Search results for: 'projec'
- Related search terms
- PROJECT
- PROJECTILE
- projecti
- project+technical+engineer
- PROJECT GR
-
T-8347 CONTINUOUS PACKAGE WEIGHT CHECKING MACHINE, WIDTH 220mm, LENGTH 1300mm, SPEED 120 PIECE/MINT-8347 CONTINUOUS PACKAGE WEIGHT CHECKING MACHINE, WIDTH 220mm, LENGTH 1300mm, SPEED 120 PIECE/MIN CONTAINS THREE SECTIONS: FIRST SECTION HOLDS THE PRODUCT, SECOND IS WEIGHING SECTION AND LAST COLLECTION WEIGHING RANGE: 5G-1500G MIN ACCURACY: ±0.5G BELT WIDTH: 220mm BELT LENGTH: 1300mm BELT HEIGHT: 750 ± 50mm BELT HEIGHT AND BASKET CAN BE ADJUST TO YOUR REQUIREMENT MIN SCALE INTERVAL: 0.1G MAX SPEED: 120 PIECE/MIN INCLUDING PUTTER, PROTECTION COVER, COLLECTION BOX, MAIN SYSTEM CHECKWEIGHER SUBSTANTIATES THE EXTENSIVE KNOW-HOW THAT THE COMPANY HAS ACCUMULATED IN WEIGHING TECHNOLOGY OVER THE YEARS. BY INCLUDING A HIGH-PRECISION WEIGHT CHECKING FUNCTION IN THE PRODUCTION LINE, YOUR PRODUCT QUALITY CAN IMPROVE WITHOUT ANY DECLINE IN EFFICIENCY. THE SERIES PROVIDES A WHOLE RANGE OF FEATURES FOR HANDLING DIFFERENT PRODUCTS AND INCORPORATE NEW FUNCTIONS IN RESPONSE TO MODERN NECESSITIES. Learn More -
T-7018 LINE FOR PRODUCING 70 TO 150 DENIER FROM RECYCLED BOTTLEST-7018 LINE FOR PRODUCING 70 TO 150 DENIER FROM RECYCLED BOTTLES EXTRUDER Φ 160/25 PRODUCT TYPE PET-POY END/POSITION 12 ENDS POSITIONS 24 POSITIONS POSITION/SPINNING BEAM 2 POSITIONS/SPINNING BEAM POSITION DISTANCE (mm) 1500mm SPINNING PACK CYLINDER TYPE, BOTTOM MOUNTED SPINNERET DIAMETER (mm) Φ 90mm CROSS BLOWING AREA 1430mm X 1380mm GEAR PUMP SPECIFICATIONS (CC/REV) 12X3.0CC/REV GEAR PUMP QUANTITY/POSITION 1 OIL PUMP SPECIFICATION (CC/REV) 12X0.12CC/REV OIL PUMP QUANTITY/ POSITION 1 DOWTHERM BOILER/LINE 600L/65KW GUIDE ROLLER SYSTEM (DIAMETER X WIDTH) 160mm X 160mm MIGRATION JET AWA. JAPAN WINDER TWA1800-12ENDS Learn More -
T-6963 SULZER P7150 B390 N2 EP RD1, YEAR 2000, CAM DOBBYT-6963 SULZER P7150 B390 N2 EP RD1, YEAR 2000, CAM DOBBY QUANTITY: 12 Learn More -
ENTRY LEVEL MULTI NOZZLE ELECTROSPINNING UNITREFERENCE NUMBER: A-2479 ENTRY LEVEL MULTI NOZZLE ELECTROSPINNING UNIT THIS MACHINE IS DESIGNED TO ACCOMMODATE THE MAXIMUM COMPONENTS REQUIRED FOR AN OPTIMIZED AND VERSATILE ELECTROSPINNING PROCESS. IT’S AN IDEAL SOLUTION FOR LOWER-BUDGET PROJECTS WORKING ON SMALL-SCALE NANOFIBERS RESEARCH. IT HAS 3 HYBRID NOZZLES, SPINNING