TT-7873 HURST SERIES 45 BOILER, 60W, YEAR 2016
TT-7873 HURST SERIES 45 BOILER, 60W, YEAR 2016
1. BRAND: HURST
2. MODEL: SERIES 45
3. YEAR OF MFG.: 2016
4. CONDITION: NEW, NEVER USED
QUANTITY: 1
In stock
SKU
TT-7873
REFERENCE NUMBER: TT-7873
HURST SERIES 45 BOILER, 60W, YEAR 2016
1. BRAND: HURST
2. MODEL: SERIES 45
3. YEAR OF MFG.: 2016
4. CONDITION: NEW, NEVER USED
5. ELECT. / VOLTAGE: 480 V, 60 CY, 3 PH.
6. SERIES 45:207.5 HP; 60 PSI HOT WATER; NATURAL GAS FIRED FIREBOX
7. BUILT NEW IN 2016; COMPLETE, NEVER INSTALLED & READY TO DELIVERY
8. EFFICIENT 3-PASS DESIGN NATURAL GAS FIRED FIREBOX.
9. ASME CODE CONSTRUCTED & STAMPED FOR 15 PSI STREAM; 30 - 100 PSI WATER.
10. REGISTERED WITH THE NATIONAL BOARD OF BOILER INSPECTORS.
11. EASILY MAINTAINED, DESIGNED FOR EFFICIENCY; LARGE FURNACE VOLUME FOR ULTIMATE COMBUSTION EFFICIENCY
12. UNIFIED REFRACTORY BASE FLOOR; STEEL SKIDS; LIFTING EYES.
13. LOW HEAT RELEASE; FACTORY INSULATED. - 2" MINERAL WOOL, FACTORY JACKETED & PAINTED.
14. EASY ACCESS TO FIRESIDE SURFACES; AMPLE WATERSIDE CLEAN-OUT OPENINGS
15. FULLY AUTOMATIC OPERATION; U.L. LISTED; FORCED DRAFT BURNERS.
16. WET BACK CONSTRUCTION.
17. U.L. LISTED CONTROLS & TRIM.
18. FACTORY TEST FIRED, FLAME OBSERVATION PORTS FRONT & REAR.
19. BOILER DESIGN. 3-PASS "FIREBOX" DESIGN WITH: STRESS RELIEVING "WETBACK" FIRETUBE CONSTRUCTION.
20. HOT WATER PRESSURES MODELS ARE FROM: 8.5 - 415 HP; 100 PSI MAX.; 500 - 813 HP; 60 PSI MAX. BUILT TO SECTION-IV ASME CODE.
21. HOT WATER TEMPERATURE NOT TO EXCEED 2500 DEGREES F AT OR NEAR THE OUTLET OF BOILER.
22. HOT WATER MODEL TIM. SAFETY RELIEF VALVE; OPERATING TEMPERATURE CONTROL; HIGH LIMIT TEMPERATURE CONTROL WITH MANUAL RESET; COMBINATION PRESSURE & TEMPERATURE GAUGE; LOW WATER CUTOFF CONTROL WITH MANUAL RESET.
23. HOT WATER SUPPLY. 180 DIF RETURN: 160 DIF.
24. FIRESIDE HEATING SURFACE: 830 SQ/FT. FURNACE VOLUME: 132 CU/FT.
25. HOT WATER OUTLET: 8"; HOT WATER DRAIN: 6"; DRAIN CONNECTION: 2".
26. BURNER: MATCHED UL LISTED "FORCED DRAFT" POWER BURNERS WITH FACTORY PRE-PIPED, WIRED AND TESTED FUEL CONFIGURATIONS FOR NATURAL GAS, PROPANE (LP) GAS, NO. 2 (DIESEL) OIL, OR COMBINATION OF BOTH GAS/OIL.
27. ALL UNITS ARE FACTORY PACKAGED WITH OPERATING CONTROLS, RELIEF VALVES, BURNER, AND FUEL TRAIN. INSTALLATION IS MADE SIMPLE IN THAT ONLY SERVICE CONNECTIONS ARE NEEDED TO PLACE IN OPERATION.
28. HIGH DENSITY 2" MINERAL WOOL INSULATION ASSURES LOWER RADIANT HEAT LOSS. IN ADDITION TO MEETING THE REQUIREMENTS OF U.L., BURNER SYSTEMS ARE OPTIONALLY AVAILABLE TO MEET THE REQUIREMENTS OF FM, IRI, MILITARY, AND OTHERS.
29. ACTUAL MODEL IS: HURST S45- G- 207.5- 60W