Siemens, SST 400, 2013, 24.5MW Condensing Steam Turbine-Generator Package, 50 Hz

Description

  1. Item 001: Siemens Condensing Steam Turbine-Generator Set
    1. Power rating: 24.5 MW
    2. Year of manufacture: 2013
    3. Condition: New, unused
    4. Operating hours: 0
    5. Status: Installed
  2. Turbine
    1. Brand: Siemens
    2. Model: SST 400
    3. Type: Condensing
    4. Economical rating: 20,580 kWe
    5. Maximum continuous rating: 24,560 kWe
    6. Rated speed: 4,460 rpm
    7. Inlet flow rated / maximum: 61,000 kg/h / 93,260 kg/h
    8. Inlet pressure rated / maximum: 46 bar abs. / 48.3 bar abs.
    9. Inlet temperature rated / maximum continuous rating: 400 °C / 408 °C
    10. Secondary admission rated pressure: 4.49 bar abs.
    11. Secondary admission rated flow: 10,256 kg/h
    12. Secondary admission rated temperature: 260 °C
    13. Exhaust pressure rated: 0.071 bar abs.
    14. Exhaust temperature rated: 39 °C
  3. Performance
    1. Zero secondary admission: inlet flow 93,260 kg/h, inlet pressure 46 bar abs., inlet temperature 400 °C, exhaust pressure 0.071 bar abs., power 23,900 kWe
    2. Full secondary admission: inlet flow 93,260 kg/h, inlet pressure 46 bar abs., inlet temperature 400 °C, exhaust pressure 0.071 bar abs., power 24,560 kWe
  4. Gearbox
    1. Brand: Lufkin
    2. Input speed: 4,500 rpm
    3. Output speed: 1,500 rpm
  5. Alternator
    1. Brand: Brush
    2. Rated capacity: 30,900 kVA
    3. Power factor: 0.8
    4. Speed: 1,500 rpm
    5. Frequency: 50 Hz
    6. Voltage: 11,000 V
  6. Condenser
    1. Brand: Tema (India)
    2. Type: Water-cooled (surface)
  7. Item 002: Rentech 73 t/h Natural Gas / Syngas Fuelled Boiler Plant
    1. Year of manufacture: 2014
    2. Condition: Unused
    3. Operating hours: 0 (never operated)
    4. Status: Installed
    5. Fuel: Syngas / natural gas
    6. Brand: Rentech
    7. Steam capacity: 73 t/h
    8. Steam temperature: 400 °C
    9. Steam pressure: 45 bar
    10. Equipped with selective catalytic reduction (SCR) where aqueous ammonia is injected for NOx reduction
    11. Flue gases exiting the stack are continually monitored by way of the continuous emissions monitoring system (CEMS)
    12. The CEMS monitors compliance with environmental regulations
    13. Already dismantled the package and can make it available for delivery in 2 weeks