FLUORESCENT UV LAMP IS IMPORTED FOR THIS ACCELERATED AGING TEST CHAMBER. CAN SIMULATE HARM BY SUNLIGHT, RAINWATER AND DEW. UV WEATHER RESISTANCE CHAMBER USE FLUORESCENT UV LAMP TO SIMULATES THE EFFECT OF SUNLIGHT, CONDENSATION MOISTURE IS USED TO SIMULATE DEW. THE TESTED MATERIAL IS PLACED IN A LOOP PROGRAM THAT ALTERNATES LIGHT AND MOISTURE AT A CERTAIN TEMPERATURE. THE MATERIAL WAS TESTED FOR ACCELERATED WEATHERABILITY. UV CHAMBER CAN RE-CREATE HAZARDS THAT OCCUR OUTDOORS FOR MONTHS OR YEARS.THE TYPES OF HAZARDS INCLUDE: DISCOLORATION, CHALKINESS, POWDER LIGHT, CRACKING, TURBIDITY, BUBBLES, BRITTLE, STRENGTH, DECAY, OXIDATION, ETC. THIS MACHINE INCLUDES SPRAY DEVICE. Learn More
- MELT BLOWN CLOTH PRODUCTION LINE 600mmREFERENCE NUMBER: A-2488 MELT BLOWN CLOTH PRODUCTION LINE 600mm SPECIFICATIONS: PLASTIC AUTOMATIC CHARGER • FEEDING CAPACITY: 200 KG / H • AIR PUMP POWER: 0.75 KW HOPPER PLASTIC DRYER • HOPPER CUBIC CAPACITY: 100 L • FEEDING CAPACITY: 50 KG • HEATING POWER: 3.7 KW • BLOWER POWER: 0.12 KW SJ55/30 SINGLE SCREW EXTRUDER • SCREW, BARREL: SCREW AND BARREL MATERIAL 38CRMOALA, NITRIDE • SCREW DIAMETER: 55 mm • SCREW L/D: 30:1 • MAIN MOTOR POWER: 15 KW SIEMENS STANDARD • MOTOR MAIN MOTOR SPEED ADJUSTMENT: 15 KW ABB INVERTER • BARREL HEATING: CASTING - HEATER WITH AIR COOLING • HEATING POWER: 2.8 KW X 4 ZONES • GEAR BOX: ZLYJ SERIES RIGID GEAR BOX • EXTRUSION CAPACITY: 15 TO 40 KG/H HYDRAULIC SCREEN CHANGER • MOTOR POWER: 1.1 KW • STRUCTURE: DOUBLE POSITION, PLATE TYPE • HEATERS: STAINLESS STEEL HEATING BAR METERING PUMP • MOTOR POWER: 2.2KW • CAPACITY: 30CC • SPEED CONTROL: • HEATERS: STAINLESS STEEL HEATING BAR T-DIE • STRUCTURE: T-DIE • MATERIAL OF MOULD: HIGH QUALITY ALLOYED STEEL, SURFACE CHROME PLATED • FLOW CHANNEL CHROME PLATED, POLISHED • SPECIFICATION OF PRODUCT: WIDTH 600 mm • AIR INCOME HOLES: 12 PCS, HIGH PRECISION TEMPERATURE CONTROL FORMING MACHINE • MOTOR POWER: 1.5 KW • SPEED CONTROL: INVERTER • SUCTION FAN: 5.5 KW ELECTROSTATIC ELECTRET DEVICE • INCLUDES ELECTROSTATIC GENERATOR, VOLTAGE REGULATOR, ELECTRET FRAME • APPLICATION: GENERATE ELECTROSTATIC CHARGE, INCREASES THE FILTERING EFFICIENCY • MOTOR POWER: 2.2 KW • BLADES: 4 PCS • HAULING SPEED CONTROL: ADOPTABB INVERTER COLIER • COILING SHAFT: 2 PCS • COMPACTION: BY PNEUMATIC CONTROL • COILING METHOD: BY SELF FRICTION SCREW AIR COMPRESSOR • MOTOR POWER: 37 KW • STRUCTURE: SCREW TYPE, LOW NOISY • PLC CONTROL AIR FILTER • CAPACITY: 7 M3/min • PRESSURE: 1.0 MPA • FILTRATION EFFICIENCY: 3 MICRON / 5 PPM AIR DRYER • CAPACITY: 6 NM3/min • PRESSURE: 1 MPA • POWER: 2 HP AIR TANK • VOLUME: 1000 L • PRESSURE: 1.05 MPA HOT AIR SYSTEM • HEATING POWER: 60 KW • HEATING TYPE: ELECTRIC HEATING • WITH HEAT INSULATION LAYER Learn More
