J-4722 GE LM6000 PA GAS TURBINE, 42 MW, 50 Hz, DUAL FUEL, 10,500 VOLTS
J-4722 GE LM6000 PA GAS TURBINE, 42 MW, 50 Hz, DUAL FUEL, 10,500 VOLTS
MAKE: GE
MODEL: LM6000 PA
YEAR: 1993
42 MW
50 Hz
DUAL FUEL
10,500 VOLTS
CONDITION: USED, 12,000 HOURS
QUANTITY: 1
In stock
SKU
J-4722
REFERENCE NUMBER: J-4722
GE LM6000 PA GAS TURBINE, 42 MW, 50 Hz, DUAL FUEL, 10,500 VOLTS
MAKE: GE
MODEL: LM6000 PA
YEAR: 1993
42 MW
50 Hz
DUAL FUEL
10,500 VOLTS
CONDITION: USED, 12,000 HOURS
1- GAS TURBINE
MODEL: 7LM6000PA-NGGG03
MANUFACTURER: GE MADE IN USA
YEAR OF MANUFACTURER: 1993
SERIAL NUMBER: 185-1XX
RATED POWER: 42.3MW
HEAT EFFICIENCY: 40%
2- TURBOGENERATOR
MANUFACTURER: BRUSH MADE IN UK
MODEL: BDAX7-290ERJ
SERIAL NUMBER: 618XXA-2G
RATED OUTPUT: 59529 KVA
YEAR OF MANUFACTURER: 1993
VOLTAGE: 11 KV
FREQUENCY: 50 HZ
COOLANT: AIR
RATED SPEED: 3000 RPM
RATED POWER: 50.6MW
POWER FACTOR: 0.85
3- GEARBOX
MANUFACTURER: LUFKIN
MODEL: NFVQ24190
RATIO: 1.209:1
YEAR: 1993
MADE IN USA
4- CONTROL SYSTEM
MANUFACTURER: WOODWARD MADE IN USA
CONTROL SYSTEM: NETCON5000
CONTROL MODEL: NETCON5000
SOFTWARE VERSION: NETCONVERSION 2.09
5- MONITOR SYSTEM
MONITOR IS COMPOSED OF PRESSURE, TEMPERATURE, RUNNING-SPEED, VIBRATION SENSORS. MANUFACTURER OF VIBRATION: BENTLY
MADE IN USA
MODEL OF VIBRATION: BENTLY3300
YEAR: 1993
6- GENERATOR PROTECT
SYSTEM MANUFACTURER: GE
MODEL: DGP51AABA
YEAR: 1993
MADE IN USA
7- ROTOR GROUNDING
ALARM MANUFACTURE: BRUSH
MODEL: REFM
YEAR: 1993
MADE IN USA
8- GENERATOR EXCITATION CONTROL
SYSTEM MANUFACTURER: BRUSH
MODEL: AVR
YEAR: 1993
MADE IN USA
9- SILENCING BOX AND AIR INLET VENTILATION
SYSTEM AIR FLOW FOR TURBINE COMBUSTION: 230,000CFM
AIR FLOW FOR BOX VENTILATION: 85,000CFM
10- NATURAL GAS PRESSURE
MANUFACTURER: COOPER ENERGY SERVICES
TYPE: SUPERIOR
MADE IN USA
COMPRESSOR MODEL: MH62
SERIAL NUMBER: 04H10XX
STROKE: 6
RPM: 985
NET ROD LOAD RATING: 42000LBS
YEAR: 2004
11. LUBRICATION SYSTEM
12. HYDRAULIC STARTER
13. FUEL SYSTEM
14. CIRCULATING COOLING WATER SYSTEM
15. FIRE FIGHTING SYSTEM
16. UPGRADING-VOLTAGE SYSTEM
OPERATION HISTORY
YEAR OF STARTING GENERATOR: DEC-1995
YEAR OF GENERATORS DEC1995 TO DEC2003
SINGLE FUEL: ZERO # DIESEL OIL
FIRST STOPPING TIME: DEC2003
HOURS OF FIRST TIME PERIOD: 12,764.5 HOURS
STARTING TIMES: 1296 TIMES
OVERHAUL
OVERHAUL TIME PERIOD: JAN2004 TO APRIL2005
OVERHAUL MANUFACTURER: GE
OVERHAUL TITLE: EXCHANGE SINGLE FUEL SYSTEM INTO DUAL FUEL
DUAL FUEL: NATURAL GAS AND ZERO# DIESEL OIL
OVERHAUL CONTENT: REPLACED COMBUSTION CHAMBER DUAL NOZZLE-HPT AND LPT
CURRENT NOZZLE MODEL: L47713P05 (DRY OPERATION)
HOURS OF OPERATION AFTER OVERHAUL: 3235.5 HOURS
STARTING TIMES AFTER OVERHAUL: 644TIMES
YEAR OF OPERATION AFTER OVERHAUL: DEC2005 TO DEC2007
SECOND STOPPING-YEAR: DEC 2007
TOTAL HOURS OF TWICE TIME PERIOD OPERATION: 11,000HOURS
TOTAL TIMES OF TWICE TIME PERIOD STARTING: 1940 TIMES
1. OVERVIEW OF LM 6000 PA GAS TURBINE
LM 6000 PA GAS TURBINE IS A MODIFIED AERO ENGINE, WHICH IS MANUFACTURED BY GE COMPANY. ADHERING TO THE CHARACTERISTICS OF LIGHT GAS TURBINE, THE UNIT HAS THE CHARACTERISTICS OF FAST START AND STOP, HIGH SINGLE CYCLE EFFICIENCY, ENVIRONMENTAL PROTECTION, LIGHT WEIGHT AND HIGH INVESTMENT PER KILOWATT; THE UNIT IS COMPOSED OF FIVE STAGE LOW PRESSURE COMPRESSOR, 14 STAGE HIGH PRESSURE COMPRESSOR, COMBUSTION CHAMBER, TWO STAGE HIGH PRESSURE TURBINE AND FIVE STAGE LOW PRESSURE TURBINE; THE MAIN FUEL OF THE UNIT IS 0 × DIESEL OR NATURAL GAS. UNDER ISO CONDITION, THE SINGLE CYCLE POWER OF THE UNIT IS 42 MW, AND THE SINGLE CYCLE EFFICIENCY CAN REACH 39%.
