TT-3341 FOR DOUBLE DOFFER CARDING MACHINE, WORKING WIDTH 2500mm, YEAR 1998
CONDITION: USED
CATEGORY: CARDING MACHINES
SUBCATEGORY: TEXTILE MACHINERY
QUANTITY: 1 Learn More
T-7125 CARDING WILLOW, WORKING WIDTH 1500mm
TYPE OF FIBRES: ALPACA OR WOOL
WILLOW CARDING IS EQUIPPED WITH MECHANICAL AND ELECTRICAL DRIVES
CAPACITY: UP TO 1500 KGS/HOUR
WORKING WIDTH: 1500mm
QUANTITY: 1
Learn More
AJ-1112
YARN BALL WINDER MACHINE, 10 POSITIONS, NEW
MOTOR POWER: 1.5 KW
LARGE SIZE FORMED: 150mm x 150mm
DIMENSIONS: 2800mm x 800mm x 850mm
WEIGHT: 250 KGS
TYPE: 10 POSITIONS
QUANTITY: 1
Learn More
REFERENCE NUMBER: T-6933
MTU CONTAINERIZED DIESEL GENERATOR PLANT, 30.5 MW, YEAR 2017 AND 2018
MTU CONTAINERIZED DIESEL GENERATOR PLANT
30.5 MW
FIFTEEN (15) MTU16V4000G63 EXHAUST EMISSION OPTIMIZED DIESEL ENGINES COUPLED TO HIGH PERFORMANCE MECC ALTE ECO46 2L/4A ALTERNATORS, RATED AT 2546 KVA/2033 KW STANDBY POWER AND 2303 KVA / 1842 KW PRIME POWER, 1500 RPM, 400 VOLT, 50 Hz, YEAR OF MANUFACTURE: 2017 AND 2018, ONLY 150 TO 200 HOURS SINCE NEW. EACH GENERATOR IS HOUSED IN A 40 FT SOUND ATTENUATED CONTAINER. SKID MOUNTED RADIATOR DESIGNED FOR HIGH END TEMPERATURES, 40 FT HI CUBE CONTAINER WITH SWITCH GEAR ROOM AND CONTROL ROOM, EQUIPMENT INCLUDES: CONTROL PANELS, CONTROL SYSTEM, BREAKER PANELS, HEATERS, BATTERY CHARGER, SWITCH GEAR, TRANSFORMERS, FUEL TANK SYSTEM AND ETC. COMPLETE POWER PLANT IN MODULE DESIGN THAT CAN BE EASILY TRANSPORTED AND SET UP WITHIN DAYS TO GENERATOR STEADY STREAM OF ELECTRICAL POWER.
(15) ALL PURPOSE 40 FT SOUND ATTENUATED CONTAINERS WITH MTU16V4000G63 GENERATORS SETS.
RATING: 2546 KVA/2033 KW STANDBY POWER AND 2303 KVA / 1842 KW PRIME POWER
RADIATOR: SKID MOUNTED RADIATOR DESIGNED FOR HIGH END TEMPERATURES
RADIATOR DESIGN: TECNO GROUP TG00094AA 30M/S REDUCED AIRFLOW RADIATOR WITH ELECTRIC POWERED COOLING FAN
POWER BOX: CP6
MODEL: HMW‐2200‐T5 STD 2200KVA V400 / 50 Hz AS20
YEAR: 2017 AND 2018
HOURS: 150 TO 200 HOURS ONLY
VOLTAGE: 400V, 3PH, 50 Hz
ENGINE: MTU 16V4000G63 EXHAUST EMISSION OPTIMIZED ENGINE
ENGINE SPEED: 1500 RPM
STARTING SYSTEM: 24V ELECTRIC WITH OPTIMA YELLOW TOP BATTERIES AND BATTERY ISOLATOR
ENGINE GOVERNOR: ADEC
ALTERNATOR: MECC ALTE ECO46 2L/4A WITH MAUX EXCITATION, OIL PRIMER AND CENTRIFUGE FITTED AS CONFIRMED BY MTU, SET MOUNTED 4000A 4P MOTORIZED BREAKERS.
CONTROL PANEL: AS5 WITH FREE ISSUE COMAP IG‐NTC‐BB + INTELIVISION 5 COMPONENTS
AIR CIRCUIT BREAKER PANEL: 4 POLE: 4000A SCHNEIDER NW04 MOTORIZED H2 100KA BREAKING CAPACITY WITH MICROLOGIC 6.0A TRIP UNIT
HEATER: THERMOSTATICALLY CONTROLLED 9KW 400V 3 PHASE WATER JACKET HEATER WITH CIRCULATION PUMP BATTERY CHARGER: DEEPSEA DSE9470 10A INTELLIGENT MAINS BATTERY CHARGER INCLUDING: AUTOMATIC ELECTRIC PRE‐LUBE PUMP; SET MOUNTED 2000A NEUTRAL EARTHLING CONTACTOR WITH CT; FUEL RETURN COOLER; CENTRIFUGAL OIL FILTER (MTU) & PRIMARY WATER SEPARATOR FILTER.
