Search results for: 'stand'
- Related search terms
- standard height of office table
- standard insurance com
- standard voltage in usa
- stand up plate holder
- stand+up+plate+holder
- J-2968 PILLOW FILLING MACHINE WITH AUTOMATIC PRE-WEIGHING UNIT, FOR FEATHERJ-2968 PILLOW FILLING MACHINE WITH AUTOMATIC PRE-WEIGHING UNIT, FOR FEATHER SILO CAPACITY: 4.4m3 AUTOMATIC PRE-WEIGHING UNIT: 1, 300 LITER CAPACITY FILLING NOZZLES: 1 OUTPUT CAPACITY: UP TO 400 FILLINGS PER HOUR FILLING WEIGHT ACCURACY: UP TO 1 GRAM (UP TO 2% OF THE TOTAL WEIGHT) EXPECTED OUTPUT: 3 PILLOWS PER MINUTE WITH 2 LBS FEATHER PILLOWS VOLTAGE: 480 VOLTS (+/- 10%) PHASE: 3-PHASE + N + PE FREQUENCY: 60 Hz (+/- 2%) VOLTAGE AUXILIARY CIRCUITS: 24 VDC / 24 VAC INSTALLED POWER: 5.2 KW – 16 AMPS OPERATING PRESSURE: 6 BAR AIR CONSUMPTION: 50 LITERS PER MINUTE NOISE: < 70 Db QUANTITY: 1 Learn More
- J-2967 PILLOW FILLING MACHINE WITH AUTOMATIC PRE-WEIGHING UNIT FOR FEATHERJ-2967 PILLOW FILLING MACHINE WITH AUTOMATIC PRE-WEIGHING UNIT FOR FEATHER SILO VOLUME: 6.0m3 AUTOMATIC PRE-WEIGHING UNITS: 2 UNITS WITH 210 LITER CAPACITY FILLING NOZZLE: 1 OUTPUT CAPACITY: UP TO 700 FILLINGS PER HOUR FILLING WEIGHT ACCURACY: UP TO 1 GRAM (2% OF THE TOTAL WEIGHT) EXPECTED OUTPUT: 6 PILLOWS PER MINUTE WITH 2 LBS FEATHER PILLOWS VOLTAGE: 480 VOLTS (+/- 10%) PHASE: 3-PHASE + N + PE FREQUENCY: 60 Hz (+/- 2%) VOLTAGE AUXILIARY CIRCUITS: 24 VDC / 24 VAC INSTALLED POWER: 7.4 KW – 32 AMPS OPERATING PRESSURE: 6 BAR AIR CONSUMPTION: 50 LITERS PER MINUTE NOISE: < 70 Db Learn More
- How To Choose an N95 Respirator Mask For Coronavirus Prevention? All You Need to Know Before Buying Face Masks
How To Choose an N95 Respirator Mask For Coronavirus Prevention? All You Need to Know Before Buying Face Masks.
1. What’s an N95 mask?
An N95 respirator is a respiratory protective face mask, designed to help reduce the user’s exposure to airborne particles including very small particles (0.3 microns) and large droplets. N95 respirator face mask literally has a filtration efficiency of at least 95% against non-oily particles.
2. Differences between N95 mask and surgical mask?
Generally, the N95mask also includes an N95 surgical mask. So, here we will just compare a standard N95 particulate mask with a disposable surgical mask. Surgical masks are designed to be worn by healthcare professionals during surgery and nursing, to help prevent contamination of the surgical field or the patient by capturing liquid droplets that are expelled by the user.
An N95 particulate mask blocks at least 95 percent of very small (0.3 microns) test particles, and while a disposable surgical mask is fluid-resistant and protects the user against large particles (5 microns), droplets, sprays or splatter.
Different from a loose-fitting, disposable surgical mask, an N5 mask is tight-fitting to achieve a very close facial fit, which guarantees a minimal leakage around the edges of the mask when the user inhales. If properly fitted, the filtration capabilities of N95 respirators exceed those of disposable surgical face masks.Speaking of the N95 mask price and disposable surgical mask price, the N95 respirator mask is pricier than a surgical mask. In contrast, the N95 mask is reusable but the common surgical mask is disposable. Strictly speaking, N95 respirator masks should be worn for a maximum of eight hours while the disposable surgical mask is recommended to be replaced every four hours.
However, during the novel coronavirus outbreak, face masks are in short supply and everyone discards one or two face masks every day. A surgical mask could be used for a whole day in a good condition of no damage, no moisture, and no deformation. According to some researches, the N95 respirator mask used for two days still maintains a filtration efficiency of at least 95%, while the filtration efficiency of an N95 respirator used for three days reduced to 94.7%. So, if an N95 respirator is in good maintenance, you can wear it for at least 2 days, a week, maybe even a month.