ON A ROTATING DRUM COLLECTOR OR PLATE COLLECTOR, THEREFORE ENABLING THE PRODUCTION OF BOTH WELL-ALIGNED AND RANDOMLY COLLECTED NANOFIBERS. THE HOMOGENEITY SYSTEM ALLOWS THE USER TO PRODUCE A UNIFORM AND HOMOGENEOUS NANOFIBERS MEMBRANES. SPECIFICATIONS: SPINNING-TYPE: SIDE BY SIDE SPINNING CHASSIS: ENCLOSED CHASSIS FOR SPINNING AREA FEEDING AREA MATERIAL: PE 1000 (HIGH DENSITY, CHEMICAL RESISTANT) COLLECTOR MATERIAL: 7000 SERIES ALUMINUM ALLOY, STAINLESS STEEL LED ILLUMINATION EXHAUST FAN TOTAL WEIGHT: APPROX.60 KGS DIMENSIONS: 740 X 645 X 770 mm HIGH VOLTAGE POWER SUPPLY VOLTAGE RANGE: 0 TO 30 KV VOLTAGE PRECISION: 0.1 KV MAX CURRENT: 0.170 MA HIGH PRECISION MICRO PUMP FLOW RATE: 0.01 TO 4464 ML/H (BD 60 ML SYRINGE) FLOW RATE PRECISION: 0.01 ML/H AVAILABLE SYRINGES STANDARD: ALL TYPES ARE AVAILABLE FEEDING AREA NUMBER OF NOZZLES: 3 NOZZLE NOZZLE MATERIAL: ELECTRICALLY CONDUCTIVE STAINLESS STEEL NOZZLE INNER DIAMETER: 0.8 mm COMPATIBLE WITH STANDARD SYRINGE NOZZLES MINIMUM REQUIRED SOLUTION FOR SINGLE NOZZLE FEEDING: 2 ML ROTATING COLLECTOR MATERIAL ALUMINUM DIMENSIONS OF THE DRUM: 100 X 220 mm FIBER DEPOSITION AREA: 314 X 220 mm DRUM ROTATING SPEED: 100 TO 500 RPM SURFACE SPEED (CM/S): 52.3 CM/S TO 261.6 CM/S STROKE OF COATING HOMOGENEITY SYSTEM: 30 TO 80 mm SPEED OF COATING HOMOGENEITY SYSTEM: 2 TO 20 mm /SEC STATIONARY PLATE COLLECTOR MATERIAL: STAINLESS STEEL DIMENSIONS OF STATIONARY PLATE 275 X 150 mm UNIQUE USER INTERFACE 4.3" TOUCH SCREEN CONTROL PANEL WITH WELL DESIGNED USER FRIENDLY INTERFACE FULLY ABLE TO CONTROL ALL PARAMETERS SAFETY FUNCTION EMERGENCY BUTTON HV WARNING LIGHT ELECTRICAL ISOLATED & GROUNDED CABINET OVER CURRENT PROTECTION TECHNICAL REQUIREMENTS POWER: 220 VOLTS AND 50/60 HZ @ MAX 25A GROUNDING: EXTERNAL GROUNDING LINE AREA: MIN. 1000 X 1000 mm WORKBENCH ABLE TO CARRY MINIMUM 150 KGS. Learn More -
HUMAN BODY ELEMENTS ANALYSIS MACHINEREFERENCE NUMBER: Y-2080 HUMAN BODY ELEMENTS ANALYSIS MACHINE HUMAN BODY ELEMENTS ANALYSIS EQUIPMENT, APPLIES THE ACCURATE MEASUREMENTS OF AVR MICROCOMPUTER CONTROLLER BASE ON NEW STATIC METHOD DXA, ANALYSIS HUMAN ELEMENTS, FAT WEIGHT BMI (BODY MASS INDEX), NON-FAT AND OTHER HEALTH INDICATORS THROUGH MULTI-FREQUENCY BIOELECTRICAL IMPEDANCE ANALYSIS METHOD (MFBIA). ALLOW YOU TO LOOSE WEIGHT EFFECTIVELY ON A SCIENTIFIC BASIS. WHICH IS