Discontinuous Foam Sheet Production Plant, with Vertical and Horizontal Cutting Machines, 1200mm Max Cutting Height
Scroll to zoom
100%
Description
Vertical Cutting Machine
Made for cutting PUR foam blocks.
Minimum cutting thickness is 5 mm.
Density of the foam should be less than 80 kg/m³.
Necessary thickness has to be adopted at the adjustable sidewall.
Blocks put on the cutting table have to have a flat surface to ensure the maximum support.
Maximum cutting height: 1170 mm.
Height adjustable side wall: 600 mm.
Cutting thickness min: 5.0 mm.
Total knife length: 8900 x 25 x 0.45 mm³.
Electrical power: 1.74 kW.
Total machine weight: 1500 kg.
Total dimensions of the machine: L 4550 x B 4800 x H 2550 mm³.
Dimension inner side cutting table: L 2200 x B 1585 mm².
Dimension outer side cutting table: L 2200 x B 2000 mm².
Horizontal Cutting Machine
Made for cutting PUR foam blocks Acoustiflex density 15 kg/m³ with rigidity up to 30 kPa into sheets.
Cutting thickness can be between 3 to 150 mm.
Necessary thickness of the sheet has to be input at the control unit and can then be cut semi or full automatic.
The cutting beam can be adjusted from -5° to +5° to ensure a smooth cutting.
The blocks put on the cutting table have to have a flat surface to ensure the maximum adherence.
Maximum block dimensions: width 2150 x length 5000 x height 1200 mm³.
Maximum cutting height: 1200 mm.
Cutting speed: 0 to 25 m/min.
Cutting thickness: 3.0 to 150 mm.
Total electrical power: 12.00 kW.
Total machine weight: 2200 kg.
Offer Includes
1 set of grinding wheels.
Manual in English.
Warranty: a guarantee covers all parts of the plant for a period of six months from the date of dispatch of the plant to the client.
Regulations and Absorption
Inside the factory building where the production line will be installed must have a winter room temperature between 18 °C and 30 °C.
Flat bottom at the area where the cutting machines are placed.
For its perfect running, the production line voltage needs three-phase electric power + neutral + earth 380 VAC; 50 Hz (other voltage/Hz on request).
Important
The voltage rating must not be subject to a +5% voltage drop in respect of the nominal value and the voltage unbalance among the phases does not have to exceed 3%.
Be advised that a voltage unbalance of 3.5% causes a temperature increase of motors of about 25%.
Therefore it is of the utmost importance that such unbalance is kept under strict control and to the minimum.
Request a Quote
✓
Request sent
Thank you, our team will reply to you shortly.
Direct access to our team
Email American Plant & Equipment
Tell us what you want to buy, source, finance, or sell. A machinery specialist will follow up with you.
✓
Thank you. Your request is with the American Plant and Equipment team.
A machinery specialist will follow up with you.
Machinery updates
Subscribe to our email list
Tell us which industries you follow and we will send you the machines that match.
✓
You are on the list.
We will email you when machines that match your interests come in. Unsubscribe from any message.