TT-8253 MWM 2032V16, 4.2 MW EACH, NATURAL GAS, YEAR 2009, 50Hz

TT-8253 MWM 2032V16, 4.2 MW EACH, NATURAL GAS, YEAR 2009, 50Hz 1. BRAND: MWM 2. MODEL: 2032V16 3. FUEL: NATURAL GAS 4. YEAR OF CONSTRUCTION: 2009 5. OPERATING HOURS: 41,600 (AVERAGE) 6. MAJOR OVERHAUL E60: 2015 (AT AVERAGE 33.600 HOURS) 7. MOTHBALLED: 2019 8. ALTERNATOR: AVK 9. FREQUENCY: 50Hz 10. VOLTAGE: 11 KV QUANTITY: 14
In stock
SKU
TT-8253
Call Image
Call: +1 (864) 574-0404

We will send this product in 2 days. Read more...

Call us now for more info about our products.

Return purchased items and get all your money back.

Buy this product and earn 10 special loyalty points!


REFERENCE NUMBER: TT-8253 MWM 2032V16, 4.2 MW EACH, NATURAL GAS, YEAR 2009, 50Hz 1. BRAND: MWM 2. MODEL: 2032V16 3. FUEL: NATURAL GAS 4. YEAR OF CONSTRUCTION: 2009 5. OPERATING HOURS: 41,600 (AVERAGE) 6. MAJOR OVERHAUL E60: 2015 (AT AVERAGE 33.600 HOURS) 7. MOTHBALLED: 2019 8. ALTERNATOR: AVK 9. FREQUENCY: 50Hz 10. VOLTAGE: 11 KV 11. RPM: 1,000 12. POWER: 5225 KVA / 4180 KW 13. THE SUB-STATION OF THE POWER PLANT CONSISTING OF 1-UNIT OF 70/80 MVA 14. (ONAN/ONAF) CAPACITY 11KV/230KV STEPUP TRANSFORMER AND ASSOCIATED OUTDOOR 15. TYPE SF6 CIRCUIT BREAKERS, CTS & PTS AND REQUIRED PROTECTION SYSTEM. 16. THE SUBSTATION IS EQUIPPED WITH AN ADEQUATE CAPACITY, FED BY PIPELINE NATURAL GAS. 17. ONGOING TECHNICAL MAINTENANCE AND SERVICE CARRIED OUT ACCORDING TO OEMS 18. RECOMMENDATIONS 19. UNIT 1 (AP # 01) MWM TCG 2032V16 20. RATED POWER: 4000 KW 21. YEAR OF MAKE: 2010 22. OPERATING HOURS: 39,998 HRS 23. AVK GENERATOR 24. 50 Hz, 11 KV 25. UNIT 2 (AP # 02) MWM TCG 2032V16 26. RATED POWER: 4000 KW 27. YEAR OF MAKE: 2010 28. OPERATING HOURS: 39,613 HRS 29. AVK GENERATOR 30. 50 Hz, 11 KV 31. UNIT 3 (AP # 03) MWM TCG 2032V16 32. RATED POWER: 4000 KW 33. YEAR OF MAKE: 2010 34. OPERATING HOURS: 41,866 HRS 35. AVK GENERATOR 36. 50 Hz, 11 KV 37. UNIT 4 (AP # 04) MWM TCG 2032V16 38. RATED POWER: 4000 KW 39. YEAR OF MAKE: 2010 40. OPERATING HOURS: 41,553 HRS 41. AVK GENERATOR 42. 50 Hz, 11 KV 43. UNIT 5 (AP # 05) MWM TCG 2032V16 44. RATED POWER: 4000 KW 45. YEAR OF MAKE: 2010 46. OPERATING HOURS: 40,808 HRS 47. AVK GENERATOR 48. 50 Hz, 11 KV 49. UNIT 6 (AP # 06) MWM TCG 2032V16 50. RATED POWER: 4000 KW 51. YEAR OF MAKE: 2010 52. OPERATING HOURS: 40,569 HRS 53. AVK GENERATOR 54. 50 Hz, 11 KV 55. UNIT 7 (AP # 07) MWM TCG 2032V16 56. RATED POWER: 4000 KW 57. YEAR OF MAKE: 2010 58. OPERATING HOURS: 43,158 HRS 59. AVK GENERATOR 60. 50 Hz, 11 KV 61. UNIT 8 (AP # 08) MWM TCG 2032V16 62. RATED POWER: 4000 KW 63. YEAR OF MAKE: 2010 64. OPERATING HOURS: 40,911 HRS 65. AVK GENERATOR 66. 50 Hz, 11 KV 67. UNIT 9 (AP # 09) MWM TCG 2032V16 68. RATED POWER: 4000 KW 69. YEAR OF MAKE: 2010 70. OPERATING HOURS: 42,420 HRS 71. AVK GENERATOR 72. 50 Hz, 11 KV 73. UNIT 10 (AP # 10) MWM TCG 2032V16 74. RATED POWER: 4000 KW 75. YEAR OF MAKE: 2010 76. OPERATING HOURS: 43,713 HRS 77. AVK GENERATOR 78. 50 Hz, 11 KV 79. UNIT 11 (AP # 11) MWM TCG 2032V16 80. RATED POWER: 4000 KW 81. YEAR OF MAKE: 2010 82. OPERATING HOURS: 42,160 HRS 83. AVK GENERATOR 84. 50 Hz, 11 KV 85. UNIT 12 (AP # 12) MWM TCG 2032V16 86. RATED POWER: 4000 KW 87. YEAR OF MAKE: 2010 88. OPERATING HOURS: 40,816 HRS 89. AVK GENERATOR 90. 