TT-3855 CUMMINS NATURAL GAS GENERATOR SET, 1.4MW, 1400 KW, NATURAL GAS, YEAR 2017, 50Hz/60Hz

TT-3855 CUMMINS NATURAL GAS GENERATOR SET, 1.4MW, 1400 KW, NATURAL GAS, YEAR 2017, 50Hz/60Hz SERIES ENGINE MODEL C1400 N6C. USED YEAR 2017 SYSTEM INCLUDES BUILDING, COOLING SYSTEM, TRANSFORMER. TOTAL HOURS: 5400 1400 KW USED AS BACK UP GENERATOR WEIGHT: 28,300 LBS.
In stock
SKU
TT-3855
Call Image
Call: +1 (864) 574-0404

We will send this product in 2 days. Read more...

Call us now for more info about our products.

Return purchased items and get all your money back.

Buy this product and earn 10 special loyalty points!


REFERENCE NUMBER: TT-3855 CUMMINS NATURAL GAS GENERATOR SET, 1.4MW, 1400 KW, NATURAL GAS, YEAR 2017, 50Hz/60Hz SERIES ENGINE MODEL C1400 N6C. USED YEAR 2017 SYSTEM INCLUDES BUILDING, COOLING SYSTEM, TRANSFORMER. TOTAL HOURS: 5400 1400 KW USED AS BACK UP GENERATOR WEIGHT: 28,300 LBS. NATURAL GAS GENERATOR SET SERIES ENGINE 1160 KW - 1400 KW DESCRIPTION THIS CUMMINS® GAS GENERATOR SET IS A FULLY INTEGRATED POWER GENERATION SYSTEM UTILIZING STATE OF THE ART TECHNOLOGY THAT RESULTS IN OPTIMUM PERFORMANCE AND EFFICIENT USE OF FUEL FOR CONTINUOUS DUTY, CHP AND PEAKING APPLICATIONS. FEATURES CUMMINS HEAVY-DUTY ENGINE - RUGGED 4- CYCLE LEAN BURN GAS COMBUSTION ENGINE UTILIZING FULL AUTHORITY ELECTRONIC ENGINE MANAGEMENT AND MONITORING. EXHAUST EMISSIONS - LEAN BURN TECHNOLOGY PROVIDES EXHAUST EMISSIONS LEVELS AS LOW AS 350 MG/NM3 (0.7 G/HP-HR) NOX. PERMANENT MAGNET GENERATOR (PMG) - EXCITATION SYSTEM OFFERS ENHANCED MOTOR STARTING AND FAULT CLEARING SHORT CIRCUIT CAPABILITY. ALTERNATOR - SEVERAL ALTERNATOR SIZES OFFER SELECTABLE VOLTAGE AND TEMPERATURE RISE WITH LOW REACTANCE 2/3 PITCH WINDINGS; LOW WAVEFORM DISTORTION WITH NON-LINEAR LOADS, FAULT CLEARING SHORT CIRCUIT CAPABILITY, BEARING AND STATOR RTDS, ANTI-CONDENSATION HEATER, CLASS F OR H INSULATION (SEE ALTERNATOR DATASHEET FOR DETAILS). MECHANICALLY STRENGTHENED FOR USE ON UTILITY PARALLELING WITH UNRELIABLE GRID. CONTROL SYSTEM - THE POWERCOMMAND 3.3® GENERATOR SET CONTROL IS STANDARD EQUIPMENT AND PROVIDES TOTAL GENSET SYSTEM INTEGRATION INCLUDING FULL PARALLELING CAPABILITY IN GRID OR LOAD SHARE MODE, PRECISE FREQUENCY AND VOLTAGE REGULATION, ALARM AND STATUS MESSAGE DISPLAY, AMPSENTRY™ PROTECTION, OUTPUT METERING, AUTO-SHUTDOWN AT FAULT DETECTION AND A USER INTERFACE PANEL INSTALLED ONTO THE GENSET. OPTIONAL REMOTE OPERATOR PANELS ARE ALSO AVAILABLE. COOLING SYSTEM - THE GENERATOR SET IS EQUIPPED WITH THE CAPABILITY TO INTERFACE WITH A REMOTE RADIATOR OR HEAT EXCHANGER. WARRANTY AND SERVICE - BACKED BY A COMPREHENSIVE WARRANTY AND WORLDWIDE DISTRIBUTOR NETWORK THAT CAN PROVIDE ALL LEVELS OF SERVICE FROM REPLACEMENT PARTS TO PERFORMANCE GUARANTEE PROGRAMS. 