Description Overview Natural gas fired combined heat and power (CHP) plant With 2 x Wartsila 3.5 MW gas generators Delivered in year 1998 Total operating hours approximately 30,000 per engine Generator Drivers Wartsila 16 cylinder / 1000 rpm gas engines, type W16V25SG Electrical Output Complete plant electrical output 7.1 MW at 6.4 kV / 50 Hz from alternators Heat Recovery Heat recovery for 80 °C water Steam boiler 10 t/h at 12 bar (supplementary fired) Condition Equipment is still installed and in a fair condition