TT-5191 CATERPILLAR 3616 MARINE GENSET, 4600KW, 10 HOURS, YEAR 2010, 60Hz, DIESEL OIL
TT-5191 CATERPILLAR 3616 MARINE GENSET, 4600KW, 10 HOURS, YEAR 2010, 60Hz, DIESEL OIL
CATERPILLAR 3616
YEAR: 2010
HOURS: 10
POWER: 4600KW
VOLT: 11200V
FREQUENCY: 60Hz
FUEL: DIESEL OIL
MARINE GENSET
WITH RADIATOR
WITH SPECIFCATION BOOK/MANUAL BOOK
DELIVERY TIME: TWO WEEKS
QUANTITY: 8
In stock
SKU
TT-5191
REFERENCE NUMBER: TT-5191
CATERPILLAR 3616 MARINE GENSET, 4600KW, 10 HOURS, YEAR 2010, 60Hz, DIESEL OIL
CATERPILLAR 3616
YEAR: 2010
HOURS: 10
POWER: 4600KW
VOLT: 11200V
FREQUENCY: 60Hz
FUEL: DIESEL OIL
MARINE GENSET
WITH RADIATOR
WITH SPECIFCATION BOOK/MANUAL BOOK
DELIVERY TIME: TWO WEEKS
1.0 TECHNICAL DATA
1.1 DIESEL ENGINE
MODEL CATERPILLAR 3616
TYPE V-16, 4 CYCLE
ASPIRATION TURBOCHARGER, AFTERCOOLED
RATED POWER MAX 4600 BKW
RATED SPEED 900 RPM
EMISSION IMO COMPLIANCE
OVERLOAD 110% FOR 1 HR 5060 BKW
RATING AND EMISSION BASED ON FOLLOWING AMBIENT CONDITION
AIR INLET OF THE TURBOCHARGER 45 °C
BAROMETRIC PRESSURE 100 KPA
RELATIVE HUMIDITY 60 %
SEA WATER TEMPERATURE 32 °C
BSFC (W/ PUMP +5 %/-0%) @100% LOAD 195.5 G/KW-HR
TBO APPROX. 40,000 HOURS
BORE / STROKE 280 / 300mm
DISPLACEMENT 296 L
COMPRESSION RATIO 13:1
FIRING PRESSURE, MAX. 17300 KPA
BMEP@ 100% LOAD 2283 KPA
MEAN PISTON SPEED 9.0 M/S
ENGINE DRY WEIGHT (APPROX) 28,500 KG
1.2 ALTERNATOR
TYPE SYNCHRONOUS BRUSHLESS REVOLVING FIELD W/ A DIRECT CONNECTED ROTATING
BRUSHLESS EXCITER
CODE KATO 8P12-4700
POWER RATING 5500KVA, 4400EKW, 0.8PH+110% OVERLOAD FOR 1 HR
DUTY CONTINUOUS
RATED SPEED 900RPM, 8 POLES
ELECTRICAL RATING 11.2KV, 60Hz, 3PH
CONNECTION 6 WIRE, WYE
TEMPERATURE RISE 90°C/50°C AMB.