50 Hz NEW MODEL: C1160 N5C OLD MODEL: GQKA KW: 1160 CONFIGURATION: 4 POLE DIRECT DRIVE 60 Hz NEW MODEL: C1400 N6C OLD MODEL: GQKA KW: 1400 CONFIGURATION: 4 POLE DIRECT DRIVE * GENSET IS CAPABLE OF OPERATING BETWEEN 0.8 LAGGING AND 1.0 POWER FACTOR. ALL FUEL CONSUMPTION AND HEAT BALANCE DATA IS AT 1.0 POWER FACTOR. GENERATOR SET SPECIFICATIONS GOVERNOR REGULATION CLASS: ISO 8528 PART 5, CLASS G1 WITH EXCEPTIONS - SEE PTS (PROTOTYPE TEST SUPPORT) DATA SHEET VOLTAGE REGULATION, NO LOAD TO FULL LOAD: ± 0.5% RANDOM VOLTAGE VARIATION: ± 0.5% FREQUENCY REGULATION: ISOCHRONOUS RANDOM FREQUENCY VARIATION: ± 0.25% RADIO FREQUENCY EMISSIONS COMPLIANCE: EN61000-6-2; EN61000-6-4; FCC PART 15 SUBPART B; ICES-002; AS/NZS 2557 SINGLE STEP LOAD PICKUP: GENERATOR SET CONFIGURATION DEPENDENT - CONSULT FACTORY FOR DETAILS ENGINE SPECIFICATIONS DESIGN: 4 CYCLE, V-BLOCK, TURBOCHARGED LOW TEMPERATURE AFTER-COOLED BORE: 159 MM (6.25 IN.) STROKE: 190 MM (7.48 IN.) DISPLACEMENT: 60.3 LITERS (3685 IN3) CYLINDER BLOCK: CAST IRON, V16 BATTERY CHARGING ALTERNATOR: NONE STARTING VOLTAGE: 24 VOLTS NEGATIVE GROUND FUEL SYSTEM: LEAN BURN IGNITION SYSTEM: INDIVIDUAL COIL ON PLUG AIR CLEANER TYPE: DRY REPLACEABLE ELEMENT LUBE OIL FILTER TYPE(S): FULL FLOW AND BYPASS FILTERS BREATHER: BREATHER FILTER ALTERNATOR SPECIFICATIONS DESIGN: BRUSHLESS, 4 POLE, REVOLVING FIELD STATOR: 2/3 PITCH ROTOR: TWO BEARING INSULATION SYSTEM: CLASS F AND H SEE ADS (ALTERNATOR DATA SHEET) FOR DETAILS STANDARD TEMPERATURE RISE: 105 °C (221 °F) CONTINUOUS @ 40 °C (104 °F) AMBIENT EXCITER TYPE: PERMANENT MAGNET GENERATOR (PMG) PHASE ROTATION: A (U), B (V), C (W) ALTERNATOR COOLING: DIRECT DRIVE CENTRIFUGAL BLOWER FAN AC WAVEFORM TOTAL HARMONIC DISTORTION (THDV): < 5% NO LOAD TO FULL LINEAR LOAD, < 3% FOR ANY SINGLE HARMONIC TELEPHONE INFLUENCE FACTOR (TIF): < 50 PER NEMA MG1-22.43 TELEPHONE HARMONIC FACTOR (THF): < 3 AVAILABLE VOLTAGES 60 Hz THREE PHASE LINE - NEUTRAL/LINE - LINE 240/416 2400/4160 254/440 7200/12470 277/480 7620/13200 347/600 7970/13800 50 Hz THREE PHASE LINE - NEUTRAL/LINE - LINE 220/380 1905/3300 230/400 3810/6600 240/415 6350/11000 254/440 NOTE: SOME VOLTAGES MAY NOT BE AVAILABLE ON ALL MODELS - CONSULT FACTORY FOR AVAILABILITY. GENERATOR SET OPTIONS AND ACCESSORIES ENGINE -NOX 350 MG/NM3 (0.9 G/HP-HR) -NOX 500 MG/NM3 (1.2 G/HP-HR) -NATURAL GAS FUEL METHANE INDEX AS LOW AS 61 FOR SOME MODELS -HIGH TEMPERATURE COOLING CIRCUIT OUTLET UP TO 95 °C (203 °F) ALTERNATOR -80 °C (176 °F) TEMPERATURE RISE -105 °C (221 °F) TEMPERATURE RISE GENERATOR SET -CE CERTIFICATION CONTROL PANEL -REMOTE OPERATOR PANEL WITH HMI320 -REMOTE OPERATOR PANEL WITH HMI420 