CONSIDERED AS AN EPOCH-MAKING RESULT OF THE HEALTH INDUSTRY. IF YOU ARE A HEALTH CONSULTANT ,IT CAN PROVIDE AN INDEPENDENT ANALYSIS OF HEALTH DATA FOR EACH TEST. APPLICABLE FOR FITNESS CENTERS , MEDICAL CENTERS, SENIOR CLUBS. SUPPORTING PROJECTS OF WEIGHT LOSS . DATA FUNCTION: ANALYSES THE SLIMMING EFFECT TO PROVIDE A THE SLIMMING TREATMENT, ON A SCIENTIFIC BASIS. THE REASONABLE WEIGHT CONTROL HELPS MAINTAIN THE BEST PHYSICAL STRENGTH AND DISTINGUISH BETWEEN MUSCLE TYPE, OVERWEIGHT AND/OR OBESITY. FINDS THE BEST CONTROL WEIGHT METHOD. SUGGESTS DIRECT ENERGY INTAKE AND DIETARY INTAKE OF NUTRIENTS IN CORRECT PROPORTIONS. GUIDING NUTRITION GUIDELINES AND RECOVERY MEASURES TO PROMOTE SYNTHESIS OF MUSCLES MASS. EVALUATION OF THE REHABILITATION TREATMENT EFFECT, GUIDING SCIENTIFIC BODY SLIMMING WITH SCIENTIFIC TRAINING, REHABILITATION, AND NUTRITION. DETECTS THE STATUS OF THE PHYSICAL AND HEALTH OF TEENAGERS, DEVELOPING FOR THEM A FEASIBLE EXERCISE PROGRAM. CLARIFY THE NUTRITION, AND OTHER FACTORS ON BODY COMPOSITION EFFECTS. SUGGEST INCIDENCE OF IMPORTANT PREVENTIVE MEASURES TO ATTEMPT TO REDUCE DIABETES. ADVANTAGES: WITH CE CERTIFICATE IT IS MULTI-FREQUENCY, INCLUDES 20KHz, 50KHz, AND 100KHz. IT CAN MEASURE YOUR WHOLE BODY. IT INCLUDES AN INBUILT MICRO THERMAL PRINTER AND HP COLOR PRINTER AT NO CHARGE THE ELECTRODE METHOD IS 8 POINT CONTACT ELECTRODE WHICH MAKES THE MEASUREMENT MORE ACCURATE. IT ANALYSIS A TOTAL OF 25 VALUE OF BODY COMPOSITIONS AND PROVIDES A HIGHLY ACCURATE WHOLE BODY ANALYSIS IN UNDER 10 SECONDS. THE COMPUTER HAS WIFI AND WIRELESS CONNECTION CAPABILITY SPECIFICATION: INPUT: 220V, 60Hz POWER: 53VA RATED CURRENT: <180μA SIZE: 390mm X 530mm x 1000mm QUANTITY: 1 Learn More -
T-6543 MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENTREFERENCE NUMBER: T-6543
MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
SHANDONG INDEPENDENTLY RESEARCH AND DEVELOPMENT THIS COMPREHENSIVE TESTING MACHINE FOR SURGICAL MASK & PROTECTIVE CLOTHING, IT IS WIDELY USED IN A VARIETY OF MASK STRENGTH DETECTION PROJECTS.FEATURES:COMPLY WITH NATIONAL STANDARDS, MEDICAL STANDARDS TESTING REQUIREMENTS, AUTOMATIC SOFTWARE CONTROL SYSTEM, MEET THE REQUIREMENTS OF DATA STORAGE, PRINTING, COMPARISON. THE IMPORTED SERVO MOTOR IS EQUIPPED WITH PRECISION SCREW DRIVE SYSTEM TO ENSURE THE STABILITY OF TEST DATA.