INSULATION CLASS F
ENCLOSURE IP44
COOLING TOTALLY ENCLOSED WATER TO AIR
BEARING DESIGN TWO SLEEVE W/EXT. LUBE
NET WEIGHT (APPROX.) 25,946KG
1.3 AIR INLET SYSTEM
FLOW OF AIR AT 100% LOAD 501.6 M3/MIN
AIR TEMP. @ AIR CLEANER, MAX. 45 °C
AIR TEMP, AFTER AFTER-COOLER, ALARM 60 °C
INTAKE MANIFOLD PRESS, AT 100% LOAD 277 KPA
AIR INLET RESTRICTION, NEW/MAX. 1.25/3.8 KPA
AC PRESS, DIFF AT 100%LOAD, CLEAN STATE 3.4 KPA
1.4 HT COOLING WATER SYSTEM - JW
PUMP CAPACITY @ 900 RPM 2630 LPM
PUMP RISE @ 900 RPM 240 KPA
PUMP INLET PRESSURE, MIN. 30 KPA
INLET TEMPERATURE, NOM. 90 °C
INLET TEMPERATURE, MAX. 95 °C
INLET TEMPERATURE, MIN. 83 °C
OUTLET TEMPERATURE, ALARM 100 °C
OUTLET TEMPERATURE, STOP 104 °C
1.5 LT COOLING WATER SYSTEM - AC/OC
AC/OC WATER FLOW RATE REQUIRED 1560 LPM
INLET TEMPERATURE, NOM. 32 °C
INLET TEMPERATURE, MAX. 38 °C
1.6 EXHAUST GAS SYSTEM
GAS FLOW AT 100% LOAD 1045 M3/MIN
STACK TEMP, AT 100% LOAD 356 °C
STACK TEMP, ALARM AT 100% LOAD 550 °C
TEMP, TO TURBO AT 100% LOAD 523 °C
TEMP, TO TURBO ALARM AT 100% LOAD 650 °C
BACK PRESSURE, MAX 2.54 KPA
1.7 FUEL OIL SYSTEM
FLOW RATE, SUPPLY @ 900RPM 72.0 LPM
FLOW RATE, RETURN @ 900RPM 52 LPM
PUMP SUCTION RESTRICTION, MAX. -20 KPA
MANIFOLD PRESSURE AT 100% LOAD 430-676 KPA
RETURN LINE BACK PRESSURE, MAX. 350 KPA
BSFC (W/ PUMP +5 %/-0%) @100% LOAD 195.5 G/KW-HR
FUEL OIL RECOMMENDATION
IS08217 DMA, DMB, DMX (20 CST MAX, 1.4 CST MIN. @ 38 °C)
* FUEL CONSUMPTION ARE BASED ON 35API, 16°C FUEL HAVING A LOWER HEATING VALUE OF 42,780 KJ/KG USED AT 29°C WITH DENSITY OF 838.9 G/L
1.8 LUBRICATING OIL SYSTEM
LUBE OIL FLOW 1117 LPM
MANIFOLD PRESSURE, NOM. 380 KPA
MANIFOLD PRESS, ALARM (650-900RPM) 320 KPA
MANIFOLD PRESSURE, ALARM (0-655RPM) 120 KPA
MANIFOLD PRESS, STOP (650-900RPM) 260 KPA
MANIFOLD PRESSURE, STOP (0-655RPM) 105 KPA
MANIFOLD TEMPERATURE, ALARM 92 °C
MANIFOLD TEMPERATURE, STOP 98 °C
MANIFOLD TEMPERATURE, NOM. 85 °C
PRELUBE PUMP CAP. CONTINUOUS 23 LPM
PRELUBE PUMP CAP. INTERMITTENT 76 LPM
LUBE OIL FILTER DIFF. PRESS, MAX. 104 KPA
BSOC AT 100% LOAD 0.7 G/ KW-HR
LUBE OIL VISCOSITY GRADE: SAE40 OR SAE15W40
LUBE OIL API CLASSIFICATION: CF
CATERPILLAR LUBE OIL NAME: DEO (API CG-4)
1.9 STARTING AIR SYSTEM
AIR PRESSURE, NOMINAL 1225 KPA
AIR PRESSURE, MIN. 620 KPA
AIR PRESSURE, MAX. 1575 KPA
LOW AIR PRESSURE, ALARM 850 KPA
2.0 SCOPE OF SUPPLY
2.1 GENERAL
THE SCOPE OF SUPPLY LISTED BELOW ARE BASED ON SINGLE ENGINE UNLESS OTHERWISE
SPECIFIED
ENGINE ROTATION VIEWED FR. REAR OF FLYWHEEL CCW
ENGINE SERVICE SIDE VIEWED FR. REAR OF FLYWHEEL RIGHT HAND
POWER SUPPLY ON BOARD 480V/60Hz/3PH
230V/1PH
24V DC
2.2 AIR INTAKE SYSTEM
FRONT MOUNTED TURBOCHARGER, BASIC 297, ENGINE OIL LUBRICATED