50 Hz, 11 KV 91. UNIT 13 (AP # 13) MWM TCG 2032V16 92. RATED POWER: 4000 KW 93. YEAR OF MAKE: 2010 94. OPERATING HOURS: 41,291 HRS 95. AVK GENERATOR 96. 50 Hz, 11 KV 97. UNIT 14 (AP # 14) MWM TCG 2032V16 98. RATED POWER: 4000 KW 99. YEAR OF MAKE: 2010 100. OPERATING HOURS: 44,048 HRS 101. AVK GENERATOR 102. 50 Hz, 11 KV 103. INCLUDED IN THE SCOPE OF SUPPLY FOR EACH ENGINE: 104. COMPLETE ENGINE BASE FRAME (INCL. BUT NOT LIMITED TO AIR INLET BOX, GAS 105. MIXER, OIL PUMP, INTER COOLER, COUPLING) 106. EXHAUST SCAVENGING SYSTEM 107. COMPLETE EXHAUST GAS MANIFOLD WITH INSULATION (A & B BANK) 108. JACKET WATER PUMP & HEAT EXCHANGER MOUNTED ON THE BASE FRAME WITH 109. PIPEWORK 110. COMPLETE JACKET WATER PRE-HEATING SYSTEM 111. COMPLETE LUBE OIL REFILLING SYSTEM 112. LUBE OIL HEAR EXCHANGER MOUNTED TO THE BASE FRAME, WITH PIPEWORK 113. ALL ENGINE RELATED WATER, OIL AND EXHAUST PIPING ON THE 114. ENGINE BASE FRAME 115. ELECTRIC STARTER MOTORS 116. MAIN AND PRE-CHAMBER GAS TRAIN (AP # 09 & AP # 12 GAS FLOW METER XVC 117. MAINTENANCE PLATFORM 118. ALTERNATOR 119. RMS ENGINE CONTROL PANEL – TEM (CPU MISSING AT AP # 04, 05, 06, 09 120. & 12 AND AP # 10 CPU CARD XVC) 121. GCP 300A, POWER SUPPLY 400VAC, CONTROL VOLTAGE 24VDC MCC PANEL, 122. CONTROL CABLES 123. MV PANEL DETAILS 124. OUTGOING PANEL (WITHOUT BREAKER), ABB UNI GEAR (RELAY FEEDER 615 E-D 125. BUS COUPLER PANEL (WITHOUT BREAKER) ABB UNI GEAR 126. BUS PT PANEL ABB UNI GEAR 127. GENSET INCOMING MV PANEL ABB UNI GEAR (WITHOUT BREAKER) 128. GENSET INCOMING BREAKER ABB UNI GEAR (WITH BREAKER) 129. ELECTRICAL SYSTEM FOR GRID CONNECTION 130. THE SUB-STATION OF THE POWER PLANT CONSISTING OF 1-UNIT OF 70/80 MVA 131. (ONAN/ONAF) CAPACITY 11KV/230KV STEP-UP TRANSFORMER AND 132. ASSOCIATED OUTDOOR TYPE SF6 CIRCUIT BREAKERS, CTS & PTS AND REQUIRED 133. PROTECTION SYSTEM. 134. THE OUTPUT OF THE SUBSTATION IS CONNECTED TO THE 230KV SWITCHYARD. 135. NGR RATED CURRENT 850 A, POWER SUPPLY 6.6KV, 136. LV PANEL DETAILS 137. LVMVP, POWER SUPPLY VOLTAGE 400 VAC 138. LV BUS COUPLER, SUPPLY VOLTAGE 400 VAC 139. RADIATORS, PUMPS AND HEAT EXCHANGERS 140. RADIATORS, THERMOFIN X-TDH, CAPACITY 1700 KW 141. HT-PUMPS KSB 142. LT-PUMPS 143. LUBE OIL HEAT EXCHANGERS, THERMOWAVE 144. COMPRESSORS AND AIR TANKS 145. COMPRESSORS, HATLAPA, PRESSURE 30 BAR 146. AIR TANKS 147. RMS 148. FORBES MARSHALL, CAPACITY 14 MM SCFD, 149. INPUT PRESSURE: 130-145 PSIG, OUTPUT PRESSURE: 60+5 PSIG, 150. OUTPUT TEMPERATURE: 55 - 65˚ F 151. FILTRATION SYSTEM AND SILENCERS 152. PRIMARY FILTER HOUSING WITH FABRIC FILTER-16 ELEMENT 153. SILENCERS, HEIGHT 45 FEET 154. BLOWERS AND FANS 155. POWERHOUSE STEEL STRUCTURE 156. INCLUDING ROOFING, WALLS, AND THE STRUCTURE 157. TOOLS AND SPARE PARTS AS PER ATTACHED LISTS 158. SPARE PARTS (INCLUDED AS PER APPENDIX 1) 159. TOOLS (INCLUDED AS PER APPENDIX 2) 160. SET OF TECHNICAL DOCUMENTATION, INCLUDING BUT NOT LIMITED TO DRAWINGS OF 161. THE ENGINE DRAWING, P&I DIAGRAMS, WIRING DIAGRAM, SINGLE LINE DIAGRAM 162. (DELIVERY WITH FIRST SHIPMENT) QUANTITY: 14
Write Your Own Review
You're reviewing:TT-8253 MWM 2032V16, 4.2 MW EACH, NATURAL GAS, YEAR 2009, 50Hz