TEST STANDARDS:
GB 19082-2009 TECHNICAL REQUIREMENTS FOR DISPOSABLE PROTECTIVE CLOTHING FOR MEDICAL USE (4.5 BREAKING STRENGTH -THE BREAKING STRENGTH OF MATERIALS IN KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 45N)
(4.6 ELONGATION AT BREAK -THE ELONGATION AT BREAK OF KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 15%)
SELF-PRIMING FILTER RESPIRATOR FOR RESPIRATORY PROTECTION ARTICLES5.6.2 BREATHING BONNET -BREATHING BONNET SHALL BE SUBJECT TO AXIAL TENSION"DISPOSABLE MASK: 10N FOR 10S" "REPLACEABLE MASK: 50N FOR 10S"
(5.9 HEADBAND -HEADBAND SHOULD BEAR THE TENSION "DISPOSABLE MASK: 10N, 10S" "REPLACEABLE HALF MASK: 50N FOR 10S" "FULL MASK: 150N FOR 10S")
5.10 JOINTS AND CONNECTING PARTS -JOINTS AND CONNECTING PARTS SHALL BE SUBJECT TO AXIAL TENSION
"REPLACEABLE HALF MASK: 50N FOR 10S" "FULL COVER 250N FOR 10S"
GB/T 32610-2016 TECHNICAL SPECIFICATION FOR DAILY PROTECTIVE MASKS
(6.9 BREAKING STRENGTH OF THE MASK BELT AND THE CONNECTION BETWEEN THE MASK BELT ANDTHE MASK BODY ≥ 20N)
(6.10 FASTNESS TO BREATHING BONNET: NO SLIPPAGE, BREAKAGE OR DEFORMATION SHALL OCCUR)
YY/T 0699-2013 DISPOSABLE SURGICAL MASK
(4.4 MASK BELT -THE BREAKING FORCE AT THE CONNECTION POINT BETWEEN EACH MASK BELT AND THE MASK BODY IS NOT LESS THAN 10N)
YY 0469-2011 SURGICAL MASK FOR MEDICAL USE (5.4.2 MASK BELT)
GB/T 3923.1-1997 DETERMINATION OF BREAKING STRENGTH AND ELONGATION AT BREAK OF FABRICS (STRIP METHOD)
DISPOSABLE RUBBER INSPECTION GLOVES (6.3 TENSILE PROPERTIES)
INSTRUMENT TECHNICAL PARAMETERS:
SPECIFICATION: 200N (STANDARD) 50N, 100N, 500N, 1000N (OPTIONAL)
ACCURACY: BETTER THAN 0.5RESOLUTION OF FORCE VALUE: 0.1N
DEFORMATION RESOLUTION: 0.001mm
TEST SPEED: 0.01mm/MIN ~ 2000mm/MIN (STEPLESS SPEED REGULATION)
WIDTH OF SAMPLE: 30mm (STANDARD FIXTURE) 50mm (OPTIONAL FIXTURE)
CLAMPING OF SAMPLES: MANUAL (PNEUMATIC CLAMPING CAN BE CHANGED)
STROKE: 700mm (STANDARD) 400mm, 1000mm (OPTIONAL)
QUANTITY: 1
Learn More -
T-6544 SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASKREFERENCE NUMBER: T-6544
SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
TECHNICAL INDICATORS:
1. THE PROTRUDING SAMPLE FIXING DEVICE CAN SIMULATE THE ACTUAL USE STATE OF THE MASK, SET ASIDE THE TEST TARGET AREA WITHOUT DESTROYING THE SAMPLE, AND DISTRIBUTE THE SYNTHETIC BLOOD IN THE TARGET AREA OF THE SAMPLE.
2. THE SPECIAL FIXED-PRESSURE INJECTION DEVICE CAN EJECT A CERTAIN VOLUME OF SYNTHETIC BLOOD IN A CONTROLLED TIME.
3. IT CAN FULLY SIMULATE THE INJECTION SPEED CORRESPONDING TO THE AVERAGE BLOOD PRESSURE OF HUMAN BODY OF 10.6KPA, 16KPA AND 21.3KPA.