- BACTERIAL FILTRATION UNITREFERENCE NUMBER: Y-2078 BACTERIAL FILTRATION UNIT NOT ONLY CONFORMS TO THE REQUIREMENTS OF MEDICAL SURGICAL MASK TECHNOLOGY IN THE TEST METHOD FOR FILTER EFFICIENCY (BFE) BACTERIA FIRST TEST INSTRUMENT, BUT ALSO CONFORMS TO THE AMERICAN SOCIETY FOR TESTING MATERIAL, THE REQUIREMENTS OF THE EUROPEAN EN14683 STANDARDS, INNOVATIVE IMPROVEMENTS WERE MADE ON THE BASIS OF THIS, WITH DOUBLE PNEUMATIC CONTRAST SAMPLING METHOD AT THE SAME TIME, IMPROVE THE PRECISION OF SAMPLING. IT IS SUITABLE FOR MEASURING AND TESTING DEPARTMENTS, SCIENCE RESEARCH INSTITUTE, MASK MANUFACTURERS AND OTHER RELEVANT DEPARTMENTS TO TEST THE PERFORMANCE OF MASK BACTERIAL FILTRATION EFFICIENCY. PRODUCT FEATURES: NEGATIVE PRESSURE TEST SYSTEM TO ENSURE THE SAFETY OF OPERATORS BUILT-IN PERISTALTIC PUMP IN NEGATIVE PRESSURE CABINET THE PERISTALTIC PUMP FLOW CAN BE SET THE FLOW RATE OF NIGHT SPRAY CAN BE SET AND THE ATOMIZATION EFFECT IS GOOD EMBEDDED HIGH SPEED INDUSTRIAL MICROCOMPUTER CONTROL 10.4 INCHES INDUSTRIAL HIGH BRIGHTNESS COLOR TOUCH SCREEN USB INTERFACE, SUPPORT U DISK DATA STORAGE CABINET BUILT-IN HIGH BRIGHTNESS LIGHTS BUILT-IN LEAKAGE PROTECTION SWITCHES TO PROTECT THE SAFETY OF OPERATORS THE INNER LAYER OF THE CABINET IS MADE OF STAINLESS STEEL, THE OUTER LAYER IS SPRAYED WITH PLASTIC AND COLD-ROLLED, AND THE INNER AND OUTER LAYERS ARE INSULATED AND FLAME RETARDANT. THE FRONT SWITCH TYPE GLASS DOOR IS CONVENIENT FOR THE EXPERIMENTER TO OBSERVE AND OPERATE. DETACHABLE BRACKET, ADJUSTABLE BRACKET HEIGHT SUPPORTING AND MOVING DUAL PURPOSE CASTERS SPECIFICATIONS: A ROUTE SAMPLING FLOW: 28.3L PER MINUTE B ROUTE SAMPLING FLOW: 20.3L PER MINUTE SPRAY FLOW: 8 TO 10L PER MINUTE PERISTALTIC PUMP FLOW: 0.006 TO 3.0 mL PER MINUTE FRONT PRESSURE OF A ROUTE SAMPLING FLOW METER: (-20 TO 0) kPa FRONT PRESSURE OF B ROUTE SAMPLING FLOW METER: (-20 TO 0) kPa FRONT PRESSURE OF SPRAY FLOW METER: (0 TO 300) kPa AMBIENT TEMPERATURE: (-40 TO 99) ℃ NEGATIVE PRESSURE OF THE AEROSOL CHAMBER: (-90 TO 120) kPa QUANTITY: 1 Learn More
- T-6545 MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTER
REFERENCE NUMBER: T-6545
MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTER
PRODUCT INTRODUCTION:
MASK BACTERIA FILTRATION EFFICIENCY KEY PERFORMANCE INDICATORS (BFE) DETECTOR TESTER NOT ONLY CONFORMS TO THE REQUIREMENTS OF MEDICAL SURGICAL MASKS TECHNOLOGY YY0469-2011 APPENDIX B IN THE TEST METHOD FOR FILTER EFFICIENCY (BFE) BACTERIA FIRST B. 1.1.1 TEST INSTRUMENT, BUT ALSO CONFORMS TO THE AMERICAN SOCIETY FOR TESTING MATERIAL ASTMF2100, ASTMF2101, THE REQUIREMENTS OF THE EUROPEAN EN14683 STANDARDS, INNOVATIVE IMPROVEMENTS WERE MADE ON THE BASIS OF THIS, WITH DOUBLE PNEUMATIC CONTRAST SAMPLING METHOD AT THE SAME TIME, IMPROVE THE PRECISION OF SAMPLING,IT IS SUITABLE FOR MEASURING AND TESTING DEPARTMENTS, SCIENTIFIC RESEARCH INSTITUTES, MASK MANUFACTURERS AND OTHER RELEVANT DEPARTMENTS TO TEST THE PERFORMANCE OF MASK BACTERIAL FILTRATION EFFICIENCY.