AFTERCOOLER, FRESH WATER, CORROSION RESISTANT COATED (AIR SIDE)
AIR INLET ADAPTER (90 DEG.), MOUNTED TO TURBOCHARGER INLET
AIR CLEANER, VERTICAL, STANDARD DUTY, NORMAL VOLUME
AIR VERTICAL SUPPORT BRACKET
AIR INLET SHUTOFF
2.3 CONTROL SYSTEM
WOODWARD 2301D ELECTRONIC GOVERNOR WITH LOAD SHARING INTERFACE, HYDRAULIC
ACTUATOR, 24VDC POWER, LOOSE SUPPLIED
LOAD SHARING CONTROL IS NOT OUR SCOPE OF SUPPLY
2.4 COOLING WATER SYSTEM
SEPARATE COOLING CIRCUIT SUITABLE FOR SEA WATER 32°C MAX
PLATE TYPE HEAT EXCHANGER FOR JW CIRCUIT, TITANIUM 0.4 MM, ACCESSORY MODULE
MOUNTED, BASED ON 32°C SW AND SIZED TO SUPPLY JW
PLATE TYPE HEAT EXCHANGER FOR AC/OC/FUEL/ALTERNATOR COOLER, TITANIUM 0.4 MM,
ACCESSORY MODULE MOUNTED, BASED ON 32°C SW AND SIZE TO SUPPLY THESE
COMPONENTS WITH 38°C FRESHWATER
PLATE-TYPE OIL COOLER, STAINLESS STEEL
PLATE-TYPE FUEL COOLER, STAINLESS STEEL
JACKET WATER PUMP, GEAR DRIVEN
AC/OC PUMP,GEAR DRIVEN
BOOST PUMP, GEAR DRIVEN, NOT SELF-PRIMING
EXPANSION TANK, ACCESSORY MODULE MOUNTED
JW THERMOSTAT, 90°C
AC/OC THERMOSTAT, 32°C
HEAT RECOVERY CONNECTION, INCLUDING THERMOSTAT, LOOSE SUPPLIED
JW/LO HEATER, 480V /3PH/60Hz, BASE MOUNTED
COOLING CONNECTIONS WILL INCLUDE A SINGLE SEAWATER INLET AND A SINGLE SEAWATER
OUTLET
ANSI CONNECTION INCL. A SINGLE SEA WATER INLET AND A SINGLE SEAWATER OUTLET
FLEXIBLE CONNECTION
SEA WATER PUMP NOT INCLUDED
2.5 EXHAUST SYSTEM
DRY GAS TIGHT EXHAUST MANIFOLDS WITH SOFT SHIELDS
EXHAUST ADAPTERS, RECTANGULAR TO ROUND, VERTICAL ORIENTATION, LOOSE SUPPLIED
EXHAUST EXPANDER, 14”-18”, LOOSE SUPPLIED
EXHAUST FLEXIBLE FITTING, 18”, LOOSE SUPPLIED
EXHAUST WELD FLANGE, 18”, LOOSE SUPPLIED
EXHAUST SILENCER NOT INCLUDED
2.6 FUEL OIL SYSTEM
FUEL UNIT INJECTORS AT EACH CYLINDER
FUEL TRANSFER PUMP, GEAR DRIVEN
MANUAL FUEL PRIMING PUMP
DUPLEX FUEL FILTER, ENGINE MOUNTED
DUPLEX FUEL STRAINER, SHIPPED LOOSE, CUSTOMER REMOTE MOUNTED
FLEXIBLE CONN, AT LEAST 500MM LONG HOSE, INCL. FUEL PUMP INLET AND RETURN OIL OUT
LET, LOOSE SUPPLIED, WITH TYPE APPROVED OR CERTIFICATED BY CLASS
2.7 ALTERNATOR & ACCESSORIES
ALTERNATOR & ACCESSORIES
- BASLER DECS 200 DIGITAL VOLTAGE REGULATOR (SUPPLIED LOOSE). 0.25% REGULATION,
FIELD OVER VOLT & OVER CURRENT, EXC. DIODE MONITOR, UNDER/OVEROLT, LOSS OF
SENSING, UNDER/OVER-EXC. LIMITER, AUTO TRACKING & SWITCHING TO MANUAL
CONTROL, VAR/PF CONTROL, WITH REACTIVE LOAD SHARING INTERFACE
- REACTIVE LOAD SHARING CONTROL IN NOT OUR SCOPE OF SUPPLY
- PMG (300% SC 10 SEC) FOR REGULATOR POWER
- KATO SHALL SUPPLY & MOUNT COUPLING HUB SUITABLE FOR CATERPILLAR 3600 SERIES ENGINE
- PRIMARY BEARING LUBE OIL PUMP FOR BOTH EXC. AND DRIVE END SLEEVE BEARINGS.