INCLUDING: AUTOMATIC ELECTRIC PRE‐LUBE PUMP; SET MOUNTED 2000A NEUTRAL EARTHING CONTACTOR WITH CT; FUEL RETURN COOLER; CENTRIFUGAL OIL FILTER (MTU) & PRIMARY WATER SEPARATOR FILTER.
TRANSFORMERS
QUANTITY 4: 4MVA GBE OIL IMMERSED, FREE BREATHING STEP UP POWER TRANSFORMERS WITH OIL CONSERVATOR AND COPPER WINDINGS; 3 PHASE, 400‐33 KV; 50 Hz
QUANTITY 1: 2MVA GBE OIL IMMERSED, FREE BREATHING STEP UP POWER TRANSFORMERS WITH OIL CONSERVATOR AND COPPER WINDINGS; 3 PHASE, 400‐33 KV; 50 Hz
HV SWITCHGEAR CONTAINER
PURPOSE BUILT 40 FT HI CUBE CONTAINER WITH HEATING LIGHTING AND POWER INSTALLED. LINED WITH ROCK WOOL INSULATED PANELS INCLUDES HIGH LEVEL LOUVER WITH FAN AND LOW‐LEVEL LOUVER FOR NATURAL AIR FLOW. SPLIT INTO TWO SECTIONS/ROOMS WITH A CONTROL ROOM ON ONE SIDE AND SWITCH GEAR IN THE OTHER ROOM WITH 33 KV ABB RING SAFE SWITCHGEAR
CONTROL SYSTEM
REMOTE COMMUNICATION AND LOAD SUMMATION CONTROL PANEL (RCLSP)
1 X COMAP IM‐NTC BB BASE BOX CONTROLLER (SITE LOAD VALUE MONITORING & INTEGRATION) 1 X
COMAP IBNT INTERNET BRIDGE (BROADBAND INTERFACE)
1 X COMAP ILB+ LOCAL BRIDGE (LOCAL & PC REMOTE INTERFACE) 1 X 230/240V DC PSU
1 SET OF CONTROL MINIATURE CIRCUIT BREAKERS 1 SET
OF CAN BUS INTERFACE TERMINALS
BELDON 3106A CANBUS COMMUNICATION CABLING & CAT 5E ETHERNET COMMUNICATION CABLES COMAP
MAINSPRO G59‐3 PROTECTION RELAY (OVER/UNDER VOLTS, Hz & VECTOR SHIFT)
FUEL TANK SYSTEM
QUANTITY 4 X 40,000L FUEL TANKS; DOUBLE SKINNED; DD50 FUEL POLISHING SYSTEM; BUND ALARM; OVERFILL ALARM AND CONTENTS GAUGE WITH ADJUSTABLE VOLT FREE LEVEL ALARM.
QUANTITY 1 X 20,000L FUEL TANKS; DOUBLE SKINNED; DD50 FUEL POLISHING SYSTEM; BUND ALARM; OVERFILL ALARM AND CONTENTS GAUGE WITH ADJUSTABLE VOLT FREE LEVEL ALARM.
Learn More
REFERENCE NUMBER: A-2492
1000 L STABILITY CHAMBER
SPECIFICATIONS:
INNER CHAMBER SIZE: 1 X 1 X 1 mm
EXTERNAL DIMENSION: 1.2 X 1.97 X 2.17 mm
TEMPERATURE RANGE: 70 TO 180°C
HUMIDITY RANGE: 10% TO 98% RH, WHEN THE TEMPERATURE IS ABOVE 60°C, THE HUMIDITY CAN ACHIEVE 10% RH
TEMPERATURE & HUMIDITY FLUCTUATION: ±0.2℃, ±0.5% RH
INDICATION RESOLUTION: 0.01℃, 0.1% RH
TEMPERATURE & HUMIDITY UNIFORMITY: ±2℃, ±3% RH (TESTED WITH THE EMPTY CHAMBER, 30 MINUTES AFTER STABILIZATION)
HEAT UP AND COOL DOWN TIME: HEATING RATE: AVERAGE 3 ℃/MINUTES; COOLING RATE: AVERAGE 1 ℃/MINUTE (UNLOADED TEST)
MATERIAL: INNER CHAMBER: SUS#304 STAINLESS STEEL EXTERIOR STRUCTURE: STAINLESS STEEL PLATE + POWDER COATED
INSULATION: GLASS WOOL & PUF
PERSPIRATION RESISTANT: K STYLE TUBE
ACCESSORIES
• TEMPERATURE RESISTANT SILICONE GASKET: 1 PC
• CABLE PORT:1 PC; OD: 100 mm
• WINDOW LIGHT: 1 PC
• MULTIPANE VIEW WINDOW: 1 PC
• LOADING SHELVES: 2 PCS
REFRIGERATION & HEATING SYSTEM
• ORIGINAL IMPORTED HIGH EFFICIENCY COMPRESSOR
• AIR COOLING CONDENSER
