Ventilators

1 Item

per page
Set Descending Direction
  1. T-6575 NON-INVASIVE VENTILATOR
    T-6575 NON-INVASIVE VENTILATOR

    NON-INVASIVE VENTILATOR
    CERTIFICATE: CE
    MEDICAL VENTILATOR
    TECHNICAL PARAMETERS OF DOUBLE LEVEL VENTILATOR
    VENTILATOR TYPE: ELECTRIC CONTROL
    SCOPE OF APPLICATION: TREATMENT AND TITRATION OF SLEEP APNEA HYPOPNEA SYNDROME, SEVERE SNORING, AND RESPIRATORY INSUFFICIENCY.
    DISPLAY INTERFACE: 3.5-INCH LED SCREEN, CHINESE OPERATING SYSTEM
    *VENTILATION MODE: CPAP, S, S/T, T
    PRESSURE RANGE:
    PRESSURE RANGE: 4-30CMH2O (±0.5CMH2O)
    PRESSURE ACCURACY: + 0.5CMH2O
    PARAMETER SETTING:
    DELAYED BOOST: 0-60MIN, SET THE DIVISION INTERVAL 5MIN
    INITIAL PRESSURE: 4CMH2O TREATMENT PRESSURE / RESPIRATORY PRESSURE SETTING
    THERAPEUTIC PRESSURE: 4-20CMH2O (IN CPAP MODE)
    TARGET TIDAL VOLUME: 150ML - 1500ML, ON/ OFF
    MAXIMUM SUCTION PRESSURE: 4-30CMH2O, (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
    MINIMUM SUCTION PRESSURE: 4-30CMH2O (NOT HIGHER THAN THE SUCTION PRESSURE), (CAN BE SET WHEN THE TARGET TIDAL VOLUME FUNCTION IS ON)
    INSPIRATORY PHASE PRESSURE: 4-30CMH2O
    EXPIRATORY PRESSURE: 4-30CMH2O
    EXPIRATORY DECOMPRESSION: PATIENT, OFF, 1-3, THREE ADJUSTABLE
    MANUAL VOLTAGE REGULATION: 0-2 GEAR, 0-2CMH2O (ONLY AVAILABLE IN CPAP MODE)
    INSPIRATORY SENSITIVITY: 1-8 STALLS
    EXPIRATORY SENSITIVITY: 1-8 STALLS
    RESPIRATORY FREQUENCY: 3-40 TIMES / MIN
    INSPIRATORY TIME: 0.3-3.0S
    BACKUP RATE: ON / OFF, DEFAULT 10
    PRESSURE RISE TIME: 1-4 STALLS
    HUMIDIFIER: 1-5 ADJUSTABLE IN 5 GEARS
    *TITRATION FUNCTION: SUPPORT MANUAL AND AUTOMATIC PRESSURE TITRATION, BUILT-IN REMOTE WIRELESS COMMUNICATION MODULE, COMPLETE THE RANDOM SWITCHING OF SINGLE AND DOUBLE LEVEL MODES IN THE TITRATION PROCESS, AND CONTROL MORE THAN 11 VENTILATOR PARAMETERS AT THE SAME TIME.
    AUXILIARY FUNCTION: AUTOMATIC AIR LEAKAGE COMPENSATION, AUTOMATIC STARTUP, AUTOMATIC SHUTDOWN, DELAYED SHUTDOWN, SCREEN BACKLIGHT ADJUSTMENT
    MONITORING PARAMETERS: PRESSURE, TIDAL VOLUME, RESPIRATORY RATE, MINUTE VENTILATION VOLUME, AIR LEAKAGE VOLUME, INSPIRATORY TIME, BLOOD OXYGEN SATURATION
    WAVY CURVE: PRESSURE TIME WAVEFORM, FLOW RATE TIME WAVEFORM
    ALARM PROMPT: PIPELINE AND MASK FALLING OFF, AIR LEAKAGE PROMPT, POWER INTERRUPTION, TREATMENT MACHINE FAILURE, HUMIDIFIER FAILURE, LOW VOLTAGE, HIGH RESPIRATORY RATE, LOW RESPIRATORY RATE, LOW MINUTE VENTILATION VOLUME, LOW BLOOD OXYGEN, REPLACEMENT OF FILTER COTTON, FULL SD CARD, RE INSERTION OF SD CARD
    *DATA MANAGEMENT:
    NETWORK DATA: BMC + RESPIRATORY HEALTH MANAGEMENT CLOUD PLATFORM
    SD CARD DATA: RESART NPAP DATA ANALYSIS SOFTWARE
    PARTS:
    SD CARD: STANDARD
    SD CARD SLOT: STANDARD
    PIPING: 9 22MM, 1.8M LONG
    FACE SHIELD: F2 NOSE MASK AS STANDARD
    NOISE: LESS THAN 30DB
    ENVIRONMENT CONDITION:
    TEMPERATURE:
    (WHEN USED) 5 -35 C
    (DURING TRANSPORTATION AND STORAGE) -20 C -55 C
    ATMOSPHERIC PRESSURE:
    (WHEN USED) 760-1060HPA
    (DURING TRANSPORTATION AND STORAGE) 760-1060HPA
    WORKING HOURS: MORE THAN 8 HOURS
    POWER SUPPLY REQUIREMENTS:
    AC VOLTAGE: 100-240V
    FREQUENCY: 50HZ/60HZ
    INPUT POWER: LESS THAN 2A
    WATERPROOF LEVEL: IP22 - DRIP PROOF EQUIPMENT
    INSTRUMENT SIZE: 290mm X 180mm X 134mm
    WEIGHT: 1.5KG (EXCLUDING HUMIDIFIER) 2.5KG (INCLUDING HUMIDIFIER)
    ITEM 001
    QUANTITY: 10 SETS-999 SETS
    ITEM 002
    QUANTITY: 1,000 SETS-9,999SETS
    ITEM 003
    QUANTITY: ≥10,000 SETS