Search results for: 'Tech'
- Related search terms
- Technica
- techno contact
- technological investment
- Technical da
- technoplant
-
T-6543 MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENTREFERENCE NUMBER: T-6543
MEDICAL UNIVERSAL TENSILE TESTING EQUIPMENT
SHANDONG INDEPENDENTLY RESEARCH AND DEVELOPMENT THIS COMPREHENSIVE TESTING MACHINE FOR SURGICAL MASK & PROTECTIVE CLOTHING, IT IS WIDELY USED IN A VARIETY OF MASK STRENGTH DETECTION PROJECTS.FEATURES:COMPLY WITH NATIONAL STANDARDS, MEDICAL STANDARDS TESTING REQUIREMENTS, AUTOMATIC SOFTWARE CONTROL SYSTEM, MEET THE REQUIREMENTS OF DATA STORAGE, PRINTING, COMPARISON. THE IMPORTED SERVO MOTOR IS EQUIPPED WITH PRECISION SCREW DRIVE SYSTEM TO ENSURE THE STABILITY OF TEST DATA.
TEST STANDARDS:
GB 19082-2009 TECHNICAL REQUIREMENTS FOR DISPOSABLE PROTECTIVE CLOTHING FOR MEDICAL USE (4.5 BREAKING STRENGTH -THE BREAKING STRENGTH OF MATERIALS IN KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 45N)
(4.6 ELONGATION AT BREAK -THE ELONGATION AT BREAK OF KEY PARTS OF PROTECTIVE CLOTHING SHOULD NOT BE LESS THAN 15%)
SELF-PRIMING FILTER RESPIRATOR FOR RESPIRATORY PROTECTION ARTICLES5.6.2 BREATHING BONNET -BREATHING BONNET SHALL BE SUBJECT TO AXIAL TENSION"DISPOSABLE MASK: 10N FOR 10S" "REPLACEABLE MASK: 50N FOR 10S"
(5.9 HEADBAND -HEADBAND SHOULD BEAR THE TENSION "DISPOSABLE MASK: 10N, 10S" "REPLACEABLE HALF MASK: 50N FOR 10S" "FULL MASK: 150N FOR 10S")
5.10 JOINTS AND CONNECTING PARTS -JOINTS AND CONNECTING PARTS SHALL BE SUBJECT TO AXIAL TENSION
"REPLACEABLE HALF MASK: 50N FOR 10S" "FULL COVER 250N FOR 10S"
GB/T 32610-2016 TECHNICAL SPECIFICATION FOR DAILY PROTECTIVE MASKS
(6.9 BREAKING STRENGTH OF THE MASK BELT AND THE CONNECTION BETWEEN THE MASK BELT ANDTHE MASK BODY ≥ 20N)
(6.10 FASTNESS TO BREATHING BONNET: NO SLIPPAGE, BREAKAGE OR DEFORMATION SHALL OCCUR)
YY/T 0699-2013 DISPOSABLE SURGICAL MASK
(4.4 MASK BELT -THE BREAKING FORCE AT THE CONNECTION POINT BETWEEN EACH MASK BELT AND THE MASK BODY IS NOT LESS THAN 10N)
YY 0469-2011 SURGICAL MASK FOR MEDICAL USE (5.4.2 MASK BELT)
GB/T 3923.1-1997 DETERMINATION OF BREAKING STRENGTH AND ELONGATION AT BREAK OF FABRICS (STRIP METHOD)
DISPOSABLE RUBBER INSPECTION GLOVES (6.3 TENSILE PROPERTIES)
INSTRUMENT TECHNICAL PARAMETERS:
SPECIFICATION: 200N (STANDARD) 50N, 100N, 500N, 1000N (OPTIONAL)
ACCURACY: BETTER THAN 0.5RESOLUTION OF FORCE VALUE: 0.1N
DEFORMATION RESOLUTION: 0.001mm
TEST SPEED: 0.01mm/MIN ~ 2000mm/MIN (STEPLESS SPEED REGULATION)
WIDTH OF SAMPLE: 30mm (STANDARD FIXTURE) 50mm (OPTIONAL FIXTURE)
CLAMPING OF SAMPLES: MANUAL (PNEUMATIC CLAMPING CAN BE CHANGED)
STROKE: 700mm (STANDARD) 400mm, 1000mm (OPTIONAL)
QUANTITY: 1
Learn More -
T-6544 SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASKREFERENCE NUMBER: T-6544
SYNTHETIC BLOOD PENETRATION TESTER FOR SURGICAL MASK
TECHNICAL INDICATORS:
1. THE PROTRUDING SAMPLE FIXING DEVICE CAN SIMULATE THE ACTUAL USE STATE OF THE MASK, SET ASIDE THE TEST TARGET AREA WITHOUT DESTROYING THE SAMPLE, AND DISTRIBUTE THE SYNTHETIC BLOOD IN THE TARGET AREA OF THE SAMPLE.
