Ptmeg-pthf / polytetrahydrofuran (polyol): specified in due course.
Pure mdi / 4,4-diphenylmethane diisocyanate: specified in due course.
Solvent
Dmac / n,n,-dimethylacetamide: specified in due course.
Additives
Specified in due course.
Energies And Utilities At Site Border
Electrical Energy (Typical)
Voltage: 20 kv.
Fluctuation of voltage: ≤ ± 10 %.
Rated frequency: 50 hz.
Fluctuation of frequency: ≤ ± 3 %.
Electrical energy has to be made continuously available. If short skips, interruptions or longer breakdowns could happen at plant site, emergency power supply is necessary. Dependent on frequency and duration of power interruptions, the emergency power supply has to be designed either for critical items only or for the total plant.
Industrial Water
Pressure: 3.0 to 5.0 bar g.
Temperature: 29 °c.
Total hardness: 12 °dh.
Turbidity: 10 degree.
Fuel Oil
Type: methan.
Gross calorific value: approx. 38,100 kj/smc.
Energy And Utilities Inside Plant Border
The following energies and utilities have to be available uninterruptedly at constant conditions at battery limit.
Electrical Energy
Rated voltage: 3 x 380 ac, pe and loadable neutral line.
Fluctuation of voltage: max. 10 %.
Control voltage: 24 dc res. 230 ac.
Rated frequency: 50 hz.
Fluctuation of frequency: ± 1.5 % / short term ± 2.0 %.
Cooling Water
Pressure (at floor 0,0 m): 3.0 to 5.0 bar g.
Temperature (supply): 33 °c.
Temperature (return): 40.5 °c.
Total hardness: 12 °dh.
Turbidity: 10 degree.
To avoid corrosion, slime and deposit problems caused by micro biological growth, the cooling water should be treated with corrosion inhibitors and micro biocides.
Soft Water
Pressure (at floor 0,0 m): 3.0 to 5.0 bar g.
Temperature: 30 °c.
Chloride: 40 ppm.
Total hardness: 2 °dh.
Chilled Water
Pressure: 3.0 to 5.0 bar g.
Fluctuation of pressure: ± 0.5 bar.
Temperature (supply): 6 °c.
Temperature (return): 12 °c.
Ph at 20 °c: 6.5 to 7.5.
Total hardness: 6 °dh.
Conditions: free of solid of impurities.
Hot Water
Pressure: 3.0 to 5.0 bar g.
Temperature (supply): approx. 60 °c.
Compressed Air
Pressure: 2.0 to 3.0 bar g.
Humidity content (pressure dew point): + 4 °c.
Temperature: 15 to 30 °c (room temperature).
Conditions: oil free, free of any solid of impurities.
Instrument Air
Pressure: 7.0 to 7.5 bar g.
Fluctuation of pressure: ± 10 %.
Humidity content (dew point at atmospheric pressure): - 25 °c.
Temperature: 15 to 30 °c (room temperature).
Conditions: free of oil (technical standard) and any solid of impurities.
Nitrogen
Pressure gauge: 7.0 to 7.25 bar.
N²-content: 98 % vol.
Temperature: 15 to 30 °c (room temperature).
Humidity content (dew point at atmospheric pressure): -30 °c.