ACCESSORIES -EXHAUST SILENCERS -GAS TRAIN -RADIATORS -BLADDER EXPANSION TANK -HEAT EXCHANGER -EXHAUST HEAT RECOVERY NOTE: SOME OPTIONS MAY NOT BE AVAILABLE ON ALL MODELS - CONSULT FACTORY FOR AVAILABILITY. POWERCOMMAND 3.3 CONTROL SYSTEM THE POWERCOMMAND CONTROL SYSTEM IS A MICROPROCESSOR BASED GENSET MONITORING, METERING AND CONTROL SYSTEM DESIGNED TO MEET THE DEMANDS OF TODAY’S ENGINE DRIVEN GENSETS. THE INTEGRATION OF ALL CONTROL FUNCTIONS INTO A SINGLE CONTROL SYSTEM PROVIDES ENHANCED RELIABILITY AND PERFORMANCE, COMPARED TO CONVENTIONAL GENSET CONTROL SYSTEMS. THESE CONTROL SYSTEMS HAVE BEEN DESIGNED AND TESTED TO MEET THE HARSH ENVIRONMENT IN WHICH GENSETS ARE TYPICALLY APPLIED. MAJOR FEATURES INCLUDE: -AMPSENTRY PROTECTION PROVIDING A FULL RANGE OF ALTERNATOR PROTECTION FUNCTIONS MATCHED TO THE ALTERNATOR PROVIDED. -EXTENDED PARALLELING (PEAK SHAVE/BASE LOAD) REGULATES THE GENSET REAL AND REACTIVE POWER OUTPUT WHILE PARALLELED TO THE UTILITY. POWER CAN BE REGULATED AT EITHER THE GENSET OR UTILITY BUS MONITORING POINT. -DIGITAL FREQUENCY SYNCHRONIZATION AND VOLTAGE MATCHING. -ISOCHRONOUS LOAD SHARE. -DROOP KW AND KVAR CONTROL. -REAL TIME CLOCK FOR FAULT AND EVENT TIME STAMPING. -REAL TIME CLOCK FOR START/STOP TO INITIATE A TEST WITH OR WITHOUT LOAD, OR A BASE LOAD OR PEAK SHAVE SESSION. -DIGITAL VOLTAGE REGULATION. THREE PHASE FULL WAVE FET TYPE REGULATOR. -GENSET/ENGINE MONITORING AND PROTECTION. -UTILITY/AC BUS METERING AND PROTECTION. -MODBUS® INTERFACE FOR INTERCONNECTING TO CUSTOMER EQUIPMENT. OPERATOR/DISPLAY PANEL -AUTO/MANUAL/RUN/STOP MODE SELECTORS. -ALPHA-NUMERIC DISPLAY WITH PUSHBUTTON ACCESS FOR VIEWING ENGINE AND ALTERNATOR DATA AND PROVIDING SETUP, CONTROLS AND ADJUSTMENT. -CIRCUIT BREAKER POSITION INDICATION AND MANUAL CONTROL. -320 X 240 PIXELS GRAPHIC LED BACKLIGHT LCD. -MULTIPLE LANGUAGE SUPPORT. ENGINE PROTECTION -ENGINE VITALS - OIL TEMPERATURE AND PRESSURE, COOLANT TEMPERATURE AND LEVELS. -DERATE. -CONFIGURABLE ALARM AND STATUS INPUTS. -EMERGENCY STOP. -LOW AND HIGH BATTERY VOLTAGE WARNING. -WEAK BATTERY WARNING. -DEAD BATTERY SHUTDOWN. -FAIL TO START (OVERCRANK) SHUTDOWN. -FAIL TO CRANK SHUTDOWN. -CRANKING LOCKOUT. ENGINE DATA -OIL TEMPERATURE AND PRESSURE. -COOLANT TEMPERATURE AND PRESSURE, HT AND LT. -INTAKE MANIFOLD PRESSURE AND TEMPERATURE. -EXHAUST TEMPERATURE AND PRESSURE. -ENGINE ELECTRONICS TEMPERATURE AND DC VOLTAGE. -GAS INLET AND DOWNSTREAM PRESSURES, MASS FLOW RATE, AND CONTROL VALVE POSITION. -SPARK ADVANCE AND KNOCK LEVEL/COUNT, PER CYLINDER. -LUBE OIL STATUS, PRIMING STATUS. -OIL AND ENGINE HEATER STATUS. -START SYSTEM STATUS. -COMPRESSOR AND COMPRESSOR BYPASS STATUS. -AUXILIARY POWER SUPPLY STATUS. AMPSENTRY ALTERNATOR PROTECTION -OVERCURRENT AND SHORT CIRCUIT SHUTDOWN. -SINGLE AND THREE PHASE FAULT CURRENT REGULATION. -OVER AND UNDER VOLTAGE SHUTDOWN. -OVER AND UNDER FREQUENCY SHUTDOWN. -OVERLOAD WARNING AND LOAD SHED ALARM OUTPUT. -REVERSE POWER AND VAR SHUTDOWN. -EXCITATION FAULT. ALTERNATOR DATA -AC VOLTAGE, LINE-TO-LINE AND LINE-TO-NEUTRAL. -THREE PHASE AC CURRENT. -FREQUENCY. -TOTAL AND INDIVIDUAL PHASE POWER FACTOR, KW AND KVA. -ALTERNATOR HEATER STATUS. -WINDING AND BEARING TEMPERATURES. OTHER DATA -GENSET HARDWARE DATA. -DATA LOGS - OPERATIONAL DATA. -FAULT HISTORY - UP TO 32 EVENTS. -START ATTEMPTS, STARTS, RUNNING HOURS, KW HOURS. -ENGINE DATA - OPERATIONAL DATA, MONITORED STATUS FUNCTIONS, AUXILIARY SYSTEM INPUTS, ETC. -SERVICE ADJUSTMENTS - OPERATIONAL, CUSTOMER CONFIGURABLE SET UP, CALIBRATION, ETC. PARALLELING DATA, FUNCTIONS AND PROTECTION -GENSET AND UTILITY/AC BUS SOURCE AC METERING. -FIRST START SENSOR™ SYSTEM. -ACTIVE DIGITAL PHASE LOCK LOOP SYNCHRONIZER. -SYNC CHECK. -ISOCHRONOUS KW AND KVAR LOAD SHARE CONTROLS. -KW IMPORT/EXPORT AND KVAR/PF CONTROL FOR EXTENDED UTILITY (MAINS) PARALLELING. -MULTIPLE GENSET LOAD DEMAND CONTROL. -POWER TRANSFER CONTROL. -BREAKER CONTROL AND STATUS MONITORING/WARNING. -INPUTS FOR REMOTE KW AND KVAR CONTROL. BASE LOAD (CONTINUOUS) DEFINITIONS APPLICABLE FOR SUPPLYING POWER CONTINUOUSLY TO A CONSTANT LOAD UP TO THE FULL OUTPUT RATING FOR UNLIMITED HOURS. NO SUSTAINED OVERLOAD CAPABILITY IS AVAILABLE FOR THIS RATING. CONSULT AUTHORIZED DISTRIBUTOR FOR RATING (EQUIVALENT TO CONTINUOUS POWER IN ACCORDANCE WITH ISO 8528, ISO 3046, AS2789, DIN 6271, AND BS 5514). THIS RATING IS NOT APPLICABLE TO ALL GENERATOR SET MODELS. GENERATOR SET DATA SHEETS 60 Hz MODEL: DATA SHEET: MN*: EMISSIONS G/HP-HR: LT (°C): HT (°C) C1400 N6C: D-3246: 75: 0.7: 50: 90 C1400 N6C: D-3247: 78: 1.0: 50: 90 50 Hz MODEL: DATA SHEET: MN*: EMISSIONS MG/NM3: LT (°C): HT (°C) C1160 N5C: D-3239: 69: 500: 50: 90 C1160 N5C: D-3240: 78: 500: 50: 95 C1160 N5C: D-3241: 67: 350: 40: 95 C1160 N5C: D-3242: 73: 500: 50: 95 C1160 N5C: D-3243: 61: 500: 40: 90 C1160 N5C: D-3244: 83: 500: 50: 95 C1160 N5C: D-3245: 75: 350: 50: 95 * MN = METHANE DIMENSIONS AND WEIGHTS MODEL: DIM ‘A’ MM (IN.) C1160 N5C: 5756 (226.6) C1400 N6C: 5756 (226.6) MODEL: DIM ‘B’ MM (IN.) C1160 N5C: 2130 (83.9) C1400 N6C: 2130 (83.9) MODEL: DIM ‘C’ MM (IN.) C1160 N5C: 2480 (97.6) C1400 N6C: 2480 (97.6) MODEL: WEIGHT X WET KG (LBS) C1160 N5C: 12877 (28388) C1400 N6C: 12877 (28388) *WEIGHTS REPRESENT A SET WITH STANDARD FEATURES. SEE OUTLINE DRAWINGS FOR WEIGHTS OF OTHER CONFIGURATIONS.
Write Your Own Review
You're reviewing:TT-3855 CUMMINS NATURAL GAS GENERATOR SET, 1.4MW, 1400 KW, NATURAL GAS, YEAR 2017, 50Hz/60Hz