2. THE SPECIAL FIXED-PRESSURE INJECTION DEVICE CAN EJECT A CERTAIN VOLUME OF SYNTHETIC BLOOD IN A CONTROLLED TIME.
3. IT CAN FULLY SIMULATE THE INJECTION SPEED CORRESPONDING TO THE AVERAGE BLOOD PRESSURE OF HUMAN BODY OF 10.6KPA, 16KPA AND 21.3KPA.
4. A FIXED TARGET PLATE IS SET TO BLOCK THE HIGH-PRESSURE EDGE PART OF THE INJECTED LIQUID FLOW AND ONLY ALLOW THE STEADY FLOW PART TO BE SPRAYED ON THE SAMPLE, WHICH INCREASES THE ACCURACY AND REPEATABILITY OF THE LIQUID VELOCITY SPRAYED ON THE SAMPLE.
STANDARDS:
MEDICAL RESPIRATOR TECHNICAL REQUIREMENTS, 5.5 SYNTHETIC BLOOD PENETRATION BARRIER PERFORMANCE
YY/T 0691-2008 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK RESISTANCE TO SYNTHETIC BLOOD PENETRABILITY TEST METHOD (FIXED VOLUME, HORIZONTAL INJECTION)
YY 0469-2011 MEDICAL SURGICAL MASK TECHNOLOGY REQUIRES A BLOOD PENETRATION TEST DEVICE
ISO 22609:2004 INFECTIOUS PATHOGEN PROTECTION EQUIPMENT MEDICAL MASK TEST METHOD FOR RESISTANCE TO SYNTHETIC BLOOD PENETRATION (FIXED VOLUME, HORIZONTAL INJECTION)
ASTM F1862-07 STANDARD TEST METHOD FOR RESISTANCE OF MEDICAL FACE MASKS TO BLOT BY SYNTHETIC BLOOD (HORIZONTAL PROJECTION OF FIXED VOLUME AT A KNOW VELOCITY)
TECHNICAL PARAMETERS:
1. INJECTION DISTANCE: 300mm ~ 305mm ADJUSTABLE
2. NOZZLE DIAMETER: 0.84mm
3. INJECTION SPEED: 450CM/S, 550CM/S, 635CM/S
4. WEIGHT: 35KG
5. POWER SOURCE: AC220V 50HZ
QUANTITY: 1
Learn More -
T-6548 FABRIC SURFACE WETTING TESTERREFERENCE NUMBER: T-6548
FABRIC SURFACE WETTING TESTER
INSTRUMENT TECHNICAL DESCRIPTION:
WATER TESTER IS TO INSTALL THE SAMPLE ON THE SAMPLE HOLDER AND MAKE AN ANGLE OF 45 ° WITH THE LEVEL. THE CENTER OF THE SAMPLE IS LOCATED AT A SPECIFIED DISTANCE BELOW THE NOZZLE. THE SAMPLE IS SPRAYED WITH A SPECIFIED VOLUME OF DISTILLED OR DEIONIZED WATER. BY COMPARING THE APPEARANCE OF THE SAMPLE WITH THE EVALUATION STANDARDS AND PICTURES TO DETERMINE ITS WATER-SOAKING GRADE, IT IS SUITABLE FOR MEASURING VARIOUS WATER-SOAKING TESTS ON THE SURFACE OF FABRICS WITH OR WITHOUT WATER RESISTANCE AND WATER REPELLENT FINISHING. THIS INSTRUMENT IS NOT SUITABLE FOR MEASURING THE WATER PERMEABILITY OF FABRICS, SO IT CANNOT BE USED TO PREDICT THE RAINPROOF PERMEABILITY OF FABRICS.