EXECUTION STANDARD:
Q/0212 ZRB003-2015 MEDICAL SURGICAL MASK
BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR RELATED INTELLECTUAL PROPERTY:
NO.: ZL200820224142.6 ELECTRIC FLOW CONTROL VALVE
NO.: ZL200820224143.0 GAS CAPACITY
NO.: ZL200920308391.8 AIR FILTRATIONMATERIAL FILTRATION EFFICIENCY DETECTOR
PRODUCT FEATURES:
NEGATIVE PRESSURE TEST SYSTEM TO ENSURE THE SAFETY OF OPERATORS;
BUILT -IN PERISTALTIC PUMP IN NEGATIVE PRESSURE CABINET, A, B TWO -WAY, SIX ANDERSEN; THE PERISTALTIC PUMP FLOW CAN BE SET;
THE FLOW RATE OF NIGHT SPRAY CAN BE SET AND THE ATOMIZATION EFFECT IS GOOD.
EMBEDDED HIGH SPEED INDUSTRIAL MICROCOMPUTER CONTROL; 10.4 INCHES INDUSTRIAL HIGH BRIGHTNESS COLOR TOUCH SCREEN;
USB INTERFACE, SUPPORT U DISK DATA STORAGE;
CABINET BUILT-IN HIGH BRIGHTNESS LIGHTS; BUILT-IN LEAKAGE PROTECTION SWITCH TO PROTECT THE SAFETY OF OPERATORS;
THE INNER LAYER OF THE CABINET IS MADE OF STAINLESS STEEL, THE OUTER LAYER IS SPRAYED WITH PLASTIC AND COLD-ROLLED, AND THE INNER AND OUTER LAYERS ARE INSULATED AND FLAME RETARDANT.
THE FRONT SWITCH TYPE GLASS DOOR IS CONVENIENT FOR THE EXPERIMENTER TO OBSERVE AND OPERATE.
DETACHABLE BRACKET, ADJUSTABLE BRACKET HEIGHT; SUPPORTING AND MOVING DUAL PURPOSE CASTERS.
QUANTITY: 1
Learn More - L-5536 OIL REFINERY, 105,000 BPD FOR LIGHT TO HEAVY CRUDE OILS
REFERENCE NUMBER: L-5536
OIL REFINERY, 105,000 BPD FOR LIGHT TO HEAVY CRUDE OILS
105,000 BPD
COMMISSIONED IN THE 1970s AND HAD A CAPACITY OF 155,000 BPD
NOW CONVERTED TO AN ATMOSPHERIC/VACUUM DISTILLATION REFINERY WITH FCC CAPABILITIES
DESIGNED TO PROCESS LIGHT TO HEAVY CRUDE OILS
CAN PROCESS CRUDE OIL WITH AN API RANGE OF 19 TO 44 (INCLUDING CASTILLA, HAMACA, EL SHARARA, CPC, AND SAHARA BLENDS)
QUANTITY: 1
Learn More