TT-7672 CATERPILLAR 3516E DIESEL POWERED GENERATOR SET - NEW, 24 MW, 60Hz, YEAR 2024
TT-7672 CATERPILLAR 3516E DIESEL POWERED GENERATOR SET - NEW, 24 MW, 60Hz, YEAR 2024
1. CATERPILLAR 3516 E NEW SURPLUS
2. YEAR 2024
3. 3,000KW EA 480V 60Hz
QUANTITY: 8
In stock
SKU
TT-7672
REFERENCE NUMBER: TT-7672
CATERPILLAR 3516E DIESEL POWERED GENERATOR SET - NEW, 24 MW, 60Hz, YEAR 2024
1. CATERPILLAR 3516 E NEW SURPLUS
2. YEAR 2024
3. 3,000KW EA 480V 60Hz
4. UNUSED, STILL WRAPPED UNDER SHRINK WRAP, OPEN SKID
5. READY TO MOVE WITHIN THE US
6. FULL 1 YEAR WARRANTY FROM CATERPILLAR
7. CATERPILLAR 3516E HIGH POWER DENSITY (HPD) DIESEL GENERATOR SETS
8. BORE - mm (IN): 170 (6.69)
9. STROKE - mm (IN): 215 (8.46)
10. DISPLACEMENT - L (IN3): 78.1 (4766)
11. COMPRESSION RATIO: 13.9:1
12. ASPIRATION: TA
13. FUEL SYSTEM: MEUI
14. GOVERNOR TYPE: AD EM™ A5
15. STANDBY 60 Hz EKW (KVA): 3000 (3750)
16. MISSION CRITICAL 60 Hz EKW (KVA): 3000 (3750)
17. PRIME 60 Hz EKW (KVA): 2725 (3406)
18. EMISSIONS PERFORMANCE: U.S. EPA CERTIFIED FOR EMERGENCY STATIONARY APPLICATIONS (TIER 2)
FEATURES
1. CATERPILLAR DIESEL ENGINE
2. MEETS U.S. EPA STATIONARY EMERGENCY USE ONLY (TIER 2) EMISSIONS STANDARDS
3. RELIABLE PERFORMANCE PROVEN IN THOUSANDS OF APPLICATIONS WORLDWIDE
4. CERTIFIED ALTERNATIVE FUELS INCLUDING HYDROTREATED VEGETABLE OIL (HVO), RENEWABLE DIESEL (RD) AND HYDROTREATED RENEWABLE DIESEL (HRD) WHICH MEET EN 15940 OR ASTM D975 CAN BE USED OR BLENDED WITH EN 590 DIESEL
GENERATOR SET PACKAGE
1. ACCEPTS 100% BLOCK LOAD IN ONE STEP
2. MEETS NFPA 110 LOADING REQUIREMENTS
3. CONFORMS TO ISO 8528-5 G3 LOAD ACCEPTANCE REQUIREMENTS
4. RELIABILITY VERIFIED THROUGH TORSIONAL VIBRATION, FUEL CONSUMPTION, OIL CONSUMPTION, TRANSIENT PERFORMANCE, AND ENDURANCE TESTING
ALTERNATORS
1. SUPERIOR MOTOR STARTING CAPABILITY MINIMIZES NEED FOR OVERSIZING GENERATOR
2. DESIGNED TO MATCH PERFORMANCE AND OUTPUT CHARACTERISTICS OF CATERPILLAR DIESEL ENGINES
COOLING SYSTEM
1. COOLING SYSTEMS AVAILABLE TO OPERATE IN AMBIENT TEMPERATURES UP TO 50°C (122°F)
2. TESTED TO ENSURE PROPER GENERATOR SET COOLING
CATERPILLAR ENERGY CONTROL SYSTEM (ECS)
