Description Specifications Boiler feed pump: ksb chtcs-10 ht motor power (6.6kv) 2.1mw, flow 350 m3/hr, head 1584.2 mwc, 2 units Main cooling water pump: kiloskar motor abb, ht motor power (6.6kv) 1.1mw, flow 12000 m3/h, head 20 mwc, 3 units Condensate extraction pump: ksb and motor, motor abb/india, ht motor power (6.6kv) 550kw, flow 450 m3/h, head 265 mwc, 2 units Unit auxiliary transformer: voltamp 15/6.9kv, 16/20 (onan/onaf/mva), 2 units Auxiliary transformer: voltamp 2.5mva/a, 4 units; 1.25mva, 2 units; 6.6kv/429 volts Voltage: 15/400KV, 13.8/400KVCapacity: 228.9MW + 127MWBoiler: Thermax B&W PH0316 Triple Circuit HP/IP/LP FlowGas turbine generator: GE 9371FA 228.9MWGas turbine alternator: Toshiba 299KVA 50HzSteam turbine generator: Harbin Turbine 127MWSteam turbine alternator: Harbin 158.824MVA 50Hz Condition Shut down on 2017 Hour meter total 23000 hours Year of mfg is 2008 but start operation from 2012, total operation hour is 23000 hours Complex boroscope inspection made on 2021 and top condition and no further repair measures are necessary Inspection report available ttl 119 pages