OIL. OIL COOLER, PRE-LUBE PUMP, AND ALL PIPING BY OTHERS
- SLEEVE BEARING OIL LINE CONNECTION FITTINGS FOR EXTERNAL LUBRICATION (PER BEARING). 60 DEG C MAXIMUM OIL TO BE SUPPLIED BY CUSTOMER
- DRIVE END SLEEVE BEARING -NON-INSULATED - SELF LUBRICATING
- EXCITER END SLEEVE BEARING - INSULATED - SELF LUBRICATING
- STAND-OFF TERMINAL CONNECTORS, MOUNTED IN OUTLET BOX.
- (6) KATO SUPPLIED CT'S FOR DIFFERENTIAL PROTECTION. THREE MOUNTED IN OUTLET BOX,
THREE FURNISHED LOOSE FOR CUSTOMER MOUNTING.
- OVERSIZED OUTLET BOX
- DOUBLE TUBE COPPER-NICKEL AIR TO WATER HEAT EXCHANGER W/WATER LEAK DETECTOR.
EXTERNAL MAXIMUM 38°C WATER IS REQUIRED AND TO BE SUPPLIED BY OTHERS.
- SPECIAL FRAME FOR WATER COOLED TOTALLY ENCLOSED ALTERNATORS.
- SIX -100 OHM RTD'S EMBEDDED IN STATOR WINDINGS FOR TEMPERATURE MONITORING, 2 PER PHASE.
- TWO -100 OHM RTD'S INSTALLED IN BEARING HOUSING FOR TEMPERATURE MONITORING
(1 PER BRG)
- THERMOSTAT FOR COMMERCIAL SPACE HEATERS
- COMMERCIAL SPACE HEATER, SINGLE PHASE 250V OR LESS.
- ABS TEST & CERTIFICATION. INCLUDES AIR-GAP, OVER-SPEED TEST, OVERLOAD TEST,
AND STEADY STATE SHORT CIRCUIT TEST. HEAT TEST ON FIRST UNIT MAY BE REQUIRED.
- HEAT TEST PER IEEE 115 FOR FIRST UNIT ONLY.
- WITNESS OF TESTS BY CUSTOMER OR CUSTOMERS AGENT PER DAY FOR ONE UNIT ONLY.