• FIN – TUBE HEATER
• ORIGINAL IMPORTED SOLENOID VALVES
• INNER SPIRAL K – TYPE REFRIGERANT COPPER TUBE
• U – TYPE FINNED ELECTRO - THERMAL TUBE
• HEATING & COOLING SYSTEMS SEPARATED
• SINGLE STAGE REFRIGERATING SYSTEM
HUMIDIFYING & DEHUMIDIFYING SYSTEM
• ELECTRIC & BYTE TYPE HUMIDIFYING SYSTEM
• STAINLESS STEEL HUMIDIFYING BARREL WITH VIEW WINDOW FOR WATER LEVEL
• ADP DEHUMIDIFYING WAY
• OVER – TEMPERATURE AND OVERFLOW PROTECTION UNITS
• HUMIDIFYING & DEHUMIDIFYING SYSTEMS SEPARATED
CIRCLING & DRAIN SYSTEM
• CENTRIFUGAL FAN & IMPORTED MOTOR
• REVERSE UNIFLOW (AIR FLOW DIRECTION)
• FLOW – THROWS WIND
• DRAIN SYSTEM USES SWIRL TYPE OUTLET AND U – TRAP DEPOSITION UNIT
PROGRAMABLE MICRO COMPUTER LCD TOUCH CONTROLLER
• PROGRAMMABLE TOUCH CONTROLLER, USER - FRIENDLY, STABLE AND EASY USE
• PROGRAMS: 99 SEGMENTS PER PROGRAM, 120 PROGRAMS, 120 CYCLING PER PROGRAM
• PID & SSR CONTROL WAY, STABLE AND EASY USE
• HAVE SLOP CONTROL FUNCTION FOR HEATING & COOLING, LINKED PTNS CAN BE EXECUTED
• PID AUTOMATIC CALCULATION
• MICRO COMPUTER MULTI FUNCTION CONTROLLER, MAIN COMPONENTS ’DATA AUTOMATICALLY OUTPUT INCLUDING COMPRESSORS, SOLENOIDS, HEATING UNITS, ETC
• ERRORS OF MAIN COMPONENTS APPEAR ON THE LCD PANEL
• THE BRIGHTNESS OF THE LCD PANEL CAN BE ADJUSTED
• TIME SEQUENCE CONTROL INTERFACE RELAYS HAVE 3 GROUPS WHICH MANAGE THE OUTPUT OF OUTSIDE LOGIC UNITS INCLUDING SIGNAL, MECHANICAL AND POWER, ETC
• PROGRAMS AUTO – SAVE FUNCTION IF POWER CUT OFF SUDDENLY
• HAVE HOLD & ADV BUTTONS INPROGRAMS
• AUTOMATICALLY SET THE HIGH & LOW TEMPERATURE LIMITS AFTER PROGRAMS SET
• PASSWORD SET FUNCTION
• SD CARD SLOT, 2 GB SD CARD, RS232 OR ETHERNET (RJ45)
OPERATING ENVIRONMENT
• AMBIENT TEMPERATURE: +25℃ (2) RH ≤85%
PROTECTION
• ELECTRICITY LEAK PROTECTION
• LIGHTNING STRIKE PROTECTION, ZRN LIGHTNING ARRESTER INSIDE THE CONTROLLER
• SENSOR DATES TRANSFERRED INSIDE THE MICRO COMPUTER
• TEMP. SENSORS TO OPEN CIRCUIT OR SHORT CIRCUIT (+ - OVER)
• THE FIRST LEVEL OVER TEMPERATURE PROTECTION
• ERROR DETECTED UNITS
• THE SECOND LEVEL OVER TEMPERATURE PROTECTION TO ELECTRONIC OVER - TEMP PROTECTION UNIT
• THE THIRD LEVEL OVER - TEMPERATURE PROTECTION
• COMPRESSOR PROTECTION TO REFRIGERANTS PRESSURE PROTECTION & OVERLOAD PROTECTION.
• EXTENDED PROTECTION UNIT TO TWO SUPPLETIVE PORTS
• ERROR PROTECTION TO POWER CUT OFF, ERROR REPORTS SHOWN IN LCD PANEL AND AUDIBLE ALARM STARTS
• DYNAMIC HIGH AND LOW TEMPERATURE PROTECTION
• AMBIENT TEMPERATURE PROTECTION TO THE INNER CHAMBER AND SPECIMENS AUTOMATICALLY RETURN BACK TO AMBIENT TEMPERATURE AFTER THE OPERATION STOP SAFETY PROTECTION
• NON-FUSE PROTECTION SWITCH
• OVERHEAT ALARM PROTECTION
• COMPRESSOR OVERLOAD PROTECTION
• PHASE SEQUENCE PROTECTION
• MOTOR OVER TO CURRENT PROTECTION
Learn More