4. A FIXED TARGET PLATE IS SET TO BLOCK THE HIGH-PRESSURE EDGE PART OF THE INJECTED LIQUID FLOW AND ONLY ALLOW THE STEADY FLOW PART TO BE SPRAYED ON THE SAMPLE, WHICH INCREASES THE ACCURACY AND REPEATABILITY OF THE LIQUID VELOCITY SPRAYED ON THE SAMPLE.
STANDARDS:
MEDICAL RESPIRATOR TECHNICAL REQUIREMENTS, 5.5 SYNTHETIC BLOOD PENETRATION BARRIER PERFORMANCE
YY/T 0691-2008 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK RESISTANCE TO SYNTHETIC BLOOD PENETRABILITY TEST METHOD (FIXED VOLUME, HORIZONTAL INJECTION)
YY 0469-2011 MEDICAL SURGICAL MASK TECHNOLOGY REQUIRES A BLOOD PENETRATION TEST DEVICE
ISO 22609:2004 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK TEST METHOD FOR RESISTANCE TO SYNTHETIC BLOOD PENETRATION (FIXED VOLUME, HORIZONTAL INJECTION)
ASTM F1862-07 STANDARD TEST METHOD FOR RESISTANCE OF MEDICAL FACE MASKS TO BLOT BY SYNTHETIC BLOOD (HORIZONTAL PROJECTION OF FIXED VOLUME AT A KNOW VELOCITY)
TECHNICAL PARAMETERS:
1. INJECTION DISTANCE: 300mm ~ 305mm ADJUSTABLE
2. NOZZLE DIAMETER: 0.84mm
3. INJECTION SPEED: 450CM/S, 550CM/S, 635CM/S
4. WEIGHT: 35KG
5. POWER SOURCE: AC220V 50HZ
QUANTITY: 1
Learn More -
T-2898 PP STAPLE FIBER PLANT, 6000 MTA, BRAND MOSTLY FLEISSNER , AUTEFA BALE PRESST-2898 PP STAPLE FIBER PLANT, 6000 MTA, BRAND MOSTLY FLEISSNER , AUTEFA BALE PRESS
20 TONS PER DAYPP STAPLE FIBER SYSTEM
Learn More
6000 MTA (LINE-1+LINE-2)
EXTRUTION & SPINNING PACKAGE -
R-7290 MIMAKI TS34 1800, YEAR 2014 –SUBLIMATION PRINTING – DIGITAL PRINTINGBRAND MIMAKI
Learn More
MODEL TS34 1800
YEAR 2014
STATUS AVAILABLE
MIMAKI TS34 1800 SUBLIMATION PRINTING MACHINE
PRINT SPEED UP TO 32 M 2 / H AT 540 X 720 DPI IN 4-COLOR MODE
PRINT SPEED OF 17.7 M 2 / H IN 6 COLOR MODE
PRINT SPEED OF 94 M 2 IN PROJECT PHASE / H AT 360 DPI IN 1 PASS MODE
CONTINUOUS INK SUPPLY SYSTEM (UISS)
TWO ALUMINUM LITER CARTRIDGES
THE MACHINE IS COMPLETE, RUNS SMOOTHLY
QUANTITY: 1 -
L-3886 CHICKEN FEED PRODUCTION LINEREFERENCE NUMBER: L-3886
Learn More
1) RECEIVING PROCESS
HEIGHT: 12 METERS
POWER: 1.5 KW
2) GRINDING AND MIXING PROCESS
LENGTH: 1.5 METERS
POWER: 1.5 KW
3) PELLETIZING AND BAGGING PROCESS
CAPACITY: 2 TO 3 TONS PER HOUR, PER UNIT
POWER: 37 KW
4) AUXILIARY PROCESS
POWE: 1.5 KW
5) ELECTRIC CONTROL SYSTEM
POWER: 3 PHASE, 380 VOLTS, 50 Hz