3. Types of N95 mask
Generally, according to their intended use, the types of N95 masks include the standard N95 particulate respirators and N95 surgical respirator masks. Additionally, there are N95 masks with a breathing valve or not.
1) Differences between standard N95 particulate respirator and N95 surgical mask:
How to differentiate standard N95 particulate-filtering respirators and N95 surgical masks? The N95 surgical mask is literally a combination of N95 respirator and surgical mask, it is both certificated by NIOSH as an N95 respirator and also cleared by the FDA as a surgical mask. N95 surgical respirator masks are also referred to as medical respirators, healthcare respirators, or surgical N95s.
The significant difference between a standard N95 particulate respirator and an N95 surgical mask is that the N95 surgical mask is fluid-resistant while the standard N95 particulate respirator is not.
An N95 particulate respirator, also called N95 dust mask or N95 pollution mask, helps reduce very small particles inhaled by the user, and it is used for respiratory protection when the user might be exposed to particulate hazards. With a fluid resistance plus, an N95 surgical mask help reduce particles both inhaled and exhaled by the user, it is designed to be used during surgery and nursing tasks, whatever the user requires respiratory protection, expelled particulates or requires fluid resistance.
2) Differences between N95 masks with a breathing valve or not:
Many people question: Is an N95 mask with an exhalation valve better than the one without a valve?
In fact, the N95 respirators with an exhalation valve are not recommended to be used for coronavirus prevention, because the valve is a one-way vent that couldn’t keep your exhalation to yourself. It means that this valved N95 mask makes your breathing out easier and helps reduce heat build-up to avoid fogging up your glasses, however, it’s not that friendly to others.
Besides, the N95 mask with the valve is pricier than the one without a valve.4. What are the differences between N95, KN95, FFP2, and KF94?
When you search for the N95 respirators, there are many respirators such as KN95, FFP2, and KF94 that appeared in the same breath. What’s different between these respirators of different letters?
Actually, both the N95, KN95, FFP2 and KF94 respirators have almost the same filtration efficiency, it means that KN95, FFP2, and KF94 are as effective as the N95 respirator mask. The main difference between these respirators is that they are tested by different nations.
The N95 mask has a full name of NIOSH-certified N95 respirator, which means these respirators are tested of 95% filtration and certified by the U.S. National Institute of Occupational Safety and Health (NIOSH). The KN95 respirator is a particulate-filtering mask tested using the China criteria. The FFP2 is a filtering facepiece score of 94% filter capacity approved by Europe, and the KF94 is tested by Korea criteria.
To simply put, we could put these respirators into an equation as below:
N100 (99.97%) = FFP3 (99.95%) > N95 (95%) = KN95 (95%) = FFP2 (94%) = KF94 (94%) > KN90 (90%).
Learn More
Anti Virus Flu Mask Meets FFP2 N95 KN95 KF94 Guidance - TT-4735 SOLAR TURBINE TAURUS 60 – NEW, 5.67MW, YEAR 2019TT-4735 SOLAR TURBINE TAURUS 60 – NEW, 5.67MW, YEAR 2019 BRAND: SOLAR MODEL TAURUS 60 TYPE GAS TURBINES CONDITION NEW YEAR 2019 PACKAGE: BY SOLAR HOURS OF OPERATION: 0 FUEL CAPABILITY: NATURAL GAS/LIQUID COMBUSTION STANDARD: STANDARD BRAND KATO MODEL TAURUS 60 FREQUENCY 50Hz Learn More
