Search results for: 'Data color'
- YY-2227 USED KUSTER PAD BATCH DYEING PLANT, WORKING WIDTH 2000mmYY-2227 USED KUSTER PAD BATCH DYEING PLANT, WORKING WIDTH 2000mm USED CPB-DYEING PLANT ACCORDING TO TYPE 222.11 QUANTITY: 1 CONSISTING OF 2-BOWL DYEING PADDER MAKE: EDUARD KUSTERS TYPE: 222.11 YEAR: COMPL. REFURBISHED BEFORE DELIVERY TECHNICAL DATA: WORKING WIDTH: 2000mm; ROLLER FACE WIDTH: 2200mm; DRIVE SIDE: RIGHT; SERVICE SIDE: LEFT; PRESSURE: 50 KP/CM; TOTAL PRESSURE: 10 TO / 100 NM; SPEED: 60 M/MIN; POWER: 5.5KW; VOLTAGE: 3 X 400 V, 50Hz; AIR CONNECTION: 6 BARS LOCALLY; COLOR OF PAINT: ACCORDING TO AGREEMENT. Learn More
- T-8543 4 SIDE SEALING WET WIPES MACHINE, STABLE SPEED 60 TO 120 BAGS PER MINUTET-8543 4 SIDE SEALING WET WIPES MACHINE, STABLE SPEED 60 TO 120 BAGS PER MINUTE 4 SIDE SEALING WET WIPES MACHINE DRIVE MODE: AUTOMATIC STABLE SPEED: 60 TO 120 BAGS PER MINUTE MACHINE SIZE (L X W X H): 3000mm × 2500mm × 1800mm QUANTITY: 1 Learn More
- T-8404 AUTOMATIC MATTRESS HOTMELT GLUE LINET-8404 AUTOMATIC MATTRESS HOTMELT GLUE LINE CONTENT OF LINE HOT MELT SITATION UNIT - WITH HOT MELT UNIT (CORNER AND CENTER GLUING) TRANSPORTATION CONVEYOR WITH ANTISTATIC SILICON BELT (2 SETS) MATTRESS FLIPPING CONVEYOR (1 SET) AUTOMATIC PRESSING SYSTEM (1 SET) Learn More
- T-7932 GAUZE PRE-FOLDING AND X-RAY DETECTABLE THREAD ATTACHING MACHINET-7932 GAUZE PRE-FOLDING AND X-RAY DETECTABLE THREAD ATTACHING MACHINE MODEL: ZBJ234 MACHINE DIMENSION: 2600 X 1800 X 1200mm POWER SOURCE: 380V/50Hz/3PH AC POWER CONSUMPTION: 3.0KW Learn More
- T-7930 GAUZE SWAB FOLDING MACHINE, 100 X 100mm, UNFOLD EDGEST-7930 GAUZE SWAB FOLDING MACHINE, 100 X 100mm, UNFOLD EDGES POWER SUPPLY: 380V/50Hz/3PH. AC AND COMPRESSED AIR PRESSURE: ≥0.6MPA MACHINE SIZE: 2500(L) X 2200(W) X 1900(H)mm COMPRESS PER MINUTE BY EACH PRODUCTION LANE: 40 TO 45 PIECES PER MIN DEPENDS ON GAUZE QUALITY. THIS MODEL IS EQUIPPED 4 PRODUCTION LANES. Learn More
- T-7929 GAUZE SWAB FOLDING MACHINE, 75 X 75mm, UNFOLD EDGEST-7929 GAUZE SWAB FOLDING MACHINE, 75 X 75mm, UNFOLD EDGES POWER SUPPLY: 380V/50Hz/3PH. AC AND COMPRESSED AIR PRESSURE: ≥0.6MPA MACHINE SIZE: 2500(L) X 2000(W) X 1900(H)mm COMPRESS PER MINUTE BY EACH PRODUCTION LANE: 40 TO 45 PIECES PER MIN DEPENDS ON GAUZE QUALITY. THIS MODEL IS EQUIPPED 5 PRODUCTION LANES. Learn More