- CALCULATED X"D =0.137 SATURATED PER REQUEST
- IP 55 TERMINAL BOX LOCATED LHSFEE WITH BOTTOM CABLE ENTRY
- 2/3'S STATOR WNDING PITCH
- INRUSH CURRENT REDUCTION MODULE FOR AVR, MOUNTED IN SWITCHBOARD, SHIPPED LOOSE
SPARES
- SPARE RECTIFIER/SUPPRESSORS (2), ONE (1) SET PER SHIPSET
- SPARE BEARING LINERS, ONE (1) SET PER SHIPSET
2.8 LUBE OIL SYSTEM - GENERATOR
PRIMARY MECHANICAL LUBE OIL PUMP, GENERATOR DRIVEN
LUBE OIL MODULE:
- PRE-LUBE/STANDBY ELECTRICAL LUBE OIL PUMP, 480 V, 3 PH, 60 Hz
- LUBE OIL TANK
- HEAT EXCHANGER, 38C FRESH WATER
- LUBE OIL FILTER
- LUBE FLOW DIVIDER
- MODULE INCL. WIRING OF THE UNIT, MOTOR STARTER, 24VDC CONTROLS, NEMA 4
ENCLOSURE, MOUNTING BRACKET FOR MOUNTING THE UNIT TO THE BASE, LINES GROUP FOR
CONNECTING TO THE GENERATOR BEARINGS
- REDUNDANT AIR PRE-LUBE PUMP FOR BLACK START
2.9 LUBE OIL SYSTEM - ENGINE
BREATHER, CRANKCASE TOP-MOUNTED
CUSTOM DRY SUMP BASE ASSEMBLY WITH AN INTEGRAL SUMP IN THE BASE ASSEMBLY FOR
15 DEG. STATIC AND 22.5 DEG DYNAMIC TILT CAPABILITY
LUBE OIL PUMP, GEAR DRIVEN
DUPLEX LUBE OIL FILTER, PAPER ELEMENT, ACCESSORY MODULE MOUNTED
CENTRIFUGAL OIL FILTERS WITH SINGLE SHUTOFF, SERVICE SIDE ENGINE MOUNTED
OIL FILTER AND DIPSTICK VALVE
OIL PRESSURE REGULATING VALVE
CRANKCASE EXPLOSION RELIEF
PRELUBE PUMP, CONTINUOUS MODE, ELECTRICAL DRIVEN, INCL. 24VDC MOTOR STARTER,
ENGINE BASE MOUNTED
BACKUP/BLACK START PRELUBE PUMP, INTERMITTENT MODE, AIR DRIVEN, BASE MOUNTED
LUBE OIL IS NOT SCOPE OF SUPPLY
2.10 MONITORING SYSTEM
2.10.1 GENSET MONITORING SYSTEM (GMS1
PROVIDING PROTECTION, MONITORING AND CONTROL, HOUSED IN A NEMA 4 (IP66)
ENCLOSURE, SENSORS ARE WIRED TO GMS
CONTROL PANEL ON ACCESSORY MODULE
10 INCH COLOR MONITOR, DISPLAYS ALL ENGINE PARAMETERS AND ALARM ANNUNCIATION
START / PRELUBE CONTROL SWITCH
FUEL CONTROL SWITCH
EMERGENCY STOP BUTTON
SPEED CONTROL SWITCH
CONTACTS ARE AVAILABLE FOR CUSTOMER USE.