- YY-3532 FOAM AIR PERMEABILITY TESTER, 2 OPTIONSYY-3532 FOAM AIR PERMEABILITY TESTER, 2 OPTIONS 2 OPTIONS FOR FOAM AIR PERMEABILITY TESTER THIS INSTRUMENT IS COMPLETELY BASED ON THE NATIONAL STANDARD TEST REQUIREMENTS, RESEARCH AND DEVELOPMENT OF CUSTOM DEVELOPMENT, A COMPLETE REPLACEMENT FOR THE STANDARD RECOMMENDED RXQ-1 TYPE OF FOAM AIR PERMEABILITY TESTER, THE INSTRUMENT HAS A HIGH DEGREE OF INTEGRATION, THE USE OF THE LATEST MEASUREMENT AND CONTROL TECHNOLOGY, TO ACHIEVE THE AUTOMATION OF THE TEST PROCESS, INTELLIGENT, AND IMPROVE THE TESTING ACCURACY. THROUGH THE 7-INCH TOUCH SCREEN, THE ENTIRE TESTING PROCESS OF ONE-KEY OPERATION, SIMPLE OPERATION, INTELLIGENT AND CONVENIENT, IS A MAJOR RESEARCH INSTITUTIONS, SCIENTIFIC RESEARCH INSTITUTES, QUALITY INSPECTION UNITS FOR THE DETERMINATION OF SPONGE AIR PERMEABILITY OF THE NECESSARY INSTRUMENTS. QUANTITY: 1 Learn More
- YY-3556 4 X 60 MW GE LM6000 PD 15PPM SPRINT GAS TURBINE POWER PLANTYY-3556 4 X 60 MW GE LM6000 PD 15PPM SPRINT GAS TURBINE POWER PLANT HISTORY: THE POWER PLANT CONSISTS OF X 50 MW GE LM6000 PD 15PPM SPRINT GAS TURBINE, ALL OF YEAR: 2011, 7000 HRS SINCE NEW EACH, 3000 RPM, 50 Hz, X 13 MW SIEMENS SST 300 STEAM TURBINE WITH 5000 HOURS EACH. PLANT WAS COMMISSIONED AND PUT INTO OPERATION IN 2012. QUNATITY: 1 Learn More
- YASHA LIST-1310-B FOR LUMMUS COTTON GIN EQUIPMENT LISTYASHA LIST-1310-B FOR LUMMUS COTTON GIN EQUIPMENT LIST American Plant & Equipment is dedicated to providing high-quality industrial machinery and equipment for various manufacturing and processing needs. Below is a detailed list of Lummus Cotton Gin Equipment, designed for efficient cotton processing. These machines are engineered to enhance productivity, reduce waste, and ensure high-quality output in the cotton ginning process. Each piece of equipment is described with its specific function and technical specifications, ensuring you have the right tools for optimal performance in your operations. Learn More
- TT-5551 CATERPILLAR MODEL XQ2000 SETS, YEAR 2000 TO 2004, 50/60 HzTT-5551 CATERPILLAR MODEL XQ2000 SETS, YEAR 2000 TO 2004, 50/60 Hz CATERPILLAR MODEL XQ2000 SETS YEAR MODELS 2000 TO 2004 5000 HOURS OPERATION SINCE NEW TO REBUILT ENGINES WITH 3K-TO-5K HOURS USED CATERPILLAR FEATURES EMISSIONS EPA AND CARB EMISSIONS CERTIFIED FOR NON-ROAD MOBILE APPLICATIONS. CATERPILLAR DIESEL GENERATOR SETS FACTORY DESIGNED, CERTIFIED PROTOTYPE TESTED WITH TORSIONAL ANALYSIS. PRODUCTION TESTED AND DELIVERED TO YOU IN A PACKAGE THAT IS READY TO BE CONNECTED TO YOUR FUEL AND POWER LINES. ELECTRIC POWER DESIGN PRO COMPUTER SIZING AVAILABLE. SUPPORTED 100% BY YOUR CATERPILLAR DEALER WITH WARRANTY ON PARTS AND LABOR. EXTENDED WARRANTY AVAILABLE IN SOME AREAS. THE GENERATOR SET WAS DESIGNED AND MANUFACTURED IN AN ISO 9001 COMPLIANT FACILITY. GENERATOR SET AND COMPONENTS MEET OR EXCEED THE FOLLOWING SPECIFICATIONS: AS1359, AS2789, ABGSM TM3, BS4999, DIN6271, DIN6280, EGSA101P, JEM1359, IEC 34/1, ISO3046/1, ISO8528, NEMA MG1-22. Learn More
- YASHA LIST-1310 FOR LUMMUS COTTON GIN EQUIPMENT LISTYASHA LIST-1310 FOR LUMMUS COTTON GIN EQUIPMENT LIST Learn More
- J-4941 AUTOMATED INDUSTRIAL MACHINERY AFM 2 DG WIRE BENDING MACHINEJ-4941 AUTOMATED INDUSTRIAL MACHINERY AFM 2 DG WIRE BENDING MACHINE MAKE: AIM (AUTOMATED INDUSTRIAL MACHINERY) MODEL: AFM 2 DG (ACCUFORM MODULAR 2DX) TILTING TABLE SINGLE STAGE BENDING HEAD OPTIONS: P8 F1 WE SERIAL NUMBER: C 3 F0701 2009 WIRING DIAGRAM: AFM 2D6 – P8WEF1 – 490 – V8 – 3 VOLTAGE: 460 VOLTS FREQUENCY: 50 / 60 Hz FULL LOAD: 40 KVA LARGEST LOAD: 9 KVA DIMENSIONS OF THE STAINLESS STEEL TABLE: WIDTH 15 FEET 1 INCH x LENGTH 10 FEET 5 inches LOWER STAINLESS STEEL TABLE EXPENSION DIMENSIONS: WIDTH 8 FEET x LENGTH 37.5 INCHES QUANTITY: 1 Learn More