Outer box material: stainless steel (1.2 mm thick)
Sterilization temperature: 50°C ±3°C
Working pressure: -75KP to 50 KPA
Maximum pressure resistance: -80KPA
Sterilization humidity: 45%-75%
Selected gas: mixed gas (80% EO, 20% carbon dioxide)
Ethylene oxide sterilization concentration: 0.8 to 1.2 g/L
Sterilization time: 0-99 hour adjustable
Vacuum speed: 25 minutes to -50KPA
Air replacement: automatic ventilation, air exchange frequency and interval can be set freely
Control And Display
Automatic control system: one-click start to end; the whole process is automatically completed with print record
Display status: displays temperature, humidity, pressure, sterilization time, residual gas treatment time, number of times
Printer: the whole process of sterilization information record printing, in order to verify the check
Sensors And Systems
Humidity sensor: the built-in humidity sensor automatically detects the humidity in the cavity to ensure that the humidity in the cavity is not lower than 45% RH
Pressure sensor: the inner pressure sensor automatically detects the pressure inside the cavity to ensure the accuracy and efficiency of the pressure
Temperature sensor: the built-in temperature sensor automatically detects the cavity temperature to ensure that the cavity temperature remains within the accurate range of 50°C ±3°C
Humidifying system: pulse humidification in the vacuum state ensures that the humidity in the cavity is uniform and controllable, and the humidity of the sterilizing chamber should be controlled within the range of 45-80% relative humidity
Residual gas treatment unit: filtration efficiency of filter for particle diameter ≥ 0.2mm, not less than 99.5%
Sterilization chamber leakage rate: the leakage rate was measured under the condition of no load, the temperature of sterilizing chamber was constant, the test pressure was -50 KPA, the measuring time was 1 h, and the average leakage rate was less than 0.1 KPA / min
Sealing door: hydraulic automatic opening and closing, easy operation, good sealing
Vacuum rate: under the condition of no load, the time of vacuum pumping from normal pressure to -60 KPA should be less than 30 minutes
Vacuum system: oil-free vacuum pump, simple and convenient, rapid vacuum rate, long service life
Heating system: incorporate explosion-proof electric heating device, more convenient and quicker
Additional Features
Tray rack: 304 stainless steel tray rack; trolley can be selected
Multiple protective functions: it has the function of overvoltage and overtemperature protection, which is safer and more reliable
Alarm system: high temperature alarm system, ultra-low pressure alarm system
Request a Quote
✓
Request sent
Thank you, our team will reply to you shortly.
Direct access to our team
Email American Plant & Equipment
Tell us what you want to buy, source, finance, or sell. A machinery specialist will follow up with you.
✓
Thank you. Your request is with the American Plant and Equipment team.
A machinery specialist will follow up with you.
Machinery updates
Subscribe to our email list
Tell us which industries you follow and we will send you the machines that match.
✓
You are on the list.
We will email you when machines that match your interests come in. Unsubscribe from any message.