2. COMPOSITION OF LM 6000 PA GAS TURBINE GENERATOR SET
A). SKID MOUNT OF GAS TURBINE GENERATOR. THE GAS TURBINE AND GENERATOR ARE INSTALLED ON THE SAME SKID MOUNT BODY AND ARE ENCLOSED IN THE BOX;
B) FUEL SYSTEM OF GAS TURBINE. EQUIPPED WITH LIQUID FUEL SYSTEM AND NATURAL GAS FUEL SYSTEM;
C) GENERATOR.
D) COMBUSTION AND VENTILATION AIR FILTER.
E) GEARBOX. TO REDUCE 3600 RPM OF THE GAS TURBINE OUTPUT TO 3000 RPM; 6).EXHAUST DEVICE.
F) AUXILIARY EQUIPMENT SKID MOUNT.
G) SKID MOUNTED OIL TANK OF GENERATOR / GEARBOX
H) SKID MOUNT OF LIQUID FUEL BOOSTER PUMP.
I) GAS FUEL BOOSTER MOUNT.
J) LIQUID FUEL FILTRATION AND HEATER SKID.
K) FIRE SKID MOUNT.
L) AIR COMPRESSOR SKID MOUNT.
M) AIR INTAKE COOLING AND ANTI-ICE DEVICE.
N) CONTROL ROOM BOX.
O) IT CONTAINS THE FUEL SYSTEM, CIRCULATING WATER SYSTEM, ALL OF THE EQUIPMENTS ARE IN A GOOD CONDITION.
3. OPERATION OF LM 6000 PA GAS TURBINE GENERATOR SET
THE UNIT WAS PUT INTO OPERATION ON DECEMBER 25TH, 1995. AT PRESENT, IT IS IN THE STATE OF SHUTDOWN. THE FOLLOWING IS THE MAIN OPERATION OF THE UNIT:
4. TECHNICAL TRANSFORMATION AND MAJOR MAINTENANCE. OIL TO GAS TRANSFORMATION.
IN 2004, IN ORDER TO REDUCE THE FUEL COST, THE UNIT WAS TRANSFORMED FROM OIL TO GAS. THE NEW DUAL FUEL COMBUSTION CHAMBER IS REPLACED, AND THE SOFTWARE AND HARDWARE OF THE GAS TURBINE CONTROL SYSTEM ARE UPDATED, SO THAT THE UNIT CAN USE EITHER LIQUID OR GAS FUEL ALONE OR BOTH FUELS FOR POWER GENERATION AT THE SAME TIME. IN ADDITION, A COMPLETE SET OF NATURAL GAS SUPPLY PIPELINE IS ADDED, A SEPARATE NATURAL GAS BOOSTER SKID IS EQUIPPED, AND THE NATURAL GAS PIPELINE SYSTEM INCLUDING NATURAL GAS METERING VALVE AND GAS PURGING DEVICE ARE EQUIPPED ON THE GAS TURBINE BODY. AFTER THE TRANSFORMATION, THE OPERATION EFFICIENCY OF THE WHOLE UNIT HAS BEEN IMPROVED, AND THE OPERATION CONDITION IS GOOD. ABOUT 3200 HOURS OF OPERATION AND POWER GENERATION AFTER THE TRANSFORMATION.
5. EQUIPMENT MAINTENANCE.
IN STRICT ACCORDANCE WITH GE'S SPECIFICATIONS, THE COMPANY HAS FORMULATED THE DAILY REGULAR INSPECTION AND MAINTENANCE PLAN OF GAS TURBINE, REGULARLY CARRIED OUT STRICT INSPECTION ON GAS TURBINE UNITS, AND CARRIED OUT HOLE PROBE INSPECTION ON GAS TURBINE IN STRICT ACCORDANCE WITH THE HOLE PROBE PLAN.
THE GAS TURBINE UNIT WAS TRANSPORTED TO USA REPAIR PLANT FOR OVERHAUL IN AUGUST 2004. NEW COMBUSTOR, NEW HIGH PRESSURE TURBINE AND NEW LOW PRESSURE TURBINE WHICH CAN USE NATURAL GAS AND DIESEL OIL WERE REPLACED. ALL SERVICE AND PRODUCT BULLETINS ISSUED BY GE UP TO THE END OF 2004 WERE IMPLEMENTED. THE UNIT EQUIPMENT WAS IN GOOD CONDITION BEFORE SHUTDOWN.
AT PRESENT, DUE TO THE SHUTDOWN OF THE UNIT, REGULAR UNIT BARRING IS IMPLEMENTED ONCE A WEEK, AND THE HIGH-PRESSURE ROTOR SPEED IS 2500 RPM, LOW PRESSURE ROTOR SPEED 200 RPM.
QUANTITY: 1