STANDARD:
GB19082-2009 TECHNICAL REQUIREMENTS FOR MEDICAL PRIMARY PROTECTIVE CLOTHINGGB / T4745 SURFACE MOISTURE RESISTANCE TEST
THE MAIN TECHNICAL INDICATORS OF THE INSTRUMENT:
GLASS FUNNEL: φ150mm
MEASURING CUP: 500ML
SAMPLE SUPPORT ANGLE: 45 °
INSTRUMENT CONFIGURATION:
1. ONE HOST
2. A GLASS FUNNEL
3. 500ML MEASURING CUP
QUANTITY: 1
Learn More -
R-3945 ROSSO SEWING & REVERSING LINE, YEAR 1997 TO 1998REFERENCE NUMBER: R-3945
ITEM 001
ROSSO 025 ES + ULTRATURN 3000 + PR250
YEAR: 1997
QUANTITY: 5ITEM 002
ROSSO 025 ES + ULTRATURN 3000 + PR250
YEAR: 1998
QUANTITY: 5ITEM 003
Learn More
ROSSO 025 ES + ULTRATURN 4000 + PR250
YEAR: 1998
QUANTITY: 10 -
R-7639 BELOIT TISSUE PAPER MACHINE , YEAR 1971REFERENCE NUMBER: R-7639
Learn More
YEAR : 1971
NOMINAL WIDTH: 2720mm
TRIMMED WIDTH 2680mm
DESIGN SPEED: 1600 M/MIN
PRODUCTION SPEED: UP TO 1550 M/MIN
GRAMMAGE: 14 TO 23 GSM
QUANTITY: 1 -
M-4008 POLYVINYL CHLORIDE (PVC) PLANT -150,000 METRIC TON PER YEARREFERENCE NUMBER: M-4008
POLYVINYL CHLORIDE (PVC) PLANT -150,000 METRIC TON PER YEAR
150,000 METRIC TON/YEAR
EXPANDABLE TO 180,000 METRIC TON/YEARSTART-UP: FEBRUARY 2001
SHUT DOWN: 2013
TECHNOLOGY: INEOS VINYL
THE PROCESS EMPLOYS "CLOSED LID" AND VCM STRIPPING TECHNOLOGY. THE REACTORS ARE DESIGNED TO REMAIN CLOSED IN BETWEEN BATCHES. UNREACTED VCM IS REMOVED WITH A STRIPPING COLUMN FOR RECYCLE.
PVC GRADES PRODUCED: K57, K66-R-G-F AND K70
RAW MATERIAL: VCM
MAJOR SYSTEMS AND EQUIPMENT FOR SALE:
(4) 120,000 LITER 304SS REACTORS (16 BAR)
(3) 316LSS COLUMNS (STRIPPER/SCRUBBER):
5.4 M DIA. X 11.4 M
3.2 M DIA. X 6.76 M
1.0 M DIA. X 19.4 M
22 METRIC TON/HR 316LSS CONTINUOUS FLUID BED DRYER SYSTEM (7,700 KG/HR)
(2) 200 HP 316LSS SOLID BOWL CENTRIFUGES
7,700 KW LOW PRESSURE BOILER
ROTEX SCREENERS
(4) 200 M³ ALUMINUM BULK STORAGE SILOS
(4) STATE-OF-THE-ART BAGGING LINES
COMPLETE DOCUMENTATION AND TECHNOLOGY AVAILABLE
Learn More -
F-1227 EPS BLOCK (6000×1200×600mm) PRODUCTIONREFERENCE NUMBER: F-1227 EPS BLOCK (6000×1200×600mm) PRODUCTION LINE (NEW) CONSIST OF: 1. EPS BATCH PRE-EXPANDER MODEL SJ1400 2. EPS AUTO AIR-COOLING BLOCK MOLDING MACHINE SB6000 3. EPS CUTTING MACHINE PSC6000 4. CNC CUTTING MACHINE SCS3000 5. AUTO SHAPE MOLDING MACHINE WITH VACUUM SZ-172 6. AUXILIARY EQUIPMENT QUANTITY AVAILABLE: 1 Learn More -
TT-7641 HAUSER QUILTING MACHINE, MODEL SNA, YEAR 1997, DURKOPP ADLER HEADTT-7641 HAUSER QUILTING MACHINE, MODEL SNA, YEAR 1997, DURKOPP ADLER HEAD MACHINE IS IN EXCELLENT TECHNICAL CONDITION QUANTITY: 1 Learn More -
TT-7695 KHS, RINK GMBH, KRONES AG, HOLSTEIN AND KAPPERT BOTTLE CAP FILLING LINE, YEAR 1991 TO 1995TT-7695 KHS, RINK GMBH, KRONES AG, HOLSTEIN AND KAPPERT BOTTLE CAP FILLING LINE, YEAR 1991 TO 1995 1. SECOND-HAND BOTTLE CAP FILLING LINE 2. BRAND: KHS, RINK GMBH, KRONES AG, HOLSTEIN AND KAPPERT, RECOP, VIDEOJET TECHNOLOGIES GMBH, LUDWIG BOHRER MASCHINENBAU GMBH 3. YEAR: 1991 TO 1995 4. CAPACITY: 50,000 BOTTLES/H 5. FORMATS: 0.33 L QUANTITY: 1 Learn More -
J-5331 MERT MAKINA M-1100 AUTOMATIC MATTRESS TAPE EDGE MACHINEJ-5331 MERT MAKINA M-1100 AUTOMATIC MATTRESS TAPE EDGE MACHINE -IN USED, LIKE NEW CONDITION (HAS RUN ONLY 20 MATTRESSES SINCE NEW) -FOR ALL SIZES (TWIN, FULL, QUEEN AND KING) -WITH AUTOMATIC MATTRESS FLIPPING AND TURNING -SPARE PARTS AND TECHNICAL SERVICE AVAILABLE FROM UNITED STATES QUANTITY: 1 Learn More