- T-7928 GAUZE SWAB FOLDING MACHINE, 50 X 50mm, UNFOLD EDGEST-7928 GAUZE SWAB FOLDING MACHINE, 50 X 50mm, UNFOLD EDGES POWER SUPPLY: 380V/50Hz/3PH. AC AND COMPRESSED AIR PRESSURE: ≥0.6MPA MACHINE SIZE: 2500 (L) X 1900 (W) X 1900 (H)mm COMPRESS PER MINUTE BY EACH PRODUCTION LANE: 40 TO 45 PIECES PER MIN DEPENDS ON GAUZE QUALITY. THIS MODEL IS EQUIPPED 6 PRODUCTION LANES. Learn More
- T-7927 GAUZE SWAB FOLDING MACHINE, 100 X 100mm, FOLDED EDGEST-7927 GAUZE SWAB FOLDING MACHINE, 100 X 100mm, FOLDED EDGES POWER SUPPLY: 380V/50Hz/3PH. AC AND COMPRESSED AIR PRESSURE: ≥0.6MPA MACHINE SIZE: 2500 (L) X 1900 (W) X 2200 (H)mm COMPRESS PER MINUTE BY EACH PRODUCTION LANE: 40 TO 45 PIECES PER MIN DEPENDS ON GAUZE QUALITY. Learn More
- BACTERIAL FILTRATION UNITREFERENCE NUMBER: Y-2078 BACTERIAL FILTRATION UNIT NOT ONLY CONFORMS TO THE REQUIREMENTS OF MEDICAL SURGICAL MASK TECHNOLOGY IN THE TEST METHOD FOR FILTER EFFICIENCY (BFE) BACTERIA FIRST TEST INSTRUMENT, BUT ALSO CONFORMS TO THE AMERICAN SOCIETY FOR TESTING MATERIAL, THE REQUIREMENTS OF THE EUROPEAN EN14683 STANDARDS, INNOVATIVE IMPROVEMENTS WERE MADE ON THE BASIS OF THIS, WITH DOUBLE PNEUMATIC CONTRAST SAMPLING METHOD AT THE SAME TIME, IMPROVE THE PRECISION OF SAMPLING. IT IS SUITABLE FOR MEASURING AND TESTING DEPARTMENTS, SCIENCE RESEARCH INSTITUTE, MASK MANUFACTURERS AND OTHER RELEVANT DEPARTMENTS TO TEST THE PERFORMANCE OF MASK BACTERIAL FILTRATION EFFICIENCY. PRODUCT FEATURES: NEGATIVE PRESSURE TEST SYSTEM TO ENSURE THE SAFETY OF OPERATORS BUILT-IN PERISTALTIC PUMP IN NEGATIVE PRESSURE CABINET THE PERISTALTIC PUMP FLOW CAN BE SET THE FLOW RATE OF NIGHT SPRAY CAN BE SET AND THE ATOMIZATION EFFECT IS GOOD EMBEDDED HIGH SPEED INDUSTRIAL MICROCOMPUTER CONTROL 10.4 INCHES INDUSTRIAL HIGH BRIGHTNESS COLOR TOUCH SCREEN USB INTERFACE, SUPPORT U DISK DATA STORAGE CABINET BUILT-IN HIGH BRIGHTNESS LIGHTS BUILT-IN LEAKAGE PROTECTION SWITCHES TO PROTECT THE SAFETY OF OPERATORS THE INNER LAYER OF THE CABINET IS MADE OF STAINLESS STEEL, THE OUTER LAYER IS SPRAYED WITH PLASTIC AND COLD-ROLLED, AND THE INNER AND OUTER LAYERS ARE INSULATED AND FLAME RETARDANT. THE FRONT SWITCH TYPE GLASS DOOR IS CONVENIENT FOR THE EXPERIMENTER TO OBSERVE AND OPERATE. DETACHABLE BRACKET, ADJUSTABLE BRACKET HEIGHT SUPPORTING AND MOVING DUAL PURPOSE CASTERS SPECIFICATIONS: A ROUTE SAMPLING FLOW: 28.3L PER MINUTE B ROUTE SAMPLING FLOW: 20.3L PER MINUTE SPRAY FLOW: 8 TO 10L PER MINUTE PERISTALTIC PUMP FLOW: 0.006 TO 3.0 mL PER MINUTE FRONT PRESSURE OF A ROUTE SAMPLING FLOW METER: (-20 TO 0) kPa FRONT PRESSURE OF B ROUTE SAMPLING FLOW METER: (-20 TO 0) kPa FRONT PRESSURE OF SPRAY FLOW METER: (0 TO 300) kPa AMBIENT TEMPERATURE: (-40 TO 99) ℃ NEGATIVE PRESSURE OF THE AEROSOL CHAMBER: (-90 TO 120) kPa QUANTITY: 1 Learn More