- SELECTION OF LOCAL/REMOTE CONTROL OF ENGINE
- SELECTION OF IDLE/RATED CONTROL OF ENGINE
- EQUIPPED FOR REMOTE COMMUNICATION
- FOUR 4-20 MA OUTPUTS (PROGRAMMABLE)
- RELAY CONTACT SIGNALS TO THE REMOTE MONITORING SYSTEM
GAUGE
- ENGINE HOUR METER
- DIGITAL TACHOMETER
- STARTING AIR PRESSURE GAUGE
LIGHT
- PRE-LUBE STATUS LIGHT
- SUMMARY ALARM LIGHT
- SUMMARY SHUTDOWN LIGHT
- PLC FAILURE LIGHT
ENGINE SENSORS
CONTACTORS:
- LUBE OIL PRESSURE (HI/LOW SPEED)
- JACKET WATER PRESSURE
- AC/OC PRESSURE
- START AIR PRESSURE
- CRANKCASE PRESSURE
4-20 MA TRANSDUCERS:
- LUBE OIL PRESSURE (TO FILTER/TO ENGINE)
- FUEL PRESSURE (TO FILTER/TO ENGINE)
- INLET AIR MANIFOLD PRESSURE
RTD (PT100):
- LUBRICATING OIL TO ENGINE TEMPERATURE
- INLET AIR MANIFOLD TEMPERATURE
- FUEL TO ENGINE TEMPERATURE
- AC/OC INLET TEMPERATURE
- JACKET WATER OUTLET TEMPERATURE (ALARM)
- JACKET WATER OUTLET TEMPERATURE (SHUTDOWN)
- GENERATOR REAR BEARING TEMPERATURE
- GENERATOR FRONT BEARING TEMPERATURE
- GENERATOR STATOR A TEMPERATURE
- GENERATOR STATOR B TEMPERATURE
- GENERATOR STATOR C TEMPERATURE
SWITCHES:
- JACKET WATER DETECTOR
- METAL PARTICLE DETECTOR
- STARTING OIL PRESSURE OR DETECTOR
THERMOCOUPLES:
* EXHAUST THERMOCOUPLE TEMPERATURES (ONE PER CYLINDER PLUS INLET TO TURBINE AND STACK)
MODBUS COMMUNICATION
ALL MONITORED PARAMETERS AND STATUS AVAILABLE EXCEPT ENGINE START/STOP CONTROL WITCH IS CONNECTED BY HARDWIRE
ALARMS
PRESSURES:
- LOW OIL PRESSURE
- HIGH OIL FILTER DIFFERENTIAL
- LOW FUEL PRESSURE
- HIGH FUEL FILTER DIFFERENTIAL
- HIGH INLET AIR MANIFOLD PRESSURE
- LOW STARTING AIR PRESSURE
- LOW JACKET WATER PRESSURE
- LOW AC/OC WATER PRESSURE
- LOW RAW/SEA WATER PRESSURE (CUSTOMER SUPPLIED CONTACT)
TEMPERATURES:
- HIGH LUBE OIL TEMPERATURE
- HIGH INLET AIR MANIFOLD TEMPERATURE
- HIGH FUEL TEMPERATURE
- HIGH AC/OC INLET TEMPERATURE
- HIGH JACKET WATER OUTLET TEMPERATURE
- HIGH GENERATOR REAR BEARING TEMPERATURE
- HIGH GENERATOR FRONT BEARING TEMPERATURE
- HIGH GENERATOR STATOR A TEMPERATURE
- HIGH GENERATOR STATOR B TEMPERATURE
- HIGH GENERATOR STATOR C TEMPERATURE
- HIGH INDIVIDUAL EXHAUST PORT TEMPERATURE
- HIGH TURBINE INLET TEMPERATURE
- HIGH EXHAUST STACK TEMPERATURE
- HIGH EXHAUST PORT DEVIATION TEMPERATURE
OTHER:
- LOW BATTERY VOLTAGE
- LOW OIL LEVEL
- SENSOR FAILURE
- JACKET WATER DETECTION
- LOW COOLANT LEVEL (SWITCH IS SUPPLIED WITH EXPANSION TANK)
- METAL PARTICLE DETECTION
SHUTDOWNS
PRESSURE:
- LOW OIL PRESSURE
- HIGH CRANKCASE PRESSURE
- TEMPERATURE:
- HIGH JACKET WATER TEMPERATURE
- HIGH LUBE OIL TEMPERATURE
- HIGH GENERATOR BEARING TEMPERATURE
- OTHER:
- METAL PARTICLE DETECTOR
- ENGINE OVERSPEED
- CUSTOMER SHUTDOWN (NORMALLY OPEN CONTACT CUSTOMER SUPPLIED)
PROGRAMMABLE INPUTS
2 OF CUSTOMER SUPPLIED RTD'S
2 OF CUSTOMER SUPPLIED 4-20MA (0-10 VDC) SENSORS
3 OF DISCRETE ALARMS, AND 3 OF DISCRETE SHUTDOWNS
BEACON AND HORN
OIL MIST DETECTOR INCL. DRAIN GP
ENGINE MOUNTED GAUGES
FUEL PRESSURE
LUBE OIL PRESSURE
INLET AIR RESTRICTION
OTHER ENGINE PROTECTION
CYLINDER PRESSURE RELIEF VALVE
MECHANICAL CYLINDER PRESS GA VALVE
2.10.2 REMOTE MONITORING
THE ITEMS OF REMOTE MONITORING, ALARM AND PROTECTION ARE COMPLIED WITH ABS
CLASS NOTATION OF ACCU.