1. USER-FRIENDLY INTERFACE AND NAVIGATION
2. SCALABLE SYSTEM TO MEET A WIDE RANGE OF INSTALLATION REQUIREMENTS
3. EXPANSION MODULES AND SITE SPECIFIC PROGRAMMING FOR SPECIFIC CUSTOMER REQUIREMENTS
4. GRAPHICAL TOUCHSCREEN DISPLAY
5. EASILY UPGRADEABLE
WARRANTY
1. 24 MONTHS/1000-HOUR WARRANTY FOR STANDBY AND MISSION CRITICAL RATINGS
2. EXTENDED SERVICE PROTECTION IS AVAILABLE TO PROVIDE EXTENDED COVERAGE OPTIONS
WORLDWIDE PRODUCT SUPPORT
1. CATERPILLAR DEALERS HAVE OVER 1,800 DEALER BRANCH STORES OPERATING IN 200 COUNTRIES
2. YOUR LOCAL CATERPILLAR DEALER PROVIDES EXTENSIVE POST-SALE SUPPORT, INCLUDING MAINTENANCE AND REPAIR AGREEMENTS
PACKAGE PERFORMANCE
1. ENGINE SPEED: 1800 RPM
2. FREQUENCY: 60 Hz
3. GEN SET POWER RATING WITH FAN: 2725 TO 3000 EKW
4. GEN SET POWER RATING WITH FAN @0.8 POWER FACTOR: 3406 TO 3750 KVA
5. EMISSIONS: TIER 2 (EPA ESE)
WEIGHTS AND DIMENSIONS
1. RATING EKW (KVA) 3000 (3750)
2. DIM “A” mm (IN) 7678 (302.3)
3. DIM “B” mm (IN) 2874 (113.2)
4. DIM “C” mm (IN) 3639 (143.3)
5. DRY WEIGHT KG (LB) 20,380 (44,930)
6. NOTE: FOR REFERENCE ONLY. DO NOT USE FOR INSTALLATION DESIGN.
RATINGS DEFINITIONS
STANDBY
1. OUTPUT AVAILABLE WITH VARYING LOAD FOR THE DURATION OF THE INTERRUPTION OF THE NORMAL SOURCE POWER. AVERAGE POWER OUTPUT IS 70% OF THE STANDBY RATED EKW. TYPICAL OPERATION IS 200 HOURS PER YEAR, WITH MAXIMUM EXPECTED USAGE OF 500 HOURS PER YEAR.
MISSION CRITICAL
1. OUTPUT AVAILABLE WITH VARYING LOAD FOR THE DURATION OF THE INTERRUPTION OF THE NORMAL SOURCE POWER. AVERAGE POWER OUTPUT IS 85% OF THE MISSION CRITICAL RATED EKW. TYPICAL PEAK DEMAND UP TO 100% OF RATED EKW FOR UP TO 5% OF THE OPERATING TIME. TYPICAL OPERATION IS 200 HOURS PER YEAR, WITH MAXIMUM EXPECTED USAGE OF 500 HOURS PER YEAR.
PRIME
1. OUTPUT AVAILABLE WITH VARYING LOAD FOR AN UNLIMITED TIME. AVERAGE POWER OUTPUT IS 70% OF THE PRIME RATED EKW. TYPICAL PEAK DEMAND IS 100% OF PRIME RATED EKW WITH 10% OVERLOAD CAPABILITY FOR EMERGENCY USE FOR A MAXIMUM OF 1 HOUR IN 12. OVERLOAD OPERATION CANNOT EXCEED 25 HOURS PER YEAR.
APPLICABLE CODES AND STANDARDS
1. AS 1359, ULC 2200 3RD EDITION, UL 489, UL 869A, IBC, I EC 60034-1, ISO 3046, ISO 8528, NEMA MG1-22, NEMA MG1-33, 2014/35/EU, 2006/42/EC, 2014/30/EU AND FACILITATES COMPLIANCE TO NFPA 37, NFPA 70, NFPA 99, NFPA 110.
2. NOTE: CODES MAY NOT BE AVAILABLE IN ALL MODEL CONFIGURATIONS. PLEASE CONSULT YOUR LOCAL CATERPILLAR DEALER FOR AVAILABILITY.
DATA CENTER APPLICATIONS
1. ALL RATINGS TIER LLL/TIER IV COMPLIANT PER UPTIME INSTITUTE REQUIREMENTS.
2. ALL RATINGS ANSI/TIA-942 COMPLIANT FOR RATED-1 THROUGH RATED-4 DATA CENTERS.
FUEL RATES
1. FUEL CONSUMPTION REPORTED IN ACCORDANCE WITH ISO 3046-1, BASED ON FUEL OIL OF 35° API [16°C (60°F)] GRAVITY HAVING AN LHV OF 42,780 KJ/KG (18,390 BTU/LB) WHEN USED AT 15°C (59°F) AND WEIGHING 850 G/LITER (7.0936 IBS/U.S. GAL.) ALL FUEL CONSUMPTION VALUES REFER TO RATED ENGINE POWER.
QUANTITY: 8