- T-6545 MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTER
REFERENCE NUMBER: T-6545
MASK BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR TESTER
PRODUCT INTRODUCTION:
MASK BACTERIA FILTRATION EFFICIENCY KEY PERFORMANCE INDICATORS (BFE) DETECTOR TESTER NOT ONLY CONFORMS TO THE REQUIREMENTS OF MEDICAL SURGICAL MASKS TECHNOLOGY YY0469-2011 APPENDIX B IN THE TEST METHOD FOR FILTER EFFICIENCY (BFE) BACTERIA FIRST B. 1.1.1 TEST INSTRUMENT, BUT ALSO CONFORMS TO THE AMERICAN SOCIETY FOR TESTING MATERIAL ASTMF2100, ASTMF2101, THE REQUIREMENTS OF THE EUROPEAN EN14683 STANDARDS, INNOVATIVE IMPROVEMENTS WERE MADE ON THE BASIS OF THIS, WITH DOUBLE PNEUMATIC CONTRAST SAMPLING METHOD AT THE SAME TIME, IMPROVE THE PRECISION OF SAMPLING,IT IS SUITABLE FOR MEASURING AND TESTING DEPARTMENTS, SCIENTIFIC RESEARCH INSTITUTES, MASK MANUFACTURERS AND OTHER RELEVANT DEPARTMENTS TO TEST THE PERFORMANCE OF MASK BACTERIAL FILTRATION EFFICIENCY.
EXECUTION STANDARD:
Q/0212 ZRB003-2015 MEDICAL SURGICAL MASK
BACTERIAL FILTRATION EFFICIENCY (BFE) DETECTOR RELATED INTELLECTUAL PROPERTY:
NO.: ZL200820224142.6 ELECTRIC FLOW CONTROL VALVE
NO.: ZL200820224143.0 GAS CAPACITY
NO.: ZL200920308391.8 AIR FILTRATIONMATERIAL FILTRATION EFFICIENCY DETECTOR
PRODUCT FEATURES:
NEGATIVE PRESSURE TEST SYSTEM TO ENSURE THE SAFETY OF OPERATORS;
BUILT -IN PERISTALTIC PUMP IN NEGATIVE PRESSURE CABINET, A, B TWO -WAY, SIX ANDERSEN; THE PERISTALTIC PUMP FLOW CAN BE SET;
THE FLOW RATE OF NIGHT SPRAY CAN BE SET AND THE ATOMIZATION EFFECT IS GOOD.
EMBEDDED HIGH SPEED INDUSTRIAL MICROCOMPUTER CONTROL; 10.4 INCHES INDUSTRIAL HIGH BRIGHTNESS COLOR TOUCH SCREEN;
USB INTERFACE, SUPPORT U DISK DATA STORAGE;
CABINET BUILT-IN HIGH BRIGHTNESS LIGHTS; BUILT-IN LEAKAGE PROTECTION SWITCH TO PROTECT THE SAFETY OF OPERATORS;
THE INNER LAYER OF THE CABINET IS MADE OF STAINLESS STEEL, THE OUTER LAYER IS SPRAYED WITH PLASTIC AND COLD-ROLLED, AND THE INNER AND OUTER LAYERS ARE INSULATED AND FLAME RETARDANT.
THE FRONT SWITCH TYPE GLASS DOOR IS CONVENIENT FOR THE EXPERIMENTER TO OBSERVE AND OPERATE.
DETACHABLE BRACKET, ADJUSTABLE BRACKET HEIGHT; SUPPORTING AND MOVING DUAL PURPOSE CASTERS.
QUANTITY: 1
Learn More