ALL MONITORED PARAMETERS, ALARMS, PROTECTION AND ENGINE STATUS ARE AVAILABLE ON
COMMUNICATION PORT (RS232, RS422 OR RS485 ARE AVAILABLE).
2.11 MOUNTING AND BASE
SKIDS MOUNTED, THREE POINT MOUNTING, 36” I-BEAM BASE
VIBRATION ISOLATORS, SHIPPED LOOSE
2.12 STARTING AIR SYSTEM
AIR START MOTORS, VANE TYPE, INCL. SILENCER, LUBRICATOR, AIR STRAINER, SHUTOFF VALVE AND
FLEXIBLE HOSE, MAX. AIR PRESSURE 1575 KPA
AIR PRESSURE REDUCING VALVE CONTAINING RELIEF VALVE, 3100-850 KPA, LOOSE SUPPLIED,
SHIPYARD INSTALLED
FLEXIBLE HOSES
STARTING AIR VESSEL NOT INCLUDED
2.13 GENERAL ITEMS
HIGH INERTIA FLYWHEEL
ELECTRIC BARRING DEVICE, 480V/3PH/60Hz MOTOR, EQUIPPED WITH A PENDANT
SWITCH ON A 40 FT. CORD. INCL. 50:1 MANUAL BARRING DEVICE AND A 24 VDC MOTOR
STARTER
STANDARD DAMPER GUARD
FLYWHEEL AND COUPLING GUARD
TORSIONAL COUPLING FOR TWO BEARING GENERATOR, ABS CERTIFICAFIED
ENGINE LIFTING EYES
CUSTOM ACCESSORY MODULE
PAINT, CAT YELLOW
SHRINKWRAP AND TARPAULIN PROTECTION FOR TRANSPORTATION AND STORAGE
APPROVED CUSTOM GENSET TVA, ONE PER SHIPSET
NOISE AND VIBRATION TECHNICAL DATA
TEST/COMMISSIONING PROCEDURE
FACTORY ACCEPTANCE TEST FOR ONE GEN-SET PER SHIPSET
2.14 SPARE PARTS & TOOLS
SPARE PARTS KIT
AS PER ABS RECOMMENED FOR UNRESTRICTED VOYAGE ZONE AND CAT STANDARD, ONE (1)
SET PER SHIPSET
SERVICE TOOL GROUP
3600 SPECIALIZED TOOLING, ONE (1) SET PER SHIPSET
MANUEL SERVICE PUMP, ONE (1) PER SHIPSET
PROTECTION SYSTEM CALIBRATION KIT, ONE (1) SET PER SHIPSET
OIL MIST DETECTOR TOOL KIT, ONE (1) SET PER SHIPSET
2.15 DRAWING & DOCUMENT
DRAWING & DOCUMENT FOR APPROVAL 7 PAPER+1 CD PER SHIPSET
DRAWING & DOCUMENT FOR WORKING 7 PAPER+1 CD PER SHIPSET
PARTS BOOK 7 PAPER+7CD PER SHIPSET
SERVICE MANUAL 7 PAPER PER SHIPSET
TECHNICAL. MANUAL 7 PAPER PER SHIPSET
ABS ENGINE CERTIFICATES 1 PER ENGINE
ABS GENERATOR CERTIFICATES 1 PER GENERATOR
IMO EIAPP CERTIFICATION 1 PER ENGINE
QUANTITY: 8